40 resultados para frequency modulation (FM)
Resumo:
Transportation of fluids is one of the most common and energy intensive processes in the industrial and HVAC sectors. Pumping systems are frequently subject to engineering malpractice when dimensioned, which can lead to poor operational efficiency. Moreover, pump monitoring requires dedicated measuring equipment, which imply costly investments. Inefficient pump operation and improper maintenance can increase energy costs substantially and even lead to pump failure. A centrifugal pump is commonly driven by an induction motor. Driving the induction motor with a frequency converter can diminish energy consumption in pump drives and provide better control of a process. In addition, induction machine signals can also be estimated by modern frequency converters, dispensing with the use of sensors. If the estimates are accurate enough, a pump can be modelled and integrated into the frequency converter control scheme. This can open the possibility of joint motor and pump monitoring and diagnostics, thereby allowing the detection of reliability-reducing operating states that can lead to additional maintenance costs. The goal of this work is to study the accuracy of rotational speed, torque and shaft power estimates calculated by a frequency converter. Laboratory tests were performed in order to observe estimate behaviour in both steady-state and transient operation. An induction machine driven by a vector-controlled frequency converter, coupled with another induction machine acting as load was used in the tests. The estimated quantities were obtained through the frequency converter’s Trend Recorder software. A high-precision, HBM T12 torque-speed transducer was used to measure the actual values of the aforementioned variables. The effect of the flux optimization energy saving feature on the estimate quality was also studied. A processing function was developed in MATLAB for comparison of the obtained data. The obtained results confirm the suitability of this particular converter to provide accurate enough estimates for pumping applications.
Resumo:
Tämän pro gradu– tutkielman tavoitteena oli testata täytettyjen taukojen (er ja erm) esiintymistiheyttä, sijaintia kieliopillisessa rakenteessa sekä funktioita Kjellmerin (2003) korpus-tutkimuksessa. Materiaalina käytin viiden yhdysvaltalaisen poliitikon puhetta keskusteluohjelmasta Larry King Live. Tutkimuksessani sovelsin Kjellmerin tutkimusmenetelmiä, joita muokkasin huomattavasti suppeampaan materiaaliini sopiviksi. Lähestymistapani oli täten induktiivinen toisin kuin testatussa tutkimuksessa. Materiaalini oli tarkoituksellisesti rajattu, sillä halusin selvittää, kuvaavatko Kjellmerin laajaan materiaaliin perustuvat tutkimustulokset myös täytettyjen taukojen käyttöä suppeammassa materiaalissa. Materiaalini (kokonaisuudessaan 101 minuuttia) transkriboin ortografisesti. Analyysissäni arvioin täytettyjen taukojen esiintymistiheyden puhujakohtaisesti ja koko ryhmälle suhteuttamalla täytettyjen taukojen lukumäärän kokonaissanamäärään. Tämän jälkeen tein perinteisen kielioppianalyysin rakenteista, joita edeltää tai joissa esiintyy täytetty tauko, ja täytettyjen taukojen sijainnin perusteella luokittelin ne sana-, lauseke-, ja lausetasolle. Lopuksi analysoin täytettyjen taukojen käyttöä soveltaen Kjellmerin ehdottamia funktioita (hesitaatio, vuorottelujäsennyksen merkitseminen, huomion herättäminen ja kontaktin luominen, korostus ja korjaus) ja niiden piirteitä omaan materiaaliini. Tutkimukseni perusteella täytetyt tauot esiintyvät tutkitun viiden poliitikon puheessa suhteellisen usein. Puhujakohtaiset eroavaisuudet olivat kuitenkin huomattavat. Kieliopillisen luokitteluni mukaan sana-, lauseke- ja lausetasot eivät täysin kuvaa täytettyjen taukojen sijoittumista, sillä täytetyt tauot edelsivät mm. määre-lauseita, jotka eivät vastaa lausetasoa englannin kielessä. Materiaalini funktioanalyysi osoitti, että täytetyt tauot yleensä vastaavat yhtä tai useampaa Kjellmerin ehdottamaa funktioita. Lisäksi tutkimukseni mukaan täytetyillä tauoilla on ainakin yksi rakenteellinen funktio. Analyysini perusteella Kjellmerin tutkimustulokset ovat siis pääosin sovellettavissa suppeampaan materiaaliin. Puutteiksi hänen tutkimuksessaan osoittautuivat funktioanalyysille tärkeän kontekstuaalisen informaation puute sekä keskittyminen täytettyihin taukoihin, jotka esiintyvät vain tietyissä kielioppirakenteissa. Yleisesti voin tutkimukseni pohjalta todeta, että täytetyt tauot ovat vielä vajaasti tunnettuja ja että kieliopillisen sijoituksen ja funktioiden lisätutkimus on tarpeellista.
