3 resultados para CHLORIDE CHANNELS
em Brock University, Canada
Resumo:
Rapid and large accumulation of GABA (y-aminobutyric acid) in response to a number of plant stresses has been well documented. But the role(s) of GABA in plants is not well defined. In recent years, the possibility of GABA involvement in regulating plant growth and development has been raised. In the present study, this possibility was examined. First, to rapidly and accurately determine GABA levels in plant tissues, a spectrometric method for GABA determination was developed based on a commercially available enzyme Gabase. Seventy mM LaCb almost completely removed water-soluble pigments from plant tissues which greatly interfere with the absorbance reading at 340nm. Inactivation of GAD (glutamate decarboxylase) by immediately adding methanol to a frozen plant tissue powder was suggested to prevent GABA production during extraction. The recovery of GABA with this method was approximately 100%. Second, the relationship between GABA levels and hypocotyl elongation in soybean seedlings was analyzed using different approaches to regulate in vivo GABA levels and the elongation of hypocotyls. The following major observations were made. (1) Mechanical stimulation by stroking elevated GABA levels and concurrently induced a rapid and significant reduction in hypocotyl elongation. (2) External GABA was demonstrated to penetrate into the hypocotyls using '*C-GABA. Application of external GABA elevated in vivo GABA levels, but failed to inhibit hypocotyl elongation. (3) LaCla and blue light irradiation caused an inhibition in the elongation of dark-grown hypocotyls, whereas GABA levels were not significantly affected. (4) Ca^was suggested to be involved in the signal transduction pathway leading from mechanical stimulation to GABA production, as indicated by the ability of La'* to inhibit GABA production in stimulated hypocotyls. (5) Bicuculline, saclofen and baclofen (agonists and antagonists of GABA receptors in animals) had no effect on hypocotyl elongation. It might indicate that GABA-binding components which are structurally similar to animal GABA receptors and functionally capable of regulating plant growth may not exist in plants. Therefore, the conclusion was drawn that GABA alone is not sufficient to inhibit hypocotyl elongation. Third, chloride influx in isolated Asparagus cells was enhanced by lOmM GABA during a 3 hour incubation, but the effect was not specific for GABA. Chloride efflux was not influenced by GABA. Both influx and efflux of chloride were significantly inhibited by NPPB, a chloride channel blocker. These results suggest that GABA does not influence the activity of plant chloride channels.
Resumo:
Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.
Resumo:
Please consult the paper edition of this thesis to read. It is available on the 5th Floor of the Library at Call Number: Z 9999 C54 L434 1989