13 resultados para water drinking test
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
In this report, information is published concerning Russian water and wastewater treatment plants. The information is based on a questionnaire sent to 70 water and wastewater treatment plants in 2012-2013. The questionnaire was prepared by the International Advanced Water Technologies Centre (IAWTC) and Lahti Development Company (LADEC). The questions dealt with an assessment of the present state, the need for changes, renovation, investments, and how to improve the efficiency of the operation by training and investments. A significant need to renew the old pipelines, constructions, and processes was clearly evident. The aggregated answers can be utilized in Russia as internal benchmarking in order to arrange training and plant visits, which were requested in many of the answers. Sharing this open report with the respondents can aid networking and awareness of HELCOM requirements which relate to waste water treatment plants discharging their waste water directly or indirectly into the Baltic Sea. The aim of this report is to provide information for Finnish small and medium size companies (SMEs) as regards possible water related exportation to different parts of Russia.
Resumo:
Työn tarkoituksena oli testata jo tutkimuskeskuksella käytössä ollutta ja tutkimuskeskukselle tässä työssä kehitettyä pakkauksen vesihöyrytiiveyteen liittyvää mittausmenetelmää. Saatuja tuloksia verrattiin keskenään sekä materiaalista mitattuihin arvoihin. Elintarvikepakkauksia tutkittiin myös kosteussensoreiden, säilyvyyskokeen sekä kuljetussimuloinnin avulla. Optimoinnilla tutkittiin pakkauksen muodon vaikutusta vesihöyrytiiveyteen. Pakkauksen vesihöyrynläpäisyn mittaamiseen kehitetty menetelmä toimi hyvin ja sen toistettavuus oli hyvä. Verrattaessa sitä jo olemassa olleeseen menetelmään tulokseksi saatiin, että uusi menetelmä oli nopeampi ja vaati vähemmän työaikaa, mutta molemmat menetelmät antoivat hyviä arvoja rinnakkaisille näytteille. Kosteussensoreilla voitiin tutkia tyhjän pakkauksen sisällä olevan kosteuden muutoksia säilytyksen aikana. Säilyvyystesti tehtiin muroilla ja parhaan vesihöyrysuojan antoivat pakkaukset joissa oli alumiinilaminaatti- tai metalloitu OPP kerros. Kuljetustestauksen ensimmäisessä testissä pakkauksiin pakattiin muroja ja toisessa testissä nuudeleita. Kuljetussimuloinnilla ei ollutvaikutusta pakkausten sisäpintojen eheyteen eikä siten pakkausten vesihöyrytiiveyteen. Optimoinnilla vertailtiin eri muotoisten pakkausten tilavuus/pinta-ala suhdetta ja vesihöyrytiiveyden riippuvuutta pinta-alasta. Optimaalisimmaksi pakkaukseksi saatiin pallo, jonka pinta-ala oli pienin ja materiaalin sallima vesihöyrynläpäisy suurin ja vesihöyrybarrierin määrä pienin.
Resumo:
Uusi EPR-reaktorikonsepti on suunniteltu selviytymään tapauksista, joissa reaktorinsydän sulaa ja sula puhkaisee paineastian. Suojarakennuksen sisälle on suunniteltu alue, jolle sula passiivisesti kerätään, pidätetään ja jäähdytetään. Alueelle laaditaan valurautaelementeistä ns.sydänsieppari, joka tulvitetaan vedellä. Sydänsulan tuottama jälkilämpö siirtyyveteen, mistä se poistetaan suojarakennuksen jälkilämmönpoistojärjestelmän kautta. Suuri osa lämmöstä poistuu sydänsulasta sen yläpuolella olevaan veteen, mutta lämmönsiirron tehostamiseksi myös sydänsiepparin alapuolelle on sijoitettu vedellä täytettävät jäähdytyskanavat. Jotta sydänsiepparin toiminta voitaisiin todentaa, on Lappeenrannan Teknillisellä Yliopistolla rakennettu Volley-koelaitteisto tätä tarkoitusta varten. Koelaitteisto koostuu kahdesta täysimittaisesta valuraudasta tehdystä jäähdytyskanavasta. Sydänsulan tuottamaa jälkilämpöä simuloidaan koelaitteistossa sähkövastuksilla. Tässä työssä kuvataan simulaatioiden suorittaminen ja vertaillaan saatuja arvoja mittaustuloksiin. Työ keskittyy sydänsiepparista jäähdytyskanaviin tapahtuvan lämmönsiirron teoriaan jamekanismeihin. Työssä esitetään kolme erilaista korrelaatiota lämmönsiirtokertoimille allaskiehumisen tapauksessa. Nämä korrelaatiot soveltuvat erityisesti tapauksiin, joissa vain muutamia mittausparametreja on tiedossa. Työn toinen osa onVolley 04 -kokeiden simulointi. Ensin käytettyä simulointitapaa on kelpoistettuvertaamalla tuloksia Volley 04 ja 05 -kokeisiin, joissa koetta voitiin jatkaa tasapainotilaan