The aim of the study is to developa novel robust controller based on sliding mode control technique for the hydraulic servo system with flexible load and for a flexible manipulator with the lift and jib hydraulic actuators. For the purpose of general control design, a dynamic model is derived describing the principle physical behavior for both the hydraulic servo system and the flexible hydraulic manipulator. The mechanism of hydraulic servo systems is described by basic mathematical equations of fluid powersystems and the dynamics of flexible manipulator is modeled by the assumed modemethod. The controller is constructed so as to track desired trajectories in the presence of model imprecision. Experimental and simulation results demonstratethat sliding mode control has benefits which can be used to guarantee stabilityin uncertain systems and improve the system performance and load tolerance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Control applications of switched mode power supplies have been widely investigated. The main objective ofresearch and development (R&D) in this field is always to find the most suitable control method to be implemented in various DC/DC converter topologies. Inother words, the goal is to select a control method capable of improving the efficiency of the converter, reducing the effect of disturbances (line and load variation), lessening the effect of EMI (electro magnetic interference), and beingless effected by component variation. The main objective of this research work is to study different control methods implemented in switched mode power supplies namely (PID control, hysteresis control, adaptive control, current programmed control, variable structure control (VSC), and sliding mode control (SMC). The advantages and drawbacks of each control method are given. Two control methods, the PID and the SMC are selected and their effects on DC/DC (Buck, Boost, and Buck-Boost) converters are examined. Matlab/SimulinkTM is used to implement PID control method in DC/DC Buck converter and SMC in DC/DC (Buck, and Buck Boost) converters. For the prototype, operational amplifiers (op-amps) are used to implement PID control in DC/DC Buck converter. For SMC op-amps are implemented in DC/DC Buck converter and dSPACETM is used to control the DC/DC Buck-Boost converter. The SMC can be applied to the DC/DC (Buck, Boost, and Buck-Boost) converters. A comparison of the effects of the PID control and the SMC on the DC/DC Buck converter response in steady state, under line variations, load variations, and different component variations is performed. Also the Conducted RF-Emissions between the PID and SMC DC/DC Buck Converter are compared. The thesis shows that, in comparison with the PID control, the SMC provides better steady-state response, better dynamic response, less EMI, inherent order reduction, robustness against system uncertainty disturbances, and an implicit stability proof. Giving a better steady-state and dynamic response, the SMC is implemented in a DC/DC resonant converter. The half-wave zero current switching (HWZCS) DC/DC Buck converter is selected as a converter topology. A general guideline to select the tank component values, needed for the designing of a HWZCS DC/DC Buck, is obtained. The implementation of the SMC to a HWZCS DC/DC Buck converter is analysed. The converter response is investigated in the steady-state region and in the dynamic region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of Grid connected Photovoltaic System working with DCBoost stage is investigated. The DC-Boost Converter topology is deduced from three phase half controlled bridge and controlled by Sliding Mode Control. Due to the fact that Grid connected Photovoltaic System includes Solar cells as a DC source and inverter for grid connection, those are under the scope of this research as well. The advantages of using MPPT are analyzed. The system is simulated in Matlab-Simulink™ environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Huoli ympäristön tilasta ja fossiilisten polttoaineiden hinnan nousu ovat vauhdittaneet tutkimusta uusien energialähteiden löytämiseksi. Polttokennot ovat yksi lupaavimmista tekniikoista etenkin hajautetun energiantuotannon, varavoimalaitosten sekä liikennevälineiden alueella. Polttokenno on tehonlähteenä kuitenkin hyvin epäideaalinen, ja se asettaa tehoelektroniikalle lukuisia erityisvaatimuksia. Polttokennon kytkeminen sähköverkkoon on tavallisesti toteutettu käyttämällä galvaanisesti erottavaa DC/DC hakkuria sekä vaihtosuuntaajaa sarjassa. Polttokennon kulumisen estämiseksi tehoelektroniikalta vaaditaan tarkkaa polttokennon lähtövirran hallintaa. Perinteisesti virran hallinta on toteutettu säätämällä hakkurin tulovirtaa PI (Proportional and Integral) tai PID (Proportional, Integral and Derivative) -säätimellä. Hakkurin epälineaarisuudesta johtuen tällainen ratkaisu ei välttämättä toimi kaukana linearisointipisteestä. Lisäksi perinteiset säätimet ovat herkkiä mallinnusvirheille. Tässä diplomityössä on esitetty polttokennon