46 resultados para GAUSSIAN GENERATOR FUNCTIONS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The question of the trainability of executive functions and the impact of such training on related cognitive skills has stirred considerable research interest. Despite a number of studies investigating this, the question has not yet been solved. The general aim of this thesis was to investigate two very different types of training of executive functions: laboratory-based computerized training (Studies I-III) and realworld training through bilingualism (Studies IV-V). Bilingualism as a kind of training of executive functions is based on the idea that managing two languages requires executive resources, and previous studies have suggested a bilingual advantage in executive functions. Three executive functions were studied in the present thesis: updating of working memory (WM) contents, inhibition of irrelevant information, and shifting between tasks and mental sets. Studies I-III investigated the effects of computer-based training of WM updating (Study I), inhibition (Study II), and set shifting (Study III) in healthy young adults. All studies showed increased performance on the trained task. More importantly, improvement on an untrained task tapping the trained executive function (near transfer) was seen in Study I and II. None of the three studies showed improvement on untrained tasks tapping some other cognitive function (far transfer) as a result of training. Study I also used PET to investigate the effects of WM updating training on a neurotransmitter closely linked to WM, namely dopamine. The PET results revealed increased striatal dopamine release during WM updating performance as a result of training. Study IV investigated the ability to inhibit task-irrelevant stimuli in bilinguals and monolinguals by using a dichotic listening task. The results showed that the bilinguals exceeded the monolinguals in inhibiting task-irrelevant information. Study V introduced a new, complementary research approach to study the bilingual executive advantage and its underlying mechanisms. To circumvent the methodological problems related to natural groups design, this approach focuses only on bilinguals and examines whether individual differences in bilingual behavior correlate with executive task performances. Using measures that tap the three above-entioned executive functions, the results suggested that more frequent language switching was associated with better set shifting skills, and earlier acquisition of the second language was related to better inhibition skills. In conclusion, the present behavioral results showed that computer-based training of executive functions can improve performance on the trained task and on closely related tasks, but does not yield a more general improvement of cognitive skills. Moreover, the functional neuroimaging results reveal that WM training modulates striatal dopaminergic function, speaking for training-induced neural plasticity in this important neurotransmitter system. With regard to bilingualism, the results provide further support to the idea that bilingualism can enhance executive functions. In addition, the new complementary research approach proposed here provides some clues as to which aspects of everyday bilingual behavior may be related to the advantage in executive functions in bilingual individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At present, permanent magnet synchronous generators (PMSGs) are of great interest. Since they do not have electrical excitation losses, the highly efficient, lightweight and compact PMSGs equipped with damper windings work perfectly when connected to a network. However, in island operation, the generator (or parallel generators) alone is responsible for the building up of the network and maintaining its voltage and reactive power level. Thus, in island operation, a PMSG faces very tight constraints, which are difficult to meet, because the flux produced by the permanent magnets (PMs) is constant and the voltage of the generator cannot be controlled. Traditional electrically excited synchronous generators (EESGs) can easily meet these constraints, because the field winding current is controllable. The main drawback of the conventional EESG is the relatively high excitation loss. This doctoral thesis presents a study of an alternative solution termed as a hybrid excitation synchronous generator (HESG). HESGs are a special class of electrical machines, where the total rotor current linkage is produced by the simultaneous action of two different excitation sources: the electrical and permanent magnet (PM) excitation. An overview of the existing HESGs is given. Several HESGs are introduced and compared with the conventional EESG from technical and economic points of view. In the study, the armature-reaction-compensated permanent magnet synchronous generator with alternated current linkages (ARC-PMSG with ACL) showed a better performance than the other options. Therefore, this machine type is studied in more detail. An electromagnetic design and a thermal analysis are presented. To verify the operation principle and the electromagnetic design, a down-sized prototype of 69 kVA apparent power was built. The experimental results are demonstrated and compared with the predicted ones. A prerequisite for an ARC-PMSG with