66 resultados para gradient index optics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, I4 K1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, F4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, C4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, A4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, L4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, E4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arkit: 1 arkintunnukseton lehti, G4 H2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this research was to make an overall sight to VIX® and how it can be used as a stock market indicator. Volatility index often referred as the fear index, measures how much it costs for investor to protect his/her S&P 500 position from fluctuations with options. Over the relatively short history of VIX it has been a successful timing coordinator and it has given incremental information about the market state adding its own psychological view of the amount of fear and greed. Correctly utilized VIX information gives a considerable advantage in timing market actions. In this paper we test how VIX works as a leading indicator of broad stock market index such as S&P 500 (SPX). The purpose of this paper is to find a working way to interpret VIX. The various tests are made on time series data ranging from the year 1990 to the year 2010. The 10-day simple moving average strategy gave significant profits from the whole time when VIX data is available. Strategy was able to utilize the increases of SPX in example portfolio value and was able to step aside when SPX was declining. At the times when portfolio was aside of S it was on safety fund like on treasury bills getting an annual yield of 3 percent. On the other side just a static number’s of VIX did not work as indicators in a profit making way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atherosclerotic vascular disease is the leading cause of death in the Western world. Its main three manifestations are coronary heart disease, cerebrovascular disease, and peripheral arterial disease. Asymptomatic peripheral arterial disease is usually diagnosed using the ankle brachial index, and values ≤ 0.90 are used to determine the diagnosis. The classical risk factors of peripheral arterial disease, such as smoking and diabetes, are well known and early interventions are mandatory to improve the prognosis. What is not well known is the role of inflammation as a risk factor. Yet, a novel approach to cardiovascular diseases is the measurement of endothelial function. In this thesis, we studied the ankle-brachial index, C-reactive protein and endothelial function in a cardiovascular risk population. A total of 2856 subjects were invited to the study and 2085 (73%) responded. From these subjects, a cohort of 1756 risk persons was screened. We excluded the subjects with previously known cardiovascular disease or diabetes, because they were already under systematic follow-up. Out of the study subjects, 983 (56%) were women and 773 (44%) men. The ankle brachial index and high-sensitivity C-reactive protein were measured from 1047 subjects. Endothelial function was assessed by measuring reactive hyperemia pulse amplitude tonometry from 66 subjects with borderline peripheral arterial disease. In this study, smoking was a crucial risk factor for peripheral arterial disease. Subclinical peripheral arterial disease seems to be more common in hypertensive patients even without comorbidities. The measurement of the ankle brachial index is an efficient method to identify patients at an increased cardiovascular risk. High-sensitivity C-reactive protein did not correlate with the ankle brachial index or peripheral arterial disease. Instead, it correlated with measures of obesity. In a cardiovascular risk population with borderline peripheral arterial disease, nearly every fourth subject had endothelial dysfunction. This might point out a subgroup of individuals in need of more intensive treatment for their risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This master’s thesis is devoted to study different heat flux measurement techniques such as differential temperature sensors, semi-infinite surface temperature methods, calorimetric sensors and gradient heat flux sensors. The possibility to use Gradient Heat Flux Sensors (GHFS) to measure heat flux in the combustion chamber of compression ignited reciprocating internal combustion engines was considered in more detail. A. Mityakov conducted an experiment, where Gradient Heat Flux Sensor was placed in four stroke diesel engine Indenor XL4D to measure heat flux in the combustion chamber. The results which were obtained from the experiment were compared with model’s numerical output. This model (a one – dimensional single zone model) was implemented with help of MathCAD and the result of this implementation is graph of heat flux in combustion chamber in relation to the crank angle. The values of heat flux throughout the cycle obtained with aid of heat flux sensor and theoretically were sufficiently similar, but not identical. Such deviation is rather common for this type of experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negative refractive index materials and propagation of electromagnetic waves in them started to draw attention of scientists not so long ago. This review highlights historically important and recent papers on practical and theoretical aspects related to these issues. Namely, basic properties and peculiarities of such materials related to both their design and wave propagation in them, experimental verification of predictions theoretically made for them, possible practical applications and prospects in this area are considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scanning optics create different types of phenomena and limitation to cladding process compared to cladding with static optics. This work concentrates on identifying and explaining the special features of laser cladding with scanning optics. Scanner optics changes cladding process energy input mechanics. Laser energy is introduced into the process through a relatively small laser spot which moves rapidly back and forth, distributing the energy to a relatively large area. The moving laser spot was noticed to cause dynamic movement in the melt pool. Due to different energy input mechanism scanner optic can make cladding process unstable if parameter selection is not done carefully. Especially laser beam intensity and scanning frequency have significant role in the process stability. The laser beam scanning frequency determines how long the laser beam affects with specific place local specific energy input. It was determined that if the scanning frequency in too low, under 40 Hz, scanned beam can start to vaporize material. The intensity in turn determines on how large package this energy is brought and if the intensity of the laser beam was too high, over 191 kW/cm2, laser beam started to vaporize material. If there was vapor formation noticed in the melt pool, the process starts to resample more laser alloying due to deep penetration of laser beam in to the substrate. Scanner optics enables more flexibility to the process than static optics. The numerical adjustment of scanning amplitude enables clad bead width adjustment. In turn scanner power modulation (where laser power is adjusted according to where the scanner is pointing) enables modification of clad bead cross-section geometry when laser power can be adjusted locally and thus affect how much laser beam melts material in each sector. Power modulation is also an important factor in terms of process stability. When a linear scanner is used, oscillating the scanning mirror causes a dwell time in scanning amplitude border area, where the scanning mirror changes the direction of movement. This can cause excessive energy input to this area which in turn can cause vaporization and process instability. This process instability can be avoided by decreasing energy in this region by power modulation. Powder feeding parameters have a significant role in terms of process stability. It was determined that with certain powder feeding parameter combinations powder cloud behavior became unstable, due to the vaporizing powder material in powder cloud. Mainly this was noticed, when either or both the scanning frequency or powder feeding gas flow was low or steep powder feeding angle was used. When powder material vaporization occurred, it created vapor flow, which prevented powder material to reach the melt pool and thus dilution increased. Also powder material vaporization was noticed to produce emission of light at wavelength range of visible light. This emission intensity was noticed to be correlated with the amount of vaporization in the powder cloud.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Julkaisussa: Atlas van zeevaert en koophandel door de geheele weereldt