8 resultados para Static biopile
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
In distributed energy production, permanent magnet synchronous generators (PMSG) are often connected to the grid via frequency converters, such as voltage source line converters. The price of the converter may constitute a large part of the costs of a generating set. Some of the permanent magnet synchronous generators with converters and traditional separately excited synchronous generators couldbe replaced by direct-on-line (DOL) non-controlled PMSGs. Small directly networkconnected generators are likely to have large markets in the area of distributed electric energy generation. Typical prime movers could be windmills, watermills and internal combustion engines. DOL PMSGs could also be applied in island networks, such as ships and oil platforms. Also various back-up power generating systems could be carried out with DOL PMSGs. The benefits would be a lower priceof the generating set and the robustness and easy use of the system. The performance of DOL PMSGs is analyzed. The electricity distribution companies have regulations that constrain the design of the generators being connected to the grid. The general guidelines and recommendations are applied in the analysis. By analyzing the results produced by the simulation model for the permanent magnet machine, the guidelines for efficient damper winding parameters for DOL PMSGs are presented. The simulation model is used to simulate grid connections and load transients. The damper winding parameters are calculated by the finite element method (FEM) and determined from experimental measurements. Three-dimensional finite element analysis (3D FEA) is carried out. The results from the simulation model and 3D FEA are compared with practical measurements from two prototype axial flux permanent magnet generators provided with damper windings. The dimensioning of the damper winding parameters is case specific. The damper winding should be dimensioned based on the moment of inertia of the generating set. It is shown that the damper winding has optimal values to reach synchronous operation in the shortest period of time after transient operation. With optimal dimensioning, interferenceon the grid is minimized.
Resumo:
The aim of this study was to describe the demographic, clinicopathological, biological and morphometric features of Libyan breast cancer patients. The supporting value of nuclear morphometry and static image cytometry in the sensitivity for detecting breast cancer in conventional fine-needle aspiration biopsies were estimated. The findings were compared with findings in breast cancer in Finland and Nigeria. In addation, the value of ER and PR were evaluated. There were 131 histological samples, 41 cytological samples, and demographic and clinicopathological data from 234 Libyan patients. The Libyan breast cancer is dominantly premenopausal and in this feature it is similar to breast cancer in sub-Saharan Africans, but clearly different from breast cancer in Europeans, whose cancers are dominantly postmenopausal in character. At presention most Libyan patients have locally advanced disease, which is associated with poor survival rates. Nuclear morphometry and image DNA cytometry agree with earlier published data in the Finnish population and indicate that nuclear size and DNA analysis of nuclear content can be used to increase the cytological sensitivity and specificity in doubtful breast lesions, particularly when free cell sampling method is used. Combination of the morphometric data with earlier free cell data gave the following diagnostic guidelines: Range of overlap in free cell samples: 55 μm2 -71 μm2. Cut-off values for diagnostic purposes: Mean nuclear area (MNA) >54 μm2 for 100% detection of malignant cases (specificity 84 %), MNA < 72 μm2 for 100% detection of benign cases (sensitivity 91%). Histomorphometry showed a significant correlation between the MNA and most clinicopathological features, with the strongest association observed for histological grade (p <0.0001). MNA seems to be a prognosticator in Libyan breast cancer (Pearson’s test r = - 0.29, p = 0.019), but at lower level of significance than in the European material. A corresponding relationship was not found in shape-related morphometric features. ER and PR staining scores were in correlation with the clinical stage (p= 0.017, and 0.015, respectively), and also associated with lymph node negative patients (p=0.03, p=0.05, respectively). Receptor-positive (HR+) patients had a better survival. The fraction of HR+ cases among Libyan breast cancers is about the same as the fraction of positive cases in European breast cancer. The study suggests that also weak staining (corresponding to as few as 1% positive cells) has prognostic value. The prognostic significance may be associated with the practice to use antihormonal therapy in HR+ cases. The low survival and advanced presentation is associated with active cell proliferation, atypical nuclear morphology and aneuploid nuclear DNA content in Libyan breast cancer patients. The findings support the idea that breast cancer is not one type of disease, but should probably be classified into premenopausal and post menopausal types.