ACL is an even number of pole pairs (p = 2, 4, 6, …) in the machine. Naturally, the HESG technology is not limited to even-pole-pair machines. However, the analysis of machines with p = 3, 5, 7, … becomes more complicated, especially if analytical tools are used, and is outside the scope of this thesis. The contribution of this study is to propose a solution where an ARC-PMSG replaces an EESG in electrical power generation while meeting all the requirements set for generators given for instance by ship classification societies, particularly as regards island operation. The maximum power level when applying the technology studied here is mainly limited by the economy of the machine. The larger the machine is, the smaller is the efficiency benefit. However, it seems that machines up to ten megawatts of power could benefit from the technology. However, in low-power applications, for instance in the 500 kW range, the efficiency increase can be significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maailmanlaajuinen ilmastopolitiikka asettaa vaativia tavoitteita hiilidioksidipäästöjen vähentämiselle. Suurin haaste on tuottaa energiaa mahdollisimman alhaisin kustannuksin käyttäen uusiutuvia ja ympäristöä säästäviä energiamuotoja. Tuulivoimasta on tullut nopeimmin kehittyvä sähköntuotantotapa, ja tuuliturbiinien koon kasvun myötä on myös generaattorien koko kasvanut merkittävästi 1990-luvulta lähtien. Generaattorin massiivisuus suoravetoisessa tuuliturbiinin voimansiirrossa vaatii tarkkoja kuormitustarkasteluja, jotta rakenne kestäisi tuuliturbiinin eliniän. Tuuliturbiinin kuormitukset ovat stokastisia ja toisinaan erittäin suuria, mikä vaikeuttaa kuormitusten määrittämistä. Tuulen kuormitusten lisäksi generaattori altistuu eri toimintojen kautta muillekin kuormituksille, ja tästä syystä on otettava huomioon jarrutuksen, dynaamisen tasapainon ja ohjauksen sekä verkkovikojen aiheuttamat rasitukset tuuliturbiinin voimansiirrolle. Edellisten lisäksi työssä on tarkasteltu erilaisia rakenneratkaisuja sekä pyritty kiinnittämään huomio niiden kuormankantokykyyn ja jäykkyyteen sekä generaattorin keventämismahdollisuuksiin verrattuna perinteisiin radiaalivuogeneraattoreihin. Työssä on pyritty selvittämään rakenteen kuormitukset siten, että pystyttäisiin optimoimaan mahdollisimman kevyt rakenne. Optimoinnin kohteena on pinnarakenteisen generaattorin rakenteen massa puolien, puolan kulmien sekä tukirenkaan ja niistä aiheutuvien erilaisten rakenneyhdistelmien suhteen tarkasteltuna.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resultaten påvisade små, men mätbara försämringar i minnes- och verbal förmåga hos personer som haft Parkinsons sjukdom under tre år. Jämfört med en kontrollgrupp uppvisade Parkinsonpatienter avvikande responser i hjärnans elektriska aktivitet under en korttidsminnesuppgift, och de presterade även sämre i olika typer av andra minnesuppgifter. Försämring i en specifik typ av minnesuppgift korrelerade med förminskad volym i höger hjärnhalva. Samband hittades också mellan sämre verbal förmåga och förminskad volym i djupa hjärnstrukturer. Förminskad hjärnvolym har tidigare påvisats hos dementa patienter i senare sjukdomsstadier. Forskningsresultaten bidrar med ny kunskap om kognitiva symptom och deras neurala bakgrund vid Parkinsons sjukdom. De tyder också på att tidig kognitiv funktionsnedsättning kan identifieras, vilket kan bidra till utvecklingen av sjukdomens behandling. Parkinsons sjukdom är den näst vanligaste neurogeriatriska sjukdomen efter Alzheimers sjukdom. Symptomen uppstår som följd av förminskad produktion av hjärnans transmittorämne dopamin. Parkinsons sjukdom har traditionellt betraktats som en progressiv motorisk sjukdom. Ny forskning tyder på att multipla hjärnsystem skadas, vilket resulterar i att även tankeprocesser påverkas. 75-80% uppskattas insjukna i demens 10-15 år efter diagnos, men det kognitiva sjukdomsförloppet och orsaken till demenssymptomen är tillsvidare okänd. I Finland uppskattas ca 10-12 000 personer ha Parkinsons sjukdom, varav ca 3 000 uppskattas ha demens. ----------------------------------------------------------------------------------------------------------------------------------------------------- Tutkimuksessa todettiin lieviä muutoksia muisti- ja kielellisissä toiminnoissa alle kolme vuotta sairastaneilla Parkinson-potilailla. Potilailla havaittiin poikkeavia aivosähkötoiminnan vasteita lyhytkestoista muistia mittaavan tehtävän aikana. Potilaat suoriutuivat myös verrokkiryhmää heikommin useissa muistitehtävissä. Heikentynyt tahaton muisti liittyi pienempään aivokuoren harmaan aineen paikalliseen tilavuuteen. Heikompi kielellinen suoriutuminen liittyi pienempään harmaan aineen tilavuuteen aivojen syvissä rakenteissa. Pienentyneitä aivorakenteiden tilavuuksia on aiemmin todettu dementoituneilla Parkinson-potilailla sairauden myöhemmissä vaiheissa. Tutkimustulokset tuovat uutta tietoa Parkinsonin taudin kognitiivisista oireista ja niiden aivoperäisestä taustasta. Tulosten perusteella on mahdollista tunnistaa jo varhaisia kognitiivisia muutoksia, mikä voi mahdollistaa tehokkaamman hoidon kohdentamisen. Parkinsonin tauti on Alzheimerin taudin jälkeen toiseksi yleisin neurogeriatrinen sairaus. Oirekuva liittyy aivojen dopaminergisen järjestelmän rappeutumiseen. Perinteisesti liikehäiriösairaudeksi luokiteltu sairaus vaurioittaa lukuisia muita aivojärjestelmiä aiheuttaen muutoksia myös mm. ajattelutoiminnoissa. Pitkään sairastaneista 75–80 prosentilla esiintyy dementiaoireita, mutta oireiden syy ja kehityskaari tunnetaan toistaiseksi huonosti. Suomessa on arviolta 10–12 000 Parkinson-potilasta, joista noin 3 000 arvioidaan kärsivän dementiaoireista.