jännitettä nostavan hakkurin tilayhtälökeskiarvoistusmenetelmään perustuva malli, sekä malliin perustuva diskreettiaikainen integroiva liukuvan moodin säätö. Esitetty säätö on luonteeltaan epälineaarinen ja se soveltuu epälineaaristen ja heikosti tunnettujen järjestelmien säätämiseen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adaptive control systems are one of the most significant research directions of modern control theory. It is well known that every mechanical appliance’s behavior noticeably depends on environmental changes, functioning-mode parameter changes and changes in technical characteristics of internal functional devices. An adaptive controller involved in control process allows reducing an influence of such changes. In spite of this such type of control methods is applied seldom due to specifics of a controller designing. The work presented in this paper shows the design process of the adaptive controller built by Lyapunov’s function method for the Hydraulic Drive. The calculation needed and the modeling were conducting with MATLAB® software including Simulink® and Symbolic Math Toolbox™ etc. In the work there was applied the Jacobi matrix linearization of the object’s mathematical model and derivation of the suitable reference models based on Newton’s characteristic polynomial. The intelligent adaptive to nonlinearities algorithm for solving Lyapunov’s equation was developed. Developed algorithm works properly but considered plant is not met requirement of functioning with. The results showed confirmation that adaptive systems application significantly increases possibilities in use devices and might be used for correction a system’s behavior dynamics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Malaria continues to infect millions and kill hundreds of thousands of people worldwide each year, despite over a century of research and attempts to control and eliminate this infectious disease. Challenges such as the development and spread of drug resistant malaria parasites, insecticide resistance to mosquitoes, climate change, the presence of individuals with subpatent malaria infections which normally are asymptomatic and behavioral plasticity in the mosquito hinder the prospects of malaria control and elimination. In this thesis, mathematical models of malaria transmission and control that address the role of drug resistance, immunity, iron supplementation and anemia, immigration and visitation, and the presence of asymptomatic carriers in malaria transmission are developed. A within-host mathematical model of severe Plasmodium falciparum malaria is also developed. First, a deterministic mathematical model for transmission of antimalarial drug resistance parasites with superinfection is developed and analyzed. The possibility of increase in the risk of superinfection due to iron supplementation and fortification in malaria endemic areas is discussed. The model results calls upon stakeholders to weigh the pros and cons of iron supplementation to individuals living in malaria endemic regions. Second, a deterministic model of transmission of drug resistant malaria parasites, including the inflow of infective immigrants, is presented and analyzed. The optimal control theory is applied to this model to study the impact of various malaria and vector control strategies, such as screening of immigrants, treatment of drug-sensitive infections, treatment of drug-resistant infections, and the use of insecticide-treated bed nets and indoor spraying of mosquitoes. The results of the model emphasize the importance of using a combination of all four controls tools for effective malaria intervention. Next, a two-age-class mathematical model for malaria transmission with asymptomatic carriers is developed and analyzed. In development of this model, four possible control measures are analyzed: the use of long-lasting treated mosquito nets, indoor residual spraying, screening and treatment of symptomatic, and screening and treatment of asymptomatic individuals. The numerical results show that a disease-free equilibrium can be attained if all four control measures are used. A common pitfall for most epidemiological models is the absence of real data; model-based conclusions have to be drawn based on uncertain parameter values. In this thesis, an approach to study the robustness of optimal control solutions under such parameter uncertainty is presented. Numerical analysis of the optimal control problem in the presence of parameter uncertainty demonstrate the robustness of the optimal control approach that: when a comprehensive control strategy is used the main conclusions of the optimal control remain unchanged, even if inevitable variability remains in the control profiles. The results provide a promising framework for the design of cost-effective strategies for disease control with multiple interventions, even under considerable uncertainty of model parameters. Finally, a separate work modeling the within-host Plasmodium falciparum infection in humans is presented. The