30 resultados para Steam-boilers, Water-tube

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation: S drive = H steam (ρ down + ρ mix) g where: ρ down - density of water in downcomer tubes; ρ mix - density of water in riser tubes; H steam - height of steam content section; g - acceleration of gravity. In steam boilers with natural circulation the circulation rate is usually between 10 and 30. Thus, consumption of water in the circulation circuit “circulation rate times” more than steam output of the boiler. There are two aspects of the design of natural water circulation loops. One is to ensure a sufficient mass flux of circulating water to avoid burnout of evaporator tubes. The other is to avoid tube wall temperature fluctuation and tube vibration due to oscillation of circulation velocity. The design criteria are therefore reduced, in principle, to those of critical heat flux, critical flow rate for burnout, and flow instability. In practical design, however, the circulation velocity and the void fraction at the evaporator tube outlet are used as the design criteria (Seikan I., et. al., 1999). This study has been made with assumption that the heat flux in the furnace of the boiler even all the time. The target of the study was to define the circulation rate of the boiler, thus average heat flux do not change it. I would like to acknowledge professionals from “Foster Wheeler” company for good and comfortable cooperation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tässä työssä perehdytään soodakattiloiden vesikiertomallin rakentamiseen. Työn päätavoitteena on kehittää simulointimallia varten taulukkolaskentapohja, jonka avulla soodakattilan lämpövuotietoja on yksinkertaista ja nopeaa käsitellä ja siirtää Apros 6 -simulointiohjelmaan. Lisäksi tarkoituksena on pyrkiä automatisoimaan työvaiheet mahdollisimman pitkälle, jolloin vesikiertolaskennan tekeminen yksinkertaistuisi, yhtenäistyisi ja tarkentuisi. Tämä on mahdollista Excel- makrojen ja Apros 6:n uusien toimintojen avulla. Apros 6:ssa on nyt mahdollista hyödyntää SCL- komentotiedostoja, joiden avulla sujuva tiedonsiirto Aproksen ja Excelin välillä vodaan toteuttaa. Vesikiertolaskentaan käytettävän datan käsittely on aikaisemmin ollut työlästä ja sen tarkkuus on pitkälti riippunut mallintajasta. Tässä diplomityössä päästään hyödyntämään uusimpia ja realistisempia soodakattiloiden CFD- malleja, joiden avulla pystytään luomaan aikaisempaa tarkemmat lämpövuojakaumat soodakattilan lämpöpinnoille. Tämä muutos parantaa vesikiertolaskennan tarkkuutta. Työn kokeellisessa osassa uutta Excel laskentatyökalua ja uusia lämpövuoarvoja testataan käytännössä. Eräs vanha Apros- vesikiertomalli päivitetään uusilla lämpövuoarvoilla ja sen rakenteeseen tehdään muutoksia tarkkuuden parantamiseksi. Uuden mallin toimivuutta testataan myös 115 %:n kapasiteetilla ja tutkitaan kuinka kyseinen vesikiertopiiri reagoi suurempaan lämpötehoon. Näitä kolmea eri tilannetta vertaillaan toisiinsa ja tarkastellaan eroavaisuuksia niiden vesi-höyrypiireissä.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, equations for the calculation of erosion wear caused by ash particles on convective heat exchanger tubes of steam boilers are presented. Anew, three-dimensional test arrangement was used in the testing of the erosion wear of convective heat exchanger tubes of steam boilers. When using the sleeve-method, three different tube materials and three tube constructions could be tested. New results were obtained from the analyses. The main mechanisms of erosionwear phenomena and erosion wear as a function of collision conditions and material properties have been studied. Properties of fossil fuels have also been presented. When burning solid fuels, such as pulverized coal and peat in steam boilers, most of the ash is entrained by the flue gas in the furnace. In bubbling andcirculating fluidized bed boilers, particle concentration in the flue gas is high because of bed material entrained in the flue gas. Hard particles, such as sharp edged quartz crystals, cause erosion wear when colliding on convective heat exchanger tubes and on the rear wall of the steam boiler. The most important ways to reduce erosion wear in steam boilers is to keep the velocity of the flue gas moderate and prevent channelling of the ash flow in a certain part of the cross section of the flue gas channel, especially near