Resumo:
The pumping processes requiring wide range of flow are often equipped with parallelconnected centrifugal pumps. In parallel pumping systems, the use of variable speed control allows that the required output for the process can be delivered with a varying number of operated pump units and selected rotational speed references. However, the optimization of the parallel-connected rotational speed controlled pump units often requires adaptive modelling of both parallel pump characteristics and the surrounding system in varying operation conditions. The available information required for the system modelling in typical parallel pumping applications such as waste water treatment and various cooling and water delivery pumping tasks can be limited, and the lack of real-time operation point monitoring often sets limits for accurate energy efficiency optimization. Hence, alternatives for easily implementable control strategies which can be adopted with minimum system data are necessary. This doctoral thesis concentrates on the methods that allow the energy efficient use of variable speed controlled parallel pumps in system scenarios in which the parallel pump units consist of a centrifugal pump, an electric motor, and a frequency converter. Firstly, the suitable operation conditions for variable speed controlled parallel pumps are studied. Secondly, methods for determining the output of each parallel pump unit using characteristic curve-based operation point estimation with frequency converter are discussed. Thirdly, the implementation of the control strategy based on real-time pump operation point estimation and sub-optimization of each parallel pump unit is studied. The findings of the thesis support the idea that the energy efficiency of the pumping can be increased without the installation of new, more efficient components in the systems by simply adopting suitable control strategies. An easily implementable and adaptive control strategy for variable speed controlled parallel pumping systems can be created by utilizing the pump operation point estimation available in modern frequency converters. Hence, additional real-time flow metering, start-up measurements, and detailed system model are unnecessary, and the pumping task can be fulfilled by determining a speed reference for each parallel-pump unit which suggests the energy efficient operation of the pumping system.
Resumo:
Scanning optics create different types of phenomena and limitation to cladding process compared to cladding with static optics. This work concentrates on identifying and explaining the special features of laser cladding with scanning optics. Scanner optics changes cladding process energy input mechanics. Laser energy is introduced into the process through a relatively small laser spot which moves rapidly back and forth, distributing the energy to a relatively large area. The moving laser spot was noticed to cause dynamic movement in the melt pool. Due to different energy input mechanism scanner optic can make cladding process unstable if parameter selection is not done carefully. Especially laser beam intensity and scanning frequency have significant role in the process stability. The laser beam scanning frequency determines how long the laser beam affects with specific place local specific energy input. It was determined that if the scanning frequency in too low, under 40 Hz, scanned beam can start to vaporize material. The intensity in turn determines on how large package this energy is brought and if the intensity of the laser beam was too high, over 191 kW/cm2, laser beam started to vaporize material. If there was vapor formation noticed in the melt pool, the process starts to resample more laser alloying due to deep penetration of laser beam in to the substrate. Scanner optics enables more flexibility to the process than static optics. The numerical adjustment of scanning amplitude enables clad bead width adjustment. In turn scanner power modulation (where laser power is adjusted according to where the scanner is pointing) enables modification of clad bead cross-section geometry when laser power can be adjusted locally and thus affect how much laser beam melts material in each sector. Power modulation is also an important factor in terms of process stability. When a linear scanner is used, oscillating the scanning mirror causes a dwell time in scanning amplitude border area, where the scanning mirror changes the direction of movement. This can cause excessive energy input to this area which in turn can cause vaporization and process instability. This process instability can be avoided by decreasing energy in this region by power modulation. Powder feeding parameters have a significant role in terms of process stability. It was determined that with certain powder feeding parameter combinations powder cloud behavior became unstable, due to the vaporizing powder material in powder cloud. Mainly this was noticed, when either or both the scanning frequency or powder feeding gas flow was low or steep powder feeding angle was used. When powder material vaporization occurred, it created vapor flow, which prevented powder material to reach the melt pool and thus dilution increased. Also powder material vaporization was noticed to produce emission of light at wavelength range of visible light. This emission intensity was noticed to be correlated with the amount of vaporization in the powder cloud.
