4 resultados para Saber de experiencia
Resumo:
We carried out a descriptive, retrospective study with a sample side of 121 patients with Legión® prosthesis replacement in our Vírgen del Rocío hospital area, in the city of Seville, from May of 2008 until March of 2011. This study included epidemiological data as well as technical information about the process performed, including post-operative pain, mobility and functional results using a functional assessment scale and series of radiological studies. Average follow-up was 19 months, with a mean age of 71 years and 87% women. We obtained an average of 20.41º for articular balance obtained, correction of prior deformities by restoring the tibia-femoral axis to the anatomic e balance articular angle; we resolved bone loss prior to replacement and carried out an adequate balance of the inter-lineal joint. 66% of the patients continued with no post-operative pain, with the other 33% reporting slight to moderate pain. With regards to pain at the point of the stem, we have found no significant relationship with the incidence angle of the stem on the cortical or with the type of cement. We observed a 74% rate of intervention without complications, with complications being rupture of the patellar tendon in one patient, one case of peri-prosthesis fracture, two iatrogenic avulsion fractures of the anterior tibial tuberosity and seven infections (4 were diagnosed previously).
Resumo:
OBJECTIVE: assess the functional, subjective and radiological results obtained in patients treated with variable-angle locking plate for unstable distal radius fracture and compare these results with current studies. PATIENTS AND METHOD: From October of 2008 to July of 2011, 20 patients were included who had undergone intervention using the volar approach to the Flexor Carpi Radialis. The average follow up was 18 months. Both clinical and radiological results were analyzed. The Mayo Wrist Score and DASH questioner were used. RESULTS: The average age was 50 years; 50% men and 50% women. The consolidation of the fracture was verified in all cases. An average volar angle was obtained of 5º, radial inclination of 19º, radial height of 10.5 mm, and ulnar variance of -1 mm. The clinical assessment revealed an average dorsal flexion of 75º, palm flexion of 70º, supination of 75º and pronation of 73 º. The results for the DASH questionnaire showed an average of 17.8 and 82.7 for the Mayo Wrist Score. CONCLUSIONS: Our experience has provided some good results, both in functional and subjective as well as radio logical terms, similar to those found in studies with implants from the same generation.
Resumo:
Objective: Evaluate the results obtained in the simultaneous replacement of a septic arthroplasty or a second septic replacement (implanting the prosthesis in a contaminated eld). Material and method: Series of 17 cases, with a mean age of 66.8 years and average follow-up of 49 months. The exclusion criteria were serious immunological depression and unknown germ or not sensitive to at least three antibiotics. After the intervention, the corresponding antibiotics were administered between six weeks and three months. Recovery was established as the normality for infection indicator variables at least nine months after the replacement. Results: 14 patients developed towards total recovery (follow-up at least 9 months and maximum 84 months). 3 cases presented relapse, all three carriers of Staphylococcus epidermidis (at 1, 3 and 7 months of follow-up respectively). The success percentage is 82.41% (average follow-up of 49 months). Conclusions: Simultaneous replacements is an interesting option for patients with plural pathologies as it o"ers a single operation, less morbidity, quicker return to activities to restore normal function and less associated costs