49 resultados para Dairy plants.
Resumo:
Selostus: Korjuuaika ja typpilannoitus vaikuttavat rehukasvien radiocesiumpitoisuuteen
Resumo:
Selostus: Laiduntamisen aloitusajankohdan vaikutus laitumen tuottoon
Resumo:
Nanotiltration is a membrane separation method known for its special characteristic of rejecting multivalent ions and passing monovalent ions. Thus, it is commonly applied with dilute aqueous solutions in partial salt removal, like in drinking water production. The possibilities of nanofiltration have been studied and the technique applied in a wide branch of industries, e.g. the pulp and paper, the textile and the chemical processing industry. However, most present applications and most of the potential applications studied involve dilute solutions, the permeating stream being generally water containing monovalent salts. In this study nanotiltration is investigated more as a fractionation method. A well-known application in the dairy industry is concentration and partial salt removal from whey. Concentration and partial demineralization is beneficial for futher processing of whey as whey concentrates are used e.g. in baby foods. In the experiments of this study nanotiltration effectively reduced the monovalent salts in the whey concentrate. The main concern in this application is lactose leakage into the permeate. With the nanofiltration membranes used the lactose retentions were practically ? 99%. Another dairy application studied was the purification and reuse of cleaning solutions. This is an environmentally driven application. An 80% COD reduction by nanofiltration was observed for alkaline cleaning-in-place solution. Nanofiltration is not as commonly applied in the sugar and sweeteners industry as in the dairy industry. In this study one potential application was investigated, namely xylose purification from hemicellulose hydrolyzate. Xylose is raw material for xylitol production. Xylose separation from glucose was initially studied with xylose-glucose model solutions. The ability of nanofiltration to partially separate xylose into the permeate from rather concentrated xylose-glucose solutions (10 w-% and 30 w-%) became evident. The difference in size between xylose and glucose molecules according to any size measure is small, e.g. the Stokes diameter of glucose is 0.73 nm compared to 0.65 nm for xylose. In further experiments, xylose was purified into nanoliltration permeate from a hemicellulose hydrolyzate solution. The xylose content in the total solids was increased by 1.4—1.7 fold depending on temperature, pressure and feed composition.
Resumo:
Venäjällä uudistetaan sähkömarkkinoita. Uudistamisella pyritään vapauttamaan sähkömarkkinat ja lisäämään kilpailua energiasektorilla. Sähkömarkkinoiden vapauttamisen tarkoitus on energiasektorin hyötysuhteen nostaminen ja investointien houkutteleminen sektorille. Venäjä on ratifioinut Kioton protokollan, mikä energiasektorin kannalta on tärkeää, koska protokollan yhteistoteutusmekanismin kautta saadaan houkuteltua investointeja sektorille. Venäjän sähkömarkkinoiden vapauttamisen pitkäaikainen tähtäin on Venäjän ja Euroopan sähkömarkkinoiden integroituminen, joka tarkoittaa myös ympäristölainsäädännönyhtenäistämistä. Tämä tutkimus on osa Fortum Oyj:n tarjoamaa teknistä katselmusta Venäjällä toimivalle sähköyhtiölle, TGC-9:lle. Tässä työssä keskitytään TGC-9:n omistamien energiatuotantolaitoksien happamoitumista aiheuttaviin ilmapäästöihin ja pölypäästöihin. Tutkimuksessa pyritään myös löytämään Kioton protokollan yhteistoteutusmekanismi hyödyntämiskohteita. NOx -päästöt tulevat olemaan suurin haaste TGC-9:lle, jos ympäristöstandardit yhdenmukaistetaan. Yhteistoteutusmekanismin hyödyntämiskohteita löydettiin neljä: koksaamokaasun hyödyntäminen, maakaasun korvaaminen kuoren poltolla ja kaksi tapausta liittyen laitoksien hyötysuhteen nostamiseen.
Resumo:
This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.
Resumo:
The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.
Resumo:
Selostus: Pellavan ja kuituhampun mikrobiologinen laatu kasvukauden aikana
Resumo:
Työssä on tarkasteltu kompressori- ja absorptiokylmälaitoksien teknisiä ratkaisuja ja laitoksien investointi- ja käyttökustannuksia. Työssä on keskitytty laitoksiin, jotka tuottavat alle nolla Celsiusasteen lämpötiloja. Esimerkkitapauksessa on selvitetty panimon ja meijerin kylmälaitoksen tekniikka ja kustannukset. Tutkimus perustuu kirjallisuuteen, haastatteluihin ja mittaustuloksiin. Kirjallisuuden avulla on selvitetty kylmälaitoksien tekniikkaa ja kustannusten muodostumista. Haastattelujen avulla on kerätty tietoa esimerkkikohteen nykyisistä laitteista, tulevaisuuden kylmätarpeesta ja kohteeseen sopivista laiteratkaisuista. Mittaustietojen avulla on arvioitu kylmäenergian tarve. Työn avulla on saatu näkemys esimerkkikohteeseen sopivasta kylmälaitoksesta ja sen aiheuttamista kustannuksista. Näiden tietojen avulla voidaan selvittää mahdollisten kylmäasiakkaiden kiinnostus kylmäenergian ostamiseen. Hankkeen toteutuessa työtä voidaan käyttää pohjana laitoksen ja kylmätoiminnan suunnittelussa.
Resumo:
This master’s thesis handles an operating model for an electric equipment supplier conducted sale oriented energy audit for pumping, fan and other motor applications at power plants. The study goes through the largest factors affecting internal electricity use at a power plant, finds an energy audit –like approach for the basis of information gathering and presents the information needed for conducting the analysis. The model is tested in practice at a kraft recovery boiler of a chemical pulping mill. Targets chosen represent some of the largest electric motor applications in the boiler itself and in its fuel handling. The energy saving potential of the chosen targets is calculated by simulating the energy consumption of the alternatives for controlling the targets, and thereafter combining the information with the volume flow duration curve. Results of the research are somewhat divaricated, as all the information needed is not available in the automation system. Some of the targets could be simulated and their energy saving potential calculated quite easily. At some of the targets chosen the monitoring was not sufficient enough for this and additional measurements would have been needed to base the calculations on. In traditional energy audits, energy efficiency of pump and fan applications is not necessarily examined. This means that there are good possibilities for developing the now presented targeted energy audit procedure basis further.
Resumo:
The paper is focused on feasibility study and market review of small scale bioenergy heating plants in the Russian North-West region. The main focus is effective and competitive usage of low-grade wood for heating purposes in the region. As example of economical feasibility estimation it was chosen the project of reconstruction of small scale boiler plant in Leningrad region that Brofta Oy is planning to implement the nearest time. It includes calculation the payback time with and without interest, the estimation of probable investments, the evaluation of possible risks and research on the potential of small scale heating plants projects. Calculations show that the profitability of this kind of projects is high, but payback time is not very short, because of high level of initial investments. Though, the development of small scale bioenergy heating plants in the region is considered to be the best way to solve the problems of heat supply in small settlements using own biomass resources.