3 resultados para Placa de incubação
Resumo:
INTRODUCTION: The femoral periprosthetic fracture of the knee is one of the most feared complications because of its repercussions. Incidence are more and more likely due to the increase of total implanted arthroplasty of the knee, due to the increasing lifespan among the general population. The objective of this study is to analyze some of the perioperative aspects of the treatment of these fractures, comparing the use of osteosynthesis with plates and the retrograde nailing in those patients with femoral periprosthetic knee fractures with a stable implant. MATERIAL AND METODS: The study retrospectively examines 18 cases treated consecutively in our hospital (3 men and 15 women, average age of 72.7 years) between the years of 2000 and 2009. All fractures were located in the distal femur and on a stable implant. Eight were treated through retrograde nailing (Group I) and ten with plates (Group II). The cases are analyzed through the tests of the University of Mann-Withney and the exact Fischer test, with significant values of p≤0.05, the variables of median hospital stay, necessity of transfusion indicated with values of hemoglobin less than 8 mg/ml, preoperative radiological alignment and postoperative alignment of the total knee prosthesis (TKR), measured following the anatomical tibiofemoral axis, time of consolidation and incidence of localized complications in both groups. RESULTS: We did not find any statistically significant differences between the two groups in any of the variables analyzed. Localized complications are more frequent in Group I (62.5 percent of patients) than in Group II (10 percent of patients). The need for transfusion is greater in Group II (40 percent) than in Group I (12.5 percent). CONCLUSIONS: The type of implant used in treatment of femoral periprosthetic knee fracture does not significantly influence perioperative factors. The treatment for this type of fractures should be individually chosen in relation to the type of fracture, characteristics of the patient and stability and prosthesis model of the primary knee.
Resumo:
OBJECTIVE: assess the functional, subjective and radiological results obtained in patients treated with variable-angle locking plate for unstable distal radius fracture and compare these results with current studies. PATIENTS AND METHOD: From October of 2008 to July of 2011, 20 patients were included who had undergone intervention using the volar approach to the Flexor Carpi Radialis. The average follow up was 18 months. Both clinical and radiological results were analyzed. The Mayo Wrist Score and DASH questioner were used. RESULTS: The average age was 50 years; 50% men and 50% women. The consolidation of the fracture was verified in all cases. An average volar angle was obtained of 5º, radial inclination of 19º, radial height of 10.5 mm, and ulnar variance of -1 mm. The clinical assessment revealed an average dorsal flexion of 75º, palm flexion of 70º, supination of 75º and pronation of 73 º. The results for the DASH questionnaire showed an average of 17.8 and 82.7 for the Mayo Wrist Score. CONCLUSIONS: Our experience has provided some good results, both in functional and subjective as well as radio logical terms, similar to those found in studies with implants from the same generation.
Resumo:
Hemeoxygenase-2 (HO-2) is an antioxidant enzyme that can modulate recombinant maxi-K(+) channels and has been proposed to be the acute O(2) sensor in the carotid body (CB). We have tested the physiological contribution of this enzyme to O(2) sensing using HO-2 null mice. HO-2 deficiency leads to a CB phenotype characterized by organ growth and alteration in the expression of stress-dependent genes, including the maxi-K(+) channel alpha-subunit. However, sensitivity to hypoxia of CB is remarkably similar in HO-2 null animals and their control littermates. Moreover, the response to hypoxia in mouse and rat CB cells was maintained after blockade of maxi-K(+) channels with iberiotoxin. Hypoxia responsiveness of the adrenal medulla (AM) (another acutely responding O(2)-sensitive organ) was also unaltered by HO-2 deficiency. Our data suggest that redox disregulation resulting from HO-2 deficiency affects maxi-K(+) channel gene expression but it does not alter the intrinsic O(2) sensitivity of CB or AM cells. Therefore, HO-2 is not a universally used acute O(2) sensor.