15 resultados para TIME-RESOLVED SAXS

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Master's thesis is devoted to semiconductor samples study using time-resolved photoluminescence. This method allows investigating recombination in semiconductor samples in order to develop quality of optoelectronic device. An additional goal was the method accommodation for low-energy-gap materials. The first chapter gives a brief intercourse into the basis of semiconductor physics. The key features of the investigated structures are noted. The usage area of the results covers saturable semiconductor absorber mirrors, disk lasers and vertical-external-cavity surface-emittinglasers. The experiment set-up is described in the second chapter. It is based on up-conversion procedure using a nonlinear crystal and involving the photoluminescent emission and the gate pulses. The limitation of the method was estimated. The first series of studied samples were grown at various temperatures and they suffered rapid thermal annealing. Further, a latticematched and metamorphically grown samples were compared. Time-resolved photoluminescence method was adapted for wavelengths up to 1.5 µm. The results allowed to specify the optimal substrate temperature for MBE process. It was found that the lattice-matched sample and the metamorphically grown sample had similar characteristics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Streptavidin, a tetrameric protein secreted by Streptomyces avidinii, binds tightly to a small growth factor biotin. One of the numerous applications of this high-affinity system comprises the streptavidin-coated surfaces of bioanalytical assays which serve as universal binders for straightforward immobilization of any biotinylated molecule. Proteins can be immobilized with a lower risk of denaturation using streptavidin-biotin technology in contrast to direct passive adsorption. The purpose of this study was to characterize the properties and effects of streptavidin-coated binding surfaces on the performance of solid-phase immunoassays and to investigate the contributions of surface modifications. Various characterization tools and methods established in the study enabled the convenient monitoring and binding capacity determination of streptavidin-coated surfaces. The schematic modeling of the monolayer surface and the quantification of adsorbed streptavidin disclosed the possibilities and the limits of passive adsorption. The defined yield of 250 ng/cm2 represented approximately 65 % coverage compared with a modelled complete monolayer, which is consistent with theoretical surface models. Modifications such as polymerization and chemical activation of streptavidin resulted in a close to 10-fold increase in the biotin-binding densities of the surface compared with the regular streptavidin coating. In addition, the stability of the surface against leaching was improved by chemical modification. The increased binding densities and capacities enabled wider high-end dynamic ranges in the solid-phase immunoassays, especially when using the fragments of the capture antibodies instead of intact antibodies for the binding of the antigen. The binding capacity of the streptavidin surface was not, by definition, predictive of the low-end performance of the immunoassays nor the assay sensitivity. Other features such as non-specific binding, variation and leaching turned out to be more relevant. The immunoassays that use a direct surface readout measurement of time-resolved fluorescence from a washed surface are dependent on the density of the labeled antibodies in a defined area on the surface. The binding surface was condensed into a spot by coating streptavidin in liquid droplets into special microtiter wells holding a small circular indentation at the bottom. The condensed binding area enabled a denser packing of the labeled antibodies on the surface. This resulted in a 5 - 6-fold increase in the signal-to-background ratios and an equivalent improvement in the detection limits of the solid-phase immunoassays. This work proved that the properties of the streptavidin-coated surfaces can be modified and that the defined properties of the streptavidin-based immunocapture surfaces contribute to the performance of heterogeneous immunoassays.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The central goal of food safety policy in the European Union (EU) is to protect consumer health by guaranteeing a high level of food safety throughout the food chain. This goal can in part be achieved by testing foodstuffs for the presence of various chemical and biological hazards. The aim of this study was to facilitate food safety testing by providing rapid and user-friendly methods for the detection of particular food-related hazards. Heterogeneous competitive time-resolved fluoroimmunoassays were developed for the detection of selected veterinary residues, that is coccidiostat residues, in eggs and chicken liver. After a simplified sample preparation procedure, the immunoassays were performed either in