developed model allows re-infection of already-infected red blood cells. The model hypothesizes that in severe malaria due to parasite quest for survival and rapid multiplication, the Plasmodium falciparum can be absorbed in the already-infected red blood cells which accelerates the rupture rate and consequently cause anemia. Analysis of the model and parameter identifiability using Markov chain Monte Carlo methods is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Taajuudenmuuttajan kytkennän synnyttämä nopea jännitemuutos aiheuttaa pitkään moottorikaapeliin sähköisen värähtelyilmiön. Ilmiö on tullut erityisesti esille uusien nopeasti kytkevien puolijohdetehokytkimien ilmestyttyä markkinoille. Taajuudenmuuttajan lähtöön asennettu jännitteen nousunopeutta rajoittava suodin vähentää kaapelivärähtelyä, mutta riittävän pitkässä kaapelissa värähtely on voimakasta lähtösuotimesta huolimatta. Kaapelivärähtelyilmiön seurauksena moottorikaapelin taajuudenmuuttajan puoleiseen päähän syntyy voimakas virtavärähtely ja moottorin puoleiseen päähän voimakas jännitevärähtely. Sähkökäyttöjen vektorisäätöalgoritmit tekevät ohjauspäätöksiä moottorikaapelin taajuudenmuuttajan päästä tehtyjen virtamittausten perusteella. Säädön päätösväli on niin lyhyt, että kaapelin virtavärähtely ehtii häiritä säädön toimintaa. Tässä työssä on esitetty kaapelivärähtelyä kuvaava taajuudenmuuttajan lähtösuotimen huomioon ottava siirtofunktioperustainen matemaattinen malli. Mallin avulla kaapelivärähtelyilmiötä voi analysoida lineaarisen säätöteorian menetelmillä. Virtavärähtelyn moottorisäätöön tuomiin ongelmiin ratkaisuksi on esitetty virran mittasignaalin käsittelemistä analogisella ja digitaalisella suotimella. Simulointitulosten perusteella ratkaisua voidaan pitää toimivana. Lopuksi esitetään, kuinka avaruusvektoriteorian mukaista induktiomoottorimallia ja kaapelivärähtelymallia voidaan simuloida yhdessä.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diplomityö on tehty osana ETX-tutkimushanketta: 'Volyymiteholähteen suunnittelumetodien kehitys ja optimointi DFM-viitekehyksessä'. Työssä suunnitellaan hakkuriteholähteelle säätäjä. Tähän suunnittelun sektoriin syventyminen on teollisuudessa jäänyt monesti vähälle. Säätö on tavallisesti ajan puutteen ja apuvälineiden käytön osaamattomuuden tai puuttumisen takia suunniteltu kokeilemalla. Työssä muodostetaan jännitemuotoisesti säädetylle hakkurille piensignaalimallilla linearisoidut siirtofunktiot, joiden perusteella voidaan tarkastella hakkurin stabiilisuutta takaisinkytketyssä säätösilmukassa. Stabiiliustarkastelu tehdään taajuustasossa käyttäen Bode-kuvaajia. Näiden kuvaajien perusteella viritetään järjestelmään säätäjä. Säätäjän toimintaa aikatasossa tarkastellaan simuloimalla ja reaalisen laitteen toimimista laboratorioprototyypin avulla. Tulosten perusteella voidaan todeta, että jännitemuotoisella säädöllä flyback-hakkuri saadaan nopeaksi epäjatkuvalla käämivirralla. Mikäli halutaan hakkurin toimivan jatkuvalla käämivirralla, on syytä käyttää muita säätömenetelmiä, esimerkiksi huippuvirtasäätöä.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this doctoral thesis is to widen and develop our theoretical frameworks for discussion and analyses of feedback practices in management accounting, particularly shedding light on its formal and informal aspects. The concept of feedback in management accounting has conventionally been analyzed within cybernetic control theory, in which feedback flows as a diagnostic or comparative loop between measurable outputs and pre-set goals (see e.g. Flamholtz et al. 1985; Flamholtz 1996, 1983), i.e. as a formal feedback loop. However, the everyday feedback practices in organizations are combinations of formal and informal elements. In addition to technique-driven feedback approaches (like budgets, measurement, and reward systems) we could also categorize social feedback practices that managers see relevant and effective in the pursuit of organizational control. While cybernetics or control theories successfully capture rational and measured aspects of organizational performance and offer a broad organizational context for the analysis, many individual and informal aspects remain vague and isolated. In order to discuss and make sense of the heterogeneous field of interpretations of formal and informal feedback, both in theory and practice, dichotomous approaches seem to be insufficient. Therefore, I suggest an analytical framework of formal and informal feedback with three dimensions (3D’s): source, time, and rule. Based on an abductive analysis of the theoretical and empirical findings from an interpretive case study around a business unit called Division Steelco, the 3Dframework and formal and informal feedback practices are further elaborated vis-á-vis the four thematic layers in the organizational control model by Flamholtz et al. (1985; Flamholtz 1996, 1983): core control system, organizational structure, organizational culture, and external environment. Various personal and cultural meanings given to the