30 resultados para chirp rate
Resumo:
APROS (Advanced Process Simulation Environment) is a computer simulation program developed to simulate thermal hydraulic processes in nuclear and conventional power plants. Earlier research at VTT Technological Research Centre of Finland had found the current version of APROS to produce inaccurate simulation results for a certain case of loop seal clearing. The objective of this Master’s thesis is to find and implement an alternative method for calculating the rate of stratification in APROS, which was found to be the reason for the inaccuracies. Brief literature study was performed and a promising candidate for the new method was found. The new method was implemented into APROS and tested against experiments and simulations from two test facilities and the current version of APROS. Simulation results with the new version were partially conflicting; in some cases the new method was more accurate than the current version, in some the current method was better. Overall, the new method can be assessed as an improvement.
Resumo:
Gasification offers an environmentally friendly alternative for conventional combustion enabling the use of low grade and troublesome fuel such as municipal waste. While combustion converts fuel directly into thermal energy and noxious gases, gasification thermally converts fuel into gas that can be used in multiple applications. The purpose of this work is to get to know the gasification as a phenomenon and examine the kinetics of gasification. The main interest is in the reaction rates of the most important gasification reactions - water-gas, Boudouard and shift reaction. Reaction rate correlations found in the scientific articles are examined in atmospheric pressure in different temperatures.
Resumo:
Reliable detection of intrapartum fetal acidosis is crucial for preventing morbidity. Hypoxia-related changes of fetal heart rate variability (FHRV) are controlled by the autonomic nervous system. Subtle changes in FHRV that cannot be identified by inspection can be detected and quantified by power spectral analysis. Sympathetic activity relates to low-frequency FHRV and parasympathetic activity to both low- and high-frequency FHRV. The aim was to study whether intra partum fetal acidosis can be detected by analyzing spectral powers of FHRV, and whether spectral powers associate with hypoxia-induced changes in the fetal electrocardiogram and with the pH of fetal blood samples taken intrapartum. The FHRV of 817 R-R interval recordings, collected as a part of European multicenter studies, were analyzed. Acidosis was defined as cord pH ≤ 7.05 or scalp pH ≤ 7.20, and metabolic acidosis as cord pH ≤ 7.05 and base deficit ≥ 12 mmol/l. Intrapartum hypoxia increased the spectral powers of FHRV. As fetal acidosis deepened, FHRV decreased: fetuses with significant birth acidosis had, after an initial increase, a drop in spectral powers near delivery, suggesting a breakdown of fetal compensation. Furthermore, a change in excess of 30% of the low-to-high frequency ratio of FHRV was associated with fetal metabolic acidosis. The results suggest that a decrease in the spectral powers of FHRV signals concern for fetal wellbeing. A single measure alone cannot be used to reveal fetal hypoxia since the spectral powers vary widely intra-individually. With technical developments, continuous assessment of intra-individual changes in spectral powers of FHRV might aid in the detection of fetal compromise due to hypoxia.
Resumo:
Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.
Resumo:
This thesis examines the impact of foreign exchange rate volatility to the extent of use of foreign currency derivatives. Especially the focus is on the impacts of 2008 global financial crisis. The crisis increased risk level in the capital markets greatly. The change in the currency derivatives use is analyzed by comparing means between different periods and in addition, by linear regression that enables to analyze the explanatory power of the model. The research data consists of financial statements figures from fiscal years 2006-2011 published by firms operating in traditional Finnish industrial sectors. Volatilities of the chosen three currency pairs is calculated from the daily fixing rates of ECB. Based on the volatility the sample period is divided into three sub-periods. The results suggest that increased FX market volatility did not increase the use foreign currency derivatives. Furthermore, the increased foreign exchange rate volatility did not increase the power of linear regression model to estimate the use foreign currency derivatives compared to previous studies.