manual format with dissociation-enhanced measurement or in automated format with pre-dried assay reagents and surface measurement. Although the assays were primarily designed for screening purposes providing only qualitative results, they could also be used in a quantitative mode. All the developed assays had good performance characteristics enabling reliable screening of samples at concentration levels required by the authorities. A novel polymerase chain reaction (PCR)-based assay system was developed for the detection of Salmonella spp. in food. The sample preparation included a short non-selective pre-enrichment step, after which the target cells were collected with immunomagnetic beads and applied to PCR reaction vessels containing all the reagents required for the assay in dry form. The homogeneous PCR assay was performed with a novel instrument platform, GenomEra, and the qualitative assay results were automatically interpreted based on end-point time-resolved fluorescence measurements and cut-off values. The assay was validated using various food matrices spiked with sub-lethally injured Salmonella cells at levels of 1-10 colony forming units (CFU)/25 g of food. The main advantage of the system was the exceptionally short time to result; the entire process starting from the pre-enrichment and ending with the PCR result could be completed in eight hours. In conclusion, molecular methods using state-of-the-art assay techniques were developed for food safety testing. The combination of time-resolved fluorescence detection and ready-to-use reagents enabled sensitive assays easily amenable to automation. Consequently, together with the simplified sample preparation, these methods could prove to be applicable in routine testing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent years, one important objective of cardiovascular research has been to find new markers that would improve the risk stratification and diagnosis of patients presenting with symptoms of acute coronary syndrome (ACS). Pregnancy-associated plasma protein A (PAPP-A) is a large metalloproteinase involved in insulin-like growth factor signalling. It is expressed in various tissues and seems to be involved in many physiological and pathological processes, such as folliculogenesis, bone formation, wound healing, pregnancy and atherosclerosis. The aim of this thesis was to investigate PAPP-A in ACS patients. Circulating concentrations of PAPP-A had been previously shown to be elevated in ACS. In this study it was revealed that the form of PAPP-A causing this elevation was the free noncomplexed PAPP-A. Thus, the form of PAPP-A in the circulation of ACS patients differed from the complexed PAPP-A form abundantly present in the circulation during pregnancy. A point-of-care method based on time-resolved immunofluorometric assays was developed, which enabled the rapid detection of free PAPP-A. The method was found to perform well with serum and heparin plasma samples as well as with heparinized whole blood samples. With this method the concentrations of free PAPP-A in healthy individuals were shown to be negligible. When the clinical performance of the method was evaluated with serum samples from ACS patients, it was shown that the free PAPP-A concentration in the admission sample was an independent predictor of myocardial infarction and death. Moreover, as a prognostic marker, free PAPP-A was revealed to be superior to total PAPPA, i.e. the combination of free and complexed PAPP-A, which has been measured by the other groups in this field. As heparin products are widely used as medication in ACS patients, the effect of heparin products on free PAPP-A molecule and circulating concentrations were also investigated in this study. It was shown that intravenous administration of low molecular weight or unfractionated heparin elicits a rapid release of free PAPP-A into the circulation in haemodialysis patients and patients undergoing angiography. Moreover, the interaction between PAPP-A and heparin was confirmed in gel filtration studies. Importantly, the patients included in the clinical evaluation of the free PAPP-A detection method developed had not received any heparin product medication before the admission sample and thus the results were not affected by the heparin effect. In conclusion, free PAPP-A was identified as a novel marker associated with ACS. The point-of-care methods developed enable rapid detection of this molecule which predicts adverse outcome when measured in the admission sample of ACS patients. However, the effect revealed of heparin products on circulating PAPP-A concentrations should be acknowledged when further studies are conducted related to free or total PAPP-A in ACS.