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main topic of the thesis is optimal stopping. This is treated in two research articles. In the first article we introduce a new approach to optimal stopping of general strong Markov processes. The approach is based on the representation of excessive functions as expected suprema. We present a variety of examples, in particular, the Novikov-Shiryaev problem for Lévy processes. In the second article on optimal stopping we focus on differentiability of excessive functions of diffusions and apply these results to study the validity of the principle of smooth fit. As an example we discuss optimal stopping of sticky Brownian motion. The third research article offers a survey like discussion on Appell polynomials. The crucial role of Appell polynomials in optimal stopping of Lévy processes was noticed by Novikov and Shiryaev. They described the optimal rule in a large class of problems via these polynomials. We exploit the probabilistic approach to Appell polynomials and show that many classical results are obtained with ease in this framework. In the fourth article we derive a new relationship between the generalized Bernoulli polynomials and the generalized Euler polynomials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A program for calculating low-speed low-power synchronous machine is presented. A permanent-magnet synchronous generator for 1 kW 150 rpm is designed. Optimization of magnet’s and coil’s dimensions was made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study will concentrate on Product Data Management (PDM) systems, and sheet metal design features and classification. In this thesis, PDM is seen as an individual system which handles all product-related data and information. The meaning of relevant data is to take the manufacturing process further with fewer errors. The features of sheet metals are giving more information and value to the designed models. The possibility of implementing PDM and sheet metal features recognition are the core of this study. Their integration should make the design process faster and manufacturing-friendly products easier to design. The triangulation method is the basis for this research. The sections of this triangle are: scientific literature review, interview using the Delphi method and the author’s experience and observations. The main key findings of this study are: (1) the area of focus in triangle (the triangle of three different point of views: business, information exchange and technical) depends on the person’s background and their role in the company, (2) the classification in the PDM system (and also in the CAD system) should be done using the materials, tools and machines that are in use in the company and (3) the design process has to be more effective because of the increase of industrial production, sheet metal blank production and the designer’s time spent on actual design and (4) because Design For Manufacture (DFM) integration can be done with CAD-programs, DFM integration with the PDM system should also be possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today’s electrical machine technology allows increasing the wind turbine output power by an order of magnitude from the technology that existed only ten years ago. However, it is sometimes argued that high-power direct-drive wind turbine generators will prove to be of limited practical importance because of their relatively large size and weight. The limited space for the generator in a wind turbine application together with the growing use of wind energy pose a challenge for the design engineers who are trying to increase torque without making the generator larger. When it comes to high torque density, the limiting factor in every electrical machine is heat, and if the electrical machine parts exceed their maximum allowable continuous operating temperature, even for a short time, they can suffer permanent damage. Therefore, highly efficient thermal design or cooling methods is needed. One of the promising solutions to enhance heat transfer performances of high-power, low-speed electrical machines is the direct cooling of the windings. This doctoral dissertation proposes a rotor-surface-magnet synchronous generator with a fractional slot nonoverlapping stator winding made of hollow conductors, through which liquid coolant can be passed directly during the application of current in order to increase the convective heat transfer capabilities and reduce the generator mass. This doctoral dissertation focuses on the electromagnetic design of a liquid-cooled direct-drive permanent-magnet synchronous generator (LC DD-PMSG) for a directdrive wind turbine application. The analytical calculation of the magnetic field distribution is carried out with the ambition of fast and accurate predicting of the main dimensions of the machine and especially the thickness of the permanent magnets; the generator electromagnetic parameters as well as the design optimization. The focus is on the generator design with a