4 resultados para Ultra high vacuum system

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

SD card (Secure Digital Memory Card) is widely used in portable storage medium. Currently, latest researches on SD card, are mainly SD card controller based on FPGA (Field Programmable Gate Array). Most of them are relying on API interface (Application Programming Interface), AHB bus (Advanced High performance Bus), etc. They are dedicated to the realization of ultra high speed communication between SD card and upper systems. Studies about SD card controller, really play a vital role in the field of high speed cameras and other sub-areas of expertise. This design of FPGA-based file systems and SD2.0 IP (Intellectual Property core) does not only exhibit a nice transmission rate, but also achieve the systematic management of files, while retaining a strong portability and practicality. The file system design and implementation on a SD card covers the main three IP innovation points. First, the combination and integration of file system and SD card controller, makes the overall system highly integrated and practical. The popular SD2.0 protocol is implemented for communication channels. Pure digital logic design based on VHDL (Very-High-Speed Integrated Circuit Hardware Description Language), integrates the SD card controller in hardware layer and the FAT32 file system for the entire system. Secondly, the document management system mechanism makes document processing more convenient and easy. Especially for small files in batch processing, it can ease the pressure of upper system to frequently access and process them, thereby enhancing the overall efficiency of systems. Finally, digital design ensures the superior performance. For transmission security, CRC (Cyclic Redundancy Check) algorithm is for data transmission protection. Design of each module is platform-independent of macro cells, and keeps a better portability. Custom integrated instructions and interfaces may facilitate easily to use. Finally, the actual test went through multi-platform method, Xilinx and Altera FPGA developing platforms. The timing simulation and debugging of each module was covered. Finally, Test results show that the designed FPGA-based file system IP on SD card can support SD card, TF card and Micro SD with 2.0 protocols, and the successful implementation of systematic management for stored files, and supports SD bus mode. Data read and write rates in Kingston class10 card is approximately 24.27MB/s and 16.94MB/s.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In modern society, the body health is a very important issue to everyone. With the development of the science and technology, the new and developed body health monitoring device and technology will play the key role in the daily medical activities. This paper focus on making progress in the design of the wearable vital sign system. A vital sign monitoring system has been proposed and designed. The whole detection system is composed of signal collecting subsystem, signal processing subsystem, short-range wireless communication subsystem and user interface subsystem. The signal collecting subsystem is composed of light source and photo diode, after emiting light of two different wavelength, the photo diode collects the light signal reflected by human body tissue. The signal processing subsystem is based on the analog front end AFE4490 and peripheral circuits, the collected analog signal would be filtered and converted into digital signal in this stage. After a series of processing, the signal would be transmitted to the short-range wireless communication subsystem through SPI, this subsystem is mainly based on Bluetooth 4.0 protocol and ultra-low power System on Chip(SoC) nRF51822. Finally, the signal would be transmitted to the user end. After proposing and building the system, this paper focus on the research of the key component in the system, that is, the photo detector. Based on the study of the perovskite materials, a low temperature processed photo detector has been proposed, designed and researched. The device is made up of light absorbing layer, electron transporting and hole blocking layer, hole transporting and electron blocking layer, conductive substrate layer and metal electrode layer. The light absorbing layer is the important part of whole device, and it is fabricated by perovskite materials. After accepting the light, the electron-hole pair would be produced in this layer, and due to the energy level difference, the electron and hole produced would be transmitted to metal electrode and conductive substrate electrode through electron transporting layer and hole transporting layer respectively. In this way