3 resultados para Brake Fluid.
Resumo:
INTRODUCTION The objectives were to characterize alveolar fluid clearance (AFC) in pigs with normal lungs and to analyze the effect of immediate application of positive end-expiratory pressure (PEEP). METHODS Animals (n = 25) were mechanically ventilated and divided into four groups: small edema (SE) group, producing pulmonary edema (PE) by intratracheal instillation of 4 ml/kg of saline solution; small edema with PEEP (SE + PEEP) group, same as previous but applying PEEP of 10 cmH2O; large edema (LE) group, producing PE by instillation of 10 ml/kg of saline solution; and large edema with PEEP (LE + PEEP) group, same as LE group but applying PEEP of 10 cmH2O. AFC was estimated from differences in extravascular lung water values obtained by transpulmonary thermodilution method. RESULTS At one hour, AFC was 19.4% in SE group and 18.0% in LE group. In the SE + PEEP group, the AFC rate was higher at one hour than at subsequent time points and higher than in the SE group (45.4% vs. 19.4% at one hour, P < 0.05). The AFC rate was also significantly higher in the LE + PEEP than in the LE group at three hours and four hours. CONCLUSIONS In this pig model, the AFC rate is around 20% at one hour and around 50% at four hours, regardless of the amount of edema, and is increased by the application of PEEP.
Resumo:
INTRODUCTION Although several parameters have been proposed to predict the hemodynamic response to fluid expansion in critically ill patients, most of them are invasive or require the use of special monitoring devices. The aim of this study is to determine whether noninvasive evaluation of respiratory variation of brachial artery peak velocity flow measured using Doppler ultrasound could predict fluid responsiveness in mechanically ventilated patients. METHODS We conducted a prospective clinical research in a 17-bed multidisciplinary ICU and included 38 mechanically ventilated patients for whom fluid administration was planned due to the presence of acute circulatory failure. Volume expansion (VE) was performed with 500 mL of a synthetic colloid. Patients were classified as responders if stroke volume index (SVi) increased >or= 15% after VE. The respiratory variation in Vpeakbrach (DeltaVpeakbrach) was calculated as the difference between maximum and minimum values of Vpeakbrach over a single respiratory cycle, divided by the mean of the two values and expressed as a percentage. Radial arterial pressure variation (DeltaPPrad) and stroke volume variation measured using the FloTrac/Vigileo system (DeltaSVVigileo), were also calculated. RESULTS VE increased SVi by >or= 15% in 19 patients (responders). At baseline, DeltaVpeakbrach, DeltaPPrad and DeltaSVVigileo were significantly higher in responder than nonresponder patients [14 vs 8%; 18 vs. 5%; 13 vs 8%; P < 0.0001, respectively). A DeltaVpeakbrach value >10% predicted fluid responsiveness with a sensitivity of 74% and a specificity of 95%. A DeltaPPrad value >10% and a DeltaSVVigileo >11% predicted volume responsiveness with a sensitivity of 95% and 79%, and a specificity of 95% and 89%, respectively. CONCLUSIONS Respiratory variations in brachial artery peak velocity could be a feasible tool for the noninvasive assessment of fluid responsiveness in patients with mechanical ventilatory support and acute circulatory failure. TRIAL REGISTRATION ClinicalTrials.gov ID: NCT00890071.
Resumo:
Iodine deficiency is an important clinical and public health problem. Its prevention begins with an adequate intake of iodine during pregnancy. International agencies recommend at least 200 microg iodine per d for pregnant women. We assessed whether iodine concentrations in the amniotic fluid of healthy pregnant women are independent of iodine intake. This cross-sectional, non-interventional study included 365 consecutive women who underwent amniocentesis to determine the fetal karyotype. The amniocentesis was performed with abdominal antisepsis using chlorhexidine. The iodine concentration was measured in urine and amniotic fluid. The study variables were the intake of iodized salt and multivitamin supplements or the prescription of a KI supplement. The mean level of urinary iodine was 139.0 (SD 94.5) microg/l and of amniotic fluid 15.81 (SD 7.09) microg/l. The women who consumed iodized salt and those who took a KI supplement had significantly higher levels of urinary iodine than those who did not (P = 0.01 and P = 0.004, respectively). The urinary iodine levels were not significantly different in the women who took a multivitamin supplement compared with those who did not take this supplement, independently of iodine concentration or multivitamin supplement. The concentrations of iodine in the amniotic fluid were similar, independent of the dietary iodine intake. Urine and amniotic fluid iodine concentrations were weakly correlated, although the amniotic fluid values were no higher in those women taking a KI supplement. KI prescription at recommended doses increases the iodine levels in the mother without influencing the iodine levels in the amniotic fluid.