5 resultados para Televisión por cable-Costos

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays typical motor junction boxes do not incorporate cable glands, which would provide good electrical performance interms of electromagnetic compatibility. In this paper, a manufacturability and assembly analysis for the new construction of a rigid body feeder cable junction of an electric motor is presented especially for converter drives (practical tests were carried out at LUT during 2007). Although the cable junction should also clamp the cable to provide enough tensile strength, the phase conductors should not get squashed by the groundingconnection. In order to ensure good performance in an electrical mean especially in converter drives, the grounding of the cable should be connected 360 degrees around the cable. In this paper, following manufacturing technologies are discussed: traditional turning, precision and centrifugal casting, and rotation moulding. DFM(A)-aspects are presented in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demand for electricity is constantly growing in contemporary world and, in the same time, quality and reliability requirements are becoming more rigid. In addition, renewable sources of energy have been widely introduced for power generation, and they create specific challenges for the network. Consequently, new solution for distribution system is required, and Low Voltage Direct Current (LVDC) system is the proposed one. This thesis focuses on the investigation of specific cable features for low voltage direct current (LVDC) distribution system. The LVDC system is public ±750 VDC distribution system, which is currently being developed at Lappeen-ranta University of Technology. The aspects, considered in the thesis, are reliable and economic power transmission in distribution networks and possible power line communication in the LVDC cable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this master’s thesis is to develop an algorithm to calculate the cable network for heat and power station CHGRES. This algorithm includes important aspect which has an influence on the cable network reliability. Moreover, according to developed algorithm, the optimal solution for modernization cable system from economical and technical point of view was obtained. The conditions of existing cable lines show that replacement is necessary. Otherwise, the fault situation would happen. In this case company would loss not only money but also its prestige. As a solution, XLPE single core cables are more profitable than other types of cable considered in this work. Moreover, it is presented the dependence of value of short circuit current on number of 10/110 kV transformers connected in parallel between main grid and considered 10 kV busbar and how it affects on final decision. Furthermore, the losses of company in power (capacity) market due to fault situation are presented. These losses are commensurable with investment to replace existing cable system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent Storms in Nordic countries were a reason of long power outages in huge territories. After these disasters distribution networks' operators faced with a problem how to provide adequate quality of supply in such situation. The decision of utilization cable lines rather than overhead lines were made, which brings new features to distribution networks. The main idea of this work is a complex analysis of medium voltage distribution networks with long cable lines. High value of cable’s specific capacitance and length of lines determine such problems as: high values of earth fault currents, excessive amount of reactive power flow from distribution to transmission network, possibility of a high voltage level at the receiving end of cable feeders. However the core tasks was to estimate functional ability of the earth fault protection and the possibility to utilize simplified formulas for operating setting calculations in this network. In order to provide justify solution or evaluation of mentioned above problems corresponding calculations were made and in order to analyze behavior of relay protection principles PSCAD model of the examined network have been created. Evaluation of the voltage rise in the end of a cable line have educed absence of a dangerous increase in a voltage level, while excessive value of reactive power can be a reason of final penalty according to the Finish regulations. It was proved and calculated that for this networks compensation of earth fault currents should be implemented. In PSCAD models of the electrical grid with isolated neutral, central compensation and hybrid compensation were created. For the network with hybrid compensation methodology which allows to select number and rated power of distributed arc suppression coils have been offered. Based on the obtained results from experiments it was determined that in order to guarantee selective and reliable operation of the relay protection should be utilized hybrid compensation with connection of high-ohmic resistor. Directional and admittance based relay protection were tested under these conditions and advantageous of the novel protection were revealed. However, for electrical grids with extensive cabling necessity of a complex approach to the relay protection were explained and illustrated. Thus, in order to organize reliable earth fault protection is recommended to utilize both intermittent and conventional relay protection with operational settings calculated by the use of simplified formulas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This final project was made for the Broadband/Implementation department of TeliaSonera Finland. The question to be examined is if the operator should replace multiple ADSL connections implemented over a leased line with Multi-Dwelling access based on an Ethernet/Optical Fibre access network. The project starts with describing the technology related to these access network solu-tions and presents the technology that is used in TeliaSonera Finland's access network. It continues from the technology to describe the problem with some of the ADSL implemen-tations of TeliaSonera. The problem is the implementations done over a leased line that can cost TeliaSonera over years as much as a possible investment to extend network when there is several lines leased to the same building. The project proposes a Multi-Dwelling access as a solution to this problem and defines the circumstances when to use it. After a satisfactory solution has found the project takes a view how implementation of the solution might alter the network and a new problem is found. When used commonly to replace need of ADSL implementation Multi-Dwelling access would significantly increase optical cable congestion near operators POP. As a final deed this project also proposes a technical change to existing way to implement multi-dwelling access with EPON technology.