30 resultados para Ultraviolet light


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incidence of nonmelanoma skin cancer (NMSC) is increasing. Ultraviolet (UV) –light is a major risk factor for the development of cutaneous SCC. Cutaneous SCCs that develop to chronic ulcers are known to progress and metastasize more easily than UV-induced SCCs. Matrix metalloproteinases (MMPs) are a group of proteolytic enzymes which are suggested to have a role in cancer growth and invasion. The molecular background for progression of cutaneous SCC was examined by immunohistochemistry (IHC) using tissue samples of recessive dystrophic epidermolysis bullosa (RDEB) –associated SCC, sporadic UV-induced SCC, and SCC precursors. IHC studies using tissue microarray (TMA) technique revealed overexpression of MMP-7 and MMP-13 in SCC tumor cells. MMP-7 expression was enhanced especially in the SCC tumor cells of the RDEB –associated SCCs. Studies with SCC cell lines showed that tumor cell derived MMP-7 activated heparin binding epidermal growth factor –like growth factor (HB-EGF) which enhanced the growth of SCC tumor cells. Further, it was shown that type VII collagen (COL7) is expressed in sporadic SCC tumor cells. Interestingly, it was shown that SCC –associated MMP-13 is capable of cleaving COL7 in vitro. COL7 cleavage may have a role in the progression of cutaneous SCC. Studies on serine proteinase inhibitor gene family using SCC tumor cell gene array, quantitative real-time PCR, SCC cell lines, normal human epidermal keratinocytes and IHC of TMA samples showed that serine proteinase inhibitor clade A, member 1 (serpinA1, alpha-1-antitrypsin) is expressed and produced by human SCC tumor cells but not by normal keratinocytes. Moreover, serpinA1 expression was shown to correlate with the progression of cutaneous SCC using transformed HaCaT-cell lines and mouse chemically induced skin SCC model. SerpinA1 may serve as a novel biomarker for the progression of cutaneous SCC. This study elucidated putative mechanisms of the progression of cutaneous SCC and revealed novel biomarker candidates for the progression of SCC of the skin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this investigation was to evaluate the possibility to enhance certain qualities of facial prostheses. Polymethyl methacrylate is still being used as base mate¬rial or clip carrier material, but it is hard and heavy, and debonding of the silicone from the acrylic base material is a frequent problem. This thesis aims to evaluate the use of fiber-reinforced composite (FRC) as framework material for maxillofacial silicone prostheses. FRC has been used as reinforcement in removable and fixed partial dentures since the 1990s. This material is lightweight and can be fabricated to compress the margins of the prosthesis slightly, to keep it tightly against the skin during jaw movements and facial expressions. Additionally, the use of a thermochromic pigment, colorless in room temperature and red in a cold environment, was studied in order to evaluate the possibility of using this color changing pigment in facial prostheses to mimic the color change of facial skin in cold weather. The tensile bond strength between pre-impregnated, unidirectional FRC and maxillofacial silicone elastomer was studied. Three different bonding agents or primers were compared. Bond strength was improved by one of the primers and by roughening the surface. The effect of a skin compressing glass fiber-reinforced composite framework on facial skin blood flow was studied by using a face mask, constructed with a compression pad corresponding to the outer margin of a glass fiber-reinforced framework beam of a facial prosthesis. The skin blood flow of ten healthy volunteers, aged 23-25 years, was measured during touch, light, and moderate compression of the skin, by using laser Doppler imaging technique. None of the compressions showed any marked effects on local skin blood flow. There were no significant differences between blood flow during compression and at baseline. Maxillofacial silicone elastomer was colored intrinsically with conventional color pigments: a control group containing only conventional