52 resultados para DC power transmission
Resumo:
In the doctoral dissertation, low-voltage direct current (LVDC) distribution system stability, supply security and power quality are evaluated by computational modelling and measurements on an LVDC research platform. Computational models for the LVDC network analysis are developed. Time-domain simulation models are implemented in the time-domain simulation environment PSCAD/EMTDC. The PSCAD/EMTDC models of the LVDC network are applied to the transient behaviour and power quality studies. The LVDC network power loss model is developed in a MATLAB environment and is capable of fast estimation of the network and component power losses. The model integrates analytical equations that describe the power loss mechanism of the network components with power flow calculations. For an LVDC network research platform, a monitoring and control software solution is developed. The solution is used to deliver measurement data for verification of the developed models and analysis of the modelling results. In the work, the power loss mechanism of the LVDC network components and its main dependencies are described. Energy loss distribution of the LVDC network components is presented. Power quality measurements and current spectra are provided and harmonic pollution on the DC network is analysed. The transient behaviour of the network is verified through time-domain simulations. DC capacitor guidelines for an LVDC power distribution network are introduced. The power loss analysis results show that one of the main optimisation targets for an LVDC power distribution network should be reduction of the no-load losses and efficiency improvement of converters at partial loads. Low-frequency spectra of the network voltages and currents are shown, and harmonic propagation is analysed. Power quality in the LVDC network point of common coupling (PCC) is discussed. Power quality standard requirements are shown to be met by the LVDC network. The network behaviour during transients is analysed by time-domain simulations. The network is shown to be transient stable during large-scale disturbances. Measurement results on the LVDC research platform proving this are presented in the work.
Resumo:
Switching power supplies are usually implemented with a control circuitry that uses constant clock frequency turning the power semiconductor switches on and off. A drawback of this customary operating principle is that the switching frequency and harmonic frequencies are present in both the conducted and radiated EMI spectrum of the power converter. Various variable-frequency techniques have been introduced during the last decade to overcome the EMC problem. The main objective of this study was to compare the EMI and steady-state performance of a switch mode power supply with different spread-spectrum/variable-frequency methods. Another goal was to find out suitable tools for the variable-frequency EMI analysis. This thesis can be divided into three main parts: Firstly, some aspects of spectral estimation and measurement are presented. Secondly, selected spread spectrum generation techniques are presented with simulations and background information. Finally, simulations and prototype measurements from the EMC and the steady-state performance are carried out in the last part of this work. Combination of the autocorrelation function, the Welch spectrum estimate and the spectrogram were used as a substitute for ordinary Fourier methods in the EMC analysis. It was also shown that the switching function can be used in preliminary EMC analysis of a SMPS and the spectrum and autocorrelation sequence of a switching function correlates with the final EMI spectrum. This work is based on numerous simulations and measurements made with the prototype. All these simulations and measurements are made with the boost DC/DC converter. Four different variable-frequency modulation techniques in six different configurations were analyzed and the EMI performance was compared to the constant frequency operation. Output voltage and input current waveforms were also analyzed in time domain to see the effect of the spread spectrum operation on these quantities. According to the results presented in this work, spread spectrum modulation can be utilized in power converter for EMI mitigation. The results from steady-state voltage measurements show, that the variable-frequency operation of the SMPS has effect on the voltage ripple, but the ripple measured from the prototype is still acceptable in some applications. Both current and voltage ripple can be controlled with proper main circuit and controller design.
Resumo:
This master’s thesis studies the case company’s current purchase invoice process and the challenges that are related to it. Like most of other master’s thesis this study consists of both theoretical- and empirical parts. The purpose of this work is to combine theoretical and empirical parts together so that the theoretical part brings value to the empirical case study. The case company’s main business is frequency converters for both low voltage AC & DC drives and medium voltage AC Drives which are used across all industries and applications. The main focus of this study is on the current invoice process modelling. When modelling the existing process with discipline and care, current challenges can be understood better. Empirical study relays heavily on interviews and existing, yet fragmented, data. This, along with own calculations and analysis, creates the foundation for the empirical part of this master’s thesis.