Resumo:
The purpose of this study was to investigate the suitability of the Finnish Defence Forces’ NH90 helicopter for parachuting operations with the T-10 static line parachute system. The work was based on the Army Command’s need to compensate for the reduction in the outsourced flight hours for the military static line parachuting training. The aim of the research was to find out the procedures and limitations with which the NH90 IOC+ or FOC version helicopter could be used for static line parachutist training with the T-10B/MC1-1C parachutes. The research area was highly complicated and non-linear. Thus analytical methods could not be applied with sufficient confidence, even with present-day computing power. Therefore an empirical research method was selected, concentrating on flight testing supported with literature study and some calculated estimations. During three flights and 4.5 flight hours in Utti, Finland on 1720 September 2012, a total of 44 parachute drops were made. These consisted of 16 dummy drops and 28 paratrooper jumps. The test results showed that when equipped with the floor mounted PASI-1 anchor line, the deflector bar of the NHIndustries’ Parachuting Kit and Patria’s floor protection panels the Finnish NH90 variant could be safely used for T-10B/MC1-1C static line parachuting operations from the right cabin door at airspeed range of 5080 KIAS (90–150 km/h). The ceiling mounted anchor lines of the NHI’s Parachuting Kit were not usable with the T-10 system. This was due to the static lines’ unsafe behaviour in slipstream when connected to the cabin ceiling level. In conclusion, the NH90 helicopter can be used to meet the Army Command’s requirement for an additional platform for T-10 static line parachutist training. Material dropping, the effect of additional equipment and jumping from the rear ramp should be further studied.
Resumo:
The purpose of this study was to investigate the suitability of the Finnish Defence Forces’ NH90 helicopter for parachuting operations with the T-10 static line parachute system. The work was based on the Army Command’s need to compensate for the reduction in the outsourced flight hours for the military static line parachuting training. The aim of the research was to find out the procedures and limitations with which the NH90 IOC+ or FOC version helicopter could be used for static line parachutist training with the T- 10B/MC1-1C parachutes. The research area was highly complicated and non-linear. Thus analytical methods could not be applied with sufficient confidence, even with present-day computing power. Therefore an empirical research method was selected, concentrating on flight testing supported with literature study and some calculated estimations. During three flights and 4.5 flight hours in Utti, Finland on 17−20 September 2012, a total of 44 parachute drops were made. These consisted of 16 dummy drops and 28 paratrooper jumps. The test results showed that when equipped with the floor mounted PASI-1 anchor line, the deflector bar of the NHIndustries’ Parachuting Kit and Patria’s floor protection panels the Finnish NH90 variant could be safely used for T-10B/MC1-1C static line parachuting operations from the right cabin door at airspeed range of 50−80 KIAS (∼90–150 km/h). The ceiling mounted anchor lines of the NHI’s Parachuting Kit were not usable with the T-10 system. This was due to the static lines’ unsafe behaviour in slipstream when connected to the cabin ceiling level. In conclusion, the NH90 helicopter can be used to meet the Army Command’s requirement for an additional platform for T-10 static line parachutist training. Material dropping, the effect of additional equipment and jumping from the rear ramp should be further studied.
Resumo:
The aim of this work was to calibrate the material properties including strength and strain values for different material zones of ultra-high strength steel (UHSS) welded joints under monotonic static loading. The UHSS is heat sensitive and softens by heat due to welding, the affected zone is heat affected zone (HAZ). In this regard, cylindrical specimens were cut out from welded joints of Strenx® 960 MC and Strenx® Tube 960 MH, were examined by tensile test. The hardness values of specimens’ cross section were measured. Using correlations between hardness and strength, initial material properties were obtained. The same size specimen with different zones of material same as real specimen were created and defined in finite element method (FEM) software with commercial brand Abaqus 6.14-1. The loading and boundary conditions were defined considering tensile test values. Using initial material properties made of hardness-strength correlations (true stress-strain values) as Abaqus main input, FEM is utilized to simulate the tensile test process. By comparing FEM Abaqus results with measured results of tensile test, initial material properties will be revised and reused as software input to be fully calibrated in such a way that FEM results and tensile test results deviate minimum. Two type of different S960 were used including 960 MC plates, and structural hollow section 960 MH X-joint. The joint is welded by BöhlerTM X96 filler material. In welded joints, typically the following zones appear: Weld (WEL), Heat affected zone (HAZ) coarse grained (HCG) and fine grained (HFG), annealed zone, and base material (BaM). Results showed that: The HAZ zone is softened due to heat input while welding. For all the specimens, the softened zone’s strength is decreased and makes it a weakest zone where fracture happens while loading. Stress concentration of a notched specimen can represent the properties of notched zone. The load-displacement diagram from FEM modeling matches with the experiments by the calibrated material properties by compromising two correlations of hardness and strength.