fractional slot non-overlapping winding placed into open stator slots. This is an a priori selection to guarantee easy manufacturing of the LC winding. A thermal analysis of the LC DD-PMSG based on a lumped parameter thermal model takes place with the ambition of evaluating the generator thermal performance. The thermal model was adapted to take into account the uneven copper loss distribution resulting from the skin effect as well as the effect of temperature on the copper winding resistance and the thermophysical properties of the coolant. The developed lumpedparameter thermal model and the analytical calculation of the magnetic field distribution can both be integrated with the presented algorithm to optimize an LC DD-PMSG design. Based on an instrumented small prototype with liquid-cooled tooth-coils, the following targets have been achieved: experimental determination of the performance of the direct liquid cooling of the stator winding and validating the temperatures predicted by an analytical thermal model; proving the feasibility of manufacturing the liquid-cooled tooth-coil winding; moreover, demonstration of the objectives of the project to potential customers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High magnetic fields and extremely low temperatures are essential in the study of new semiconductor materials for example in the field of spintronics. Typical phenomenons that arise in such conditions are: Hall Effect, Anomalous Hall effect and Shubnikov de-Haas effect. In this thesis a device capable for such conditions was described. A strong magnetic field pulse generator situated in the laboratory of physics and the Lappeenranta University of Technology was studied. The device is introduced in three parts. First one is the pulsed field magnetic generator, which is responsible for generating the high magnetic field. Next one is the measurement systems, which are responsible for monitoring the sample and the system itself. The last part describes the cryostat system, which allows the extremely cold temperatures in the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Professional services are an increasingly important group of economy and related to them there has been identified a fairly new concept called professional service operations management. However professional service operations management is still quite under-researched area which needs further research especially in specific contexts. This study aims to respond to that need by examining courts as an environment for operations management. As a result there is a preliminary structured description of what operations management is and could be in courts. The study also aims to inspire and tentatively classify possible areas for future research. Courts are examined based on three common perspectives for typical characteristics of professional services which can be identified in literature: the nature of customer role, the nature of professional work and the nature of process and product. The examination is based on research data from several research projects conducted in Finland and other European countries. Based on the examination it can be said that the operational environment of courts is highly complex and demanding because the case as an object of operations management tasks is challenging, the process sets strict requirements to the handling of the cases and the workforce is hard to direct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis: A liquid-cooled, direct-drive, permanent-magnet, synchronous generator with helical, double-layer, non-overlapping windings formed from a copper conductor with a coaxial internal coolant conduit offers an excellent combination of attributes to reliably provide economic wind power for the coming generation of wind turbines with power ratings between 5 and 20MW. A generator based on the liquid-cooled architecture proposed here will be reliable and cost effective. Its smaller size and mass will reduce build, transport, and installation costs. Summary: Converting wind energy into electricity and transmitting it to an electrical power grid to supply consumers is a relatively new and rapidly developing method of electricity generation. In the most recent decade, the increase in wind energy’s share of overall energy production has been remarkable. Thousands of land-based and offshore wind turbines have been commissioned around the globe, and thousands more are being planned. The technologies have evolved rapidly and are continuing to evolve, and wind turbine sizes and power ratings are continually increasing. Many of the newer wind turbine designs feature drivetrains based on Direct-Drive, Permanent-Magnet, Synchronous Generators (DD-PMSGs). Being low-speed high-torque machines, the diameters of air-cooled DD-PMSGs become very large to generate higher levels of power. The largest direct-drive wind turbine generator in operation today, rated just below 8MW, is 12m in diameter and approximately 220 tonne. To generate higher powers, traditional DD-PMSGs would need to become extraordinarily large. A 15MW air-cooled direct-drive generator would be of colossal size and tremendous mass and no longer economically viable. One alternative to increasing diameter is instead to increase torque density. In a permanent magnet machine, this is best done by increasing the linear current