formal and informal feedback practices (“feedback as something”) create multidimensional interpretative contexts. Multidimensional frameworks aim to capture and better understand both the variety of interpretations and their implications to the functionality of feedback practices, important in interpretive research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The construction of offshore structures, equipment and devices requires a high level of mechanical reliability in terms of strength, toughness and ductility. One major site for mechanical failure, the weld joint region, needs particularly careful examination, and weld joint quality has become a major focus of research in recent times. Underwater welding carried out offshore faces specific challenges affecting the mechanical reliability of constructions completed underwater. The focus of this thesis is on improvement of weld quality of underwater welding using control theory. This research work identifies ways of optimizing the welding process parameters of flux cored arc welding (FCAW) during underwater welding so as to achieve desired weld bead geometry when welding in a water environment. The weld bead geometry has no known linear relationship with the welding process parameters, which makes it difficult to determine a satisfactory weld quality. However, good weld bead geometry is achievable by controlling the welding process parameters. The doctoral dissertation comprises two sections. The first part introduces the topic of the research, discusses the mechanisms of underwater welding and examines the effect of the water environment on the weld quality of wet welding. The second part comprises four research papers examining different aspects of underwater wet welding and its control and optimization. Issues considered include the effects of welding process parameters on weld bead geometry, optimization of FCAW process parameters, and design of a control system for the purpose of achieving a desired bead geometry that can ensure a high level of mechanical reliability in welded joints of offshore structures. Artificial neural network systems and a fuzzy logic controller, which are incorporated in the control system design, and a hybrid of fuzzy and PID controllers are the major control dynamics used. This study contributes to knowledge of possible solutions for achieving similar high weld quality in underwater wet welding as found with welding in air. The study shows that carefully selected steels with very low carbon equivalent and proper control of the welding process parameters are essential in achieving good weld quality. The study provides a platform for further research in underwater welding. It promotes increased awareness of the need to improve the quality of underwater welding for offshore industries and thus minimize the risk of structural defects resulting from poor weld quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One challenge on data assimilation (DA) methods is how the error covariance for the model state is computed. Ensemble methods have been proposed for producing error covariance estimates, as error is propagated in time using the non-linear model. Variational methods, on the other hand, use the concepts of control theory, whereby the state estimate is optimized from both the background and the measurements. Numerical optimization schemes are applied which solve the problem of memory storage and huge matrix inversion needed by classical Kalman filter methods. Variational Ensemble Kalman filter (VEnKF), as a method inspired the Variational Kalman Filter (VKF), enjoys the benefits from both ensemble methods and variational methods. It avoids filter inbreeding problems which emerge when the ensemble spread underestimates the true error covariance. In VEnKF this is tackled by resampling the ensemble every time measurements are available. One advantage of VEnKF over VKF is that it needs neither tangent linear code nor adjoint code. In this thesis, VEnKF has been applied to a two-dimensional shallow water model simulating a dam-break experiment. The model is a public code with water height measurements recorded in seven stations along the 21:2 m long 1:4 m wide flume’s mid-line. Because the data were too sparse to assimilate the 30 171 model state vector, we chose to interpolate the data both in time and in space. The results of the assimilation were compared with that of a pure simulation. We have found that the results revealed by the VEnKF were more realistic, without numerical artifacts present in the pure simulation. Creating a wrapper code for a model and DA scheme might be challenging, especially when the two were designed independently or are poorly documented. In this thesis we have presented a non-intrusive approach of coupling the model and a DA scheme. An external program is used to send and receive information between the model and DA procedure using files. The advantage of this method is that the model code changes needed are minimal, only a few lines which facilitate input and