69 resultados para DIRECT ANTENNA MODULATION
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
Direct torque control (DTC) is a new control method for rotating field electrical machines. DTC controls directly the motor stator flux linkage with the stator voltage, and no stator current controllers are used. With the DTC method very good torque dynamics can be achieved. Until now, DTC has been applied to asynchronous motor drives. The purpose of this work is to analyse the applicability of DTC to electrically excited synchronous motor drives. Compared with asynchronous motor drives, electrically excited synchronous motor drives require an additional control for the rotor field current. The field current control is called excitation control in this study. The dependence of the static and dynamic performance of DTC synchronous motor drives on the excitation control has been analysed and a straightforward excitation control method has been developed and tested. In the field weakening range the stator flux linkage modulus must be reduced in order to keep the electro motive force of the synchronous motor smaller than the stator voltage and in order to maintain a sufficient voltage reserve. The dynamic performance of the DTC synchronous motor drive depends on the stator flux linkage modulus. Another important factor for the dynamic performance in the field weakening range is the excitation control. The field weakening analysis considers both dependencies. A modified excitation control method, which maximises the dynamic performance in the field weakening range, has been developed. In synchronous motor drives the load angle must be kept in a stabile working area in order to avoid loss of synchronism. The traditional vector control methods allow to adjust the load angle of the synchronous motor directly by the stator current control. In the DTC synchronous motor drive the load angle is not a directly controllable variable, but it is formed freely according to the motor’s electromagnetic state and load. The load angle can be limited indirectly by limiting the torque reference. This method is however parameter sensitive and requires a safety margin between the theoretical torque maximum and the actual torque limit. The DTC modulation principle allows however a direct load angle adjustment without any current control. In this work a direct load angle control method has been developed. The method keeps the drive stabile and allows the maximal utilisation of the drive without a safety margin in the torque limitation.
Resumo:
The subject of this study is the use of direct cinema style in documentary film. The main purpose of this thesis was to the research the ways in which direct cinema style attempts to show and achieve truth in documentary films. The following questions were posed: Is it possible to depict reality in a documentary film; how does the choice of using this style affect the final documentary? The essential purpose of this study was to try to see whether the direct cinema style works when trying to achieve truth in a documentary film. This work consints of two elements, the theoretical part and the short documentary. The theoretical part deals with the history, the truth, and the direct cinema- style in documentaries. The theoretical information of direct cinema has been used when making the short documentary. In the documentary Tuloaula 2 I have studied the way in which using direct cinema -style works in practise. The documentary has followed as strictly as possible the direct cinema style. I was the director, the cameraman and the editor of my documentary film. In the documentary film Tuloaula 2 it appeared that the direct cinema style works best when filming everyday life. By using this style it is easy for the director to observe and leave his own persona in the background. The strength in using the direct cinema style is that it enables the viewer to build his/her own impression on the subject. Even though the direct cinema style aims to achieve objectivity the director has to make numerous subjective choices during both the filming and the editing process. These subjective choices automatically effect the "truth" of the documentary film. The difficulty in a direct cinema style is the large amount of material. This often leads to a long editing phase, which is not often possible in the busy production schedules. The direct cinema style is not at its best when shooting people who are passive because their attention often focuses too much on the camera. In general, the best way to make a documentary film would be to use many documentary styles in one film and not to srictly concentrate on only one style.
Resumo:
Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.
Resumo:
Verkkovaihtosuuntaajalla pystytään muuntamaan tasajännite vaihtojännitteeksi ja päinvastoin. Verkkovaihtosuuntaajan toiminta perustuu tehokytkinten ohjaukseen ja sopivan modulointimenetelmän käyttöön. Vektorisäädössä vaihtosuuntaajanvirrat ja jännitteet esitetään kompleksitasossa, jolloin virta- ja jännitekomponentit voidaan esittää vektoreina. Vektorisäädössä verkkovaihtosuuntaajan ohjaustoteutetaan laskemalla kompleksitasossa vektoreille arvot, jotka tuottavat vaihtosuuntaajan lähtöön halutun vektorin. Koska FPGA-piirit mahdollistavat nopean rinnakkaisen laskennan, soveltuvat ne hyvin vektorisäädön toteuttamiseen. FPGA-piirien rakenteesta johtuen on säätöjärjestelmän suunnittelussa huomioitava kiinteän pilkun lukujen riittävä bittileveys ja järjestelmän diskretointiaika. Työssä suunnitellaan verkkovaihtosuuntaajan vektorisäätö ja tutkitaan bittileveyden vaikutusta säädön toteuttamiseen FPGA-piirillä. Bittileveyden tarkasteluun esitetään käytettäväksi tilastollisia menetelmiä. Työssä tarkastellaan kiinteän pilkun järjestelmän ja liukulukujärjestelmän erosuureen tilastollisia tunnusmerkkejä sekä histogrammia. Tarkasteluissa huomattiin, että maksimivirhe itsessään ei tarjoa riittävästi tietoa erosuureen jakautumisesta. Näin ollen maksimivirhe ei ole kaikissa tilanteissa sovelias menetelmä riittävän bittitarkkuuden määrittämiseen. Työssä esitetään riittävän bittitarkkuuden määrittelemiseen käytettäväksi otossuureista otosvarianssia, keskipoikkeamaa ja vaihteluväliä.