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The drug discovery process is facing new challenges in the evaluation process of the lead compounds as the number of new compounds synthesized is increasing. The potentiality of test compounds is most frequently assayed through the binding of the test compound to the target molecule or receptor, or measuring functional secondary effects caused by the test compound in the target model cells, tissues or organism. Modern homogeneous high-throughput-screening (HTS) assays for purified estrogen receptors (ER) utilize various luminescence based detection methods. Fluorescence polarization (FP) is a standard method for ER ligand binding assay. It was used to demonstrate the performance of two-photon excitation of fluorescence (TPFE) vs. the conventional one-photon excitation method. As result, the TPFE method showed improved dynamics and was found to be comparable with the conventional method. It also held potential for efficient miniaturization. Other luminescence based ER assays utilize energy transfer from a long-lifetime luminescent label e.g. lanthanide chelates (Eu, Tb) to a prompt luminescent label, the signal being read in a time-resolved mode. As an alternative to this method, a new single-label (Eu) time-resolved detection method was developed, based on the quenching of the label by a soluble quencher molecule when displaced from the receptor to the solution phase by an unlabeled competing ligand. The new method was paralleled with the standard FP method. It was shown to yield comparable results with the FP method and found to hold a significantly higher signal-tobackground ratio than FP. Cell-based functional assays for determining the extent of cell surface adhesion molecule (CAM) expression combined with microscopy analysis of the target molecules would provide improved information content, compared to an expression level assay alone. In this work, immune response was simulated by exposing endothelial cells to cytokine stimulation and the resulting increase in the level of adhesion molecule expression was analyzed on fixed cells by means of immunocytochemistry utilizing specific long-lifetime luminophore labeled antibodies against chosen adhesion molecules. Results showed that the method was capable of use in amulti-parametric assay for protein expression levels of several CAMs simultaneously, combined with analysis of the cellular localization of the chosen adhesion molecules through time-resolved luminescence microscopy inspection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lanthanides represent the chemical elements from lanthanum to lutetium. They intrinsically exhibit some very exciting photophysical properties, which can be further enhanced by incorporating the lanthanide ion into organic or inorganic sensitizing structures. A very popular approach is to conjugate the lanthanide ion to an organic chromophore structure forming lanthanide chelates. Another approach, which has quickly gained interest, is to incorporate the lanthanide ions into nanoparticle structures, thus attaining improved specific activity and binding capacity. The lanthanide-based reporters usually express strong luminescence emission, multiple narrow emission lines covering a wide wavelength range, and exceptionally long excited state lifetimes enabling timeresolved detection. Because of these properties, the lanthanide-based reporters have found widespread applications in various fields of life. This study focuses on the field of bioanalytical applications. The aim of the study was to demonstrate the utility of different lanthanide-based reporters in homogeneous Förster resonance energy transfer (FRET)-based bioaffinity assays. Several different model assays were constructed. One was a competitive bioaffinity assay that utilized energy transfer from lanthanide chelate donors to fluorescent protein acceptors. In addition to the conventional FRET phenomenon, a recently discovered non-overlapping FRET (nFRET) phenomenon was demonstrated for the first time for fluorescent proteins. The lack of spectral overlap in the nFRET mechanism provides sensitivity and versatility to energy transfer-based assays. The distance and temperature dependence of these phenomena were further studied in a DNA-hybridization assay. The distance dependence of nFRET deviated from that of FRET, and unlike FRET, nFRET demonstrated clear temperature dependence. Based on these results, a possible excitation mechanism operating in nFRET was proposed. In the study, two enzyme activity assays for caspase-3 were also constructed. One of these was a fluorescence quenching-based enzyme activity assay that utilized novel inorganic particulate reporters called upconverting phosphors (UCPs) as donors. The use of UCPs enabled the construction of a simple, rather inexpensive, and easily automated assay format that had a high throughput rate. The other enzyme activity assay took advantage of another novel reporter class, the lanthanidebinding peptides (LBPs). In this assay, energy was transferred from a LBP to a green fluorescent protein (GFP). Using the LBPs it was possible to avoid the rather laborious, often poorly repeatable, and randomly positioned chemical labeling. In most of the constructed assays, time-resolved detection was used to eliminate the interfering background signal caused by