the back wall. One can do this by constructing the boiler with the following components. Screen plates can beused to make the velocity and ash flow distributions more even at the cross-section of the channel. Shield plates and plate type constructions in superheaters can also be used. Erosion testing was conducted with three types of tube constructions: a one tube row, an inline tube bank with six tube rows, and a staggered tube bank with six tube rows. Three flow velocities and two particle concentrations were used in the tests, which were carried out at room temperature. Three particle materials were used: quartz, coal ash and peat ash particles. Mass loss, diameter loss and wall thickness loss measurements of the test sleeves were taken. Erosion wear as a function of flow conditions, tube material and tube construction was analyzed by single-variable linear regression analysis. In developing the erosion wear calculation equations, multi-variable linear regression analysis was used. In the staggered tube bank, erosion wear had a maximum value in a tube row 2 and a local maximum in row 5. In rows 3, 4 and 6, the erosion rate was low. On the other hand, in the in-line tube bank the minimum erosion rate occurred in tube row 2 and in further rows the erosion had an increasing value, so that in a six row tube bank, the maximum value occurred in row 6.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modulaarisella vesiputkikattilalla tarkoitetaan täysin konepajalla valmistettavissa olevaa kattilaa, joka voidaan kuljettaa yhtenä tai muutamana suurena moduulina työmaalle. Tässä diplomityössä käsiteltiin modulaarisen vesiputkikattilan laskentasovelluksen ke-hittämistä KPA Unicon Oy:lle. Työn tavoitteena oli tarkastella modulaarisen vesiputkikattilan lämpöteknistä mitoitusta ja suunnittelua sekä kehittää laskentasovellus, jonka avulla voidaan arvioida kattilan mittoja ja painoa. Laskentasovellus laadittiin Microsoftin Excel-alustalle, josta se on myöhemmin mahdollista siirtää muille ohjelma-alustoille. Laskentasovelluksessa hyödynnetään lämmönsiirron ja virtaustekniikan laskentayhtälöitä sekä -menetelmiä. Sovellukseen valitut laskentayhtälöt sekä -menetelmät ovat yleisesti hyväksyttyjä ja käytännössä testattuja. Diplomityön tuloksena valmistui laskentasovellus, joka kykenee modulaarisen vesiputkikattilan lämpötekniseen mitoittamiseen. Sovelluksen avulla voidaan mitoittaa kattilan tulipesä, tulistimet, höyrystinpinnat sekä ekonomaiseri. Laskentasovellusta on tarkoitus hyödyntää yrityksen tarjousvaiheen projekteissa sekä mahdollisesti kattiloiden esisuunnittelussa. Laskentasovelluksen laatimista varten ei ollut mahdollista hyödyntää toiminnassa olevien kattiloiden prosessitietoja, koska ensimmäiset tämän tyyppiset kattilat ovat asenteilla. Sen sijaan sovelluksen antamia laskentatuloksia verrattiin toisen mitoitusohjelman antamiin tuloksiin, joiden perusteella laskentasovelluksen voidaan olettaa antavan oikeita tuloksia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alfa Laval Aalborg Oy designs and manufactures waste heat recovery systems utilizing extended surfaces. The waste heat recovery boiler considered in this thesis is a water-tube boiler where exhaust gas is used as the convective heat transfer medium and water or steam flowing inside the tubes is subject to cross-flow. This thesis aims to contribute to the design of waste heat recovery boiler unit by developing a numerical model of the H-type finned tube bundle currently used by Alfa Laval Aalborg Oy to evaluate the gas-side heat transfer performance. The main objective is to identify weaknesses and potential areas of development in the current H-type finned tube design. In addition, numerical simulations for a total of 15 cases with varying geometric parameters are conducted to investigate the heat transfer and pressure drop performance dependent on H-type fin geometry. The investigated geometric parameters include fin width and height, fin spacing, and fin thickness. Comparison between single and double tube type configuration is also conducted. Based on the simulation results, the local heat transfer and flow behaviour of the H-type finned tube is presented including boundary layer development between the fins, the formation of recirculation zone behind the tubes, and the local variations of flow velocity and temperature within the tube bundle and on the fin