ja joissa jäähdytteen käyttäytyminen jäähdytyskanavassa on tallennettu myös videokameralla. Näiden simulaatioiden tulokset ovat hyvin samanlaisiakuin mittaustulokset. Korkeammilla lämmitystehoilla kokeissa esiintyi vesi-iskuja, jotka rikkoivat videoinnin mahdollistavia ikkunoita. Tämän johdosta osassa Volley 04 -kokeita ikkunat peitettiin metallilevyillä. Joitakin kokeita jouduttiin keskeyttämään laitteiston suurten lämpöjännitysten johdosta. Tällaisten testien simulaatiot eivät ole yksinkertaisia suorittaa. Veden pinnan korkeudesta ei ole visuaalista havaintoa. Myöskään jäähdytteen tasapainotilanlämpötiloista ei ole tarkkaa tietoa, mutta joitakin oletuksia voidaan tehdä samoilla parametreilla tehtyjen Volley 05 -kokeiden perusteella. Mittaustulokset Volley 04 ja 05 -kokeista, jotka on videoitu ja voitu ajaa tasapainotilaan saakka, antoivat simulaatioiden kanssa hyvin samankaltaisia lämpötilojen arvoja. Keskeytettyjen kokeiden ekstrapolointi tasapainotilaan ei onnistunut kovin hyvin. Kokeet jouduttiin keskeyttämään niin paljon ennen termohydraulista tasapainoa, ettei tasapainotilan reunaehtoja voitu ennustaa. Videonauhoituksen puuttuessa ei veden pinnan korkeudesta saatu lisätietoa. Tuloksista voidaan lähinnä esittää arvioita siitä, mitä suuruusluokkaa mittapisteiden lämpötilat tulevat olemaan. Nämä lämpötilat ovat kuitenkin selvästi alle sydänsiepparissa käytettävän valuraudan sulamislämpötilan. Joten simulaatioiden perusteella voidaan sanoa, etteivät jäähdytyskanavien rakenteet sula, mikäli niissä on pienikin jäähdytevirtaus, eikä useampia kuin muutama vierekkäinen kanava ole täysin kuivana.
Resumo:
One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.
Resumo:
The effectiveness of water removal on press section is very important for a paper and board machine’s functioning, efficiency and economy. Today, the most effective method for wet pressing is shoe press technology. Metso has carried out a number of studies concerning anew type of water removal method for a press section, which has also been patented. These studies include rough sketches and some test runs. These issues form the basis of this thesis. The objective of this work was to gather together information for a new and enhanced waterremoval method for a press section by studying the functioning of the device andcarrying out test runs. This method is referred to here as Hydronip. The main goal was tobuild a functional test site which fulfills all the necessary requirements and has all thenecessary information gathering devices. The design process was carried out by emphasizing the safety aspects. The goal was also to gather together information about the nip structure in running conditions, the seal function, and to carry out the nip tests with paper or board wads. This thesis consists of a theory part, the design and construction of the test site, and carrying out test runs through information gathering. The theory part consists of the principals of water removal from a press section, Hydronip construction, and the requirements for the test place. The safety aspects were taken into account especially in test runs, but also in the assembly stages. The design and construction of the test site includes the selection of equipment and surroundings that are needed for managing the test runs in the best possible way at certain premises. The test site included the equipment that was already on the premises. Some equipment could be used as it was but some equipment had to be manufactured or modified from existing equipment. A functional test site with information gathering devices was accomplished as a result of thethesis. Test runs demonstrated that the Hydronip concept is, at least on a small scale,functional. Short-term tests for seal functioning showed that the seal can be lubricatedsufficiently under different kinds of nip load situations. Wad tests demonstrated that the metal belt is durable against different sizes of external particles. The seal also endured wad tests even though the pressure impacts impaired the lubrication. MTS tests showing dry content increases, combined with a rough cost calculation and the basic function of the machine in test runs, show that with some further study Hydronip could be a promising new product for water removal from a paper or board machine’s press section.
