68 resultados para short circuit


Relevância:

60.00% 60.00%

Publicador:

Resumo:

All over the world power systems become bigger and bigger every day. New equipment is installed, new feeders are constructed, new power units are installed. Some old elements of the network, however, are not changed in time. As a result, “bottlenecks” for capacity transmission can occur. By locked power problem the situation when a power plant has installed capacity exceeding the power it can actually deliver is usually meant. Regime, scheme or even technical restrictions-related issues usually cause this kind of problem. It is really important, since from the regime point of view it is typical decision to have a mobile capacity reserve, in case of malfunctions. And, what can be even more significant, power plant owner (JSC Fortum in our case) losses his money because of selling less electrical energy. The goal of master`s thesis is to analyze the current state of Chelyabinsk power system and the CHP-3 (Combined Heat and Power plant) in particular in relation with it`s ability to deliver the whole capacity of the CHP in it`s existing state and also taking into consideration the prospect of power unit 3 installation by the fourth quarter of 2010. The thesis contains some general information about the UPS of Russia, CPS of Ural, power system of Chelyabinsk and the Chelyabinsk region itself. Then the CHP-3 is described from technical point of view with it`s equipment observation. Regimes for the nowadays power system and for the system after the power unit 3 installation are reviewed. The problems occurring are described and, finally, a solution is offered.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Työssä tutkitaan, kuinka pitkää moottorikaapelia on jännitevälipiiritaajuusmuuttajan kanssa mahdollista käyttää niin, että määritellyt reunaehdot vielä toteutuvat. Tavoitteena on tuottaa tietoa myynnille, markkinoinnille, tuotehallinnalle sekä tuoteylläpidolle siitä, miten taajuus-muuttaja toimii pidemmillä moottorikaapeleilla kuin valmistaja suosittelee. Tutkitut moottori-kaapelipituudet olivat 175…1025 metriä ja tutkitut laitteet nimellislähtövirroiltaan 2,4...25 A. Työssä aihetta käsitellään jänniteheijastusten näkökulmasta. Lisäksi tutkitaan moottorikaapelin pituuden vaikutusta taajuusmuuttajan eri komponenttien lämpenemiseen. Taajuusmuuttajan toiminnallisuutta arvioidaan moottorin suunnanvaihtojen avulla sekä turvallista toimintaa oikosulkutestein. Tutkittujen taajuusmuuttajien kohdalla on mahdollista käyttää taajuusmuuttajavalmistajan suositusta pidempiä moottorikaapeleita. Moottoriliittimien ylijännitteitä aiheuttavat jännite-heijastukset eivät aiheuttaneet raja-arvoja ylittäviä huippujännitteitä tutkituilla laitekokoon-panoilla. Myös lämpötilannousu oli maltillista tai jopa vähäistä taajuusmuuttajasta mitatuilla komponenteilla. Moottorisäätö havaittiin toimintakykyiseksi pidemmilläkin moottorikaape-leilla, tosin moottorin vääntömomentti heikkeni moottorikaapelien pituutta kasvatettaessa. Virranmittaus toimi hyvin myös pitkillä kaapeleilla, tuottaen vikalaukaisun kaikissa tehdyissä oikosulkutilanteissa. Moottorin ja taajuusmuuttajan melutaso nousivat moottorikaapelien pi-tuutta kasvatettaessa, vaikkakin moottorin käynti oli tasaista ja katkotonta Moottorikaapelin pituutta voidaan kasvattaa 325 metriin kaikissa tutkituissa laitteissa ilman, että mikään tutkittu ominaisuus vielä olennaisesti heikkenisi. Vielä 525 metrin moottorikaape-leita on mahdollista käyttää, mutta tällöin vääntömomentin tuotto on jo heikompaa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Increasingly growing share of distributed generation in the whole electrical power system’s generating system is currently a worldwide tendency, driven by several factors, encircling mainly difficulties in refinement of megalopolises’ distribution networks and its maintenance; widening environmental concerns adding to both energy efficiency approaches and installation of renewable sources based generation, inherently distributed; increased power quality and reliability needs; progress in IT field, making implementable harmonization of needs and interests of different-energy-type generators and consumers. At this stage, the volume, formed by system-interconnected distributed generation facilities, have reached the level of causing broad impact toward system operation under emergency and post-emergency conditions in several EU countries, thus previously implementable approach of their preliminary tripping in case of a fault, preventing generating equipment damage and disoperation of relay protection and automation, is not applicable any more. Adding to the preceding, withstand capability and transient electromechanical stability of generating technologies, interconnecting in proximity of load nodes, enhanced significantly since the moment Low Voltage Ride-Through regulations, followed by techniques, were introduced in Grid Codes. Both aspects leads to relay protection and auto-reclosing operation in presence of distributed generation generally connected after grid planning and construction phases. This paper proposes solutions to the emerging need to ensure correct operation of the equipment in question with least possible grid refinements, distinctively for every type of distributed generation technology achieved its technical maturity to date and network’s protection. New generating technologies are equivalented from the perspective of representation in calculation of initial steady-state short-circuit current used to dimension current-sensing relay protection, and widely adopted short-circuit calculation practices, as IEC 60909 and VDE 0102. The phenomenon of unintentional islanding, influencing auto-reclosing, is addressed, and protection schemes used to eliminate an sustained island are listed and characterized by reliability and implementation related factors, whereas also forming a crucial aspect of realization of the proposed protection operation relieving measures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Power line modelling has become an interesting research area in recent years as a result of advances in the power line distribution network system. Extensive knowledge about the power line cable characteristics can be implemented in a software algorithm in a modern broadband power-line communication modem. In this study, a novel approach for modelling power line cables (AMCMK) based on the broadband impedance spectroscopy (BIS) and transmission line matrix (TLM) techniques is recommended in characterizing a healthy cable and the various faults associated with low-voltage cables for both open and short circuit situation. Models for different cable conditions are developed and tuned, which include six models for both healthy and faulty cables situations. The models are on the basis of impedance response analysis of the cable. The resulting spectra from the simulations are also cross-correlated to determine the degree of similarities between the healthy cable spectra and their respective faulty spectra.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tämä työ on tehty Lappeenrannan teknilliselle yliopistolle, joka on suunnitellut ja toteuttanut hybridibussin. Hybridibussin ajomoottorissa käytetään kaksoiskäämitystä, joka mahdollistaa bussin ajamisen vikatilanteessa, jossa toinen käämityksistä on epäkunnossa. Työn tavoitteena on selvittää, millainen kaksoiskäämitys toimii parhaiten tämän hybridibussin kestomagneettiajomoottorissa. Työssä tutustutaan ajomoottoreihin ja niiltä vaadittaviin ominaisuuksiin sekä vikasietoisiin sähkömoottoreihin. Tutkimuksessa löydettyihin vikasietoisiin ajomoottoreihin perustuen päädyttiin neljään kaksoiskäämitysvaihtoehtoon. Näitä kaksoiskäämityksiä tutkittiin FE-analyysiä hyödyntäen. Kaksoiskäämitysten toimintaa simuloitiin nimellis- ja vikatilanteessa. Simuloinnin tuloksista selvisi, että kaksoiskäämitys, jossa jokaisessa urassa oli puolet yhtä käämitystä ja puolet toista (kaksoiskäämitys 1), ei toiminut kunnolla nimellistilanteessa eikä vikatilanteessa. Suurin ongelma oli vikatilanteessa aiheutuva suuri oikosulkuvirta. Kaksoiskäämitys, jossa kaksi napaa oli samaa käämitystä (kaksoiskäämitys 2), toimi moitteettomasti nimellistilanteessa. Vikatilanteen toiminnassa kuitenkin havaittiin epäjaksollisuutta magneettivuontiheydessä, mikä on haitallista moottorin käynnille ja vaaraksi roottorille. Kaksoiskäämityksiä, joista ensimmäisessä oli neljäsosa konetta samaa käämitystä (kaksoiskäämitys 3) ja toisessa puolet koneesta samaa käämitystä (kaksoiskäämitys 4), tutkittiin vikatilanteessa vain magneettivuontiheyden osalta. Puolet ja puolet käämityn koneen osalta magneettivuontiheys osottautui epäjaksolliseksi kuten oli odotettu. Neljäsosiksi käämityn koneen magneettivuontiheys oli säännöllisen jaksollinen. Nimellispisteessä kaksoiskäämityksillä 3 ja 4 havaittiin suuri vääntöväre verrattuna kaksoiskäämityksiin 1 ja 2. Johtopäätöksenä kaksoiskäämitys 3 vaikuttaa lupaavalta, mikäli suuri nimellispisteen vääntöväre saadaan hallintaan käyttämällä uravinoutta staattorissa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Eräiden ympäristövirikkeiden saatavuuden estämisen välittömät vaikutukset tarhaminkin käyttäytymiseen