autofluorescence. The improved signal-to-background ratios resulted in increased assay sensitivity, often unobtainable in homogeneous assay formats using conventional organic fluorophores. The anti-Stokes luminescence of the UCPs, however, enabled the elimination of autofluorescence even without time-gating, thus simplifying the instrument setup. Together, the studied reporters and assay formats pave the way for increasingly sensitive, simple, and easily automated bioanalytical applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Information gained from the human genome project and improvements in compound synthesizing have increased the number of both therapeutic targets and potential lead compounds. This has evolved a need for better screening techniques to have a capacity to screen number of compound libraries against increasing amount of targets. Radioactivity based assays have been traditionally used in drug screening but the fluorescence based assays have become more popular in high throughput screening (HTS) as they avoid safety and waste problems confronted with radioactivity. In comparison to conventional fluorescence more sensitive detection is obtained with time-resolved luminescence which has increased the popularity of time-resolved fluorescence resonance energy transfer (TR-FRET) based assays. To simplify the current TR-FRET based assay concept the luminometric homogeneous single-label utilizing assay technique, Quenching Resonance Energy Transfer (QRET), was developed. The technique utilizes soluble quencher to quench non-specifically the signal of unbound fraction of lanthanide labeled ligand. One labeling procedure and fewer manipulation steps in the assay concept are saving resources. The QRET technique is suitable for both biochemical and cell-based assays as indicated in four studies:1) ligand screening study of β2 -adrenergic receptor (cell-based), 2) activation study of Gs-/Gi-protein coupled receptors by measuring intracellular concentration of cyclic adenosine monophosphate (cell-based), 3) activation study of G-protein coupled receptors by observing the binding of guanosine-5’-triphosphate (cell membranes), and 4) activation study of small GTP binding protein Ras (biochemical). Signal-to-background ratios were between 2.4 to 10 and coefficient of variation varied from 0.5 to 17% indicating their suitability to HTS use.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The number of molecular diagnostic assays has increased tremendously in recent years.Nucleic acid diagnostic assays have been developed, especially for the detection of human pathogenic microbes and genetic markers predisposing to certain diseases. Closed-tube methods are preferred because they are usually faster and easier to perform than heterogenous methods and in addition, target nucleic acids are commonly amplified leading to risk of contamination of the following reactions by the amplification product if the reactions are opened. The present study introduces a new closed-tube switchable complementation probes based PCR assay concept where two non-fluorescent probes form a fluorescent lanthanide chelate complex in the presence of the target DNA. In this dual-probe PCR assay method one oligonucleotide probe carries a non-fluorescent lanthanide chelate and another probe a light absorbing antenna ligand. The fluorescent lanthanide chelate complex is formed only when the non-fluorescent probes are hybridized to adjacent positions into the target DNA bringing the reporter moieties in close proximity. The complex is formed by self-assembled lanthanide chelate complementation where the antenna ligand is coordinated to the lanthanide ion captured in the chelate. The complementation probes based assays with time-resolved fluorescence measurement showed low background signal level and hence, relatively high nucleic acid detection sensitivity (low picomolar target concentration). Different lanthanide chelate structures were explored and a new cyclic seven dentate lanthanide chelate was found suitable for complementation probe method. It was also found to resist relatively high PCR reaction temperatures, which was essential for the PCR assay applications. A seven-dentate chelate with two unoccupied coordination sites must be used instead of a more stable eight- or nine-dentate chelate because the antenna ligand needs to be coordinated to the free coordination sites of the lanthanide ion. The previously used linear seven-dentate lanthanide chelate was found to be unstable in PCR conditions and hence, the new cyclic chelate was needed. The complementation probe PCR assay method showed high signal-to-background ratio up to 300 due to a low background fluorescence level and the results (threshold cycles) in real-time PCR were reached approximately 6 amplification cycles earlier compared to the commonly used FRET-based closed-tube PCR method. The suitability of the complementation probe method for different nucleic acid assay applications was studied. 