Resumo:
Environmental accountability has become a major source of competitive advantage for industrial companies, because customers consider it as relevant buying criterion. However, in order to leverage their environmental responsibility, industrial suppliers have to be able to demonstrate the environmental value of their products and services, which is also the aim of Kemira, a global water chemistry company considered in this study. The aim of this thesis is to develop a tool which Kemira can use to assess the environmental value of their solutions for the customer companies in mining industry. This study answers to questions on what kinds of methods to assess environmental impacts exist, and what kind of tool could be used to assess the environmental value of Kemira’s water treatment solutions. The environmental impacts of mining activities vary greatly between different mines. Generally the major impacts include the water related issues and wastes. Energy consumption is also a significant environmental aspect. Water related issues include water consumption and impacts in water quality. There are several methods to assess environmental impacts, for example life cycle assessment, eco-efficiency tools, footprint calculations and process simulation. In addition the corresponding financial value may be estimated utilizing monetary assessment methods. Some of the industrial companies considered in the analysis of industry best practices use environmental and sustainability assessments. Based on the theoretical research and conducted interviews, an Excel based tool utilizing reference data on previous customer cases and customer specific test results was considered to be most suitable to assess the environmental value of Kemira’s solutions. The tool can be used to demonstrate the functionality of Kemira’s solutions in customers’ processes, their impacts in other process parameters and their environmental and financial aspects. In the future, the tool may be applied to fit also Kemira’s other segments, not only mining industry.
Resumo:
Chlorophenols have been classified as possible carcinogens for humans. Chlorophenols have been used as pesticides and wood preservatives. In Finland, during 1930 – 1980s, saw mills used KY-5 wood preservative that contained 2,4,6-TCP, 2,3,4,6-TeCP and PCP. Especially in Finland chlorophenols have entered the environment by leaking from contaminated grounds of old saw mills. Although chlorophenol concentrations found in environment do not cause acute concern, long term exposure can increase the risk of cancer. SPME is relatively cheap and simple sampling method, in which the sample extraction and concentration are performed in a single step. Solvents are not required in SPME. IMS is based on the detection of sample ion drift times. Based on the drift times, reduced mobilities are calculated, which are comparable despite the measurement conditions. SPME-IMS coupling has not been used earlier in the determination of chlorophenols from water samples. The scope of this work was to study, if SPME-IMS system is suitable for detecting chloro-phenols from water samples. The aim was to determine the most optimal extraction condi-tions, which were then applied to real water samples. Following detection limits were deter-mined: 2,4,6-TCP: 0.33 mg/l; 2,3,4,6-TeCP: 0.63 mg/l and PCP: 1.63 mg/l. Detection limits were high compared to the highest possible chlorophenol concentration that is allowed in Finnish drinking water, 10 μg/l. Detected concentrations from water sample differed from verified concentrations in the case of 2,3,4,6-TeCP by 4.6 % and in the case of 2,4,6-TCP by 48.4 %. Based on the results it can be said that SPME-IMS setup is suitable for preliminary analysis of mg/l chlorophenol concentrations from water samples.
Resumo:
Ion mobility spectrometry (IMS) is a straightforward, low cost method for fast and sensitive determination of organic and inorganic analytes. Originally this portable technique was applied to the determination of gas phase compounds in security and military use. Nowadays, IMS has received increasing attention in environmental and biological analysis, and in food quality determination. This thesis consists of literature review of suitable sample preparation and introduction methods for liquid matrices applicable to IMS from its early development stages to date. Thermal desorption, solid phase microextraction (SPME) and membrane extraction were examined in experimental investigations of hazardous aquatic pollutants and potential pollutants. Also the effect of different natural waters on the extraction efficiency was studied, and the utilised IMS data processing methods are discussed. Parameters such as extraction and desorption temperatures, extraction time, SPME fibre depth, SPME fibre type and salt addition were examined for the studied sample preparation and introduction methods. The observed critical parameters were extracting material and temperature. The extraction methods showed time and cost effectiveness because sampling could be performed in single step procedures and from different natural water matrices within a few minutes. Based on these experimental and theoretical studies, the most suitable method to test in the automated monitoring system is membrane extraction. In future an IMS based early warning system for monitoring water pollutants could ensure the safe supply of drinking water. IMS can also be utilised for monitoring natural waters in cases of environmental leakage or chemical accidents. When combined with sophisticated sample introduction methods, IMS possesses the potential for both on-line and on-site identification of analytes in different water matrices.
