13 resultados para NOTIS Circulation Committee

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, A4 B2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this thesis was to study the removal of gases from paper mill circulation waters experimentally and to provide data for CFD modeling. Flow and bubble size measurements were carried out in a laboratory scale open gas separation channel. Particle Image Velocimetry (PIV) technique was used to measure the gas and liquid flow fields, while bubble size measurements were conducted using digital imaging technique with back light illumination. Samples of paper machine waters as well as a model solution were used for the experiments. The PIV results show that the gas bubbles near the feed position have the tendency to escape from the circulation channel at a faster rate than those bubbles which are further away from the feed position. This was due to an increased rate of bubble coalescence as a result of the relatively larger bubbles near the feed position. Moreover, a close similarity between the measured slip velocities of the paper mill waters and that of literature values was obtained. It was found that due to dilution of paper mill waters, the observed average bubble size was considerably large as compared to the average bubble sizes in real industrial pulp suspension and circulation waters. Among the studied solutions, the model solution has the highest average drag coefficient value due to its relatively high viscosity. The results were compared to a 2D steady sate CFD simulation model. A standard Euler-Euler k-ε turbulence model was used in the simulations. The channel free surface was modeled as a degassing boundary. From the drag models used in the simulations, the Grace drag model gave velocity fields closest to the experimental values. In general, the results obtained from experiments and CFD simulations are in good qualitative agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation: S drive = H steam (ρ down + ρ mix) g where: ρ down - density of water in downcomer tubes; ρ mix - density of water in riser tubes; H steam - height of steam content section; g - acceleration of gravity. In steam boilers with natural circulation the circulation rate is usually between 10 and 30. Thus, consumption of water in the circulation circuit “circulation rate times” more than steam output of the boiler. There are two aspects of the design of natural water circulation loops. One is to ensure a sufficient mass flux of circulating water to avoid burnout of evaporator tubes. The other is to avoid tube wall temperature fluctuation and tube vibration due to oscillation of circulation velocity. The design criteria are therefore reduced, in principle, to those of critical heat flux, critical flow rate for burnout, and flow instability. In practical design, however, the circulation velocity and the void fraction at the evaporator tube outlet are used as the design criteria (Seikan I., et. al., 1999). This study has been made with assumption that the heat flux in the furnace of the boiler even all the time. The target of the study was to define the circulation rate of the boiler, thus average heat flux do not change it. I would like to acknowledge professionals from “Foster Wheeler” company for good and comfortable cooperation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, A-B4 C2. - S. [2] tyhjä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, D4 E2. - S. [2] tyhjä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, E3-E4 F3. - S. [2] ja [42] tyhjä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, B3. - S. [2] tyhjä.