4 resultados para Aluminum Chloride

em Brock University, Canada


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A number of 2-chlorobenzophenones, containing electron releasing groups (e.g. hydroxy, thiomethoxy and methoxy) in the 4' - position, were prepared by the Friess rearrangement, or the Friedel-Crafts reaction. These ketones, when treated with potassamide in liquid ammonia, underwent partial Haller-Bauer scission, unlike 2-chlorobenzophenone which is known to undergo complete scission. Under similar conditions 4-nitrobenzophenone also underwent partial scission, but the main reaction in this case was nucleophilic amination of the nitro containing ring. This amination reaction was shown not to be a useful general reaction for aromatic nitro compounds. 3-Methylxanthone was then prepared by treatment of 2- and 3- chloro-2'-hydroxy-5'-methylbenzophenone with . little, if any, attendant scission. The corresponding 2fluoro- compound also gave the xanthone, but as the 3-fluoro compound did not, it was concluded that the 2-fluoro compound reacted through a nucleophilic substitution mechanism, rather than the benzyne mechanism invoked for the chloro and bromo compounds. 3-Methylthioxanthone was synthesised by treatment of methyl 4-tolyl sulphide and 2-chlorobenzoyl chloride with aluminum chloride in carbon disu1phide, followed.by heating. This compound was also prepared by treatment of 3-chloro-2'thiomethoxy- 5'-methylbenzophenone with potassamide in liquid ammonia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Energy Dispersive X-ray Diffraction System at Brock University has been used to measure the intensities of the diffraction lines of aluminum powder sample as a function of temperature. At first, intensity measurements at high temperature were not reproducible. After some modifications have been made, we were able to measure the intensities of the diffraction lines to 815K, with good accuracy and reproducibility. Therefore the changes of the Debye-Waller factor from room temperature up to 815K for aluminum were determined with precision. Our results are in good agreement with those previously published.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Please consult the paper edition of this thesis to read. It is available on the 5th Floor of the Library at Call Number: Z 9999 C54 L434 1989