surface. Moreover, an evaluation of the effects of various fin parameters on heat transfer and pressure drop performance of H-type finned tube bundle has been provided. It was concluded that from the studied parameters fin spacing and fin width had the most significant effect on tube bundle performance and the effect of fin thickness was the least important. Furthermore, the results suggested that the heat transfer performance would increase due to enhanced turbulence if the current double tube configuration is replaced with single tube configuration, but further investigation and experimental measurements are required in order to validate the results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Compared to the use of traditional fossil fuels (coal, oil, natural gas), combustion of biomass and waste fuels has several environmental and economic advantages for heat and power generation. However, biomass and waste fuels might contain halogens (Cl, Br, F), alkali metals (Na, K) and heavy metals (Zn, Pb), which may cause harmful emissions and corrosion problems. Hightemperature corrosion occurs typically on furnace waterwalls and superheaters. The corrosion of the boiler tube materials limits the increase of thermal efficiency of steam boilers and leads to costly shutdowns and repairs. In recent years, some concerns have been raised about halogen (Cl, Br, and F)-related hightemperature corrosion in biomass- and waste-fired boilers. Chlorine-related high-temperature corrosion has been studied extensively. The presence of alkali chlorides in the deposits is believed to play a major role in the corrosion observed in biomass and waste fired boilers. However, there is much less information found in literature on the corrosion effect of bromine and fluorine. According to the literature, bromine is only assumed to play a role similar to chlorine; the role of fluorine is even less understood. In this work, a series of bubbling fluidized bed (BFB) bench-scale tests were carried out to characterize the formation and sulfation behaviors of KCl and KBr in BFB combustion conditions. Furthermore, a series of laboratory tests were carried out to investigate the hightemperature corrosion behaviors of three different superheater steels (10CrMo9-10, AISI 347 and Sanicro 28) exposed to potassium halides in ambient air and wet air (containing 30% H2O). The influence of H2O and O2 on the high-temperature corrosion of steels both with and without a salt (KCl) in three gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2) was also studied. From the bench-scale BFB combustion tests, it was found that HBr has a clearly higher affinity for the available K forming KBr than HCl forming KCl. The tests also indicated that KCl has a higher tendency for sulfation than KBr. From the laboratory corrosion tests in ambient air (also called “dry air” in Paper III and Paper IV), it was found that at relatively low temperatures (≤ 550 °C) the corrosivity of KBr and KF are similar to KCl. At 600 °C, KF showed much stronger corrosivity than KBr and KCl, especially for 10CrMo9-10 and AISI 347. When exposed to KBr or KF, 10CrMo9-10 was durable at least up to 450 °C, while AISI 347 and Sanicro 28 were durable at least up to 550 °C. From the laboratory corrosion tests in wet air (30% H2O), no obvious effect of water vapor was detected at 450 °C. At 550 °C, the influence of water vapor became significant in some cases, but the trend was not consistent. At 550 °C, after exposure with KBr, 10CrMo9-10 suffered from extreme corrosion; after exposure with KF and KCl, the corrosion was less severe, but still high. At 550 °C, local deep pitting corrosion occurred on AISI 347 and Sanicro 28 after exposure with KF. Some formation of K2CrO4 was observed in the oxide layer. At 550 °C, AISI 347 and Sanicro 28 suffered from low corrosion (oxide layer thickness of < 10 μm) after exposure with KBr and KCl. No formation of K2CrO4 was observed. Internal oxidation occurred in the cases of AISI 347 with KBr and KCl. From the laboratory corrosion tests in three different gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2), it was found that in tests with no salt, no corrosion occurred on AISI 347 and Sanicro 28 up to 600 °C in both the “O2-rich” (2% H2O-30% O2-N2) and “H2O-rich” (30% H2O-2% O2-N2) gas atmospheres; only 10CrMo9-10 showed increased corrosion with increasing