24 resultados para Cholesterol Determination
Resumo:
Chlorophenols have been classified as possible carcinogens for humans. Chlorophenols have been used as pesticides and wood preservatives. In Finland, during 1930 – 1980s, saw mills used KY-5 wood preservative that contained 2,4,6-TCP, 2,3,4,6-TeCP and PCP. Especially in Finland chlorophenols have entered the environment by leaking from contaminated grounds of old saw mills. Although chlorophenol concentrations found in environment do not cause acute concern, long term exposure can increase the risk of cancer. SPME is relatively cheap and simple sampling method, in which the sample extraction and concentration are performed in a single step. Solvents are not required in SPME. IMS is based on the detection of sample ion drift times. Based on the drift times, reduced mobilities are calculated, which are comparable despite the measurement conditions. SPME-IMS coupling has not been used earlier in the determination of chlorophenols from water samples. The scope of this work was to study, if SPME-IMS system is suitable for detecting chloro-phenols from water samples. The aim was to determine the most optimal extraction condi-tions, which were then applied to real water samples. Following detection limits were deter-mined: 2,4,6-TCP: 0.33 mg/l; 2,3,4,6-TeCP: 0.63 mg/l and PCP: 1.63 mg/l. Detection limits were high compared to the highest possible chlorophenol concentration that is allowed in Finnish drinking water, 10 μg/l. Detected concentrations from water sample differed from verified concentrations in the case of 2,3,4,6-TeCP by 4.6 % and in the case of 2,4,6-TCP by 48.4 %. Based on the results it can be said that SPME-IMS setup is suitable for preliminary analysis of mg/l chlorophenol concentrations from water samples.
Resumo:
Vaahdotusta käytetään yleisesti erottamaan eri mineraaleja malmista. Tässä menetelmässä käytetään erityisiä pinta-aktiivisia aineita, joita kutsutaan kokoojakemikaaleiksi, muuntamaan halutut mineraalit hydrofobisiksi ja erottamaan ne hydrofiilisistä partikkeleista ilmakuplien avulla. Eräs tärkeimmistä kokoojakemikaalien ryhmistä on ksantaatit. Ksantaateilla on havaittu taipumusta hajota useiksi erilaisiksi hajoamistuotteiksi vaahdotusprosessin aikana. Näillä hajoamistuotteilla voi olla monia haitallisia vaikutuksia vaahdotuksen tuloksiin. Näiden tuotteiden tunnistaminen ja määrittäminen on tärkeää vaahdotusprosessin paremman ymmärtämisen kannalta. Työn kirjallisuusosassa vaahdotusprosessi, ksantaatit ja niiden yleisimmät hajoamistuotteet on esitelty, kuten myös käytetty analyysimenetelmä, kapillaarielektroforeesi. Työn kokeellisessa osassa etsittiin sopivaa erotusmenetelmää etyyliksantaatin, etyylitiokarbonaatin, etyyliperksantaatin ja etyyliksantyylitiosulfaatin erottamiseksi kapillaarilelektroforeesilla. Pääasiassa keskityttiin kahteen eri erotusmenetelmään. Ensimmäinen menetelmä kykeni erottamaan kaikki tutkitut tuotteet puhdasvesinäytteissä, ja toinen menetelmä oli sopiva näiden tuotteiden erottamiseen prosessivesinäytteissä. Jälkimmäistä menetelmää kokeiltiin käytännössä rikastamolla, jossa sillä kyettiin erottamaan isobutyyliksantaatti, isobutyylitiokarbonaatti, ja suurella todennäköisyydellä myös isobutyyliperksantaatti.
Resumo:
Vaahdotusprosessia käytetään yleisesti erottamaan arvokkaita mineraaleja malmeista. Toimiakseen tehokkaasti prosessi tarvitsee kokoojakemikaaleja, joiden tehtävänä on sitoa halutut mineraalit ilmakupliin. Jotta näiden kemikaalien käyttäytymistä prosessissa voitaisiin ymmärtää paremmin ja prosessin ohjausta tehostaa, pitää kokoojia pystyä analysoimaan prosessivesistä. Työn kirjallisuusosassa on koottu ja vertailtu erilaisia kirjallisuudesta löytyneitä analyysimenetelmiä kokoojakemikaaleille. Kokeellisessaosassa on kehitetty kaksi kapillaarielektroforeesimenetelmää näiden kemikaalien tutkimiseen. Menetelmien toteamisrajat tutkituille kemikaaleille olivat seuraavanlaiset: natrium diiosobutylditiofosfaattille (DTP) 2,7 mg/L puhtaassa vedessä ja 6,7 mg/L prosessivedessä; natrium diisobutyldithiofosfinaatille (DTPI) vastaavasti 4,5 mg/L ja 6,7 mg/L; etyyli ksantaatille 0,025 mg/L ja 0,16 mg/L; ja isobutyyli ksantaatille 0,41 mg/L ja 0,62 mg/L. Näitä menetelmiä voidaan tulevaisuudessa kehittää kokoojien hajoamistuotteiden analysointia varten sekä prosessien on-line mittauksiin.