Resumo:
In distributed energy production, permanent magnet synchronous generators (PMSG) are often connected to the grid via frequency converters, such as voltage source line converters. The price of the converter may constitute a large part of the costs of a generating set. Some of the permanent magnet synchronous generators with converters and traditional separately excited synchronous generators couldbe replaced by direct-on-line (DOL) non-controlled PMSGs. Small directly networkconnected generators are likely to have large markets in the area of distributed electric energy generation. Typical prime movers could be windmills, watermills and internal combustion engines. DOL PMSGs could also be applied in island networks, such as ships and oil platforms. Also various back-up power generating systems could be carried out with DOL PMSGs. The benefits would be a lower priceof the generating set and the robustness and easy use of the system. The performance of DOL PMSGs is analyzed. The electricity distribution companies have regulations that constrain the design of the generators being connected to the grid. The general guidelines and recommendations are applied in the analysis. By analyzing the results produced by the simulation model for the permanent magnet machine, the guidelines for efficient damper winding parameters for DOL PMSGs are presented. The simulation model is used to simulate grid connections and load transients. The damper winding parameters are calculated by the finite element method (FEM) and determined from experimental measurements. Three-dimensional finite element analysis (3D FEA) is carried out. The results from the simulation model and 3D FEA are compared with practical measurements from two prototype axial flux permanent magnet generators provided with damper windings. The dimensioning of the damper winding parameters is case specific. The damper winding should be dimensioned based on the moment of inertia of the generating set. It is shown that the damper winding has optimal values to reach synchronous operation in the shortest period of time after transient operation. With optimal dimensioning, interferenceon the grid is minimized.
Resumo:
Thedirect torque control (DTC) has become an accepted vector control method besidethe current vector control. The DTC was first applied to asynchronous machines,and has later been applied also to synchronous machines. This thesis analyses the application of the DTC to permanent magnet synchronous machines (PMSM). In order to take the full advantage of the DTC, the PMSM has to be properly dimensioned. Therefore the effect of the motor parameters is analysed taking the control principle into account. Based on the analysis, a parameter selection procedure is presented. The analysis and the selection procedure utilize nonlinear optimization methods. The key element of a direct torque controlled drive is the estimation of the stator flux linkage. Different estimation methods - a combination of current and voltage models and improved integration methods - are analysed. The effect of an incorrect measured rotor angle in the current model is analysed andan error detection and compensation method is presented. The dynamic performance of an earlier presented sensorless flux estimation method is made better by improving the dynamic performance of the low-pass filter used and by adapting the correction of the flux linkage to torque changes. A method for the estimation ofthe initial angle of the rotor is presented. The method is based on measuring the inductance of the machine in several directions and fitting the measurements into a model. The model is nonlinear with respect to the rotor angle and therefore a nonlinear least squares optimization method is needed in the procedure. A commonly used current vector control scheme is the minimum current control. In the DTC the stator flux linkage reference is usually kept constant. Achieving the minimum current requires the control of the reference. An on-line method to perform the minimization of the current by controlling the stator flux linkage reference is presented. Also, the control of the reference above the base speed is considered. A new estimation flux linkage is introduced for the estimation of the parameters of the machine model. In order to utilize the flux linkage estimates in off-line parameter estimation, the integration methods are improved. An adaptive correction is used in the same way as in the estimation of the controller stator flux linkage. The presented parameter estimation methods are then used in aself-commissioning scheme. The proposed methods are tested with a laboratory drive, which consists of a commercial inverter hardware with a modified software and several prototype PMSMs.
Resumo:
Tämän diplomityön tavoitteena on selvittää, mitä alueellisia tekijöitä suomalaiset yritykset ottavat huomioon valitessaan sopivaa sijaintia suoralle investoinnille Venäjän sisällä. Muutamia yrityksen sisäisiä tekijöitä käytetään taustamuuttujina selittämään sijaintitekijöiden painotuksissa havaittavia eroja erilaisten yritysten välillä. Venäjän alueita vertaillaan lopuksi painotusten valossa. Työn ensimmäisessä osassa keskitytään suorien ulkomaisten investointien teoreettiseen taustaan. Aiempia tutkimuksia käydään läpi, jotta tekijät, joilla on havaittu olevan vaikutusta investointien sijoittumiseen maan sisällä, saadaan kartoitettua. Työn jälkimmäinen osa perustuu yrityskyselyn avulla kerättyyn empiiriseen aineistoon. Aineiston avulla selvitetään mitä tekijöitä suomalaisyritykset huomioivat sijaintipäätöstä tehdessään. Tulosten valossa on ilmeistä, että alueen markkinapotentiaali on suomalaisyrityksissä tärkein huomioitava tekijä investoinnin sijainnista päätettäessä. Myös infrastruktuuri ja kustannushyödyt vaikuttavat päätökseen. Erityyppisten yritysten painotukset ovat hyvin samanlaisia. Moskova ja Pietari vastaavat Venäjän alueista parhaiten suomalaisyritysten investoinnin sijainnille asettamia kriteerejä.