temperature. For 10CrMo9-10 in the “O2-rich” atmosphere, the presence of KCl significantly increased the corrosion compared to the “no salt” cases. For 10CrMo9-10 in the “H2O-rich” atmosphere, the presence or absence of KCl did not show any big influence on corrosion. The formation of K2CrO4 was observed only in the case with the “O2-rich” atmosphere. Considering both the results from the BFB tests and the laboratory corrosion tests, if fuels containing Br were to be combusted, the corrosion damage of superheaters would be expected to be higher than if the fuels contain only Cl. Information generated from these studies can be used to help the boiler manufacturers in selecting materials for the most demanding combustion systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työssä selvitetään kiertolaskennan periaatteita kuplapetikattilassa, esitetään lyhyesti kattilan toimintaperiaate ja paneudutaan alan laskentaohjelmistoihin. Luonnonkierto kattilan vesihöyrypiirissä on seurausta hydrostaattisesta paineesta, joka aiheutuu tiheyserosta nousu- ja laskuputkien välillä. Kiertolaskennassa on huomioitava kaksifaasivirtauksen ominaispiirteet. Höyry ja neste virtaavat putkistossa eri nopeuksilla, jolloin esimerkiksi painehäviön määrityksessä käytetään erilaisia korrelaatioita ja käyrästöjä. Kaksifaasivirtauksen laskennassa tarvitaan kolmea eri taseyhtälöä: energiatasetta, massatasetta ja liikemäärätasetta. Luonnonkiertokattiloissa höyrykierron suunnittelussa on kaksi pääasiallista ehtoa. Ensimmäiseksi tulee varmistaa riittävä kiertoveden massavirta, jotta vältetään höyrystinputkien puhki palaminen. Toiseksi tulee välttää höyrystinputken pinnan lämpötilavaihteluita ja värähtelyitä. Alustavassa luonnonkierron mitoituksessa turvaudutaan kokemusperäiseen tietoon. Myöhemmässä tarkemmassa mitoituksessa käytettäviä ohjelmistoja ovat NOWA sekä kaupalliset PPSD ja Apros. Laskenta lähtee liikkeelle siitä, että lasketaan ensin vesihöyrykierron massavirrat erilaisilla lämpökuormilla ja höyryntuotanto määritellään painehäviöiden perusteella. NOWA- ja PPSD- ohjelmistoilla tehtyjen esimerkkilaskelmien perusteella voidaan sanoa, että tulokset riippuvat käytetystä laskentamallista.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tässä työssäon tarkasteltu yleisesti höyrykattiloiden säilöntää. Erilaisten säilöntämenetelmien perustietojen lisäksi työssä on pyritty selvittämään eri kattilatyypeille ominaiset säilöntätavat. Märkäsäilönnän jälkeistä käyttöönottoa on pohdittu selvittämällä laskennallisesti, onko tarpeen vaihtaa kattilaan vahvasti kemikaloidun säilöntäliuoksen tilalle puhtaampaa syöttövettä. Esimerkkinä on käytetty Voikkaan paperitehtaan höyryvoimalaitoksen kattila K13:ta. Työtä tehdessä on käytetty apuna aihetta käsittelevää kirjallisuutta, jota on saatu höyrykattiloita säilöviltä voimalaitoksilta, kemikaalitoimittajilta sekä asiantuntijoiden tekemistä luentomonisteista. Lieriökattiloiden höyrypuoli säilötään lähes poikkeuksetta märkänä, sillä se on vaikea tyhjentää täysin kosteudesta. Läpivirtauskattilalaitoksella käytetään usein sekä kuiva- että märkäsäilöntää. Savukaasupuolen korroosio ehkäistään useinmiten pitämällä kattila niin lämpimänä, että kastepistealituksia ei tapahdu.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli selvittää tapoja hallita voimalaitoksen höyryjärjestelmän paineensäätöä. Työ on tehty Neste Oilin Porvoon jalostamon energialaitoksen höyryjärjestelmästä. Energialaitos käsittää kaksi höyrykattilaa ja kaasuturbiinivoimalaitoksen, sekä öljynjalostamolla sijaitsevat höyrykattilan ja kaasuturbiinivoimalaitoksen. Höyryverkon häiriötilanteet aiheuttavat paineenlaskua höyryverkossa, jos jonkun höyryntuottajan tuotanto keskeytyy, tai paineennousua höyryverkossa, jos joku höyrynkuluttajista ei kuluta enää höyryä. Nykyisessä tilanteessa vakavin paineen laskua aiheuttava häiriötilanne olisi energialaitoksen höyrykattilan tuotannon keskeytyminen. Vakavin paineennousua aiheuttava häiriötilanne olisi suurimman kuluttajan,eli energialaitoksen vastapaineturbiinin, irtaantuminen höyryverkosta. Paineen hallinta voidaan toteuttaa oikeanlaisilla automaation ratkaisuilla, joita on mahdollista kehittää käyttökokemukseen perustuen järjestelmäpäivitysten yhteydessä. Häiriötilanteita voidaan yrittää ennakoida kunnossapidon keinoin niin, että vikaantuminen havaitaan ennen kuin vakava häiriö tapahtuu. Erityisesti kunnossapitostrategian kehittäminen auttaisi kohdistamaan kunnossapitotoimenpiteet oleellisimpiin kohteisiin kustannustehokkaasti. Lisäksi käyttöhenkilökunnan oikeanlaisella toiminnalla häiriön sattuessa voidaan häiriöiden aiheuttamia seuraamuksia tuotantoon ja turvallisuuteen lieventää. Käyttöhenkilökunnan toimintaa voidaan parantaa koulutuksella.