Resumo:
Various researches in the field of econophysics has shown that fluid flow have analogous phenomena in financial market behavior, the typical parallelism being delivered between energy in fluids and information on markets. However, the geometry of the manifold on which market dynamics act out their dynamics (corporate space) is not yet known. In this thesis, utilizing a Seven year time series of prices of stocks used to compute S&P500 index on the New York Stock Exchange, we have created local chart to the corporate space with the goal of finding standing waves and other soliton like patterns in the behavior of stock price deviations from the S&P500 index. By first calculating the correlation matrix of normalized stock price deviations from the S&P500 index, we have performed a local singular value decomposition over a set of four different time windows as guides to the nature of patterns that may emerge. I turns out that in almost all cases, each singular vector is essentially determined by relatively small set of companies with big positive or negative weights on that singular vector. Over particular time windows, sometimes these weights are strongly correlated with at least one industrial sector and certain sectors are more prone to fast dynamics whereas others have longer standing waves.
Resumo:
Tämä insinöörityö tehtiin ABB Oy, Drivesin Product AC -tulosyksikön tuotekehitysosastolle Helsingissä. Työssä kehitettiin taajuusmuuttajien suorituskyvyn automaattinen testausympäristö. ABB:n taajuusmuuttajien suorituskykytestejä ei ole aikaisemmin automatisoitu. Testit on tehty käsin ja niiden suorittamiseen ja tulosten käsittelyyn on kulunut paljon aikaa. Automaattisella testauksella pyrittiin testien suorittamiseen ja tulosten käsittelyyn kuluvan ajan huomattavaan pienentymiseen. Työssä ei ollut tarkoituksena tehdä suorituskykytestejä vaan kehittää automaattinen testausympäristö eli suorituskykytestipenkki, jossa suorituskykytestit on mahdollista suorittaa. Työssä keskityttiin taajuusmuuttajan nopeus- ja momenttisäätäjien suorituskykyyn. Työ toteutettiin suunnittelu- ja ohjelmointityönä. Testausympäristön laitteisto perustuu ABB:n tuotekehityslaboratorioiden olemassaoleviin testipaikkoihin. Testausympäristössä käytetään taajuusmuuttajien lisäksi pääasiassa kolmivaiheisia oikosulkumoottoreita. Lisäksi laitteistoon kuuluu ACS800-sarjan taajuusmuuttaja kuormakäyttönä, momenttianturi ja takometri eli kierrosnopeusmittari. Ohjelmointi tehtiin National Instrumentsin LabVIEW-ohjelmointiympäristön versiolla 8.0. Testausympäristön käyttöliittymänä toimii saman yrityksen TestStand-testausohjelmiston versio 3.5. Testattavien taajuusmuuttajien ohjausta ja momenttianturin lukemista varten ohjelmoitiin virtuaali-instrumentteja. Virtuaali-instrumentteja kutsutaan TestStand-testisekvensseistä. Testisekvenssit luodaan TestStandin sekvenssieditorilla ja suoritetaan sekvenssieditorissa tai operaattorin käyttöliittymässä. Työn tuloksena syntyi taajuusmuuttajien suorituskyvyn automaattinen testausympäristö. Testausympäristöä voidaan hyödyntää sekä nykyisen että seuraavan sukupolven taajuusmuuttajien testauksessa. Sillä on mahdollista suorittaa yleisimmät taajuusmuuttajien suorituskykytestit, kuten nopeus- ja momenttisäätöjen staattinen ja dynaaminen tarkkuus, hyvin kattavasti. Testit voidaan automaattisesti suorittaa koko testikäytön sallimalla pyörimisnopeus- ja kuormitusalueella. Näytteenottotaajuus voi olla enintään 1 kHz luettaessa pyörimisnopeutta ACS800-sarjan taajuusmuuttajan kautta ja momenttianturia samanaikaisesti. Virtuaali-instrumenteista koostuvia testisekvenssejä voidaan vapaasti muokata ja kehittää testejä edelleen tai luoda kokonaan uusia testejä. Testausympäristö perustuu teollisuudessa yleisesti käytettyihin ohjelmistoihin ja tarjoaa hyvät mahdollisuudet jatkokehitykselle.