Resumo:
Tämän sivuaineen tutkielman tarkoituksena on selvittää, miten suomalaiset ja italialaiset englannin kielen opiskelijat tunnistavat englanninkielisten idiomien merkityksiä. Erityisesti opiskelijoiden oman äidinkielen vaikutusta idiomien ymmärtämiseen tutkitaan, kuin myös idiomien eri ominaisuuksien vaikutusta. Lisäksi tutkitaan, miten opiskelijat itse ajattelevat osaavansa käyttää idiomeja, ja pitävätkö he idiomien oppimista tärkeänä. Tutkielmaan osallistui 35 suomalaista englannin kielen yliopisto-opiskelijaa ja 34 italialaista englannin kielen yliopisto-opiskelijaa. Tutkimusaineisto kerättiin monivalintakyselyn avulla. Idiomit valittiin Collins Cobuild Dictionary of Idioms (2001) -sanakirjasta. Kysely sisälsi 36 idiomia, jotka valittiin kolmesta eri frekvenssiluokasta. Jokaisesta frekvenssiluokasta valittiin neljä idiomia, joille oli vastine sekä suomen että italian kielessä, neljä idiomia, joille oli vastine vain suomen kielessä ja neljä idiomia, joille oli vastine vain italian kielessä. Kullekin idiomille oli annettu neljä merkitysvaihtoehtoa, ja näistä yksi tai kaksi oli sanakirjojen mukaisia oikeita vastauksia. Tutkimuksen tulokset näyttävät osoittavan, että sekä suomalaisilla että italialaisilla oli vaikeuksia idiomien merkitysten tunnistamisessa. Kuitenkin myös suomalaisten ja italiaisten välillä oli tilastollisesti merkittävä ero. Suomalaiset osasivat idiomit huomattavasti paremmin kuin italialaiset. Koehenkilöt ymmärsivät merkittävästi helpommin idiomit joille oli vastine heidän omassa äidinkielessään kuin idiomit joille ei ollut vastinetta. Lisäksi vastaajat näyttivät hyötyvän myös idiomien kuvainnollisen ja kirjaimellisen merkityksen läheisyydestä eli läpinäkyvyydestä. Idiomien frekvenssi sen sijaan ei näyttänyt vaikuttavan niiden ymmärtämiseen. Suomalaisten ja italialaisten englannin opiskelijoiden mukaan idiomien opiskelu on hyödyllistä ja tarpeellista. Tulokset osoittavat, että idiomien ymmärtäminen on haastavaa jopa edistyneille oppijoille. Omalla äidinkielellä näyttää olevan suuri vaikutus idiomien ymmärtämiseen, ja nimenomaan samankaltaisuudesta on hyötyä. Äidinkielen merkitykseen vieraiden kielten oppimisessa ja sanaston oppimisessa täytyisi kiinnittää enemmän huomiota, ja idiomeja sekä muuta kuvainnollista kieltä täytyisi opettaa myös edistyneemmille oppijoille.
Resumo:
Reactive arthritis (ReA) is an inflammatory joint disease, which belongs to the group of Spondyloarthritis (SpA). It may occur after infections with certain gram-negative bacteria such as Salmonella and Yersinia. SpAs are strongly associated with the human leucocyte antigen (HLA)-B27. Despite active research, the mechanism by which HLA-B27 causes disease susceptibility is still unknown. However, HLA-B27 has a tendency to misfold during assembly. It is possible that the misfolding of HLA-B27 could alter signaling pathways and/or molecules involved in inflammatory response in cells. We have earlier discovered that in HLA-B27-positive cells the interaction between the host and causative bacteria is disturbed. Our recent studies indicate that the expression of HLA-B27 may alter certain signaling molecules by disturbing their activation. The aim of this study was to investigate whether the expression of HLA-B27 disturbs the signaling molecules, especially the phosphorylation of transcription factor STAT1. STAT1 is an important mediator of inflammatory responses. Our results show that the phosphorylation of the STAT1 is significantly altered in HLA-B27-expressing U937 monocytic cells compared with control cells. STAT1 tyrosine 701 is more strongly phosphorylated in HLAB27- expressing cells; whereas the phosphorylation of STAT1 serine 727 is prolonged. Phosphorylation of STAT1 was discovered to be dependent on protein kinase PKR. Furthermore, we found out that the expression of posttranscriptional gene regulator HuR was altered in HLA-B27-expressing cells. We also detected that HLA-B27-positive cells secrete more interleukin 6, which is an important mediator of inflammation. These results help to understand how HLA-B27 may confer susceptibility to SpAs.
