44 resultados para Frequency stability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Induction motors are widely used in industry, and they are generally considered very reliable. They often have a critical role in industrial processes, and their failure can lead to significant losses as a result of shutdown times. Typical failures of induction motors can be classified into stator, rotor, and bearing failures. One of the reasons for a bearing damage and eventually a bearing failure is bearing currents. Bearing currents in induction motors can be divided into two main categories; classical bearing currents and inverter-induced bearing currents. A bearing damage caused by bearing currents results, for instance, from electrical discharges that take place through the lubricant film between the raceways of the inner and the outer ring and the rolling elements of a bearing. This phenomenon can be considered similar to the one of electrical discharge machining, where material is removed by a series of rapidly recurring electrical arcing discharges between an electrode and a workpiece. This thesis concentrates on bearing currents with a special reference to bearing current detection in induction motors. A bearing current detection method based on radio frequency impulse reception and detection is studied. The thesis describes how a motor can work as a “spark gap” transmitter and discusses a discharge in a bearing as a source of radio frequency impulse. It is shown that a discharge, occurring due to bearing currents, can be detected at a distance of several meters from the motor. The issues of interference, detection, and location techniques are discussed. The applicability of the method is shown with a series of measurements with a specially constructed test motor and an unmodified frequency-converter-driven motor. The radio frequency method studied provides a nonintrusive method to detect harmful bearing currents in the drive system. If bearing current mitigation techniques are applied, their effectiveness can be immediately verified with the proposed method. The method also gives a tool to estimate the harmfulness of the bearing currents by making it possible to detect and locate individual discharges inside the bearings of electric motors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microfibrillated cellulose (MFC) is known to enhance strength properties of paper. Improved strength usually means increased bonding which is strongly connected to dimensional instability of paper. Dimensional instability is due to changes in moisture content of paper; when paper is moistened it expands and when dried, it shrinks. Hygroexpansion is linked to end-use problems and excessive drying shrinkage consumes strength potential. Effective use of materials requires controlling of these phenomena. There isn’t yet data concerning dimensional stability of papers containing MFC which restricts wider use of MFC. Main objective of the work was to evaluate dimensional stability of wood-free paper containing different amounts of MFC. Sheets were dried with different methods to see how drying strains effected on drying shrinkage and hygroexpansion. Also tensile strength was measured to find out the effect of MFC. Results were compared to sheets containing kraft fines and in some test points cationic starch was used alongside with MFC. MFC increased the dimensional instability of freely dried sheets. As the amounts of MFC increased the effects on dimensional stability became more severe. However the fineness of MFC didn’t play any important role. Both hygroexpansion and drying shrinkage were decreased with cationic starch addition. Prevention of drying shrinkage over powered the effects of additives on hygroexpansion. Tensile strength improved up till 7 % addition amount which could be set as the upper limit of MFC addition when paper preparation and tensile strength are concerned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lukuisissa teollisuussovelluksissa materiaalien, kuten paperin ja teräslevyjen, muokkaamiseen käytettävät pyörivät nippitelat kärsivät aina erilaisten herätteiden synnyttämistä mekaanisista värähtelyistä, jotka voivat aiheuttaa virheitä valmistettaviin tuotteisiin. Tässä työssä tutkittiin viskoelastisia polymeerejä ja polymeeripinnoitteen nipilliseen telasysteemiin synnyttämiä haitallisia itseherätteisiä värähtelyjä. Työn polymeerejä käsittelevässä kirjallisuusosassa luotiin katsaus amorfisten polymeerien fysikaalisiin ominaisuuksiin. Kokeellisessa osuudessa tutkittiin tarkemmin kahden amorfisen telapinnoitepolymeerin termoreologisia ja mekaanisia ominaisuuksia suoritettujen DMTA-mittausten perusteella. Sovittamalla toisen polymeerin master-käyrään yleistetty lineaarisen standardiaineen malli saatiin selville polymeerin mekaaniset parametrit ja approksimaatio sen relaksaatiospektrille. Telapinnoitteen nipilliseen systeemiin synnyttämiä itseherätteisiä värähtelyjä ja niiden seurauksia tarkasteltiin kahdelle telalle ja