pigments was compared to two test groups with 0.2 wt% and 0.6 wt% thermochromic pigment added. The color of the material was measured with a spectrophotometer in room temperature and after storage in a freezer. The color stability of the maxillofacial silicone elastomer colored with thermo¬chromic pigment was evaluated by artificial aging. The color dif¬ference of the L* (lightness) and a* values (redness), comparing color after the samples were stored at room temperature and in a freezer (-19°C), was statistically significant for both 0.2 wt% and 0.6 wt% thermo¬chromic pigment groups. The differences in the b* values (yellowness) were statistically significant for the 0.6 wt% group. Exposure to ultraviolet (UV) radiation led to visually noticeable and statistically signifi¬cant color changes (ΔE) in all color values in both test groups. The specimens containing thermochromic pigment were very sensitive to UV radiation. In conclusion, a framework of fiber-reinforced composite can successfully be bonded to maxillofacial silicone elastomer, and a framework beam, compressing the facial skin, did not remarkably alter the skin blood flow on healthy, young adults. The thermochromic pigment showed color change in maxillofacial silicone elastomer. However, artificial aging showed that it was too sensitive to UV radiation to be used, as such, in maxillofacial prostheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Veden riittämätön puhdistus aiheuttaa riskin veden käyttäjille. Miljoonia kuolemia vuosittain aiheuttavien vesiteitse leviävien sairauksien ehkäisemiseksi vaaditaan tehokkaita juomaveden desinfiointimenetelmiä. Kuivuuden ja väestönkasvun myötä veden tarve on lisääntynyt ja vedenkulutus tulee yhä kasvamaan. Tästä syystä mahdollisuus kierrättää vettä hyödyntäen sitä esimerkiksi kasteluun on saanut yhä enemmän huomiota. Kierrätettävä vesi on kuitenkin käsiteltävä huolellisesti sen sisältämän mikrobiologisen kontaminaatioriskin vuoksi. Ultraviolettisäteily luokitellaan fysikaaliseksi desinfiointimenetelmäksi. Sen tehokkuus perustuu mikro-organismien absorboimaan UV-säteilyyn, jonka aiheuttamien DNA:ssa tai RNA:ssa tapahtuvien muutoksien seurauksena mikro-organismi inaktivoituu ja estyy lisääntymästä. UV-desinfioinnissa on tyypillisesti käytetty elohopeahöyrylamppuja. Vaihtoehtoinen UV-säteilyn lähde ovat LEDit eli valoa emittoivat diodit. Matalapaine-elohopeahöyrylamppujen emittoima säteily on aallonpituudella 254 nm ja keskipaine-elohopeahöyrylamppujen emittoima säteily on laajakaistaista säteilyä. Energiatehokkuuden lisäksi LEDien etuna on, että niillä voidaan tuottaa kapeakaista säteilyä aallonpituudella, joka parhaiten absorboituu DNA:han. Tämän diplomityön tarkoituksena oli tutkia, onko UVC-alueen aallonpituuksien yhdistelmillä synergistisiä etuja LEDien desinfiointitehokkuuteen, kun desinfioidaan virtaavaa vettä useilla säteilyannoksilla ja indikaattorimikrobina käytetään kolibakteeria. Tavoitteena oli myös tutkia tällä hetkellä saatavissa olevien LEDien desinfiointitehokkuutta energiatehokkuuden näkökulmasta. Yksittäisistä aallonpituuksista desinfiointitehokkuudeltaan parhaimmaksi osoittautui 260 nm, aallonpituuksien yhdistelmistä tehokkain oli 265 nm:n ja 260 nm:n yhdistelmä. Muilla aallonpituuksien yhdistelmillä ei saavutettu odotettua parempaa desinfiointitehokkuutta. Optiselta teholtaan parhaimmat LEDit, 265 nm, 270 nm ja 275 nm olivat kokeiden perusteella myös energiatehokkuuden kannalta tarkasteltuina parhaimmat sekä yksittäin että yhdistelminä. UVC-aallonpituuksia emittoivien LEDien optisen tehokkuuden paraneminen on edellytys LEDien hyödyntämiselle desinfioinnissa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kansalliskirjaston ONKI-projektin ylläpitämä Finto-palvelu käyttää projektissa kehitettävää Skosmos-ohjelmaa (entinen ONKI Light). Skosmos on työkalu kontrolloitujen sanastojen, kuten asiasanastojen ja asiasanastotyyppisesti käytettävien ontologioiden julkaisuun. Työkalu tarjoaa selailu- ja hakukäyttöliittymän sanastoille sekä avoimet rajapinnat koneellista käyttöä varten. Käyttöliittymä on monikielinen sisältäen tällä hetkellä suomen-, ruotsin- sekä englanninkieliset käyttöliittymäversiot.