Resumo:
Valuable minerals can be recovered by using froth flotation. This is a widely used separation technique in mineral processing. In a flotation cell hydrophobic particles attach on air bubbles dispersed in the slurry and rise on the top of the cell. Valuable particles are made hydrophobic by adding collector chemicals in the slurry. With the help of a frother reagent a stable froth forms on the top of the cell and the froth with valuable minerals, i.e. the concentrate, can be removed for further processing. Normally the collector is dosed on the basis of the feed rate of the flotation circuit and the head grade of the valuable metal. However, also the mineral composition of the ore affects the consumption of the collector, i.e. how much is adsorbed on the mineral surfaces. Therefore it is worth monitoring the residual collector concentration in the flotation tailings. Excess usage of collector causes unnecessary costs and may even disturb the process. In the literature part of the Master’s thesis the basics of flotation process and collector chemicals are introduced. Capillary electrophoresis (CE), an analytical technique suitable for detecting collector chemicals, is also reviewed. In the experimental part of the thesis the development of an on-line CE method for monitoring the concentration of collector chemicals in a flotation process and the results of a measurement campaign are presented. It was possible to determine the quality and quantity of collector chemicals in nickel flotation tailings at a concentrator plant with the developed on-line CE method. Sodium ethyl xanthate and sodium isopropyl xanthate residuals were found in the tailings and slight correlation between the measured concentrations and the dosage amounts could be seen.
Resumo:
Cholesterol (Chol) is an important lipid in cellular membranes functioning both as a membrane fluidity regulator, permeability regulator and co-factor for some membrane proteins, e.g. G-protein coupled receptors. It also participates in the formation of signaling platforms and gives the membrane more mechanical strenght to prevent osmotic lysis of the cell. The sterol structure is very conserved and already minor structural modifications can completely abolish its membrane functions. The right interaction with adjacent lipids and the preference of certain lipid structures over others are also key factors in determining the membrane properties of cholesterol. Because of the many important properties of cholesterol it is of value to understand the forces and structural properties that govern the membrane behavior of this sterol. In this thesis we have used established fluorescence spectroscopy methods to study the membrane behavior of both cholesterol and some of its 3β-modified analogs. Using several fluorescent probes we have established how the acyl chain order of the two main lipid species, sphingomyelin (SM) and phosphatidylcholine (PC) affect sterol partitioning as well as characterized the membrane properties of 3β-aminocholesterol and cholesteryl phosphocholine. We concluded that cholesterol prefers SM over PC at equal acyl chain order, indicating that other structural properties besides the acyl chain order are important for sphingomyelin-sterol interactions. A positive charge at the 3β position only caused minor changes in the sterol membrane behavior compared to cholesterol. A large phosphocholine head group caused a disruption in membrane packing together with other membrane lipids with large head groups, but was also able to form stable fluid bilayers together with ceramide and cholesterol. The Ability of the large head group sterol to form bilayers together with ceramide was further explored in the last paper where cholesteryl phosphocholine/ceramide (Chol-PC/Cer) complexes were successfully used to transfer ceramide into cultured cells.
Resumo:
The purpose of this exploratory research is to identify the potential value drivers regarding a new service offering. More specifically, the aim is to build understanding of customer expectations and perceived value of energy efficiency solutions in the building’s sector. The knowledge is then used in defining potential value drivers. The research is conducted from the customer’s perspective in a business-to-business context. The theory part of the master’s thesis focuses on discussing the antecedents of customer expectations and customer value. The theory gives implications how to determine value drivers and develop value propositions as well as conduct value assessment. The empirical part is based on the qualitative research method. The research was conducted as a single-case study, and the primary data was collected through semi-structured interviews with potential customers. The results of the research revealed that the customer expectations are connected to being able to define value drivers. In addition, the research revealed generic themes relating to the offering and customer-supplier relationship, which help in the process of identifying potential value drivers. The results were discussed in terms of product-, service-, price- and relationship-related value drivers for the new service. Based on the data analysis the dominant value drivers are elaborated in terms of identified customer benefits and customer sacrifices (costs). Finally, some implications of value proposition and value assessment to support the value delivery were given.