1) A duplex complementation probe C. trachomatis PCR assay with a simple 10-minute urine sample preparation was developed to study suitability of the method for clinical diagnostics. The performance of the C. trachomatis assay was equal to the commercial C. trachomatis nucleic acid amplification assay containing more complex sample preparation based on DNA extraction. 2) A PCR assay for the detection of HLA-DQA1*05 allele, that is used to predict the risk of type 1 diabetes, was developed to study the performance of the method in genotyping. A simple blood sample preparation was used where the nucleic acids were released from dried blood sample punches using high temperature and alkaline reaction conditions. The complementation probe HLA-DQA1*05 PCR assay showed good genotyping performance correlating 100% with the routinely used heterogenous reference assay. 3) To study the suitability of the complementation probe method for direct measurement of the target organism, e.g., in the culture media, the complementation probes were applied to amplificationfree closed-tube bacteriophage quantification by measuring M13 bacteriophage ssDNA. A low picomolar bacteriophage concentration was detected in a rapid 20- minute assay. The assay provides a quick and reliable alternative to the commonly used and relatively unreliable UV-photometry and time-consuming culture based bacteriophage detection methods and indicates that the method could also be used for direct measurement of other micro-organisms. The complementation probe PCR method has a low background signal level leading to a high signal-to-background ratio and relatively sensitive nucleic acid detection. The method is compatible with simple sample preparation and it was shown to tolerate residues of urine, blood, bacteria and bacterial culture media. The common trend in nucleic acid diagnostics is to create easy-to-use assays suitable for rapid near patient analysis. The complementation probe PCR assays with a brief sample preparation should be relatively easy to automate and hence, would allow the development of highperformance nucleic acid amplification assays with a short overall assay time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Binary probes are oligonucleotide probe pairs that hybridize adjacently to a complementary target nucleic acid. In order to detect this hybridization, the two probes can be modified with, for example, fluorescent molecules, chemically reactive groups or nucleic acid enzymes. The benefit of this kind of binary probe based approach is that the hybridization elicits a detectable signal which is distinguishable from background noise even though unbound probes are not removed by washing before measurement. In addition, the requirement of two simultaneous binding events increases specificity. Similarly to binary oligonucleotide probes, also certain enzymes and fluorescent proteins can be divided into two parts and used in separation-free assays. Split enzyme and fluorescent protein reporters have practical applications among others as tools to investigate protein-protein interactions within living cells. In this study, a novel label technology, switchable lanthanide luminescence, was introduced and used successfully in model assays for nucleic acid and protein detection. This label technology is based on a luminescent lanthanide chelate divided into two inherently non-luminescent moieties, an ion carrier chelate and a light harvesting antenna ligand. These form a highly luminescent complex when brought into close proximity; i.e., the label moieties switch from a dark state to a luminescent state. This kind of mixed lanthanide complex has the same beneficial photophysical properties as the more typical lanthanide chelates and cryptates - sharp emission peaks, long emission lifetime enabling time-resolved measurement, and large Stokes’ shift, which minimize the background signal. Furthermore, the switchable lanthanide luminescence technique enables a homogeneous assay set-up. Here, switchable lanthanide luminescence label technology was first applied to sensitive, homogeneous, single-target nucleic acid and protein assays with picomolar detection limits and high signal to background ratios. Thereafter, a homogeneous four-plex nucleic acid array-based assay was developed. Finally, the label technology was shown to be effective in discrimination of single nucleotide mismatched targets from fully matched targets and the luminescent complex formation was analyzed more thoroughly. In conclusion, this study demonstrates that the switchable lanthanide luminescencebased label technology can be used in various homogeneous bioanalytical assays.