Skosmoksen edeltäjälle ONKI Lightille on tehty ONKI-projektissa jo aikaisempi käytettävyystesti, jonka raportti on luettavissa Doriassa.

Käytettävyystestien perusteella vaikuttaisi siltä, että ontologian selaamiseen asiasanoituksessa vaikuttaisi ainakin käyttäjän käyttämä järjestelmä, asiasanoitukseen käytettävä aika, asiasanoitustottumukset ja -kokemus sekä sanaston tuttuus. Jos aikaa ei ole juurikaan varattu asiasanoitukselle, ei käsitteitä juurikaan selailla, vaikka muuten tuki ontologioiden hyödyntämiselle olisi olemassa. Myöskään sanastoa ei juurikaan selailla, mikäli aihe ja sanasto ovat tuttuja, jolloin asiasanojen merkitykset ovat etukäteen tiedossa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tool center point calibration is a known problem in industrial robotics. The major focus of academic research is to enhance the accuracy and repeatability of next generation robots. However, operators of currently available robots are working within the limits of the robot´s repeatability and require calibration methods suitable for these basic applications. This study was conducted in association with Stresstech Oy, which provides solutions for manufacturing quality control. Their sensor, based on the Barkhausen noise effect, requires accurate positioning. The accuracy requirement admits a tool center point calibration problem if measurements are executed with an industrial robot. Multiple possibilities are available in the market for automatic tool center point calibration. Manufacturers provide customized calibrators to most robot types and tools. With the handmade sensors and multiple robot types that Stresstech uses, this would require great deal of labor. This thesis introduces a calibration method that is suitable for all robots which have two digital input ports free. It functions with the traditional method of using a light barrier to detect the tool in the robot coordinate system. However, this method utilizes two parallel light barriers to simultaneously measure and detect the center axis of the tool. Rotations about two axes are defined with the center axis. The last rotation about the Z-axis is calculated for tools that have different width of X- and Y-axes. The results indicate that this method is suitable for calibrating the geometric tool center point of a Barkhausen noise sensor. In the repeatability tests, a standard deviation inside robot repeatability was acquired. The Barkhausen noise signal was also evaluated after recalibration and the results indicate correct calibration. However, future studies should be conducted using a more accurate manipulator, since the method employs the robot itself as a measuring device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis studies the impact of the latest Russian crisis on global markets, and especially Central and Eastern Europe. The results are compared to other shocks and crises over the last twenty years to see how significant they have been. The cointegration process of Central and Eastern European financial markets is also reviewed and updated. Using three separate conditional correlation GARCH models, the latest crisis is not found to have initiated similar surges in conditional correlations to previous crises over the last two decades. Market cointegration for Central and Eastern Europe is found to have stalled somewhat after initial correlation increases post EU accession.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this thesis was to study the effect of pulsed electric field on the preparation of TiO2 nanoparticles via sol-gel method under the visible light irradiation. The literature part introduces properties of different TiO2 crystal forms and principle of photocatalysis. It was expected that pulsed electric field would have an influence on degradation for oxalic acid and formic acid. TiO2 samples were prepared by using three frequencies (50Hz, 294Hz, and 963Hz) and two treatment times (12 minutes and 24 minutes) of pulsed electric field. The photocatalytic activities of TiO2 samples produced with sol-gel method were also compared with the TiO2 particles made by previous study and with the commercial TiO2 powder Aeroxide® (Evonic Degussa GmbH) at the same condition. Results show that pulsed electric field does have an effect on degradation for oxalic acid and formic acid. Generally, higher photocatalytic activities for oxalic acid and formic acid were obtained with lower frequency and longer treatment time of pulsed electric field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Point-of-care (POC) –diagnostics is a field with rapidly growing market share. As these applications become more widely used, there is an increasing pressure to improve their performance to match the one of a central laboratory tests. Lanthanide luminescence has been widely utilized in diagnostics because of the numerous advantages gained by the utilization of time-resolved or anti-Stokes