polymeeripinnoitteelle kehitetyn analyyttisen mallin ja numeeristen laskujen avulla. Pinnoite mallinnettiin lineaarisen standardiaineen mukaisesti. Telasysteemin parametrit määritettiin DMTA-mittaustuloksista ja systeemiä vastaavasta koelaitteesta kokeellisella moodianalyysillä ja elementtimenetelmällä. Numeerisesta stabiilisuusanalyysistä ja liikeyhtälöiden integroinneista saadut tulokset kertovat telapinnoitteen aaltomaisista deformaatiomuodoista ja niiden synnyttämistä taajuusalueittain esiintyvistä epästabiileista värähtelyistä. Telasysteemi on epästabiili pinnoitedeformaatiokuvion systeemiin aiheuttaman herätevoiman taajuuden ollessa lähellä systeemin korkeampaa ominaistaajuutta. Numeerisista tuloksista voitiin ennustaa nopean ja hitaan barringin olemassaolo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This master’s thesis is focused on power supply network disturbances and their effects on the frequency converter – one of the components of modern process crane electrical system. The most critical disturbance types, their causes and the effect they bring to crane electrical system was determined in this work. Variety of protective devices used for mitigation of disturbances is investigated. Device protection solutions for the frequency converter used in crane applications are presented. Analyses of the power supply requirements for frequency converter and various components of crane electrical system were carried out and as a result the crane power supply requirements list that guarantees normal crane operation was built. This list is to be included in crane projects for troubleshooting purposes in order to determine potentially dangerous network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing power demand and emerging applications drive the design of electrical power converters into modularization. Despite the wide use of modularized power stage structures, the control schemes that are used are often traditional, in other words, centralized. The flexibility and re-usability of these controllers are typically poor. With a dedicated distributed control scheme, the flexibility and re-usability of the system parts, building blocks, can be increased. Only a few distributed control schemes have been introduced for this purpose, but their breakthrough has not yet taken place. A demand for the further development offlexible control schemes for building-block-based applications clearly exists. The control topology, communication, synchronization, and functionality allocationaspects of building-block-based converters are studied in this doctoral thesis. A distributed control scheme that can be easily adapted to building-block-based power converter designs is developed. The example applications are a parallel and series connection of building blocks. The building block that is used in the implementations of both the applications is a commercial off-the-shelf two-level three-phase frequency converter with a custom-designed controller card. The major challenge with the parallel connection of power stages is the synchronization of the building blocks. The effect of synchronization accuracy on the system performance is studied. The functionality allocation and control scheme design are challenging in the seriesconnected multilevel converters, mainly because of the large number of modules. Various multilevel modulation schemes are analyzed with respect to the implementation, and this information is used to develop a flexible control scheme for modular multilevel inverters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct torque control (DTC) is a new control method for rotating field electrical machines. DTC controls directly the motor stator flux linkage with the stator voltage, and no stator current controllers are used. With the DTC method very good torque dynamics can be achieved. Until now, DTC has been applied to asynchronous motor drives. The purpose of this work is to analyse the applicability of DTC to electrically excited synchronous motor drives. Compared with asynchronous motor drives, electrically excited synchronous motor drives require an additional control for the rotor field current. The field current control is called excitation control in this study. The dependence of the static and dynamic performance of DTC synchronous motor drives on the excitation control has been analysed and a straightforward excitation control method has been developed and tested. In the field weakening range the stator flux linkage modulus must be reduced in order to keep the electro motive force of the synchronous motor smaller than the stator voltage and in order to maintain a sufficient voltage reserve. The dynamic performance of the DTC synchronous motor drive depends on the stator flux linkage modulus. Another important factor for the dynamic performance in the field weakening range is the excitation control. The field weakening analysis considers both dependencies. A modified excitation control method, which maximises the dynamic