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An aging population and increasing rates of diabetes mellitus contribute to a high prevalence of kidney dysfunction – approximately 10 percent of adults in developed countries have chronic kidney disease (CKD). CKD is a progressive loss of kidney function and this remains permanent. Early recognition of this condition is important for prevention or impeding severe adverse cardiac and renal outcomes. Cystatin C is a low molecular weight cysteine protease inhibitor that has emerged as a biomarker of kidney function. The special potential of plasma cystatin C in this setting is related to its independency of muscle mass, which is a remarkable limitation of the traditional marker creatinine. Cystatin C is a sensitive marker in diagnosing mild and moderate CKD, especially in small children, in the elderly and in conditions where muscle mass is affected. Cystatin C is quantified with immunoassays, mainly based on particle-enhanced nephelometry (PENIA) or turbidimetry (PETIA). The aim of this study was to develop a rapid and reliable assay for quantification of human cystatin C in plasma or serum by utilizing time-resolved fluorescence-based immunoassay methods. This was accomplished by utilizing different antibodies, including polyclonal and 7 monoclonal antibodies against cystatin C. Different assay designs were tested and the best assay was further modified to a dry-reagent double monoclonal assay run on an automated immunonalyzer. This assay was evaluated for clinical performance in estimating reduced kidney function and in predicting risk of adverse outcomes in patients with non-ST elevation acute coronary syndrome. Of the tested assay designs, heterogeneous non-competitive assay had the best performace and was chosen to be developed further. As an automated double monoclonal assay, this assay enabled a reliable measurement of clinically relevant cystatin C concentrations. It also showed a stronger concordance with the reference clearance method than the conventional PETIA method in patients with reduced kidney function. Risk of all-cause mortality and combined events, defined by death and myocardial infarction, increased with higher cystatin C and cystatin C remained an independent predictor of death and combined events after adjustment to nonbiochemical baseline factors. In conclusion, the developed dry-reagent double monoclonal assay allows rapid and reliable quantitative measurement of cystatin C. As measured with the developed assay, cystatin C is a potential predictor of adverse outcomes in cardiac patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Prostate cancer is a heterogeneous disease affecting an increasing number of men all over the world, but particularly in the countries with the Western lifestyle. The best biomarker assay currently available for the diagnosis of the disease, the measurement of prostate specific antigen (PSA) levels from blood, lacks specificity, and even when combined with invasive tests such as digital rectal exam and prostate tissue biopsies, these methods can both miss cancers, and lead to overdiagnosis and subsequent overtreatment of cancers. Moreover, they cannot provide an accurate prognosis for the disease. Due to the high prevalence of indolent prostate cancers, the majority of men affected by prostate cancer would be able to live without any medical intervention. Their latent prostate tumors would not cause any clinical symptoms during their lifetime, but few are willing to take the risk, as currently there are no methods or biomarkers to reliably differentiate the indolent cancers from the aggressive, lethal cases that really are in need of immediate medical treatment. This doctoral work concentrated on validating 12 novel candidate genes for use as biomarkers for prostate cancer by measuring their mRNA expression levels in prostate tissue and peripheral blood of men with cancer as well as unaffected individuals. The panel of genes included the most prominent markers in the current literature: PCA3 and the fusion gene TMPRSS2-ERG, in addition to BMP-6, FGF-8b, MSMB, PSCA, SPINK1, and TRPM8; and the kallikrein-related peptidase genes 2, 3, 4, and 15. Truly quantitative reverse-transcription PCR assays were developed for each of the genes for the purpose, time-resolved fluorometry was applied in the real-time detection of the amplification products, and the gene expression data were normalized by using artificial internal RNA standards. Cancer-related, statistically significant differences in gene transcript levels were found for TMPRSS2-ERG, PCA3, and in a more modest scale, for KLK15, PSCA, and SPINK1. PCA3 RNA was found in the blood of men with metastatic prostate cancer, but not in localized cases of cancer, suggesting limitations for using this method for early cancer detection in blood. TMPRSS2-ERG mRNA transcripts were found more frequently in cancerous than in benign prostate tissues, but they were present also in 51% of the histologically benign prostate tissues of men with prostate cancer, while being absent in specimens from men without any signs of prostate cancer. PCA3 was shown to be 5.8 times overexpressed in cancerous tissue, but similarly to the fusion gene mRNA, its levels were upregulated also in the histologically benign regions of the tissue if the corresponding prostate was harboring carcinoma. These results indicate a possibility to utilize these molecular assays to assist in prostate