Resumo:
Gear rattle is a phenomenon that occurs when idling or lightly loaded gears collide due to engine’s torque fluctuations. This behaviour is related to vibration behaviour of the transmission system. Aim of this master’s thesis is to evaluate Adams and Adams/Machinery as a simulation tools for modelling the rattle e ect in a transmission system. A case study of tractor’s power take-o driveline, suspected to be prone to rattle, is performed in this work. Modelling methods used by Adams in this type of study are presented in the theory section while simulation model build with the software during this work is presented in the results. The Machinery toolbox is used to create gears and bearings while other model components are created with standard Adams tool set. Geometries and excitations are exported from other softwares. Results were obtained from multiple variations of a base model. These result sets and literature review suggest that Adams/Machinery may not be the most suitable tool for rattle analysis. While the system behaviour was partially captured, for accurate modelling user-written routines must be used which may be more easily performed with other tools. Further research about this topic is required.
Resumo:
Today, renewable energy technologies and modern power electronics have made it feasible to implement low voltage direct current (LVDC) microgrids (MGs) ca-pable to island operation. Such LVDC networks are particularly useful in remote areas. However, there are still pending issues in island operated LVDC MGs like electrical safety and controlled operation, which should be addressed before wide-scale implementation. This thesis is focused on the overall protection of an island operated LVDC network concept, including protection against electrical shocks, mains equipment protection and protection of photovoltaic (PV) power sources and battery energy storage systems (BESSs). The topic is approached through ex-amination of the safety hazards and the appropriate methods to protect against them, comprising considerations for earthing system selection and realisation of the protection system.
Resumo:
Ajoneuvoissa, kuten busseissa, käytetään yleensä 24 VDC järjestelmiä ja tämä ei muutu myöskään sähköajoneuvojen kohdalla. Sähköajoneuvoissakin tarvitaan siis 24 VDC matalajänniteakustoja valoille, pyyhkijöille ja muille matalan jännitteen järjestelmille. Lisäksi sähköajoneuvoissa on esimerkiksi ilmastointi ja paineilmankompressori, jotka tarvitsevat taajuusmuuttajan pyörittämään niitä. Tässä työssä suunnitellaan suuren virran piilevy DC/DC-muuntimeen, joka on osa ajoneuvokäyttöön suunnitellun invertterin ja DC/DC-muuntimen yhdistelmälaitetta. Työn pääpaino on piirilevyn suunnittelussa, mutta työssä kerrotaan lyhyesti koko laitteen kytkentä ja käyttötarkoitus. Työssä kerrotaan myös tehopiirilevylle tulevien komponenttien valinta, mitoitus ja jäähdytys. Käydään läpi suuren virran piirilevysuunnittelun mitoitusperiaatteet ja mitä seikkoja siinä erityisesti tulee ottaa huomioon. Lisäksi käsitellään piirilevyn liityntöjä ja virtakiskojen lämpenemää virranahtautumisen takia. Suunniteltua piirilevyä mitataan ja sen toimintaa kokeillaan prototyyppilaitteessa. Protoyyppilaitteella havaitaan virtakiskojen lämpenevän liikaa ja huomataan ongelma kytkenssä. Kytkentää korjattiin ja toimintaa analysoitiin uudestaan, jonka jälkeen havaittiin piirilevyn lämpenemän tippuneen 20 °C. Lopputuloksena piirilevyn lämpenemä, korjatulla kytkennällä, on suunnitellun mukainen. Lopussa esitetään piirilevyn korvaamista moduuliratkaisulla laitteen parantamiseksi sarjatuotantoon.
Power Electronic Converters in Low-Voltage Direct Current Distribution – Analysis and Implementation
Resumo:
Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.