performance in the field weakening range, has been developed. In synchronous motor drives the load angle must be kept in a stabile working area in order to avoid loss of synchronism. The traditional vector control methods allow to adjust the load angle of the synchronous motor directly by the stator current control. In the DTC synchronous motor drive the load angle is not a directly controllable variable, but it is formed freely according to the motor’s electromagnetic state and load. The load angle can be limited indirectly by limiting the torque reference. This method is however parameter sensitive and requires a safety margin between the theoretical torque maximum and the actual torque limit. The DTC modulation principle allows however a direct load angle adjustment without any current control. In this work a direct load angle control method has been developed. The method keeps the drive stabile and allows the maximal utilisation of the drive without a safety margin in the torque limitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resonance energy transfer (RET) is a non-radiative transfer of the excitation energy from the initially excited luminescent donor to an acceptor. The requirements for the resonance energy transfer are: i) the spectral overlap between the donor emission spectrum and the acceptor absorption spectrum, ii) the close proximity of the donor and the acceptor, and iii) the suitable relative orientations of the donor emission and the acceptor absorption transition dipoles. As a result of the RET process the donor luminescence intensity and the donor lifetime are decreased. If the acceptor is luminescent, a sensitized acceptor emission appears. The rate of RET depends strongly on the donor–acceptor distance (r) and is inversely proportional to r6. The distance dependence of RET is utilized in binding assays. The proximity requirement and the selective detection of the RET-modified emission signal allow homogeneous separation free assays. The term lanthanide-based RET is used when luminescent lanthanide compounds are used as donors. The long luminescence lifetimes, the large Stokes’ shifts and the intense, sharply-spiked emission spectra of the lanthanide donors offer advantages over the conventional organic donor molecules. Both the organic lanthanide chelates and the inorganic up-converting phosphor (UCP) particles have been used as donor labels in the RET based binding assays. In the present work lanthanide luminescence and lanthanide-based resonance energy transfer phenomena were studied. Luminescence lifetime measurements had an essential role in the research. Modular frequency-domain and time-domain luminometers were assembled and used successfully in the lifetime measurements. The frequency-domain luminometer operated in the low frequency domain ( 100 kHz) and utilized a novel dual-phase lock-in detection of the luminescence. One of the studied phenomena was the recently discovered non-overlapping fluorescence resonance energy transfer (nFRET). The studied properties were the distance and temperature dependences of nFRET. The distance dependence was found to deviate from the Förster theory and a clear temperature dependence was observed whereas conventional RET was completely independent of the temperature. Based on the experimental results two thermally activated mechanisms were proposed for the nFRET process. The work with the UCP particles involved the measurement of the luminescence properties of the UCP particles synthesized in our laboratory. The goal of the UCP particle research is to develop UCP donor labels for binding assays. In the present work the effect of the dopant concentrations and the core–shell structure on the total up-conversion luminescence intensity, the red–green emission ratio, and the luminescence lifetime was studied. Also the non-radiative nature of the energy transfer from the UCP particle donors to organic acceptors was demonstrated for the first time in aqueous environment and with a controlled donor–acceptor distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämä työ on tehty Fingrid Oyj:lle. Työn tavoitteena oli tutkia, miten reaaliaikaista PMU-mittaustietoa voidaan hyödyntää voimajärjestelmän valvonnassa. Voimajärjestelmän dynaamisia ilmiöitä ovat jännite- ja kulmastabiilius. Työssä tutkittiin voimajärjestelmän kulmastabiiliutta PSS/E-ohjelmalla simuloitujen mittaustulosten perusteella. Fouriermuunnoksen tulokset osoittavat, että huonoiten vaimeneva taajuuskomponentti on 0,3 Hz taajuus. Lisäksi tiedetään, että huonosti vaimeneva taajuuskomponentti rajoittaa siirtokapasiteettia. Voimajärjestelmän stabiiliutta voidaan esittää Wide Area Monitoring -järjestelmien (WAMS) avulla. WAMS perustuu Phasor Measurement -laitteen (PMU) reaaliaikaiseen mittaustekniikkaan. Jännitteen vaihekulman mittaaminen mahdollistaa voimajärjestelmän tilan määrittämisen reaaliajassa. Työssä on esitelty Fingridin käytössä oleva WAMS ja lisäksi esitelty kolmen eri laitetoimittajan WAMS:n rakennetta