Resumo:
Tutkimuksen päätavoitteena oli selvittää suomalaisten suorien investointien maan valintaan vaikuttavia tekijöitä Itä- ja Keski-Euroopan kymmenessä siirtymätaloudessa. Empiirisessä osuudessa tarkasteltiin suomalaisten yritysten tärkeimpiä sijaintitekijöitä alueella ja yrityskohtaisten tekijöiden vaikutusta sijaintitekijöihin. Tutkimuksessa selvitettiin myös yritysten päämotiiveja investoida maihin. Laaditun investointikriteeristön mukaan maat pystyttiin laittamaan paremmuusjärjestykseen suomalaisen investoijan kannalta. Empiirisen osuuden aineisto kerättiin postikyselylomakkeella yrityksiltä, joilla on tai jotka ovat suunnittelemassa investointeja näihin maihin. Tutkimusote oli kvantitatiivinen. Tutkimustulokset osoittavat, että suomalaiset investoijat valitsevat Itä- ja Keski-Euroopan maan investointikohteeksi pääasiassa markkinapotentiaalin ja edullisten kustannusten perusteella. Myös infrastruktuuri vaikuttaa maan valintaan. Eri aloilla toimivien yritysten sijaintitekijöiden painotuksissa havaittiin eroja. Yrityksen koko ja päämotiivi vaikuttivat sijaintitekijöiden painotuksiin. Investointikriteereiden mukaan kaksi parasta investointimaata suomalaisille investoijille ovat Puola ja Viro. Vertailtaessa investointikriteereitä toteutuneisiin investointeihin voidaan todeta, että suomalaiset investoijat eivät ole hyödyntäneet investoinneilla saatavia etuja kaikissa kohdemaissa.
Resumo:
Työssä tarkastellaan olemassa olevan suoraa vääntömomentin säätöä käyttävän taajuudenmuuttajan soveltamista keskitaajuusalueella toimiviin induktiomoottorikäyttöihin. Keskinopeusalueen sovellusten pyörimisnopeudet ovat tyypillisesti 6000…30000rpm. Tällöin invertterin lähtötaajuuden on nelinapaista moottoria ohjattaessa ulotuttava 1000Hz:iin. ABB:n ACS600 taajuudenmuuttajan nykyinen syöttötaajuus ulottuu noin 400Hz:iin ja sen keskimääräinen kytkentätaajuus on luokkaa 3kHz. Taajuudenmuuttajan keskimääräistä kytkentätaajuutta ei haluta tästä merkittävästi nostaa, koska tällöin pääteasteen mitoitusta ja rakennetta on muutettava. Tarkastelussa keskitytään täten jännitemodulointiin, joka määrittelee invertterin lähtöjännitteen käyrämuodon ja pääteasteen tehokytkimien kytkentätaajuuden. Työssä esitetään suoran käämivuon säädön periaatetta soveltava 30-kulmainen modulointimenetelmä (30-modulointi), jolla moottorin syöttövirrasta voidaan eliminoida 5. ja 7. yliharmoninen komponentti. Yliharmonisten komponenttien eliminointi mahdollistaa passiivisilla komponenteilla toteutetun alipäästösuodattimen asentamisen invertterin lähtöön, jolloin moottorissa tapahtuvat tehohäviöt saadaan pieniksi. 30-moduloinnin ohjaukseen ja säätöön esitetään menetelmät, jotka mahdollistavat sen toteuttamisen nykyiseen taajuudenmuuttajaan ohjelmallisesti ilman suuria laitteistomuutoksia. 30-moduloinnin ominaisuuksia tarkastellaan analyyttisin menetelmin ja sen toimintaa testataan esitettyjen teorioiden perusteella simuloimalla. 30-moduloinnin ohjelmallinen implementointi nykyiseen ACS600:een mahdollistaa periaatteessa noin 600Hz:n syöttötaajuuden saavuttamisen. Tällöin invertterin keskimääräinen kytkentätaajuus voidaan säätää koko pyörimisnopeusalueella alle 4kHz:n tasolle.
Resumo:
This thesis presents the design and implementation of a GPS-signal source suitable for receiver measurements. The developed signal source is based on direct digital synthesis which generates the intermediate frequency. The intermediate frequency is transfered to the final frequency with the aid of an Inphase/Quadrature modulator. The modulating GPS-data was generated with MATLAB. The signal source was duplicated to form a multi channel source. It was shown that, GPS-signals ment for civil navigation are easy to generate in the laboratory. The hardware does not need to be technically advanced if navigation with high level of accuracy is not needed. It was also shown that, the Inphase/Quadrature modulator can function as a single side band upconverter even with a high intermediate frequency. This concept reduces the demands required for output filtering.