Resumo:
Background: The function of the autonomic nervous system (ANS) can be evaluated with heart rate variability (HRV). Decreased HRV is associated with aging, the male sex, increased heart rate, and overall increased cardiometabolic risk. It has been hypothesized that early atherosclerotic vascular changes and ANS function are related. Aims: The aims were to assess reference values on HRV in young adults, and examine associations with HRV and cardiometabolic risk factors and metabolic syndrome (MetS) and to study relations between HRV and ultrasonographically measured vascular properties. Participants and methods: The present thesis is part of the Cardiovascular Risk in Young Finns Study. The thesis is based on the follow-up study in 2001, when the study individuals were 24-39 years of age. HRV data were available on 1 956 individuals. Results: HRV was inversely associated with age and heart rate (for all p<0.001). Highfrequency HRV (HF) was higher, and low-frequency HRV (LF) lower in women than men (p<0.0001 for both). MetS was associated with 11% decreased HF and 12% increased LF/HF-ratio in women, and 8% decreased HF and 4% increased LF/HF-ratio in men. Carotid artery distensibility was independently associated with HF and total HRV (for both p<0.05). Conclusions: The reference values in young adults were generated. Decreased HRV was associated with age, the male sex and increased heart rate. Women had higher HF and lower LF variability than men. MetS was related to decrease in HRV. The observed associations between carotid elasticity and HRV, supports the hypothesis that reduction in carotid elasticity may lead to decrease in autonomic cardiac control.
Resumo:
Fluid handling systems such as pump and fan systems are found to have a significant potential for energy efficiency improvements. To deliver the energy saving potential, there is a need for easily implementable methods to monitor the system output. This is because information is needed to identify inefficient operation of the fluid handling system and to control the output of the pumping system according to process needs. Model-based pump or fan monitoring methods implemented in variable speed drives have proven to be able to give information on the system output without additional metering; however, the current model-based methods may not be usable or sufficiently accurate in the whole operation range of the fluid handling device. To apply model-based system monitoring in a wider selection of systems and to improve the accuracy of the monitoring, this paper proposes a new method for pump and fan output monitoring with variable-speed drives. The method uses a combination of already known operating point estimation methods. Laboratory measurements are used to verify the benefits and applicability of the improved estimation method, and the new method is compared with five previously introduced model-based estimation methods. According to the laboratory measurements, the new estimation method is the most accurate and reliable of the model-based estimation methods.
Resumo:
The impact of ventricular rate (VR) on the outcome of electrical cardioversion (ECV) of acute atrial fibrillation (AF) is currently unknown. We aimed to determine the effect of VR during acute AF on the success of ECV, recurrence of AF and occurrence of post-cardioversion complications in 30 days follow-up. All ECVs performed in patients with acute atrial fibrillation lasting <48 hours in 2 Finnish university hospitals during 2003-2010 and 1 central hospital during 2010 were retrospectively identified. A total of 6,624 ECVs were performed in 2,821 consecutive patients. VR≤60 BPM was defined low and VR≥160 BPM high. The median VR before ECV was 109 BPM. The success rate of ECV was 94.2%. Bradycardia occurred in 62 (0.9%) and thromboembolic complications in 39 (0.6%) ECVs. Low VR was observed before 75 (1.1%) ECVs and male sex was its only independent predictor. High VR was observed in 165 (2.5%) ECVs. The independent predictors of high VR were younger age, <12 h episode duration, no previous history of AF and alcohol abuse. Low or high VR were not related to the success of ECV, incidence of thromboembolic or bradycardic complications, or recurrence of AF, although VR was significantly (p<0.001) lower in the patients in whom AF recurred. In conclusion, ECV of acute AF is an effective procedure and VR during AF does not affect its efficacy, the maintenance of sinus rhythm or the incidence of bradycardic, thromboembolic or other complications during 30 days follow-up after ECV. Low VR is predominately observed in male patients, while high VR was a feature related to a shorter history of AF and high alcohol-intake.