13 resultados para bipolar

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bipolar disorder (BPD) is a severe mental disorder associated with considerable morbidity and mortality. Prenatal insults have been shown to be associated with later development of mental disorders and there is a growing interest in the potential role of prenatal and perinatal risk factors in the development of BPD. The aims of this thesis were to describe the overall study design of the Finnish Prenatal Study of Bipolar Disorders (FIPS-B) and demographic characteristics of the sample. Furthermore, it was aimed to examine the association of parental age, parental age difference, perinatal complications and maternal smoking during pregnancy with BPD. This thesis is based on FIPS-B, a nested case-control study using several nationwide registers. The cases included all people born in Finland between January 1st 1983 and December 31st 1998 and diagnosed with BPD according to the Finnish Hospital Discharge Register (FHDR) before December 31st 2008. Controls for this study were people who were without BPD, schizophrenia or diagnoses related to these disorders, identified from the Population Register Centre (PRC), and matched two-fold to the cases on sex, date of birth (+/- 30 days), and residence in Finland on the first day of diagnosis of the matched case. Conditional logistic regression models were used to examine the association between risk factors and BPD. This study included 1887 BPD cases and 3774 matched controls. The mean age at diagnosis was 19.3 years and females accounted for 68% of the cases. Mothers with the lowest educational level had the highest odds of having BPD in offspring. Being born in Eastern and Southern region of Finland increased the odds of having BPD later in life. A U-shaped distribution of odds ratio was observed between paternal age and BPD in the unadjusted analysis. Maternal age and parental age difference was not associated with BPD. Birth by planned caesarean section was associated with increased odd of BPD. Smoking during pregnancy was not associated with BPD in the adjusted analyses. Region of birth and maternal educational level were associated with BPD. Both young and old father’s age was associated with BPD. Most perinatal complications and maternal smoking during pregnancy were not associated with BPD. The findings of this thesis, considered together with previous literature, suggest that the pre- and perinatal risk factor profile varies among different psychiatric disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During mitosis, the duplicated genome must be accurately divided between two daughter cells. Polo-like kinase 1 (Plk1) and Aurora B kinase, together with its binding partners Incenp, Survivin and Borealin (chromosomal passenger complex, CPC), have key roles in coordinating mitotic events. The accuracy of cell division is safeguarded by a signaling cascade termed the mitotic spindle checkpoint (SC), which ensures that chromosomes are not physically separated before correct bipolar attachments have been formed between kinetochores and spindle microtubules (MT). An inhibitory “wait anaphase” signal, which delays chromosome separation (anaphase onset), is created at individual kinetochores and broadcasted throughout the cell in response to lack of kinetochore-microtubule (kMT) attachment or proper interkinetochore tension. It is believed that the fast turnover of SC molecules at kinetochores contributes to the cell’s ability to produce this signal and enables rapid responses to changing cellular conditions. Kinetochores that lack MT attachment and tension express a certain phosphoepitope called the 3F3/2 phosphoepitope, which has been linked to SC signaling. In the experimental part, we investigated the regulation of the 3F3/2 phosphoepitope, analyzed whether CPC molecules turn over at centromeres, and dissected the mitotic roles of the CPC using a microinjection technique that allowed precise temporal control over its function. We found that the kinetochore 3F3/2 phosphoepitope is created by Plk1, and that CPC proteins exhibit constant exchange at centromeres. Moreover, we found that CPC function is necessary in the regulation of chromatid movements and spindle morphology in anaphase. In summary, we identified new functions of key mitotic regulators Plk1 and CPC, and provided insighs into the coordination of mitotic events.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An oscillating overvoltage has become a common phenomenon at the motor terminal in inverter-fed variable-speed drives. The problem has emerged since modern insulated gate bipolar transistors have become the standard choice as the power switch component in lowvoltage frequency converter drives. Theovervoltage phenomenon is a consequence of the pulse shape of inverter output voltage and impedance mismatches between the inverter, motor cable, and motor. The overvoltages are harmful to the electric motor, and may cause, for instance, insulation failure in the motor. Several methods have been developed to mitigate the problem. However, most of them are based on filtering with lossy passive components, the drawbacks of which are typically their cost and size. In this doctoral dissertation, application of a new active du/dt filtering method based on a low-loss LC circuit and active control to eliminate the motor overvoltages is discussed. The main benefits of the method are the controllability of the output voltage du/dt within certain limits, considerably