density of the stator windings. However, greater linear current density results in more Joule heating, and the additional heat cannot be removed practically using a traditional air-cooling approach. Direct liquid cooling is more effective, and when applied directly to the stator windings, higher linear current densities can be sustained leading to substantial increases in torque density. The higher torque density, in turn, makes possible significant reductions in DD-PMSG size. Over the past five years, a multidisciplinary team of researchers has applied a holistic approach to explore the application of liquid cooling to permanent-magnet wind turbine generator design. The approach has considered wind energy markets and the economics of wind power, system reliability, electromagnetic behaviors and design, thermal design and performance, mechanical architecture and behaviors, and the performance modeling of installed wind turbines. This dissertation is based on seven publications that chronicle the work. The primary outcomes are the proposal of a novel generator architecture, a multidisciplinary set of analyses to predict the behaviors, and experimentation to demonstrate some of the key principles and validate the analyses. The proposed generator concept is a direct-drive, surface-magnet, synchronous generator with fractional-slot, duplex-helical, double-layer, non-overlapping windings formed from a copper conductor with a coaxial internal coolant conduit to accommodate liquid coolant flow. The novel liquid-cooling architecture is referred to as LC DD-PMSG. The first of the seven publications summarized in this dissertation discusses the technological and economic benefits and limitations of DD-PMSGs as applied to wind energy. The second publication addresses the long-term reliability of the proposed LC DD-PMSG design. Publication 3 examines the machine’s electromagnetic design, and Publication 4 introduces an optimization tool developed to quickly define basic machine parameters. The static and harmonic behaviors of the stator and rotor wheel structures are the subject of Publication 5. And finally, Publications 6 and 7 examine steady-state and transient thermal behaviors. There have been a number of ancillary concrete outcomes associated with the work including the following. X Intellectual Property (IP) for direct liquid cooling of stator windings via an embedded coaxial coolant conduit, IP for a lightweight wheel structure for lowspeed, high-torque electrical machinery, and IP for numerous other details of the LC DD-PMSG design X Analytical demonstrations of the equivalent reliability of the LC DD-PMSG; validated electromagnetic, thermal, structural, and dynamic prediction models; and an analytical demonstration of the superior partial load efficiency and annual energy output of an LC DD-PMSG design X A set of LC DD-PMSG design guidelines and an analytical tool to establish optimal geometries quickly and early on X Proposed 8 MW LC DD-PMSG concepts for both inner and outer rotor configurations Furthermore, three technologies introduced could be relevant across a broader spectrum of applications. 1) The cost optimization methodology developed as part of this work could be further improved to produce a simple tool to establish base geometries for various electromagnetic machine types. 2) The layered sheet-steel element construction technology used for the LC DD-PMSG stator and rotor wheel structures has potential for a wide range of applications. And finally, 3) the direct liquid-cooling technology could be beneficial in higher speed electromotive applications such as vehicular electric drives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wind is one of the most compelling forms of indirect solar energy. Available now, the conversion of wind power into electricity is and will continue to be an important element of energy self-sufficiency planning. This paper is one in a series intended to report on the development of a new type of generator for wind energy; a compact, high-power, direct-drive permanent magnet synchronous generator (DD-PMSG) that uses direct liquid cooling (LC) of the stator windings to manage Joule heating losses. The main param-eters of the subject LC DD-PMSG are 8 MW, 3.3 kV, and 11 Hz. The stator winding is cooled directly by deionized water, which flows through the continuous hollow conductor of each stator tooth-coil winding. The design of the machine is to a large degree subordinate to the use of these solid-copper tooth-coils. Both steady-state and timedependent temperature distributions for LC DD-PMSG were examined with calculations based on a lumpedparameter thermal model, which makes it possible to account for uneven heat loss distribution in the stator conductors and the conductor cooling system. Transient calculations reveal the copper winding temperature distribution for an example duty cycle during variable-speed wind turbine operation. The cooling performance of the liquid cooled tooth-coil design was predicted via finite element analysis. An instrumented cooling loop featuring a pair of LC tooth-coils embedded in a lamination stack was built and laboratory tested to verify the analytical model. Predicted and measured results were in agreement, confirming the predicted satisfactory operation of the LC DD-PMSG cooling technology approach as a whole.