output. Apart from being simple to coupling, the approach can be employed even if the two were written in different programming languages, because the communication is not through code. The non-intrusive approach is made to accommodate parallel computing by just telling the control program to wait until all the processes have ended before the DA procedure is invoked. It is worth mentioning the overhead increase caused by the approach, as at every assimilation cycle both the model and the DA procedure have to be initialized. Nonetheless, the method can be an ideal approach for a benchmark platform in testing DA methods. The non-intrusive VEnKF has been applied to a multi-purpose hydrodynamic model COHERENS to assimilate Total Suspended Matter (TSM) in lake Säkylän Pyhäjärvi. The lake has an area of 154 km2 with an average depth of 5:4 m. Turbidity and chlorophyll-a concentrations from MERIS satellite images for 7 days between May 16 and July 6 2009 were available. The effect of the organic matter has been computationally eliminated to obtain TSM data. Because of computational demands from both COHERENS and VEnKF, we have chosen to use 1 km grid resolution. The results of the VEnKF have been compared with the measurements recorded at an automatic station located at the North-Western part of the lake. However, due to TSM data sparsity in both time and space, it could not be well matched. The use of multiple automatic stations with real time data is important to elude the time sparsity problem. With DA, this will help in better understanding the environmental hazard variables for instance. We have found that using a very high ensemble size does not necessarily improve the results, because there is a limit whereby additional ensemble members add very little to the performance. Successful implementation of the non-intrusive VEnKF and the ensemble size limit for performance leads to an emerging area of Reduced Order Modeling (ROM). To save computational resources, running full-blown model in ROM is avoided. When the ROM is applied with the non-intrusive DA approach, it might result in a cheaper algorithm that will relax computation challenges existing in the field of modelling and DA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this dissertation is to increase the understanding and knowledge of field sales management control systems (i.e. sales managers monitoring, directing, evaluating and rewarding activities) and their potential consequences on salespeople. This topic is important because research conducted in the past has indicated that the choice of control system type can on the other hand have desirable consequences, such as high levels of motivation and performance, and on the other hand leadto harmful unintended consequences, such as opportunistic or unethical behaviors. Despite the fact that marketing and sales management control systems have been under rigorous research for over two decades, it still is at a very early stage of development, and several inconsistencies can be found in the research results. This dissertation argues that these inconsistencies are mainly derived from misspecification of the level of analysis in the past research. These different levels of analysis (i.e. strategic, tactical, and operational levels) involve very different decision-making situations regarding the control and motivation of sales force, which should be taken into consideration when conceptualizing the control. Moreover, the study of salesperson consequences of a field sales management control system is actually a cross-level phenomenon, which means that at least two levels of analysis are simultaneously involved. The results of this dissertation confirm the need to re-conceptualize the field sales management control system concept. It provides empirical evidence for the assertion that control should be conceptualized with more details atthe tactical/operational level of analysis than at the strategic levelof analysis. Moreover, the results show that some controls are more efficiently communicated to field salespeople than others. It is proposed that this difference is due to different purposes of control; some controls aredesigned for influencing salespersons' behavior (aim at motivating) whereas some controls are designed to aid decision-making (aim at providing information). According to the empirical results of this dissertation, the both types of controls have an impact to the sales force, but this impactis not as strong as expected. The results obtained in this dissertation shed some light to the nature of field sales management control systems, and their consequences on salespeopl