cancer risk evaluation especially in men with initially histologically negative biopsies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Measuring protein biomarkers from sample matrix, such as plasma, is one of the basic tasks in clinical diagnostics. Bioanalytical assays used for the measuring should be able to measure proteins with high sensitivity and specificity. Furthermore, multiplexing capability would also be advantageous. To ensure the utility of the diagnostic test in point-of-care setting, additional requirements such as short turn-around times, ease-ofuse and low costs need to be met. On the other hand, enhancement of assay sensitivity could enable exploiting novel biomarkers, which are present in very low concentrations and which the current immunoassays are unable to measure. Furthermore, highly sensitive assays could enable the use of minimally invasive sampling. In the development of high-sensitivity assays the label technology and affinity binders are in pivotal role. Additionally, innovative assay designs contribute to the obtained sensitivity and other characteristics of the assay as well as its applicability. The aim of this thesis was to study the impact of assay components on the performance of both homogeneous and heterogeneous assays. Applicability of two different lanthanide-based label technologies, upconverting nanoparticles and switchable lanthanide luminescence, to protein detection was explored. Moreover, the potential of recombinant antibodies and aptamers as alternative affinity binders were evaluated. Additionally, alternative conjugation chemistries for production of the labeled binders were studied. Different assay concepts were also evaluated with respect to their applicability to point-of-care testing, which requires simple yet sensitive methods. The applicability of upconverting nanoparticles to the simultaneous quantitative measurement of multiple analytes using imaging-based detection was demonstrated. Additionally, the required instrumentation was relatively simple and inexpensive compared to other luminescent lanthanide-based labels requiring time-resolved measurement. The developed homogeneous assays exploiting switchable lanthanide luminescence were rapid and simple to perform and thus applicable even to point-ofcare testing. The sensitivities of the homogeneous assays were in the picomolar range, which are still inadequate for some analytes, such as cardiac troponins, requiring ultralow limits of detection. For most analytes, however, the obtained limits of detection were sufficient. The use of recombinant antibody fragments and aptamers as binders allowed site-specific and controlled covalent conjugation to construct labeled binders reproducibly either by using chemical modification or recombinant technology. Luminescent lanthanide labels were shown to be widely applicable for protein detection in various assay setups and to contribute assay sensitivity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of the work presented in this study was to demonstrate the wide applicability of a single-label quenching resonance energy transfer (QRET) assay based on time-resolved lanthanide luminescence. QRET technology is proximity dependent method utilizing weak and unspecific interaction between soluble quencher molecule and lanthanide chelate. The interaction between quencher and chelate is lost when the ligand binds to its target molecule. The properties of QRET technology are especially useful in high throughput screening (HTS) assays. At the beginning of this study, only end-point type QRET technology was available. To enable efficient study of enzymatic reactions, the QRET technology was further developed to enable measurement of reaction kinetics. This was performed using proteindeoxyribonuclei acid (DNA) interaction as a first tool to monitor reaction kinetics. Later, the QRET was used to study nucleotide exchange reaction kinetics and mutation induced effects to the small GTPase activity. Small GTPases act as a molecular switch shifting between active GTP bound and inactive GDP bound conformation. The possibility of monitoring reaction kinetics using the QRET technology was evaluated using two homogeneous assays: a direct growth factor detection assay and a nucleotide exchange monitoring assay with small GTPases. To complete the list, a heterogeneous assay for monitoring GTP hydrolysis using small GTPases, was developed. All these small GTPase assays could be performed using nanomolar protein concentrations without GTPase pretreatment. The results from these studies demonstrated that QRET technology can be used to monitor reaction kinetics and further enable the possibility to use the same method for screening.