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli tutkia höyrykattiloiden leijukerrosten käytettävyysongelmia ja kirjallisuudesta löytyvien diagnostiikkamenetelmien toimivuutta leijukerroksen tilan ja käytettävyysongelmien tunnistamiseksi. Diagnostiikkamenetelmien toimivuutta testattiin VTT:n kiertoleijukoelaitteen prosessimittauksiin perustuen. Analysoinnissa käytettiin prosessimittauksia, jotka ovat yleisesti käytössä energiantuotannon leijukerroskattiloissa. Analysoitavina koeajotapauksina olivat kylmäkokeet partikkelikokojakaumaltaan vaihtelevalle leijutusmateriaalille, tuhkapartikkelien aiheuttama petimateriaalin karkeneminen ja agglomeroituminen, sekä vaihtelevien ajoarvojen vaikutus leijukerroksen hydrodynaamiseen käyttäytymiseen. Kokeellisesta osiosta saaduista tuloksista selvisi leijutusilman tilavuusvirran, petimassan ja partikkelikoon vaikutus analysoitavaan prosessimittaukseen. Tuloksista oli havaittavissa myös kiertävän petimateriaalin ja pohjapedin osuuksien vaikutus mitattuun painesignaaliin. Petipartikkelien agglomeroitumisen ja karkenemisen todettiin lisäävän kiertoleijukoelaitteistossa nousuputken pohjapedin määrää suhteessa kiertävään petimateriaaliin, mikä voitiin havaita painemittauksista.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työssä kehitetään standardin EN 12952 mukaisille vesiputkikattiloiden paineenalaisille osille lujuuslaskentaohjelma. Lisäksi perehdytään putkisto-osien mitoituksen lujuusopilliseen pohjaan ja tarkastellaan vastaako standardin mitoitus sitä. Standardin EN 13480 mukaisille metallisille teollisuusputkistoille on kohdeyrityksellä käytössään mitoitusohjelma. Näin ollen työssä vertaillaan standardin EN 12952 ja EN 13480 mukaisia putkisto-osien mitoituksia. Vertailun perusteella selvitetään mitkä putkistokomponentit voidaan mitoittaa olemassa olevalla ohjelmalla. Joidenkin putkisto-osien mitoitus on standardeissa yhtenevä. Suunnittelujännitys määritetään kuitenkin eri tavalla kyseisissä standardeissa. Tämän takia kaikki yrityksen tarvitsemat putkistokomponentit ovat kirjattu kehitettyyn laskentaohjelmaan. Koska putkistokomponenttien mitoitus on yhtenevä monelta osin kyseisissä standardeissa, vertaillaan ohjelmien antamia tuloksia toisiinsa. Näin voidaan todeta kehitetty laskentaohjelma toimivaksi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Kemira Chemicals Oy:n Joutsenon kloori-alkalitehtaalla valmistetaan elektrolyysin avulla lipeää, suolahappoa, natriumhypokloriittia ja vetyä. Tämän työn tavoitteena on kartoittaa kloori-alkalitehtaan tuotantokapasiteetin kasvatuksen yhteydessä esiin tulevat pullonkaulat, lähitulevaisuuden kunnossapitotarpeet sekä parhaat käytettävissä olevat teknologiavaihtoehdot kloori-alkalitehtaan osa-alueille, joihin tuotantokapasiteetin kasvatuspaineet kohdistuvat: elektrolyysi, lipeän haihdutus ja suolahappopolttimet. Pullonkaulojen kartoittaminen toteutettiin rakentamalla taulukkolaskentamalli kloori-alkalitehtaan prosesseista. Mallin avulla simuloitiin elektrolyysin kloorin tuotantoa, jota kasvatettiin asteittain 54 kt:sta/a aina 100 kt:iin/a asti ja tutkittiin prosessien käyttäytymistä. Tarkastelun pohjalta havaittiin, että kloorin tuotantoa kasvattaessa, tulee lisätä myös tuotantokapasiteettia suolahapon valmistukseen, elektrolyysiin, demineralisoidun veden valmistukseen ja lipeän haihdutuslaitokseen sekä suolahapon ja lipeän varastointikapasiteetteihin. Vaihtoehtoiset teknologiat määritettiin kirjallisuudesta ja laitetoimittajien esitteistä. Lähivuosien kunnossapitotarpeet kartoitettiin haastattelemalla tehtaan henkilökuntaa. Työstä eskaloitui useita jatkotutkimuskohteita, joita ovat bipolaari-teknologian soveltuvuus Joutsenon kloori-alkalitehtaalle, uusien HCl-polttimien esisuunnittelu, höyryn käytön tehostaminen nykyisessä lipeän haihdutuslaitoksessa sekä uusien haihdutusteknologioiden soveltuvuus Joutsenon kloori-alkalitehtaalle, höyry- ja jäähdytysverkostojen kartoitukset sekä demineralisoidun veden valmistuskapasiteetin kasvattaminen.