5 resultados para Stabilization plano
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
Weak acid cation exchange (WAC) resins are used in the chromatographic separation of betaine from vinasse, a by-product of sugar industry. The ionic form of the resin determines the elution time of betaine. When a WAC-resin is in hydrogen form, the retention time of betaine is the longest and betaine elutes as the last component of vi-nasse from the chromatographic column. If the feed solution contains salts and its pH is not acidic enough to keep the resin undissociated, the ionic form of the hydrogen form resin starts to alter. Vinasse contains salts and its pH is around 5, it also contains weak acids. To keep the metal ion content (Na/H ratio) of the resin low enough to ensure successful separation of betaine, acid has to be added to either eluent (water) or vinasse. The aim of the present work was to examine by laboratory experiments which option requires less acid. Also the retention mechanism of betaine was investigated by measuring retention volumes of acetic acid and choline in different Na/H ratios of the resin. It was found that the resulting ionic form of the resin is the same regardless of whether the regeneration acid is added to the eluent or the feed solution (vinasse). Be-sides the salt concentration and the pH of vinasse, also the concentration of weak acids in the feed affects the resulting ionic form of the resin. The more buffering capacity vinasse has, the more acid is required to keep the ionic form of the resin desired. Vinasse was found to be quite strong buffer solution, which means relatively high amounts of acid are required to prevent the Na/H ratio from increasing too much. It is known that the retention volume of betaine decreases significantly, when the Na/H ratio increases. This is assumed to occur, because the amount of hydrogen bonds between the carboxylic groups of betaine and the resin decreases. Same behavior was not found with acetic acid. Choline has the same molecular structure as betaine, but instead of carboxylic group it has hydroxide group. The retention volume of choline increased as the Na/H ratio of the resin increased, because of the ion exchange reaction between choline cation and dissociated carboxylic group of the resin. Since the retention behavior of choline on the resin is opposite to the behavior of be-taine, the strong affinity of betaine towards hydrogen form WAC-resin has to be based on its carboxylic group. It is probable that the quaternary ammonium groups also affect the behavior of the carboxylic groups of betaine, causing them to form hydrogen bonds with the carboxylic groups of the resin.
Resumo:
The aim of this thesis was to evaluate the short- and long-term effectiveness of a prefabricated occlusal appliance (R) on patients with myofascial pain and headache by comparing it with the treatment of the stabilization appliance (S). Another aim was to evaluate the effect of appliance treatment on stress-related salivary parameters like cortisol and IgA, as well as on flow rate values in these patients. Sixty-five patients diagnosed with myofascial temporomandibular disorder (TMD) pain, of whom 94% suffered concomitantly from headache, at two centres for Stomatognathic Physiology, one in Sweden and one in Finland, were included in this randomized controlled trial using Research Diagnostic Criteria for TMD (RDC/TMD), with history questionnaires and clinical examinations performed at baseline and at 6- and 10-weeks, and 6- and 12-month follow-ups. Patients were randomly assigned either to the R or the S group. Treatment outcome was measured according to IMMPACT (Initiative on Methods, Measurements, and Pain Assessment in Clinical Trials), i.e. four chronic pain outcome domains: pain intensity, overall improvement, physical and emotional functioning. Changes in frequency and intensity of headache were recorded. Thirty-nine patients participated in the saliva study. Salivary analyses were performed at 6 and 10 weeks. The results revealed no differences between groups at baseline. At all follow-ups, all four outcome measures, as well as frequency and intensity of headache, showed statistically significant within-group improvement compared to baseline, without significant differences between groups. No treatment-induced changes in saliva parameters could be registered. In conclusion, the effectiveness of the prefabricated appliance seemed to be similar to that of the stabilization appliance in alleviating myofascial pain, and frequency and intensity of headache, in the short as well as the long term. However, no changes in salivary parameters were observed during treatment.
Resumo:
Kartta kuuluu A. E. Nordenskiöldin kokoelmaan
Resumo:
Kartta kuuluu A. E. Nordenskiöldin kokoelmaan