Resumo:
Veden riittämätön puhdistus aiheuttaa riskin veden käyttäjille. Miljoonia kuolemia vuosittain aiheuttavien vesiteitse leviävien sairauksien ehkäisemiseksi vaaditaan tehokkaita juomaveden desinfiointimenetelmiä. Kuivuuden ja väestönkasvun myötä veden tarve on lisääntynyt ja vedenkulutus tulee yhä kasvamaan. Tästä syystä mahdollisuus kierrättää vettä hyödyntäen sitä esimerkiksi kasteluun on saanut yhä enemmän huomiota. Kierrätettävä vesi on kuitenkin käsiteltävä huolellisesti sen sisältämän mikrobiologisen kontaminaatioriskin vuoksi. Ultraviolettisäteily luokitellaan fysikaaliseksi desinfiointimenetelmäksi. Sen tehokkuus perustuu mikro-organismien absorboimaan UV-säteilyyn, jonka aiheuttamien DNA:ssa tai RNA:ssa tapahtuvien muutoksien seurauksena mikro-organismi inaktivoituu ja estyy lisääntymästä. UV-desinfioinnissa on tyypillisesti käytetty elohopeahöyrylamppuja. Vaihtoehtoinen UV-säteilyn lähde ovat LEDit eli valoa emittoivat diodit. Matalapaine-elohopeahöyrylamppujen emittoima säteily on aallonpituudella 254 nm ja keskipaine-elohopeahöyrylamppujen emittoima säteily on laajakaistaista säteilyä. Energiatehokkuuden lisäksi LEDien etuna on, että niillä voidaan tuottaa kapeakaista säteilyä aallonpituudella, joka parhaiten absorboituu DNA:han. Tämän diplomityön tarkoituksena oli tutkia, onko UVC-alueen aallonpituuksien yhdistelmillä synergistisiä etuja LEDien desinfiointitehokkuuteen, kun desinfioidaan virtaavaa vettä useilla säteilyannoksilla ja indikaattorimikrobina käytetään kolibakteeria. Tavoitteena oli myös tutkia tällä hetkellä saatavissa olevien LEDien desinfiointitehokkuutta energiatehokkuuden näkökulmasta. Yksittäisistä aallonpituuksista desinfiointitehokkuudeltaan parhaimmaksi osoittautui 260 nm, aallonpituuksien yhdistelmistä tehokkain oli 265 nm:n ja 260 nm:n yhdistelmä. Muilla aallonpituuksien yhdistelmillä ei saavutettu odotettua parempaa desinfiointitehokkuutta. Optiselta teholtaan parhaimmat LEDit, 265 nm, 270 nm ja 275 nm olivat kokeiden perusteella myös energiatehokkuuden kannalta tarkasteltuina parhaimmat sekä yksittäin että yhdistelminä. UVC-aallonpituuksia emittoivien LEDien optisen tehokkuuden paraneminen on edellytys LEDien hyödyntämiselle desinfioinnissa.
Resumo:
Arsenic is a toxic substance. The amount of arsenic in waste water is a raising problem because of increasing mining industry. Arsenic is connected to cancers in areas where arsenic concentration in drinking water is higher than recommendations. The main object in this master’s thesis was to research how ferrous hydroxide waste material is adsorbed arsenic from ammonia containing waste water. In this master’s thesis there is two parts: theoretical and experimental part. In theoretical part harmful effects of arsenic, theory of adsorption, isotherms modeling of adsorption and analysis methods of arsenic are described. In experimental part adsorption capacity of ferrous hydroxide waste material and adsorption time with different concentrations of arsenic were studied. Waste material was modified with two modification methods. Based on experimental results the adsorption capacity of waste material was high. The problem with waste material was that at same time with arsenic adsorption sulfur was dissolving in solution. Waste material was purified from sulfur but purification methods were not efficient enough. Purification methods require more research.
