4 resultados para HT furnace energy management
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
The energy consumption by ICT (Information and Communication Technology) equipment is rapidly increasing which causes a significant economic and environmental problem. At present, the network infrastructure is becoming a large portion of the energy footprint in ICT. Thus the concept of energy efficient or green networking has been introduced. Now one of the main concerns of network industry is to minimize energy consumption of network infrastructure because of the potential economic benefits, ethical responsibility, and its environmental impact. In this paper, the energy management strategies to reduce the energy consumed by network switches in LAN (Local Area Network) have been developed. According to the lifecycle assessment of network switches, during usage phase, the highest amount of energy consumed. The study considers bandwidth, link load and traffic matrixes as input parameters which have the highest contribution in energy footprint of network switches during usage phase and energy consumption as output. Then with the objective of reducing energy usage of network infrastructure, the feasibility of putting Ethernet switches hibernate or sleep mode was investigated. After that, the network topology was reorganized using clustering method based on the spectral approach for putting network switches to hibernate or switched off mode considering the time and communications among them. Experimental results show the interest of this approach in terms of energy consumption
Resumo:
Automation technologies are widely acclaimed to have the potential to significantly reduce energy consumption and energy-related costs in buildings. However, despite the abundance of commercially available technologies, automation in domestic environments keep on meeting commercial failures. The main reason for this is the development process that is used to build the automation applications, which tend to focus more on technical aspects rather than on the needs and limitations of the users. An instance of this problem is the complex and poorly designed home automation front-ends that deter customers from investing in a home automation product. On the other hand, developing a usable and interactive interface is a complicated task for developers due to the multidisciplinary challenges that need to be identified and solved. In this context, the current research work investigates the different design problems associated with developing a home automation interface as well as the existing design solutions that are applied to these problems. The Qualitative Data Analysis approach was used for collecting data from research papers and the open coding process was used to cluster the findings. From the analysis of the data collected, requirements for designing the interface were derived. A home energy management functionality for a Web-based home automation front-end was developed as a proof-of-concept and a user evaluation was used to assess the usability of the interface. The results of the evaluation showed that this holistic approach to designing interfaces improved its usability which increases the chances of its commercial success.
Resumo:
The aim of this master’s thesis was to map the management accounting processes and reporting of an internal service unit. The research was conducted in energy services in a forest industry company. Research questions and the results of the study are highly specific for the case unit although some generalizable features of management accounting in internal service units under shared services were searched. The research was carried out as a qualitative action research and a single case study. Internal benchmarking was used to find best practices from other units and to get a comprehensive understanding of the financial processes of the case company. Empirical data for the study was collected with participant observation, interviews of experts and by exploring internal company documents. A literature review was conducted to outline the subject and to support the study. Although the management accounting processes of the case unit were found to be on a good level, some improvement ideas were presented. Results of the research show that the needs of the customers are in the key role in the processes of an internal service unit. Management accounting and reporting need to support the company strategy and management decision-making. To evaluate the performance of the service unit both financial and non-financial measures are needed.
Resumo:
Energy efficient policies are being applied to network protocols, devices and classical network management systems. Researchers have already studied in depth each of those fields, including for instance a long monitoring processes of various number of individual ICT equipment from where power models are constructed. With the development of smart meters and emerging protocols such as SNMP and NETCONF, currently there is an open field to couple the power models, translated to the expected behavior, with the realtime energy measurements. The goal is to derive a comparison on the power data between both of the processes in the direction of detection for possible deviations on the expected results. The logical assumption is that a fault in the usage of a particular device will not only increase its own energy usage, but also may cause additional consumption on the other devices part of the network. A platform is developed to monitor and analyze the retrieved power data of a simulated enterprise ICT infrastructure. Moreover, smart algorithms are developed which are aware of the different states that are occurring on each device during their typical use phase, as well as to detect and isolate possible anomalies. The produced results are obtained and validated with the use of Cisco switches and routers, Dell Precision stations and Raritan PDU as part of the monitored infrastructure.