42 resultados para Short rails
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
Summary
Resumo:
Summary
Resumo:
Summary
Resumo:
Selostus: Eräiden ympäristövirikkeiden saatavuuden estämisen välittömät vaikutukset tarhaminkin käyttäytymiseen
Resumo:
Abstract
Resumo:
The Thesis gives a decision support framework that has significant impact on the economic performance and viability of a hydropower company. The studyaddresses the short-term hydropower planning problem in the Nordic deregulated electricity market. The basics of the Nordic electricity market, trading mechanisms, hydropower system characteristics and production planning are presented in the Thesis. The related modelling theory and optimization methods are covered aswell. The Thesis provides a mixed integer linear programming model applied in asuccessive linearization method for optimal bidding and scheduling decisions inthe hydropower system operation within short-term horizon. A scenario based deterministic approach is exploited for modelling uncertainty in market price and inflow. The Thesis proposes a calibration framework to examine the physical accuracy and economic optimality of the decisions suggested by the model. A calibration example is provided with data from a real hydropower system using a commercial modelling application with the mixed integer linear programming solver CPLEX.
Resumo:
Tämä diplomityö tarkastelee TETRA-verkon soveltuvuutta turvallisuusviranomaisille tarkoitettuun telemetriasovellukseen, jossa erilaiset mittausdatat ja hälytystiedot kulkevat verkon yli SDS-viestiliikenteenä. Diplomityön tarkoituksena on tehdä kaksi sulautettua ohjelmistoa sekä yksi PCohjelmisto, joita käytetään rakennettavassa demolaitteistossa. Lisäksi selvitetään TETRA-verkon toimivuus ja rajoitukset sovelluksessa eri olosuhteissa ja eri kuormitustilanteissa. Diplomityön teoriaosassa käydään läpi työn määrittely ja ohjelmistonkehitysprosessin läpivienti eri osa-alueilla. Loppuosassa kuvataan tehdyt ohjelmistot erikseen ja yhdessä suunnittelusta toteutukseen, sekä lopullisen järjestelmän testaus.
Resumo:
Tämän tutkielman tavoitteena on tutkia tekijöitä jotkavaikuttavat lyhyellä ja pitkällä aikavälillä kullan hintaan. Toiseksi tutkielmassa selvitetään mitä eri sijoitusmahdollisuuksia löytyy kultaan sijoitettaessa. Aineistona käytetään kuukausitasoista dataa Yhdysvaltain ja maailman hintaindekseistä, Yhdysvaltain ja maailman inflaatiosta ja inflaation volatiliteetista, kullan beetasta, kullan lainahinnasta, luottoriskistä ja Yhdysvaltojen ja maailman valuuttakurssi indeksistä joulukuulta 1972 elokuulle 2006. Yhteisintegraatio regressiotekniikoita käytettiin muodostamaan malli jonka avullatutkittiin päätekijöitä jotka vaikuttavat kullan hintaan. Kirjallisuutta tutkimalla selvitettiin miten kultaan voidaan sijoittaa. Empiirisettulokset ovat yhteneväisiä edellisten tutkimusten kanssa. Tukea löytyi sille, että kulta on pitkän ajan suoja inflaatiota vastaan ja kulta ja Yhdysvaltojen inflaatio liikkuvat pitkällä aikavälillä yhdessä. Kullan hintaan vaikuttavat kuitenkin lyhyen ajan tekijät pitkän ajan tekijöitä enemmän. Kulta on myös sijoittajalle helppo sijoituskohde, koska se on hyvin saatavilla markkinoilla ja eri instrumentteja on lukuisia.
Resumo:
In the electrical industry the 50 Hz electric and magnetic fields are often higher than in the average working environment. The electric and magnetic fields can be studied by measuring or by calculatingthe fields in the environment. For example, the electric field under a 400 kV power line is 1 to 10 kV/m, and the magnetic flux density is 1 to 15 µT. Electricand magnetic fields of a power line induce a weak electric field and electric currents in the exposed body. The average current density in a human being standing under a 400 kV line is 1 to 2 mA/m2. The aim of this study is to find out thepossible effects of short term exposure to electric and magnetic fields of electricity power transmission on workers' health, in particular the cardiovascular effects. The study consists of two parts; Experiment I: influence on extrasystoles, and Experiment II: influence on heart rate. In Experiment I two groups, 26 voluntary men (Group 1) and 27 transmission-line workers (Group 2), were measured. Their electrocardiogram (ECG) was recorded with an ambulatory recorder both in and outside the field. In Group 1 the fields were 1.7 to 4.9 kV/m and 1.1 to 7.1 pT; in Group 2 they were 0.1 to 10.2 kV/m and 1.0 to 15.4 pT. In the ECG analysis the only significant observation was a decrease in the heart rate after field exposure (Group 1). The drop cannot be explained with the first measuring method. Therefore Experiment II was carried out. In Experiment II two groups were used; Group 1 (26 male volunteers) were measured in real field exposure, Group 2 (15 male volunteers) in "sham" fields. The subjects of Group 1 spent 1 h outside the field, then 1 h in the field under a 400 kV transmission line, and then again 1 h outside the field. Under the 400 kV linethe field strength varied from 3.5 to 4.3 kV/m, and from 1.4 to 6.6 pT. Group 2spent the entire test period (3 h) in a 33 kV outdoor testing station in a "sham" field. ECG, blood pressure, and electroencephalogram (EEG) were measured by ambulatory methods. Before and after the field exposure, the subjects performed some cardiovascular autonomic function tests. The analysis of the results (Experiments I and II) showed that extrasystoles or arrythmias were as frequent in the field (below 4 kV/m and 4 pT) as outside it. In Experiment II there was no decrease detected in the heart rate, and the systolic and diastolic blood pressure stayed nearly the same. No health effects were found in this study.