detection. So far the use of lanthanide labels in POC has been scarce due to limitations set by the instrumentation required for their detection and the shortcomings, e.g. low brightness, of these labels. Along with the advances in the research of lanthanide luminescence, and in the field of semiconductors, these materials are becoming a feasible alternative for the signal generation also in the future POC assays. The aim of this thesis was to explore ways of utilizing time-resolved detection or anti-Stokes detection in POC applications. The long-lived fluorescence for the time-resolved measurement can be produced with lanthanide chelates. The ultraviolet (UV) excitation required by these chelates is cumbersome to produce with POC compatible fluorescence readers. In this thesis the use of a novel light-harvesting ligand was studied. This molecule can be used to excite Eu(III)-ions at wavelengths extending up to visible part of the spectrum. An enhancement solution based on this ligand showed a good performance in a proof-of-concept -bioaffinity assay and produced a bright signal upon 365 nm excitation thanks to the high molar absorptivity of the chelate. These features are crucial when developing miniaturized readers for the time-resolved detection of fluorescence. Upconverting phosphors (UCPs) were studied as an internal light source in glucose-sensing dry chemistry test strips and ways of utilizing their various emission wavelengths and near-infrared excitation were explored. The use of nanosized NaYF :Yb3+,Tm3+-particles enabled the replacement of an external UV-light source with a NIR-laser and gave an additional degree of freedom in the optical setup of the detector instrument. The new method enabled a blood glucose measurement with results comparable to a current standard method of measuring reflectance. Microsized visible emitting UCPs were used in a similar manner, but with a broad absorbing indicator compound filtering the excitation and emission wavelengths of the UCP. This approach resulted in a novel way of benefitting from the non-linear relationship between the excitation power and emission intensity of the UCPs, and enabled the amplification of the signal response from the indicator dye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rare-earth based upconverting nanoparticles (UCNPs) have attracted much attention due to their unique luminescent properties. The ability to convert multiple photons of lower energy to ones with higher energy through an upconversion (UC) process offers a wide range of applications for UCNPs. The emission intensities and wavelengths of UCNPs are important performance characteristics, which determine the appropriate applications. However, insufficient intensities still limit the use of UCNPs; especially the efficient emission of blue and ultraviolet (UV) light via upconversion remains challenging, as these events require three or more near-infrared (NIR) photons. The aim of the study was to enhance the blue and UV upconversion emission intensities of Tm3+ doped NaYF4 nanoparticles and to demonstrate their utility in in vitro diagnostics. As the distance between the sensitizer and the activator significantly affect the energy transfer efficiency, different strategies were explored to change the local symmetry around the doped lanthanides. One important strategy is the intentional co-doping of active (participate in energy transfer) or passive (do not participate in energy transfer) impurities into the host matrix. The roles of doped passive impurities (K+ and Sc3+) in enhancing the blue and UV upconversions, as well as in influencing the intense UV upconversion emission through excess sensitization (active impurity) were studied. Additionally, the effects of both active and passive impurity doping on the morphological and optical performance of UCNPs were investigated. The applicability of UV emitting UCNPs as an internal light source for glucose sensing in a dry chemistry test strip was demonstrated. The measurements were in agreement with the traditional method based on reflectance measurements using an external UV light source. The use of UCNPs in the glucose test strip offers an alternative detection method with advantages such as control signals for minimizing errors and high penetration of the NIR excitation through the blood sample, which gives more freedom for designing the optical setup. In bioimaging, the excitation of the UCNPs in the transparent IR region of the tissue permits measurements, which are free of background fluorescence and have a high signal-to-background ratio. In addition, the narrow emission bandwidth of the UCNPs enables multiplexed detections. An array-in-well immunoassay was developed using two different UC emission colours. The differentiation between different viral infections and the classification of antibody responses were achieved based on both the position and colour of the signal. The