smaller inductances in the filter circuit resulting in a smaller physical component size, and excellent filtering performance when compared with typical traditional du/dt filtering solutions. Moreover, no additional components are required, since the active control of the filter circuit takes place in the process of the upper-level PWM modulation using the same power switches as the inverter output stage. Further, the active du/dt method will benefit from the development of semiconductor power switch modules, as new technologies and materials emerge, because the method requires additional switching in the output stage of the inverter and generation of narrow voltage pulses. Since additional switching is required in the output stage, additional losses are generated in the inverter as a result of the application of the method. Considerations on the application of the active du/dt filtering method in electric drives are presented together with experimental data in order to verify the potential of the method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During mitotic cell division, the genetic material packed into chromosomes is divided equally between two daughter cells. Before the separation of the two copies of a chromosome (sister chromatids), each chromosome has to be properly connected with microtubules of the mitotic spindle apparatus and aligned to the centre of the cell. The spindle assembly checkpoint (SAC) monitors connections between microtubules and chromosomes as well as tension applied across the centromere. Microtubules connect to a chromosome via kinetochores, which are proteinaceous organelles assembled onto the centromeric region of the sister chromatids. Improper kinetochore-microtubule attachments activate the SAC and block chromosome segregation until errors are corrected and all chromosomes are connected to the mitotic spindle in a bipolar manner. The purpose of this surveillance mechanism is to prevent loss or gain of chromosomes in daughter cells that according to current understanding contributes to cancer formation. Numerous proteins participate in the regulation of mitotic progression. In this thesis, the mitotic tasks of three kinetochore proteins, Shugoshin 1 (Sgo1), INCENP, and p38 MAP kinase (p38 MAPK), were investigated. Sgo1 is a protector of centromeric cohesion. It is also described in the tension-sensing mechanism of the SAC and in the regulation of kinetochore-microtubule connections. Our results revealed a central role for Sgo1 in a novel branch of kinetochore assembly. INCENP constitutes part of the chromosomal passenger complex (CPC). The other members of the core complex are the Aurora B kinase, Survivin and Borealin. CPC is an important regulatory element of cell division having several roles at various stages of mitosis. Our results indicated that INCENP and Aurora B are highly dynamic proteins at the mitotic centromeres and suggested a new role for CPC in regulation of chromosome movements and spindle structure during late mitosis. The p38 MAPK has been implicated in G1 and G2 checkpoints during the cell cycle. However, its role in mitotic progression and control of SAC signaling has been controversial. In this thesis, we discovered a novel function for p38γ MAPK in chromosome orientation and spindle structure as well as in promotion of viability of mitotic cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tehoelektroniikkalaitteiden tehon kasvun myötä niiden hyötysuhteesta on tullut yksi niiden tärkeimmistä ominaisuuksista. Suurilla tehoilla prosentuaalisesti pienetkin tehohäviöt ovat merkittäviä ja aiheuttavat laitteen käyttäjälle ylimääräisiä energiakustannuksia ja tarvetta hukkalämmön poistolle. Näistä syistä asiakkaat vaativat hyvällä hyötysuhteella toimivia laitteita, joten laitevalmistajat pyrkivät tekemään niistä sellaisia. Simulaatiomallit ovat arvokkaita työkaluja laitesuunnittelussa. Hyötysuhdeoptimoinnin kannalta tehohäviöt tulisi pystyä mallintamaan, jotta komponenttivalintojen, ohjaustapojen ja pääpiiritopologioiden vaikutusta hyötysuhteeseen voitaisiin arvioida. Tässä työssä perehdytään eristehilabipolaaritransistorista (IGBT) tehtyihin simulaatiomalleihin ja arvioidaan niiden soveltuvuutta IGBT:ssä syntyvien tehohäviöiden mallintamiseen. Lisäksi verrataan mallia mittaukseen ja pohditaan, millaiset vaatimukset simulaatiomalliin todellisuudessa kohdistuvat.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays power drives are the essential part almost of all technological processes. Improvement of efficiency and reduction of losses require development of semiconductor switches. It has a particular meaning for the constantly growing market of renewable sources, especially for wind turbines, which demand more powerful semiconductor devices for control with growth of power. Also at present semiconductor switches are the key component in energy transmission, optimization of generation and network connection. The aim of this thesis is to make a survey of contemporary semiconductor components, showing difference in structures, advantages, disadvantages and most suitable applications. There is topical information about voltage, frequency and current limits of different switches. Study tries to compare dimensions and price of different components. Main manufacturers of semiconductor components are presented with the review of devices produced by them, and a conclusion about their availability was made. IGBT is selected as a main component in this study, because nowadays it is the most