95 resultados para SYNTACTIC DEPENDENCY NETWORKS
Resumo:
Recent developments in power electronics technology have made it possible to develop competitive and reliable low-voltage DC (LVDC) distribution networks. Further, islanded microgrids—isolated small-scale localized distribution networks— have been proposed to reliably supply power using distributed generations. However, islanded operations face many issues such as power quality, voltage regulation, network stability, and protection. In this thesis, an energy management system (EMS) that ensures efficient energy and power balancing and voltage regulation has been proposed for an LVDC island network utilizing solar panels for electricity production and lead-acid batteries for energy storage. The EMS uses the master/slave method with robust communication infrastructure to control the production, storage, and loads. The logical basis for the EMS operations has been established by proposing functionalities of the network components as well as by defining appropriate operation modes that encompass all situations. During loss-of-powersupply periods, load prioritizations and disconnections are employed to maintain the power supply to at least some loads. The proposed EMS ensures optimal energy balance in the network. A sizing method based on discrete-event simulations has also been proposed to obtain reliable capacities of the photovoltaic array and battery. In addition, an algorithm to determine the number of hours of electric power supply that can be guaranteed to the customers at any given location has been developed. The successful performances of all the proposed algorithms have been demonstrated by simulations.
Resumo:
Our goal is to get better understanding of different kind of dependencies behind the high-level capability areas. The models are suitable for investigating present state capabilities or future developments of capabilities in the context of technology forecasting. Three levels are necessary for a model describing effects of technologies on military capabilities. These levels are capability areas, systems and technologies. The contribution of this paper is to present one possible model for interdependencies between technologies. Modelling interdependencies between technologies is the last building block in constructing a quantitative model for technological forecasting including necessary levels of abstraction. This study supplements our previous research and as a result we present a model for the whole process of capability modelling. As in our earlier studies, capability is defined as the probability of a successful task or operation or proper functioning of a system. In order to obtain numerical data to demonstrate our model, we conducted a questionnaire to a group of defence technology researchers where interdependencies between seven representative technologies were inquired. Because of a small number of participants in questionnaires and general uncertainties concerning subjective evaluations, only rough conclusions can be made from the numerical results
Resumo:
Langattomat lähiverkot ovat yleistyneet ja monin paikoin niillä pyritään täysin korvaamaan perinteiset kaapeloidut verkot. Samalla verkoissa välitettävät palvelut monipuolistuvat. Etenkin interaktiivisten sisältöjen ja viiveriippuvaisten palvelujen välittämisessä korostuvat verkolle asettavat vaatimukset suorituskyvystä ja palveluntasosta. Radiotaajuuksilla tapahtuva tiedonsiirto on ongelmallista siirtomedian jaetun luonteen vuoksi. Käytettäessä ympärisäteileviä antenneja jokainen kantomatkan päässä oleva asema kuulee lähetyksen, vaikkei se olisi sille suunnattu. Tämä luo turvallisuusongelman, mutta lisäksi heikentää tehokkuutta, koska nykyisellä antenniteknologialla vain yksi asema kerrallaan voi lähettää häiriöttä kantoalueellaan. Täsmälähetykset yhden lähteen ja useiden kohteiden välillä luovat erillisiä siirtolinkkejä. Olisi luontevampaa luoda yksi lähetysvirta, johon useat vastaanottajat voivat kytkeytyä. Kaistan säästön vastapainona on tarve luoda ja ylläpitää näitä yhteyksiä. Käyttäjien liikkuvuuden ja siirtotien vaihtelevien ominaisuuksien vuoksi langattoman verkon rakenne ja rajat ovat epäselviä. Näihin haasteisiin on vastattava sekä protokolla- että sovellustasolla. Tässä tutkielmassa käydään ensin läpi IEEE 802.11 -standardin mukaisen langattoman verkon perusteet ja sen ominaisuuksiin liittyvät tyypilliset ongelmakohdat. Yleis- ja ryhmälähetyksiä tarkastellaan ensin perinteisessä IEEE 802.3 standardin mukaisessa langallisessa lähiverkossa ja selvitetään, miten vastaavat ominaisuudet toteutuvat IEEE 802.11 standardien mukaisissa langattomissa verkoissa. Käyttötapaustutkimuksissa keskitytään rajatussa ympäristössä tapahtuviin ryhmälähetyksiin. Erityisesti tutkitaan langattomien ryhmälähetysten käyttökelpoisuutta sekä langattoman ympäristön asettamia erityisvaatimuksia.
Resumo:
This thesis is the Logistics Development Forum's assignment and the work dealing with the development of the Port of Helsinki as part of Helsinki hub. The Forum aims to develop logistics efficiency through public-private co-operation and development of the port is clearly dependent on both factors. Freight volumes in the Port of Helsinki are the biggest single factor in hub and, therefore, the role of the port of the entire hub development is strong. The aim is to look at how the port will develop as a result of changes in the foreign trade of Finland and the Northern European logistics trends in 25 years time period. Work includes the current state analysis and scenario work. The analyses are intended to find out, which trends are the most important in the port volume development. The change and effect of trends is examined through scenarios based on current state. Based on the work, the structure of Finnish export industry and international demand are in the key role in the port volume development. There is significant difference between demands of Finnish exporting products in different export markets and the development between the markets has different impacts on the port volumes by mass and cargo type. On the other hand, the Finnish economy is stuck in a prolonged recession and competition between ports has become a significant factor in the individual port's volume development. Ecological valuesand regulations have changed the competitive landscape and maritime transport emissions reductions has become an important competitive factor for short routes in the Baltic Sea, such as in the link between Helsinki and Tallinn.
Resumo:
Increasingly growing share of distributed generation in the whole electrical power system’s generating system is currently a worldwide tendency, driven by several factors, encircling mainly difficulties in refinement of megalopolises’ distribution networks and its maintenance; widening environmental concerns adding to both energy efficiency approaches and installation of renewable sources based generation, inherently distributed; increased power quality and reliability needs; progress in IT field, making implementable harmonization of needs and interests of different-energy-type generators and consumers. At this stage, the volume, formed by system-interconnected distributed generation facilities, have reached the level of causing broad impact toward system operation under emergency and post-emergency conditions in several EU countries, thus previously implementable approach of their preliminary tripping in case of a fault, preventing generating equipment damage and disoperation of relay protection and automation, is not applicable any more. Adding to the preceding, withstand capability and transient electromechanical stability of generating technologies, interconnecting in proximity of load nodes, enhanced significantly since the moment Low Voltage Ride-Through regulations, followed by techniques, were introduced in Grid Codes. Both aspects leads to relay protection and auto-reclosing operation in presence of distributed generation generally connected after grid planning and construction phases. This paper proposes solutions to the emerging need to ensure correct operation of the equipment in question with least possible grid refinements, distinctively for every type of distributed generation technology achieved its technical maturity to date and network’s protection. New generating technologies are equivalented from the perspective of representation in calculation of initial steady-state short-circuit current used to dimension current-sensing relay protection, and widely adopted short-circuit calculation practices, as IEC 60909 and VDE 0102. The phenomenon of unintentional islanding, influencing auto-reclosing, is addressed, and protection schemes used to eliminate an sustained island are listed and characterized by reliability and implementation related factors, whereas also forming a crucial aspect of realization of the proposed protection operation relieving measures.