2 resultados para reproductive peak
Resumo:
INTRODUCTION Although several parameters have been proposed to predict the hemodynamic response to fluid expansion in critically ill patients, most of them are invasive or require the use of special monitoring devices. The aim of this study is to determine whether noninvasive evaluation of respiratory variation of brachial artery peak velocity flow measured using Doppler ultrasound could predict fluid responsiveness in mechanically ventilated patients. METHODS We conducted a prospective clinical research in a 17-bed multidisciplinary ICU and included 38 mechanically ventilated patients for whom fluid administration was planned due to the presence of acute circulatory failure. Volume expansion (VE) was performed with 500 mL of a synthetic colloid. Patients were classified as responders if stroke volume index (SVi) increased >or= 15% after VE. The respiratory variation in Vpeakbrach (DeltaVpeakbrach) was calculated as the difference between maximum and minimum values of Vpeakbrach over a single respiratory cycle, divided by the mean of the two values and expressed as a percentage. Radial arterial pressure variation (DeltaPPrad) and stroke volume variation measured using the FloTrac/Vigileo system (DeltaSVVigileo), were also calculated. RESULTS VE increased SVi by >or= 15% in 19 patients (responders). At baseline, DeltaVpeakbrach, DeltaPPrad and DeltaSVVigileo were significantly higher in responder than nonresponder patients [14 vs 8%; 18 vs. 5%; 13 vs 8%; P < 0.0001, respectively). A DeltaVpeakbrach value >10% predicted fluid responsiveness with a sensitivity of 74% and a specificity of 95%. A DeltaPPrad value >10% and a DeltaSVVigileo >11% predicted volume responsiveness with a sensitivity of 95% and 79%, and a specificity of 95% and 89%, respectively. CONCLUSIONS Respiratory variations in brachial artery peak velocity could be a feasible tool for the noninvasive assessment of fluid responsiveness in patients with mechanical ventilatory support and acute circulatory failure. TRIAL REGISTRATION ClinicalTrials.gov ID: NCT00890071.
Resumo:
BACKGROUND Assisted reproductive technology (ART) with washed semen can achieve pregnancy with minimal risk of horizontal and vertical transmission of chronic viral diseases (CVD) such as human immunodeficiency virus (HIV), hepati- tis C virus (HCV) and hepatitis B virus (HBV) among serodiscordant couples. How- ever, few studies have been made of the use made by these couples of ARTs or of the obstetric results achieved. MATERIALS AND METHODS In this retrospective study, 93 men who were seropositive for HIV, HCV or HBV and who underwent assisted reproduction treatment at our centre (Hospital Universitario Virgen de las Nieves, Granada, Spain) were included. Washed semen was tested to detect viral particles. Non-infected women were tested before and after each treatment, as were the neonates at birth and after three months. RESULTS A total of 62 sperm samples were washed, and none were positive for the detec- tion of viral molecules. Semen samples from 34 HBV positive males were not washed since the female partner had immunity to hepatitis B. In total, 38 clinical pregnancies were achieved (22% per cycle and 40.9% per couple) out of 173 cycles initiated, and 28 births were achieved (16.2% per cycle and 30.1% per couple), producing 34 live births. The rate of multiple pregnancies was 21.4%. Obstetric and neonatal results were similar in the groups of couples studied. At follow-up, no seroconversion was detected in the women or neonates. CONCLUSION Sperm washing and intracytoplasmic sperm injection are shown to be a safe and effective option for reducing the risk of transmission or super infection in serodiscordant or concordant couples who wish to have a child. Pregnancies ob- tained by ART in couples when the male is CVD infected achieve good obstetric and neonatal results.