attractive component for usage in power drives, especially at the low levels of medium voltage. History of development of IGBT structure, static and dynamic characteristics are considered. Thesis tells about assemblies and connection of components and problems which can appear. One of key questions about semiconductor materials and their future development was considered. For the purpose of comparison strong and weak sides of different switches, calculation of losses of IGBT and its basic competitor – IGCT is presented. This master’s thesis makes an effort to answer the question if there are at present possibilities of accurate selection of switches for electrical drives of different rates of power and looks at future possible ways of development of semiconductor market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Frequency converters are widely used in the industry to enable better controllability and efficiency of variable speed AC motor drives. Despite these advantages, certain challenges concerning the inverter and motor interfacing have been present for decades. As insulated gate bipolar transistors entered the market, the inverter output voltage transition rate significantly increased compared with their predecessors. Inverters operate based on pulse width modulation of the output voltage, and the steep voltage edge fed by the inverter produces a motor terminal overvoltage. The overvoltage causes extra stress to the motor insulation, which may lead to a prematuremotor failure. The overvoltage is not generated by the inverter alone, but also by the sum effect of the motor cable length and the impedance mismatch between the cable and the motor. Many solutions have been shown to limit the overvoltage, and the mainstream products focus on passive filters. This doctoral thesis studies an alternative methodology for motor overvoltage reduction. The focus is on minimization of the passive filter dimensions, physical and electrical, or better yet, on operation without any filter. This is achieved by additional inverter control and modulation. The studied methods are implemented on different inverter topologies, varying in nominal voltage and current.For two-level inverters, the studied method is termed active du/dt. It consists of a small output LC filter, which is controlled by an independent modulator. The overvoltage is limited by a reduced voltage transition rate. For multilevel inverters, an overvoltage mitigation method operating without a passive filter, called edge modulation, is implemented. The method uses the capability of the inverter to produce two switching operations in the same direction to cancel the oscillating voltages of opposite phases. For parallel inverters, two methods are studied. They are both intended for two-level inverters, but the first uses individual motor cables from each inverter while the other topology applies output inductors. The overvoltage is reduced by interleaving the switching operations to produce a similar oscillation accumulation as with the edge modulation. The implementation of these methods is discussed in detail, and the necessary modifications to the control system of the inverter are presented. Each method is experimentally verified by operating industrial frequency converters with the modified control. All the methods are found feasible, and they provide sufficient overvoltage protection. The limitations and challenges brought about by the methods are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this doctoral thesis, methods to estimate the expected power cycling life of power semiconductor modules based on chip temperature modeling are developed. Frequency converters operate under dynamic loads in most electric drives. The varying loads cause thermal expansion and contraction, which stresses the internal boundaries between the material layers in the power module. Eventually, the stress wears out the semiconductor modules. The wear-out cannot be detected by traditional temperature or current measurements inside the frequency converter. Therefore, it is important to develop a method to predict the end of the converter lifetime. The thesis concentrates on power-cycling-related failures of insulated gate bipolar transistors. Two types of power modules are discussed: a direct bonded copper (DBC) sandwich structure with and without a baseplate. Most common failure mechanisms are reviewed, and methods to improve the power cycling lifetime of the power modules are presented. Power cycling curves are determined for a module with a lead-free solder by accelerated power cycling tests. A lifetime model is selected and the parameters are updated based on the power cycling test results. According to the measurements, the factor of improvement in the power cycling lifetime of modern IGBT power modules is greater than 10 during the last decade. Also, it is noticed that a 10 C increase in the chip temperature cycle amplitude decreases the lifetime by 40%. A thermal model for the chip temperature estimation is developed. The model is based on power loss estimation of the chip from the output current of the frequency converter. The model is verified with a purpose-built test equipment, which allows simultaneous measurement and simulation of the chip temperature with an arbitrary load waveform. The measurement system is shown to be convenient for studying the thermal behavior of the chip. It is found that the thermal model has a 5 C accuracy in the temperature estimation. The temperature cycles that the power semiconductor chip has experienced are counted by the rainflow algorithm. The counted cycles are compared with the experimentally verified power cycling curves to estimate the life consumption based on the mission profile of the drive. The methods are validated by the lifetime estimation of a power module in a direct-driven wind turbine. The estimated lifetime of the IGBT power module in a direct-driven wind turbine is 15 000 years, if the turbine is located in south-eastern Finland.