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Point-of-care (POC) –diagnostics is a field with rapidly growing market share. As these applications become more widely used, there is an increasing pressure to improve their performance to match the one of a central laboratory tests. Lanthanide luminescence has been widely utilized in diagnostics because of the numerous advantages gained by the utilization of time-resolved or anti-Stokes detection. So far the use of lanthanide labels in POC has been scarce due to limitations set by the instrumentation required for their detection and the shortcomings, e.g. low brightness, of these labels. Along with the advances in the research of lanthanide luminescence, and in the field of semiconductors, these materials are becoming a feasible alternative for the signal generation also in the future POC assays. The aim of this thesis was to explore ways of utilizing time-resolved detection or anti-Stokes detection in POC applications. The long-lived fluorescence for the time-resolved measurement can be produced with lanthanide chelates. The ultraviolet (UV) excitation required by these chelates is cumbersome to produce with POC compatible fluorescence readers. In this thesis the use of a novel light-harvesting ligand was studied. This molecule can be used to excite Eu(III)-ions at wavelengths extending up to visible part of the spectrum. An enhancement solution based on this ligand showed a good performance in a proof-of-concept -bioaffinity assay and produced a bright signal upon 365 nm excitation thanks to the high molar absorptivity of the chelate. These features are crucial when developing miniaturized readers for the time-resolved detection of fluorescence. Upconverting phosphors (UCPs) were studied as an internal light source in glucose-sensing dry chemistry test strips and ways of utilizing their various emission wavelengths and near-infrared excitation were explored. The use of nanosized NaYF :Yb3+,Tm3+-particles enabled the replacement of an external UV-light source with a NIR-laser and gave an additional degree of freedom in the optical setup of the detector instrument. The new method enabled a blood glucose measurement with results comparable to a current standard method of measuring reflectance. Microsized visible emitting UCPs were used in a similar manner, but with a broad absorbing indicator compound filtering the excitation and emission wavelengths of the UCP. This approach resulted in a novel way of benefitting from the non-linear relationship between the excitation power and emission intensity of the UCPs, and enabled the amplification of the signal response from the indicator dye.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Kvantitatiivinen reaaliaikainen polymeraasiketjureaktio (engl. polymerase chain reaction, PCR) on osoittautunut käyttäjäystävällisimmäksi menetelmäksi nukleiinihapposekvenssien kvantitoimisessa. Tätä menetelmää voidaan herkistää pienempien DNA-pitoisuuksien havaitsemiseen käyttämällä hyväksi aikaerotteista fluorometriaa (engl. time-resolved fluorometry, TRF) ja luminoivia lantanidileimoja, joiden fluoresenssin pitkän eliniän ansiosta emission mittaus voidaan suorittaa vasta hetki virittävän valopulssin jälkeen, jolloin lyhytikäinen taustasäteily ehtii sammua. Tuloksena saadaan korkea signaali-taustasuhde. Tämän diplomityön tarkoituksena oli rakentaa TRF:än pystyvä reaaliaikainen PCR-laite, sillä tällaista laitetta ei ole markkinoilla tarjolla. Laite rakennettiin kehittämällä lämpökierrätin ja yhdistämällä se valmiiseen TRF:än kykenevään mittapäähän. Mittapään ja lämpökierrättimen hallitsemiseksi kehitettiin myös tietokoneohjelma. Valon tuottamiseksi ja mittaamiseksi haluttiin käyttää edullisia komponentteja, joten työssä käytettiin valmiin mittapään optiikkaa, jossa viritys tapahtuu hohtodiodilla (engl. light-emitting diode, LED) ja lantanidileiman emission mittaus fotodiodilla (engl. photodiode, PD) tai valomonistinputkella (engl. photomultiplier tube, PMT). Myös mittapään suorituskykyä tutkittiin. Työtä varten kehitettiin lämpökierrätin, joka koostui Peltier-elementillä lämmitettävästä PCR-putkitelineestä ja lämpökannesta. Mittalaitteen suorituskyvyn tutkimiseen käytettiin kelaattikomplementaatioon perustuvaa PCR-tuotteen havaitsemismenetelmää. Kelaattikomplementaatio perustuu kahteen erilliseen oligonukleotidimolekyyliin, joista toiseen on sidottu lantanidi-ioni ja toiseen valoa absorboiva ligandirakenne, jotka yhdessä muodostavat fluoresoivan kokonaisuuden. Kehitetyn lämpökierrättimen todettiin olevan tarpeeksi tarkka sekä tehokas ja sen lämmitys- ja jäähdytysnopeuden maksimeiksi saatiin 2,6 °C/sekunti. Detektorina käytetyn PD:n ei todettu olevan tarpeeksi herkkä emission havainnoimiseksi ja se korvattiin laitteessa PMT:llä. Käytetyllä PCR-määrityksellä kynnyssykleiksi (engl. threshold cycle, Ct) sekä kehitetylle että referenssilaitteelle saatiin 28,4 käyttämällä samaa 100 000 kopion DNA:n aloitusmäärää. Työssä osoitettiin, että on mahdollista kehittää edullisia komponentteja käyttävä, TRF:än pystyvä, reaaliaikainen PCR-laite, joka kykenee vastaavaan Ct-arvoon kuin vertailulaite. PD:n herkkyys ei kuitenkaan riittänyt. Tulokset olivat lupaavia, sillä LED- ja PD-teknologiat kehittyvät ja markkinoille on tullut myös muita komponentteja, joiden avulla on tulevaisuudessa mahdollista kehittää vielä herkempi laite.