study demonstrates the potential of spectral and spatial multiplexing in the imaging based array-in-well assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hammaslääketieteessä käytetettävien komposiittien valonläpäisevyys vaihtelee. Samoin LED-valokovettimet eroavat toisistaan valotehonsa ja muotoilunsa perusteella. On yleisesti tiedossa, että valokovettimesta tulevan valon intensiteetti pinta-alayksikköä kohden heikkenee, kun kovettimen etäisyys kasvaa. Toisaalta ei ole tiedossa, miten valokovetettavan kohteen ja valokovettimen kärjen väliin sijoitettu materiaali tarkalleenottaen vaikuttaa valon intensiteettiin eri etäisyyksiä käytettäessä. Tämän tutkimuksen tarkoituksena on selvittää, miten valokovetettavan kohteen ja valokovettimen kärjen väliin asetettava etukäteen polymerisoitu materiaali vaikuttaa valon intensiteettiin eri etäisyyksillä. Tutkimus suoritettiin käyttämällä kahta eri valokovetinta. Jotta etäisyyden vaikutusta valotustehoon voitiin demonstroida, vaihdettiin kovettimen etäisyyttä sensorista 0,2,4,6,8,10mm välillä. Valotehot rekisteröitiin MARC resin calibrator -laitteella. Sensorin ja valokovettimen kärjen väliin asetettavat erilaiset komposiittilevyt olivat valmiiksi kovetettuja,1mm paksuisia, filleripitoisuuksiltaan neljää erilaista muovia. Valotehot rekisteröitiin jokaiselta etäisyydeltä komposiitin ollessa sensorin päällä. Rinnakkaisesti verrattiin myös etäisyyden vaikutusta valotehoon ilman esikovetettua materiaalia kovettimen kärjen ja valoa mittaavan sensorin välissä. Vertailun suorittamiseksi laskettiin intensiteettisuhdeluku muovillisen ja muovittoman arvon välillä aina tietyllä etäisyydellä Valokovettimen kärjen etäisyyden kasvattaminen sensorista (eli valokovetettavasta kohteesta) odotusten mukaisesti pienensi valotehoa. Laittamalla sensorin ja kovettimen väliin komposiittilevy, valoteho pieneni odotetusti vielä enemmän. Tutkittaessa intensiteettisuhdetta (valoteho muovin kanssa : valoteho ilman muovia) kuitenkin huomattiin, että 4-6mm:n kohdalla suhdeluku oli suurempi kuin 0,2,8 ja 10mm kohdalla. Johtopäätöksenä oli, että suurin mahdollinen valokovetusteho saavutetan laittamalla kovetuskärki mahdollisimman lähelle kohdetta. Jos valokovetettavan kohteen ja valokovettimen kärjen välissä oli kiinteä komposiittipalanen, suurin mahdollinen valokovetusteho kohteeseen saavutetaan edelleen laittamalla kovetuskärki kiinni muoviin. Jos etäisyyttä muovin pinnasta sen sijaan kasvatettiin, valokovetusteho ei laskenutkaan niin nopeasti kuin oli odotettu. Tämä voi liittyä siihen, että tehokkaan valokeilan halkaisijan koko on suurempi verrattuna komposiitin sekä sensorin halkaisian kokoon. Toiseksi on arvioitu, että resiinikomposiitin täyteaineet voisivat fokusoida läpi kulkevaa valoa sensoriin. Se, pitääkö tämä ilmiö paikkansa, vaatii kuitenkin enemmän tutkimusta

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The underwater light field is an important environmental variable as it, among other things, enables aquatic primary production. Although the portion of solar radiation that is referred to as visible light penetrates water, it is restricted to a limited surface water layer because of efficient absorption and scattering processes. Based on the varying content of optical constituents in the water, the efficiency of light attenuation changes in many dimensions and over various spatial and temporal scales. This thesis discusses the underwater light dynamics of a transitional coastal archipelago in south-western Finland, in the Baltic Sea. While the area has long been known to have a highly variable underwater light field, quantified knowledge on the phenomenon has been scarce, patchy, or non-existent. This thesis focuses on the variability in the underwater light field through euphotic depths (1% irradiance remaining), which were derived from in situ measurements of vertical profiles of photosynthetically active radiation (PAR). Spot samples were conducted in the archipelago of south-western Finland, mainly during the ice-free growing seasons of 2010 and 2011. In addition to quantifying both the seasonal and geographical patterns of euphotic depth development, the need and usability of underwater light information are also discussed. Light availability was found to fluctuate in multiple dimensions and scales. The euphotic depth was shown to have combined spatio-temporal dynamics rather than separate changes in spatial and temporal dimensions. Such complexity in the underwater light field creates challenges in data collection, as well as in its utilisation. Although local information is needed, in highly variable conditions spot sampled information may only poorly represent its surroundings. Moreover, either temporally or spatially limited sampling may cause biases in understanding underwater light dynamics. Consequently, the application of light availability data, for example in ecological modelling, should be made with great caution.