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Power electronic converter drives use, for the sake of high efficiency, pulse-width modulation that results in sequences of high-voltage high-frequency steep-edged pulses. Such a signal contains a set of high harmonics not required for control purposes. Harmonics cause reflections in the cable between the motor and the inverter leading to faster winding insulation ageing. Bearing failures and problems with electromagnetic compatibility may also result. Electrical du/dt filters provide an effective solution to problems caused by pulse-width modulation, thereby increasing the performance and service life of the electrical machines. It is shown that RLC filters effectively decrease the reflection phenomena in the cable. Improved (simple, but effective) solutions are found for both differential- and common-mode signals; these solutions use a galvanic connection between the RLC filter star point and the converter DC link. Foil chokes and film capacitors are among the most widely used components in high-power applications. In actual applications they can be placed in different parts of the cabinet. This fact complicates the arrangement of the cabinet and decreases the reliability of the system. In addition, the inductances of connection wires may prevent filtration at high frequencies. This thesis introduces a new hybrid LC filter that uses a natural capacitance between the turns of the foil choke based on integration of an auxiliary layer into it. The main idea of the hybrid LC filter results from the fact that both the foil choke and the film capacitors have the same roll structure. Moreover, the capacitance between the turns (“intra capacitance”) of the foil inductors is the reason for the deterioration of their properties at high frequencies. It is shown that the proposed filter has a natural cancellation of the intra capacitance. A hybrid LC filter may contain two or more foil layers isolated from each other and coiled on a core. The core material can be iron or even air as in the filter considered in this work. One of the foils, called the main foil, can be placed between the inverter and the motor cable. Other ones, called auxiliary foils, may be connected in star to create differential-mode noise paths, and then coupled to the DC link midpoint to guarantee a traveling path, especially for the common-mode currents. This way, there is a remarkable capacitance between the main foil and the auxiliary foil. Investigations showed that such a system can be described by a simple equivalent LC filter in a wide range of frequencies. Because of its simple hybrid construction, the proposed LC filter can be a cost-effective and competitive solution for modern power drives. In the thesis, the application field of the proposed filter is considered and determined. The basics of hybrid LC filter design are developed further. High-frequency behaviour of the proposed filter is analysed by simulations. Finally, the thesis presents experimental data proving that the hybrid LC filter can be used for du/dt of PWM pulses and reduction of common-mode currents.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A high-frequency cyclonverter acts as a direct ac-to-ac power converter circuit that does not require a diode bidge rectifier. Bridgeless topology makes it possible to remove forward voltage drop losses that are present in a diode bridge. In addition, the on-state losses can be reduced to 1.5 times the on-state resistance of switches in half-bridge operation of the cycloconverter. A high-frequency cycloconverter is reviewed and the charging effect of the dc-capacitors in ``back-to-back'' or synchronous mode operation operation is analyzed. In addition, a control method is introduced for regulating dc-voltage of the ac-side capacitors in synchronous operation mode. The controller regulates the dc-capacitors and prevents switches from reaching overvoltage level. This can be accomplished by variating phase-shift between the upper and the lower gate signals. By adding phase-shift between the gate signal pairs, the charge stored in the energy storage capacitors can be discharged through the resonant load and substantially, the output resonant current amplitude can be improved. The above goals are analyzed and illustrated with simulation. Theory is supported with practical measurements where the proposed control method is implemented in an FPGA device and tested with a high-frequency cycloconverter using super-junction power MOSFETs as switching devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Työ sisältää ohjaislaitteiston vertailun ja valinnan rinnakkaisrakenteista robottia varten sekä kunnonvalvontajärjestelmän periaatteiden laadinnan kyseistä robottia varten. Ohjauslaitteisto sisältää teollisuustietokoneen sekä kenttäväylän. Sekä tietokoneesta että väylästä on teoriaosuus ja yksityiskohtaisempi valintaosuus. Teoriaosuudessa selitetään tarkemmin laitteiden toimintaperiaatteista. Valintaosuudessa kerrotaanmiksi jokin tietty laite on valittu käytettäväksi robotin ohjauksessa. Kunnonvalvontateoria ja rinnakkaisrakenteisen robotin kunnonvalvonnan keinot ovat työn toinen osa. Teoriaosa sisältää yleisluonteisen selvityksen vikaantumisesta ja valvonnasta. Erikoisrobotin kunnonvalvonnan keinot esitetään työssä tietyssä järjestyksessä. Ensin esitetään mahdolliset vikatilanteet. Toisessa kohdassa havainnollistetaan vikojen havaitseminen.