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This doctoral thesis introduces an improved control principle for active du/dt output filtering in variable-speed AC drives, together with performance comparisons with previous filtering methods. The effects of power semiconductor nonlinearities on the output filtering performance are investigated. The nonlinearities include the timing deviation and the voltage pulse waveform distortion in the variable-speed AC drive output bridge. Active du/dt output filtering (ADUDT) is a method to mitigate motor overvoltages in variable-speed AC drives with long motor cables. It is a quite recent addition to the du/dt reduction methods available. This thesis improves on the existing control method for the filter, and concentrates on the lowvoltage (below 1 kV AC) two-level voltage-source inverter implementation of the method. The ADUDT uses narrow voltage pulses having a duration in the order of a microsecond from an IGBT (insulated gate bipolar transistor) inverter to control the output voltage of a tuned LC filter circuit. The filter output voltage has thus increased slope transition times at the rising and falling edges, with an opportunity of no overshoot. The effect of the longer slope transition times is a reduction in the du/dt of the voltage fed to the motor cable. Lower du/dt values result in a reduction in the overvoltage effects on the motor terminals. Compared with traditional output filtering methods to accomplish this task, the active du/dt filtering provides lower inductance values and a smaller physical size of the filter itself. The filter circuit weight can also be reduced. However, the power semiconductor nonlinearities skew the filter control pulse pattern, resulting in control deviation. This deviation introduces unwanted overshoot and resonance in the filter. The controlmethod proposed in this thesis is able to directly compensate for the dead time-induced zero-current clamping (ZCC) effect in the pulse pattern. It gives more flexibility to the pattern structure, which could help in the timing deviation compensation design. Previous studies have shown that when a motor load current flows in the filter circuit and the inverter, the phase leg blanking times distort the voltage pulse sequence fed to the filter input. These blanking times are caused by excessively large dead time values between the IGBT control pulses. Moreover, the various switching timing distortions, present in realworld electronics when operating with a microsecond timescale, bring additional skew to the control. Left uncompensated, this results in distortion of the filter input voltage and a filter self-induced overvoltage in the form of an overshoot. This overshoot adds to the voltage appearing at the motor terminals, thus increasing the transient voltage amplitude at the motor. This doctoral thesis investigates the magnitude of such timing deviation effects. If the motor load current is left uncompensated in the control, the filter output voltage can overshoot up to double the input voltage amplitude. IGBT nonlinearities were observed to cause a smaller overshoot, in the order of 30%. This thesis introduces an improved ADUDT control method that is able to compensate for phase leg blanking times, giving flexibility to the pulse pattern structure and dead times. The control method is still sensitive to timing deviations, and their effect is investigated. A simple approach of using a fixed delay compensation value was tried in the test setup measurements. The ADUDT method with the new control algorithm was found to work in an actual motor drive application. Judging by the simulation results, with the delay compensation, the method should ultimately enable an output voltage performance and a du/dt reduction that are free from residual overshoot effects. The proposed control algorithm is not strictly required for successful ADUDT operation: It is possible to precalculate the pulse patterns by iteration and then for instance store them into a look-up table inside the control electronics. Rather, the newly developed control method is a mathematical tool for solving the ADUDT control pulses. It does not contain the timing deviation compensation (from the logic-level command to the phase leg output voltage), and as such is not able to remove the timing deviation effects that cause error and overshoot in the filter. When the timing deviation compensation has to be tuned-in in the control pattern, the precalculated iteration method could prove simpler and equally good (or even better) compared with the mathematical solution with a separate timing compensation module. One of the key findings in this thesis is the conclusion that the correctness of the pulse pattern structure, in the sense of ZCC and predicted pulse timings, cannot be separated from the timing deviations. The usefulness of the correctly calculated pattern is reduced by the voltage edge timing errors. The doctoral thesis provides an introductory background chapter on variable-speed