ja operaattorin käyttöön tarkoitettuja käyttöliittymiä. WAMS:n rakenteet ovat pääpiirteittäin samanlaisia, mutta stabiiliuden visuaalisessa esittämisessä on eroja. PMU -mittaustietoja on mahdollista tuoda käytönvalvontajärjestelmään erillisellä tiedonsiirtoprotokollalla. PMU-mittaustiedon hyödyntäminen käytönvalvontajärjestelmän toimintaaluenäytöllä mahdollistaa verkon tilan esittämisen reaaliajassa. Roottorin kulmastabiilius esitetään Fingridin käytönvalvontajärjestelmässä vaihekulmaerojen avulla ja työssä on esitetty, kuinka vaihekulmaeron arvolla on vaikutus tehonsiirtoon. Vaihekulmaeron arvo kuvaa vian jälkeisen tehoheilahtelun voimakkuutta. PMU-mittaustiedon esittäminen antaa operaattorille selkeämmän kuvan ylläpitää tehonsiirto turvallisella tasolla ja epästabiilin heilahtelun havainnoiminen vähentää suurhäiriön riskiä. Tulevaisuudessa siirtoverkon kehittyessä tarvitaan operaattorin käyttöön myös nopeita stabiilisuutta esittäviä työkaluja.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pluripotent cells have the potential to differentiate into all somatic cell types. As the adult human body is unable to regenerate various tissues, pluripotent cells provide an attractive source for regenerative medicine. Human embryonic stem cells (hESCs) can be isolated from blastocyst stage embryos and cultured in the laboratory environment. However, their use in regenerative medicine is restricted due to problems with immunosuppression by the host and ethical legislation. Recently, a new source of pluripotent cells was established via the direct reprogramming of somatic cells. These human induced pluripotent stem cells (hiPSCs) enable the production of patient specific cell types. However, numerous challenges, such as efficient reprogramming, optimal culture, directed differentiation, genetic stability and tumor risk need to be solved before the launch of therapeutic applications. The main objective of this thesis was to understand the unique properties of human pluripotent stem cells. The specific aims were to identify novel factors involved in maintaining pluripotency, characterize the effects of low oxygen culture on hESCs, and determine the high resolution changes in hESCs and hiPSCs during culture and reprogramming. As a result, the previously uncharacterized protein L1TD1 was determined to be specific for pluripotent cells and essential for the maintenance of pluripotency. The low oxygen culture supported undifferentiated growth and affected expression of stem cell associated transcripts. High resolution screening of hESCs identified a number of culture induced copy number variations and loss of heterozygosity changes. Further, screening of hiPSCs revealed that reprogramming induces high resolution alterations. The results obtained in this thesis have important implications for stem cell and cancer biology and the therapeutic potential of pluripotent cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transportation of fluids is one of the most common and energy intensive processes in the industrial and HVAC sectors. Pumping systems are frequently subject to engineering malpractice when dimensioned, which can lead to poor operational efficiency. Moreover, pump monitoring requires dedicated measuring equipment, which imply costly investments. Inefficient pump operation and improper maintenance can increase energy costs substantially and even lead to pump failure. A centrifugal pump is commonly driven by an induction motor. Driving the induction motor with a frequency converter can diminish energy consumption in pump drives and provide better control of a process. In addition, induction machine signals can also be estimated by modern frequency converters, dispensing with the use of sensors. If the estimates are accurate enough, a pump can be modelled and integrated into the frequency converter control scheme. This can open the possibility of joint motor and pump monitoring and diagnostics, thereby allowing the detection of reliability-reducing operating states that can lead to additional maintenance costs. The goal of this work is to study the accuracy of rotational speed, torque and shaft power estimates calculated by a frequency converter. Laboratory tests were performed in order to observe estimate behaviour in both steady-state and transient operation. An induction machine driven by a vector-controlled frequency converter, coupled with another induction machine acting as load was used in the tests. The estimated quantities were obtained through the frequency converter’s Trend Recorder software. A high-precision, HBM T12 torque-speed transducer was used to measure the actual values of the aforementioned variables. The effect of the flux optimization energy saving feature on the estimate quality was also studied. A processing function was developed in MATLAB for comparison of the obtained data. The obtained results confirm the suitability of this particular converter to provide accurate enough estimates for pumping applications.