the response current would be produced. Based on this structure, the specific fabrication procedure including substrate cleaning; PEDOT:PSS layer preparation; pervoskite layer preparation; PCBM layer preparation; C60, BCP, and Ag electrode layer preparation. After the device fabrication, a series of morphological characterization and performance testing has been done. The testing procedure including film-forming quality inspection, response current and light wavelength analysis, linearity and response time and other optical and electrical properties testing. The testing result shows that the membrane has been fabricated uniformly; the device can produce obvious response current to the incident light with the wavelength from 350nm to 800nm, and the response current could be changed along with the light wavelength. When the light wavelength keeps constant, there exists a good linear relationship between the intensity of the response current and the power of the incident light, based on which the device could be used as the photo detector to collect the light information. During the changing period of the light signal, the response time of the device is several microseconds, which is acceptable working as a photo detector in our system. The testing results show that the device has good electronic and optical properties, and the fabrication procedure is also repeatable, the properties of the devices has good uniformity, which illustrates the fabrication method and procedure could be used to build the photo detector in our wearable system. Based on a series of testing results, the paper has drawn the conclusion that the photo detector fabricated could be integrated on the flexible substrate and is also suitable for the monitoring system proposed, thus made some progress on the research of the wearable monitoring system and device. Finally, some future prospect in system design aspect and device design and fabrication aspect are proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tämän diplomityön tarkoituksena on kehittää menetelmä, jolla voidaan seurata inhalaatiovalmisteen sisältämiä epäpuhtauksia. Menetelmä kehitetään erittäin korkean suorituskyvyn kromatografialaitteistolle (Ultra High Performance Liquid Chromatography, UHPLC) jo olemassa olevan HPLC-epäpuhtausmenetelmän pohjalta. Uusi menetelmä kehitetään analyysiajan lyhentämiseksi ja erotuksen resoluution parantamiseksi. Työn kirjallisuusosa esittelee lyhyesti inhalaatiovalmisteet sekä nestekromatografian perusteet. Korkean erotuskyvyn nestekromatografia ja analysoinnin apuna käytettävät parametrit selvitetään laskukaavoineen. Kirjallisuusosa keskittyy epäpuhtausmenetelmän kehittämisen kulkuun ja menetelmän validoinnissa suoritettaviin kokeisiin. Soveltavassa osassa Orion Oyj:n kehitteillä olevalle kahden vaikuttavan aineen inhalaatiovalmisteelle kehitetään UHPLC-epäpuhtausmenetelmä kirjallisuusosiossa esitellyn menetelmäkehitysrungon pohjalta. Menetelmäkehityksen kulku ja analyysin olosuhteiden valinta esitellään pääpiirteittäin, jonka jälkeen kehitetty menetelmä validoidaan sille tehdyn validointisuunnitelman mukaisesti. Kehitetystä UHPLC-epäpuhtausmenetelmästä saatiin 16 minuuttia lyhyempi kuin vastaava HPLC-epäpuhtausmenetelmä. Myös analyysin resoluutio parantui merkittävästi. Toistuvien injektioiden jälkeen kromatogrammissa esiintyi kuitenkin häntimistä, joka johti merkittävään resoluution heikkenemiseen. Häntimisen syyksi epäiltiin toisen vaikuttavan aineen kiinnittymistä kolonnimateriaaliin, mutta sen estämiseksi ehdotetut toimenpiteet eivät sopineet kehitettyyn menetelmään.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Kandidaatintyön tarkoituksena oli selvittää pienahitsin juuren kriittisyyttä. Työ oli saanut aiheen rakenneputki kokeiden yhteydessä tehdyistä havainnoista. Työssä tutustuttiin millaiset ovat pienahitsin mitoitus menetelmät ja tausta tutkimusta kuinka sitä sovelletaan käytäntöön suurlujuusteräksille. Työssä esitellään käytetyt tutkimusmenetelmät kuinka menetelmätriangulaatio saavutettiin. Tutkimuskysymyksenä oli hitsien kestävyyden mitoituksen riittävyys. Tutkimukset suoritettiin tarkastellen staattisesti kuormitettuja pienahitsejä. Pienahitsi kappaleista tehtiin laboratoriokoekappale ja FEM-laskentamalli joista vertailtiin tuloksia. Laboratoriokokeessa mittaus menetelmänä käytettiin DIC-mittausta, jolle voitiin tehdä jälkikäsittelyjä ja sieltä määrittää haluttuja datapisteitä. Laskennassa suurimmat jännityskeskittymät syntyivät hitsin kohdalle mutta vetokokeessa koekappaleeseen syntyi vauriot sularajalle ja vetokorvakkeen kiinnityshitsin rajaviivalle. Tällä kohtaa todettiin materiaalimalli riittämättömäksi, koska siihen ei ollut määritelty muutosvyöhykkeen parametreja.