Resumo:
Helsinki : The Finnish Tourist Association 1926
Resumo:
Selostus: Typpilannoituksen ja nostoajankohdan vaikutus varhaisperunan satoon
Resumo:
Sähkönkulutuksen lyhyen aikavälin ennustamista on tutkittu jo pitkään. Pohjoismaisien sähkömarkkinoiden vapautuminen on vaikuttanut sähkönkulutuksen ennustamiseen. Aluksi työssä perehdyttiin aiheeseen liittyvään kirjallisuuteen. Sähkönkulutuksen käyttäytymistä tutkittiin eri aikoina. Lämpötila tilastojen käyttökelpoisuutta arvioitiin sähkönkulutusennustetta ajatellen. Kulutus ennusteet tehtiin tunneittain ja ennustejaksona käytettiin yhtä viikkoa. Työssä tutkittiin sähkönkulutuksen- ja lämpötiladatan saatavuutta ja laatua Nord Poolin markkina-alueelta. Syötettävien tietojen ominaisuudet vaikuttavat tunnittaiseen sähkönkulutuksen ennustamiseen. Sähkönkulutuksen ennustamista varten mallinnettiin kaksi lähestymistapaa. Testattavina malleina käytettiin regressiomallia ja autoregressiivistä mallia (autoregressive model, ARX). Mallien parametrit estimoitiin pienimmän neliösumman menetelmällä. Tulokset osoittavat että kulutus- ja lämpötiladata on tarkastettava jälkikäteen koska reaaliaikaisen syötetietojen laatu on huonoa. Lämpötila vaikuttaa kulutukseen talvella, mutta se voidaan jättää huomiotta kesäkaudella. Regressiomalli on vakaampi kuin ARX malli. Regressiomallin virhetermi voidaan mallintaa aikasarjamallia hyväksikäyttäen.
Resumo:
Työn päätavoite on selvittää kuinka erityisesti sähkön markkinahinnan ennustamiseen ja johdannaismarkkinoiden tietämykseen perustuva lyhyen tähtäimen sähköjohdannaisten hyödyntäminen tapahtuu teollisessa energianhallinnassa. Tätä aihetta lähestytään luomalla prosessi lyhyen tähtäimen sähköjohdannaisten hyödyntämiselle. Prosessi esitellään ja selvitetään aina lähtökohdista todelliseen kaupankäyntiin asti erillisen esimerkkitehtaan avulla.Lyhyen tähtäimen sähköjohdannaisten hyödyntäminen teollisessa energianhallinnassa perustuu pääosin tulevaisuuden odotuksiin sähkön markkinahinnan kehittymisestä sekä tehtaiden operatiiviseen tilanteeseen. Operatiiviseen tilanteeseen perustuva lyhyen tähtäimen sähköjohdannaisten kaupankäynti on pääasiassa pitkän tähtäimen suojausten sopeuttamista lyhyelle tähtäimelle sopivaksi.Hinnan ennustamisella on suuri rooli lyhyen tähtäimen sähköjohdannaisten hyödyntämisprosessissa. Työssä esitelty hinnan ennustamismalli on sopiva päivä- ja viikkotason Nord Poolin Elspot -systeemihinnan ennustamiseen. Elspot -systeemihinnan ennustamismalli on suunniteltu käytännönläheiseksi ja sen perustana ovat todelliset fysikaaliset ja mitattavat suureet. Futuurimarkkinatietämys on tarpeen lyhyen tähtäimen johdannaisia käytettäessä. Työssä tutkitaan yleisiä markkinoiden odotuksia ja futuurimarkkinoiden tietoisuuden kehittymistä koskien tulevaa vallitsevaa tilannetta. Työssä luodaan myös työkalu, mikä auttaa kaupan laatijaa muodostamaan suuntaa-antavat todennäköisyydet eri hintanäkemyksille ja paikallistamaan mahdolliset markkinoiden epätodennäköiset hintaodotukset.Kokemukset Elspot -systeemihinnan ennustamismallin soveltamisesta ovat lupaavia. Lisäksi havainnot futuurimarkkinoiden käyttäytymisestä Nord Poolissa ja muodostettu työkalu suuntaa-antavien todennäköisyyksien selvittämiseksi auttavat kaupan laatijaa päätöksenteossa. Lyhyen tähtäimen sähköjohdannaisten hyödyntäminen teollisessa energianhallinnassa on periaatteessa mahdollista esitellyn prosessin avulla, vaikka täydellinen käyttöönotto vaatisi vielä joitakin järjestelyjä. Keskittymällä tilanteisiin jotka työssä kuvatulla prosessilla ovat hoidettavissa, työssä määritellyllä menettelyllä on mahdollisuudet saavuttaa epäedullisen hintakehityksen riskin väheneminen ja parempi taloudellinen tulos teollisen energianhallinnan sähkökaupankäynnissä.