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Thesis gives a decision support framework that has significant impact on the economic performance and viability of a hydropower company. The studyaddresses the short-term hydropower planning problem in the Nordic deregulated electricity market. The basics of the Nordic electricity market, trading mechanisms, hydropower system characteristics and production planning are presented in the Thesis. The related modelling theory and optimization methods are covered aswell. The Thesis provides a mixed integer linear programming model applied in asuccessive linearization method for optimal bidding and scheduling decisions inthe hydropower system operation within short-term horizon. A scenario based deterministic approach is exploited for modelling uncertainty in market price and inflow. The Thesis proposes a calibration framework to examine the physical accuracy and economic optimality of the decisions suggested by the model. A calibration example is provided with data from a real hydropower system using a commercial modelling application with the mixed integer linear programming solver CPLEX.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämä diplomityö tarkastelee TETRA-verkon soveltuvuutta turvallisuusviranomaisille tarkoitettuun telemetriasovellukseen, jossa erilaiset mittausdatat ja hälytystiedot kulkevat verkon yli SDS-viestiliikenteenä. Diplomityön tarkoituksena on tehdä kaksi sulautettua ohjelmistoa sekä yksi PCohjelmisto, joita käytetään rakennettavassa demolaitteistossa. Lisäksi selvitetään TETRA-verkon toimivuus ja rajoitukset sovelluksessa eri olosuhteissa ja eri kuormitustilanteissa. Diplomityön teoriaosassa käydään läpi työn määrittely ja ohjelmistonkehitysprosessin läpivienti eri osa-alueilla. Loppuosassa kuvataan tehdyt ohjelmistot erikseen ja yhdessä suunnittelusta toteutukseen, sekä lopullisen järjestelmän testaus.