Resumo:
Water geochemistry is a very important tool for studying the water quality in a given area. Geology and climate are the major natural factors controlling the chemistry of most natural waters. Anthropogenic impacts are the secondary sources of contamination in natural waters. This study presents the first integrative approach to the geochemistry and water quality of surface waters and Lake Qarun in the Fayoum catchment, Egypt. Moreover, geochemical modeling of Lake Qarun was firstly presented. The Nile River is the main source of water to the Fayoum watershed. To investigate the quality and geochemistry of this water, water samples from irrigation canals, drains and Lake Qarun were collected during the period 2010‒2013 from the whole Fayoum drainage basin to address the major processes and factors governing the evolution of water chemistry in the investigation area. About 34 physicochemical quality parameters, including major ions, oxygen isotopes, trace elements, nutrients and microbiological parameters were investigated in the water samples. Multivariable statistical analysis was used to interpret the interrelationship between the different studied parameters. Geochemical modeling of Lake Qarun was carried out using Hardie and Eugster’s evolutionary model and a model simulated by PHREEQC software. The crystallization sequence during evaporation of Lake Qarun brine was also studied using a Jänecke phase diagram involving the system Na‒K‒Mg‒ Cl‒SO4‒H2O. The results show that the chemistry of surface water in the Fayoum catchment evolves from Ca- Mg-HCO3 at the head waters to Ca‒Mg‒Cl‒SO4 and eventually to Na‒Cl downstream and at Lake Qarun. The main processes behind the high levels of Na, SO4 and Cl in downstream waters and in Lake Qarun are dissolution of evaporites from Fayoum soils followed by evapoconcentration. This was confirmed by binary plots between the different ions, Piper plot, Gibb’s plot and δ18O results. The modeled data proved that Lake Qarun brine evolves from drainage waters via an evaporation‒crystallization process. Through the precipitation of calcite and gypsum, the solution should reach the final composition "Na–Mg–SO4–Cl". As simulated by PHREEQC, further evaporation of lake brine can drive halite to precipitate in the final stages of evaporation. Significantly, the crystallization sequence during evaporation of the lake brine at the concentration ponds of the Egyptian Salts and Minerals Company (EMISAL) reflected the findings from both Hardie and Eugster’s evolutionary model and the PHREEQC simulated model. After crystallization of halite at the EMISAL ponds, the crystallization sequence during evaporation of the residual brine (bittern) was investigated using a Jänecke phase diagram at 35 °C. This diagram was more useful than PHREEQC for predicting the evaporation path especially in the case of this highly concentrated brine (bittern). The predicted crystallization path using a Jänecke phase diagram at 35 °C showed that halite, hexahydrite, kainite and kieserite should appear during bittern evaporation. Yet the actual crystallized mineral salts were only halite and hexahydrite. The absence of kainite was due to its metastability while the absence of kieserite was due to opposed relative humidity. The presence of a specific MgSO4.nH2O phase in ancient evaporite deposits can be used as a paleoclimatic indicator. Evaluation of surface water quality for agricultural purposes shows that some irrigation waters and all drainage waters have high salinities and therefore cannot be used for irrigation. Waters from irrigation canals used as a drinking water supply show higher concentrations of Al and suffer from high levels of total coliform (TC), fecal coliform (FC) and fecal streptococcus (FS). These waters cannot be used for drinking or agricultural purposes without treatment, because of their high health risk. Therefore it is crucial that environmental protection agencies and the media increase public awareness of this issue, especially in rural areas.
Resumo:
The thesis focuses on the water chemistry of the experimental test facilities and their reference VVER reactors. The main objective of the thesis is to provide recommendations for water chemistry management for laboratory facilities (VEERA, PACTEL) simulating the VVERs and for the large future facilities of the Lappeenranta University of Technology. In the beginning, the concept of nuclear power generation and the applicability of the nuclear power usage is discussed. Next, different water chemistry and water purification systems in primary and secondary circuits currently used at the power plant have been outlined. Also the construction geometry and design of test facilities PACTEL and VEERA, as well as the operation principles of their main equipment has been described. Finally, the appropriate water chemistry and water treatment system have been proposed for the existing and future experimental facilities of LUT.
Resumo:
Solving the water crisis in the developing world is a critical issue. Four billion people in the globe, so called the Base of the Pyramid (BoP) population suffer from inadequate access to safe drinking water, while millions die daily from waterborne diseases and lack of clean water. The BoP people desperately need to obtain a satisfactory access to safe water sources. In order to address the issue, this research has been carried out. To provide holistic consideration to the matter, comprehensive exploration of various causes of the water crisis and its impacts in developing countries were discussed. Then, various viable and relevant solutions to the problem have been thoroughly scrutinized, including scientific, rational, practical and speculative approaches, examination of existing methods, technologies and products at the BoP water market. The role of clean water to the sustainable development was specifically featured. The paper also has studied social and economic factors, actors and circumstances which affect the market development of clean water technologies in the BoP. Possibilities and potentials of successful business between foreign water enterprises and BoP consumers were considered, while primary obstacles are deliberated on, with suggestion of the ways to tackle them. Technologies and products which are needed by the poor must be affordable, sustainable and of an appropriate quality. The crucial question of technology transfer was soundly discussed with pointing out main hindrances on the way of its implementation between the developed and developing world. The means to overcome these barriers were properly observed as well. To explore to some extent the possibility and feasibility of technology transfer from Finland to the BoP sector, 3 case study analyses have been implemented. Personal discussions in form of interviews were conducted at Kemira, Outotec and Fenno Water, Finnish water treatment and supply enterprises. The results of the interviews shed light on the specific practical matters, actual obstacles and potential solutions of the technology transfer from Finland to low-income countries.