8 resultados para Varroa sensitive hygiene

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary: Owncontrol directions in meat hygiene legislation and their practical implementation in the slaughterhouse and cutting plant of Snellman Ltd, part I

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hand hygiene compliance of patients receiving hemodialysis treatment is a contemporary discussion topic among health care professionals in the Nephrology Clinic of Helsinki University City Hospital. The purpose of the Final Thesis is to review patient hand hygiene in terms of risks its lack entails and based on the evidence based findings to design an end product as a poster. The poster can be utilised in the Nephrology Clinic's nursing environment to educate and motivate patients to pay specifid attention to the importance of hand hygiene. The method used was a systematic literature review. The most important evidence based findings were extracted from the chosen thirteen scientific articles. All articles were searched from the Cumulative Index to Nursing and Allied Health Literature electronic database. The gathered information was then used to build the content of a patient education tool that for this project was defined as a Poster. The findings in this study showed that transmission of bloodborne infections, like Hepatitis B or C virus can occur through a vascular access and that the consequences of this can be very fatal. Additionally, environmental surfaces such as furniture, door knobs and dialysis machine control knobs were all possible infection sources for the patient receiving hemodialysis treatment. Adherence to good hand hygiene behaviour lowered the risk for infections. The end product of this study is a poster that is targeted to patients undergoing hemodialysis treatment. Using a health promotion agenda in the Poster, it is hoped that patients will pay more attention to the importance of hand hygiene and that they will be more motivated to use aseptic methods such as alcohol based hand rubs in the hemodialysis setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to examine the current situation in substance abuse treatment units in Finland in taking non-Finnish speaking clients into consideration. The initiative for this research came from the Development of Alcohol and Drugs Intervention group at Stakes (National Research and Development Centre for Welfare and Health). Their aim was to gather information about the functioning and relevance of the quality assessment forms based on the quality recommendations for substance abuse work, filled in by substance abuse treatment units. The ethnic issue was chosen as the main approach in the study. The aim of this research was to answer the following questions: what is the readiness and competence in substance abuse treatment units in Finland to receive and encounter non-Finnish speaking clients, how is the quality of these services assessed and/or developed in the units, and what has been the role and functioning of the quality recommendations and quality assessment forms in working with non-Finnish speaking clients. The research methods used in the study were both quantitative and qualitative. The information concerning language services provided in the units was gathered from the quality assessment forms and basic information forms found in the database maintained by Stakes. The total amount of units found in the database was 267. In addition to that, semi-structured theme-interviews were carried out in four substance abuse treatment units in order to get a more deep understanding of how the services function in practice. The few number of non-Finnish speaking clients in the units may explain to a certain degree the results of the research. The results however showed that there is still space for improving the services. In the light of quality recommendations, the degree of language options provided in substance abuse treatment units in Finland today is low. Also the quantity of interpreter services provided in the units is scarce. There could also be unified guidelines specially tailored for substance abuse treatment units on how to work with ethnic minorities, as the knowledge is currently adopted from several different instances. The quality recommendations as well as quality assessment forms were valued and applied in the units appropriately and were also perceived to have an effect on the functioning, and quality, in the units.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiac troponins (cTns) are the recommended biochemical markers in the diagnosis of myocardial infarction (MI). They are very sensitive and tissue-specific but are limited by their delayed appearance in the circulation. Biochemical markers with more rapid release kinetics, e.g. myoglobin and especially heart-type fatty acid-binding protein (H-FABP), have been used to enhance the early identification of MI. The implementation of cTns into clinical practice has shown that cardiomyocyte injury occurs in many other clinical conditions than MI. The aim of this study was to evaluate the impact of modern and highly sensitive cTnI assays on the early diagnosis of MI. In a patient cohort with suspected MI, such a sensitive cTnI assay enhanced the early diagnostic accuracy when compared to a less sensitive cTnI assay and to myoglobin. When compared to H-FABP during the early hours after symptom onset, the sensitive cTnI assay showed at least similar and, after 6 hours, superior diagnostic accuracy. A positive cTnI test result had superior prognostic value when compared to H-FABP, even among early presenters. The prognostic value of cTn in acute heart failure (AHF) was evaluated in 364 patients who participated in the FINN-AKVA study. The patients presented with AHF but no acute coronary syndrome (ACS). Up to half of the patients had elevated cTn levels which were associated with higher 6-month mortality. The magnitude of cTn elevation was directly proportional to mortality. Finally, the clinical spectrum of cTnI elevations was evaluated in 991 cTnI positive emergency department (ED) patients. 83% of the patients had MI and 17% had cTnI elevation due to other clinical conditions. The latter patient group was characterized by lower absolute cTnI levels and – importantly – higher in-hospital mortality when compared to the MI patients. In conclusion, the use of a highly sensitive cTnI assay enhances the early diagnostic accuracy and risk stratification in suspected MI patients. Cardiac troponin elevations are highly prevalent also in other acute clinical conditions and indicate an adverse outcome of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine suitability of BimTwin cleaning concept in card board machine to control microbiological activity and describe microbiological balance of the machine. In a review of literature is examined microbe and spore caused problems in paper industry. Biggest problems are deposits, which decrease runnability and cause quality errors. In this chapter is also introduced most common oxidizing biocides used in paper industry and described ATP assay as a microbiological monitoring method. In an experimental part are included BimTwin mill trial results, chemical condition monitoring methods and microbiological balance in a card board machine. In a second part are examined possibilities to effect hygiene of card board by chemical treatment of the surface size and coating. Result showed that BimTwin concept is suitable for card board machine as a cleaning concept, when chemical dosing is fitted right. For proper dosing and secure tolerable hygiene level, chemical and microbiological monitoring is significant. Determining of the microbiological balance would have need more sampling. According to acquired results, broke turned out to be the biggest microbe source. Sizing and coating experiments showed that it is possible to improve hygiene of card board by chemically treated surface size and coating color.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Planar, large area, position sensitive silicon detectors are widely utilized in high energy physics research and in medical, computed tomography (CT). This thesis describes author's research work relating to development of such detector components. The key motivation and objective for the research work has been the development of novel, position sensitive detectors improving the performance of the instruments they are intended for. Silicon strip detectors are the key components of barrel-shaped tracking instruments which are typically the innermost structures of high energy physics experimental stations. Particle colliders such as the former LEP collider or present LHC produce particle collisions and the silicon strip detector based trackers locate the trajectories of particles emanating from such collisions. Medical CT has become a regular part of everyday medical care in all developed countries. CT scanning enables x-ray imaging of all parts of the human body with an outstanding structural resolution and contrast. Brain, chest and abdomen slice images with a resolution of 0.5 mm are possible and latest CT machines are able to image whole human heart between heart beats. The two application areas are presented shortly and the radiation detection properties of planar silicon detectors are discussed. Fabrication methods and preamplifier electronics of the planar detectors are presented. Designs of the developed, large area silicon detectors are presented and measurement results of the key operating parameters are discussed. Static and dynamic performance of the developed silicon strip detectors are shown to be very satisfactory for experimental physics applications. Results relating to the developed, novel CT detector chips are found to be very promising for further development and all key performance goals are met.