AC drives and the problem of motor overvoltages and takes a look at traditional solutions for overvoltage mitigation. Previous results related to the active du/dt filtering are discussed. The basic operation principle and design of the filter have been studied previously. The effect of load current in the filter and the basic idea of compensation have been presented in the past. However, there was no direct way of including the dead time in the control (except for solving the pulse pattern manually by iteration), and the magnitude of nonlinearity effects had not been investigated. The enhanced control principle with the dead time handling capability and a case study of the test setup timing deviations are the main contributions of this doctoral thesis. The simulation and experimental setup results show that the proposed control method can be used in an actual drive. Loss measurements and a comparison of active du/dt output filtering with traditional output filtering methods are also presented in the work. Two different ADUDT filter designs are included, with ferrite core and air core inductors. Other filters included in the tests were a passive du/dtfilter and a passive sine filter. The loss measurements incorporated a silicon carbide diode-equipped IGBT module, and the results show lower losses with these new device technologies. The new control principle was measured in a 43 A load current motor drive system and was able to bring the filter output peak voltage from 980 V (the previous control principle) down to 680 V in a 540 V average DC link voltage variable-speed drive. A 200 m motor cable was used, and the filter losses for the active du/dt methods were 111W–126 W versus 184 W for the passive du/dt. In terms of inverter and filter losses, the active du/dt filtering method had a 1.82-fold increase in losses compared with an all-passive traditional du/dt output filter. The filter mass with the active du/dt method was 17% (2.4 kg, air-core inductors) compared with 14 kg of the passive du/dt method filter. Silicon carbide freewheeling diodes were found to reduce the inverter losses in the active du/dt filtering by 18% compared with the same IGBT module with silicon diodes. For a 200 m cable length, the average peak voltage at the motor terminals was 1050 V with no filter, 960 V for the all-passive du/dt filter, and 700 V for the active du/dt filtering applying the new control principle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kemira Chemicals Oy:n Joutsenon kloori-alkalitehtaalla valmistetaan elektrolyysin avulla lipeää, suolahappoa, natriumhypokloriittia ja vetyä. Tämän työn tavoitteena on kartoittaa kloori-alkalitehtaan tuotantokapasiteetin kasvatuksen yhteydessä esiin tulevat pullonkaulat, lähitulevaisuuden kunnossapitotarpeet sekä parhaat käytettävissä olevat teknologiavaihtoehdot kloori-alkalitehtaan osa-alueille, joihin tuotantokapasiteetin kasvatuspaineet kohdistuvat: elektrolyysi, lipeän haihdutus ja suolahappopolttimet. Pullonkaulojen kartoittaminen toteutettiin rakentamalla taulukkolaskentamalli kloori-alkalitehtaan prosesseista. Mallin avulla simuloitiin elektrolyysin kloorin tuotantoa, jota kasvatettiin asteittain 54 kt:sta/a aina 100 kt:iin/a asti ja tutkittiin prosessien käyttäytymistä. Tarkastelun pohjalta havaittiin, että kloorin tuotantoa kasvattaessa, tulee lisätä myös tuotantokapasiteettia suolahapon valmistukseen, elektrolyysiin, demineralisoidun veden valmistukseen ja lipeän haihdutuslaitokseen sekä suolahapon ja lipeän varastointikapasiteetteihin. Vaihtoehtoiset teknologiat määritettiin kirjallisuudesta ja laitetoimittajien esitteistä. Lähivuosien kunnossapitotarpeet kartoitettiin haastattelemalla tehtaan henkilökuntaa. Työstä eskaloitui useita jatkotutkimuskohteita, joita ovat bipolaari-teknologian soveltuvuus Joutsenon kloori-alkalitehtaalle, uusien HCl-polttimien esisuunnittelu, höyryn käytön tehostaminen nykyisessä lipeän haihdutuslaitoksessa sekä uusien haihdutusteknologioiden soveltuvuus Joutsenon kloori-alkalitehtaalle, höyry- ja jäähdytysverkostojen kartoitukset sekä demineralisoidun veden valmistuskapasiteetin kasvattaminen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä kandidaatintyössä selvitetään kirjallisuustutkimuksena, minkälaista tutkimusta maailmalla on tehty liittyen pienjännitteiseen tasasähkönjakeluun, sekä missä sovelluskohteissa sitä hyödynnetään. Työssä esitetään yleisimmät järjestelmärakenteet ja sovelluskohteet sekä organisaatiot, joiden on havaittu tutkivan tasasähkönjakelua kiinteistöissä, microgrideissä tai julkisessa sähkönjakelussa. Katsauksen perusteella havaittiin, että maailmalla on tehty erityisesti laskennallisia tutkimuksia ja simulointeja liittyen pienjännitteiseen tasasähkönjakeluun. Näkökulma on pääasiassa ollut kiinteistöissä ja microgrideissä, vähäisemmässä määrin myös julkisissa sähkönjakeluverkoissa. Pienjännitteistä tasasähkönjakelua hyödynnetään, tai ainakin voitaisiin hyödyntää näissä kohteissa. Pääasiassa konseptilla on pyritty hakemaan kustannussäästöjä ja toisaalta parantamaan hyötysuhdetta. Ympäri maailmaa on käynnissä pilottihankkeita sekä kiinteistöihin, että julkiseen sähkönjakeluun liittyen. Bipolaarinen ratkaisu näytti olevan yleisempi. Käytetyt ja tutkitut jännitetasot vaihtelivat riippuen sovelluskohteesta – kiinteistön sisällä oli käytössä tasot pienoisjännitteestä aina 350–400 VDC jännitetasoon asti, ja sama 350–400 VDC oli selvästi suosittu jännitealue myös jakeluverkossa, mutta myös korkeampia jännitteitä, kuten 700–750 VDC, oli käytössä.