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Många förbränningsanläggningar som bränner utmanande bränslen såsom restfraktioner och avfall råkar ut för problem med ökad korrosion på överhettare och/eller vattenväggar pga. komponenter i bränslena som är korrosiva. För att minimera problemen i avfallseldade pannor hålls ångparametrarna på en relativt låg nivå, vilket drastiskt minskar energiproduktionen. Beläggningarna i avfallseldade pannor består till största delen av element som är förknippade med högtemperaturkorrosion: Cl, S, alkalimetaller, främst K och Na, och tungmetaller som Pb och Zn, och det finns också indikationer av Br-förekomst. Det låga ångtrycket i avfallseldade pannor påverkar också stålrörens temperatur i pannväggarna i eldstaden. I dagens läge hålls temperaturen normalt vid 300-400 °C. Alkalikloridorsakad (KCl, NaCl) högtemperaturkorrosion har inte rapporterats vara relevant vid såpass låga temperaturer, men närvaro av Zn- och Pb-komponenter i beläggningarna har påvisats förorsaka ökad korrosion redan vid 300-400 °C. Vid förbränning kan Zn och Pb reagera med S och Cl och bilda klorider och sulfater i rökgaserna. Dessa tungmetallföreningar är speciellt problematiska pga. de bildar lågsmältande saltblandningar. Dessa lågsmältande gasformiga eller fasta föreningar följer rökgasen och kan sedan fastna eller kondensera på kallare ytor på pannväggar eller överhettare för att sedan bilda aggressiva beläggningar. Tungmetallrika (Pb, Zn) klorider och sulfater ökar risken för korrosion, och effekten förstärks ytterligare vid närvaro av smälta. Motivet med den här studien var att få en bättre insikt i högtemperaturkorrosion förorsakad av Zn och Pb, samt att undersöka och prediktera beteendet och motståndskraften hos några stålkvaliteter som används i överhettare och pannväggar i tungmetallrika förhållanden och höga materialtemperaturer. Omfattande laboratorie-, småskale- och fullskaletest utfördes. Resultaten kan direkt utnyttjas i praktiska applikationer, t.ex. vid materialval, eller vid utveckling av korrosionsmotverkande verktyg för att hitta initierande faktorer och förstå deras effekt på högtemperaturkorrosion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Inhibition of global warming has become one of the major goals for the coming decades. A key strategy is to replace fossil fuels with more sustainable fuels, which has generated growing interest in the use of waste-derived fuels and of biomass fuels. However, from the chemical point of view, biomass is an inhomogeneous fuel, usually with a high concentration of water and considerable amounts of potassium and chlorine, all of which are known to affect the durability of superheater tubes. To slow down or reduce corrosion, power plants using biomass as fuel have been forced to operate at lower steam temperatures as compared to fossil fuel power plants. This reduces power production efficiency: every 10°C rise in the steam temperature results in an approximate increase of 2% in power production efficiency. More efficient ways to prevent corrosion are needed so that power plants using biomass and waste-derived fuels can operate at higher steam temperatures. The aim of this work was to shed more light on the alkali-induced corrosion of superheater steels at elevated temperatures, focusing on potassium chloride, the alkali salt most frequently encountered in biomass combustion, and on potassium carbonate, another potassium salt occasionally found in fly ash. The mechanisms of the reactions between various corrosive compounds and steels were investigated. Based on the results, the potassium-induced accelerated oxidation of chromia protected steels appears to occur in two consecutive stages. In the first, the protective chromium oxide layer is destroyed through a reaction with potassium leading to the formation of intermediates such as potassium chromate (K2CrO4) and depleting the chromium in the protective oxide layer. As the chromium is depleted, chromium from the bulk steel diffuses into the oxide layer to replenish it. In this stage, the ability of the material to withstand corrosion depends on the chromium content (which affects how long it takes the chromium in the oxide layer to be depleted) and on external factors such as temperature (which affects how fast the chromium diffuses into the protective oxide from the bulk steel). For accelerated oxidation to continue, the presence of chloride appears to be essential.