Resumo:
Energy efficiency is an important topic when considering electric motor drives market. Although more efficient electric motor types are available, the induction motor remains as the most common industrial motor type. IEC methods for determining losses and efficiency of converter-fed induction motors were introduced recently with the release of technical specification IEC/TS 60034-2-3. Determining the induction motor losses with IEC/TS 60034-2-3 method 2-3-A and assessing the practical applicability of the method are the main interests of this study. The method 2-3-A introduces a specific test converter waveform to be used in the measurements. Differences between the induction motor losses with a test converter supply, and with a DTC converter supply are investigated. In the IEC methods, the tests are run at motor rated fundamental voltage, which, in practice, requires the frequency converter to be fed with a risen input voltage. In this study, the tests are run on both frequency converters with artificially risen converter input voltage, resulting in rated motor fundamental input voltage as required by IEC. For comparison, the tests are run with both converters on normal grid input voltage supply, which results in lower motor fundamental voltage and reduced flux level, but should be more relevant from practical point of view. According to IEC method 2-3-A, tests are run at rated motor load, and to ensure comparability of the results, the rated load is used in the grid-fed converter measurements, although motor is overloaded while producing the rated torque at reduced flux level. The IEC 2-3-A method requires also sinusoidal supply test results with IEC method 2-1-1B. Therefore, the induction motor losses with the recently updated IEC 60034-2-1 method 2-1-1B are determined at the motor rated voltage, but also at two lower motor voltages, which are according to the output fundamental voltages of the two network-supplied converters. The method 2-3-A was found to be complex to apply but the results were stable. According to the results, the method 2-3-A and the test converter supply are usable for comparing losses and efficiency of different induction motors at the operating point of rated voltage, rated frequency and rated load, but the measurements do not give any prediction of the motor losses at final application. One might therefore strongly criticize the method’s main principles. It seems, that the release of IEC 60034-2-3 as a technical specification instead of a final standard for now was justified, since the practical relevance of the main method is questionable.
Resumo:
A new approach to the determination of the thermal parameters of high-power batteries is introduced here. Application of local heat flux measurement with a gradient heat flux sensor (GHFS) allows determination of the cell thermal parameters in di_erent surface points of the cell. The suggested methodology is not cell destructive as it does not require deep discharge of the cell or application of any charge/discharge cycles during measurements of the thermal parameters of the cell. The complete procedure is demonstrated on a high-power Li-ion pouch cell, and it is verified on a sample with well-known thermal parameters. A comparison of the experimental results with conventional thermal characterization methods shows an acceptably low error. The dependence of the cell thermal parameters on state of charge (SoC) and measurement points on the surface was studied by the proposed measurement approach.
Resumo:
Older age increases the risk of developing a chronic atherosclerotic cardiovascular disease (CVD), such as coronary heart disease. Complications of CVDs, myocardial infarction or stroke often lead to loss of functional capacity or premature death. Dyslipidemia, high serum levels of total or low-density lipoprotein cholesterol (LDL-c) and low levels of high-density lipoprotein cholesterol (HDL-c), is among the most important modifiable risk factors for CVDs; it can be treated with lifestyle modifications, and with lipid-lowering drugs, primarily statins. In older persons, however, the association of cholesterol levels with cardiovascular and all-cause mortality has been inconsistent in previous studies. Furthermore, the beneficial effects of statins in older persons without previous CVD are still somewhat unclear, and older persons are more prone to adverse effects from statins. This thesis presents a prospective cohort study (TUVA), exploring associations of cholesterol levels with mortality and the changes in cholesterol levels of a 70-year-old population in long-term follow-up. Further, prevalence of CVDs, risk factors and preventive medication use in the TUVA cohort is compared with respective prevalences in another age-matched cohort (UTUVA) 20 years later in order to examine the changes in cardiovascular risk over time. Additionally, to evaluate statin use patterns among older persons, an observational register study was conducted covering the total Finnish population aged 70 and older during 2000-2008. Based on individual-level data retrieved from national health registries, the population was classified into low, moderate and high risk groups according to estimated CVD risk. The prevalence, incidence and persistence of statin use among the risk groups was then evaluated based upon yearly statin purchases tracked from the Prescription Register. The prospective cohort study demonstrated that low total cholesterol, LDL-c and HDL-c were associated with higher mortality in a cohort of home-dwelling 70-year-olds. However, after adjusting for traditional cardiovascular risk factors and cancer this association disappeared. Further, low total cholesterol seemed to be protective, whereas low HDL-c strongly predicted increased risk of CVD death. Cholesterol levels of those elderly who remained available for follow-up and were still home-dwelling at the age of 85 seemed to improve with advancing age. Compared to the TUVA cohort, the later born UTUVA cohort had less CVDs and their risk factors were better controlled, which was reflected in the higher use of preventive medications such as statins and antihypertensives. The register studies confirmed that statin use has increased significantly during 2000-2008 among older persons, especially among the oldest (80+) age groups and among those at high risk for cardiovascular events. Two-thirds of new statin users persisted with their use during the four years of follow-up; the most discontinuations were made during the first year of use. In conclusion, statins are commonly used among older age groups in Finland. Most of the older statin users had a high cardiovascular event risk, indicating that the treatment is well directed towards those who are likely to benefit from it the most. No age-limits should be put on the screening and treatment of dyslipidemia in older persons, but the benefits and adverse effects of statin treatment should be carefully weighed based on an individual assessment of the person’s general health status and functional capacity. Physicians should pay more attention to medication adherence, especially when prescribing preventive medications.