Resumo:
Nowadays global business trends force the adoption of innovative ICTs into the supply chain management (SCM). Particularly, the RFID technology is on high demand among SCM professionals due to its business advantages such as improving of accuracy and veloc-ity of SCM processes which lead to decrease of operational costs. Nevertheless, a question of the RFID technology impact on the efficiency of warehouse processes in the SCM re-mains open. The goal of the present study is to experiment the possibility of improvement order picking velocity in a warehouse of a big logistics company with the use of the RFID technology. In order to achieve this goal the following objectives have been developed: 1) Defining the scope of the RFID technology applications in the SCM; 2) Justification of the RFID technology impact on the SCM processes; 3) Defining a place of the warehouse order picking process in the SCM; 4) Identification and systematization of existing meth-ods of order picking velocity improvement; 5) Choosing of the study object and gathering of the empirical data about number of orders, number of hours spent per each order line daily during 5 months; 6) Processing and analysis of the empirical data; 7) Conclusion about the impact of the RFID technology on the speed of order picking process. As a result of the research it has been found that the speed of the order picking processes has not been changed as time has gone after the RFID adoption. It has been concluded that in order to achieve a positive effect in the speed of order picking process with the use of the RFID technology it is necessary to simultaneously implement changes in logistics and organizational management in 3PL logistics companies. Practical recommendations have been forwarded to the management of the company for further investigation and procedure.
Resumo:
The most common reason for a low-voltage induction motor breakdown is a bearing failure. Along with the increasing popularity of modern frequency converters, bearing failures have become the most important motor fault type. Conditions in which bearing currents are likely to occur are generated as a side effect of fast du/dt switching transients. Once present, different types of bearing currents can accelerate the mechanical wear of bearings by causing deformation of metal parts in the bearing and degradation of the lubricating oil properties.The bearing current phenomena are well known, and several bearing current measurement and mitigation methods have been proposed. Nevertheless, in order to develop more feasible methods to measure and mitigate bearing currents, better knowledge of the phenomena is required. When mechanical wear is caused by bearing currents, the resulting aging impact has to be monitored and dealt with. Moreover, because of the stepwise aging mechanism, periodically executed condition monitoring measurements have been found ineffective. Thus, there is a need for feasible bearing current measurement methods that can be applied in parallel with the normal operation of series production drive systems. In order to reach the objectives of feasibility and applicability, nonintrusive measurement methods are preferred. In this doctoral dissertation, the characteristics and conditions of bearings that are related to the occurrence of different kinds of bearing currents are studied. Further, the study introduces some nonintrusive radio-frequency-signal-based approaches to detect and measure parameters that are associated with the accelerated bearing wear caused by bearing currents.
Resumo:
A high-frequency cyclonverter acts as a direct ac-to-ac power converter circuit that does not require a diode bidge rectifier. Bridgeless topology makes it possible to remove forward voltage drop losses that are present in a diode bridge. In addition, the on-state losses can be reduced to 1.5 times the on-state resistance of switches in half-bridge operation of the cycloconverter. A high-frequency cycloconverter is reviewed and the charging effect of the dc-capacitors in ``back-to-back'' or synchronous mode operation operation is analyzed. In addition, a control method is introduced for regulating dc-voltage of the ac-side capacitors in synchronous operation mode. The controller regulates the dc-capacitors and prevents switches from reaching overvoltage level. This can be accomplished by variating phase-shift between the upper and the lower gate signals. By adding phase-shift between the gate signal pairs, the charge stored in the energy storage capacitors can be discharged through the resonant load and substantially, the output resonant current amplitude can be improved. The above goals are analyzed and illustrated with simulation. Theory is supported with practical measurements where the proposed control method is implemented in an FPGA device and tested with a high-frequency cycloconverter using super-junction power MOSFETs as switching devices.