19 resultados para valve replacement repair

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Due to the high prevalence of renal failure in transcatheter aortic valve replacement (TAVR) candidates, a non-contrast MR technique is desirable for pre-procedural planning. We sought to evaluate the feasibility of a novel, non-contrast, free-breathing, self-navigated three-dimensional (SN3D) MR sequence for imaging the aorta from its root to the iliofemoral run-off in comparison to non-contrast two-dimensional-balanced steady-state free-precession (2D-bSSFP) imaging. METHODS: SN3D [field of view (FOV), 220-370 mm(3); slice thickness, 1.15 mm; repetition/echo time (TR/TE), 3.1/1.5 ms; and flip angle, 115°] and 2D-bSSFP acquisitions (FOV, 340 mm; slice thickness, 6 mm; TR/TE, 2.3/1.1 ms; flip angle, 77°) were performed in 10 healthy subjects (all male; mean age, 30.3 ± 4.3 yrs) using a 1.5-T MRI system. Aortic root measurements and qualitative image ratings (four-point Likert-scale) were compared. RESULTS: The mean effective aortic annulus diameter was similar for 2D-bSSFP and SN3D (26.7 ± 0.7 vs. 26.1 ± 0.9 mm, p = 0.23). The mean image quality of 2D-bSSFP (4; IQR 3-4) was rated slightly higher (p = 0.03) than SN3D (3; IQR 2-4). The mean total acquisition time for SN3D imaging was 12.8 ± 2.4 min. CONCLUSIONS: Our results suggest that a novel SN3D sequence allows rapid, free-breathing assessment of the aortic root and the aortoiliofemoral system without administration of contrast medium. KEY POINTS: • The prevalence of renal failure is high among TAVR candidates. • Non-contrast 3D MR angiography allows for TAVR procedure planning. • The self-navigated sequence provides a significantly reduced scanning time.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We reviewed our surgery registry, to identify predictive risk factors for operative results, and to analyse the long-term survival outcome in octogenarians operated for primary isolated aortic valve replacement (AVR). A total of 124 consecutive octogenarians underwent open AVR from January 1990 to December 2005. Combined procedures and redo surgery were excluded. Selected variables were studied as risk factors for hospital mortality and early neurological events. A follow-up (FU; mean FU time: 77 months) was obtained (90% complete), and Kaplan-Meier plots were used to determine survival rates. The mean age was 82+/-2.2 (range: 80-90 years; 63% females). Of the group, four patients (3%) required urgent procedures, 10 (8%) had a previous myocardial infarction, six (5%) had a previous coronary angioplasty and stenting, 13 patients (10%) suffered from angina and 59 (48%) were in the New York Heart Association (NYHA) class III-IV. We identified 114 (92%) degenerative stenosis, six (5%) post-rheumatic stenosis and four (3%) active endocarditis. The predicted mortality calculated by logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) was 12.6+/-5.7%, and the observed hospital mortality was 5.6%. Causes of death included severe cardiac failure (four patients), multi-organ failure (two) and sepsis (one). Complications were transitory neurological events in three patients (2%), short-term haemodialysis in three (2%), atrial fibrillation in 60 (48%) and six patients were re-operated for bleeding. Atrio-ventricular block, myocardial infarction or permanent stroke was not detected. The age at surgery and the postoperative renal failure were predictors for hospital mortality (p value <0.05), whereas we did not find predictors for neurological events. The mean FU time was 77 months (6.5 years) and the mean age of surviving patients was 87+/-4 years (81-95 years). The actuarial survival estimates at 5 and 10 years were 88% and 50%, respectively. Our experience shows good short-term results after primary isolated standard AVR in patients more than 80 years of age. The FU suggests that aortic valve surgery in octogenarians guarantees satisfactory long-term survival rates and a good quality of life, free from cardiac re-operations. In the era of catheter-based aortic valve implantation, open-heart surgery for AVR remains the standard of care for healthy octogenarians.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

GOAL: To evaluate the impact of the Ross operation, recently (1997) introduced in our unit, for the treatment of patients with congenital aortic valve stenosis. METHODS: The period from January 1997 to December 2000 was compared with the previous 5 years (1992-96). Thirty-seven children (< 16 yrs) and 49 young adults (16-50 yrs) with congenital aortic valve stenosis underwent one of these treatments: percutaneous balloon dilatation (PBD), aortic valve commissurotomy, aortic valve replacement and the Ross operation. The Ross operation was performed in 16 patients, mean age 24.5 yrs (range 9-46 yrs) with a bicuspid stenotic aortic valve, 7/10 adults with calcifications, 2/10 adults with previous aortic valve commissurotomy, 4/6 children with aortic regurgitation following PBD, and 1/6 children who had had a previous aortic valve replacement with a prosthetic valve and aortic root enlargement. RESULTS: PBD was followed by death in two neonates (fibroelastosis); all other children survived PBD. Although there were no deaths, PBD in adults was recently abandoned, owing to unfavourable results. Aortic valve commissurotomy showed good results in children (no deaths). Aortic valve replacement, although associated with good results (no deaths), has been recently abandoned in children in favour of the Ross operation. Over a mean follow-up of 16 months (2-40 months) all patients are asymptomatic following Ross operation, with no echocardiographic evidence of aortic valve regurgitation in 10/16 patients and with trivial regurgitation in 6/16 patients. CONCLUSIONS: The approach now for children and young adults with congenital aortic valve stenosis should be as follows: (1) PBD is the first choice in neonates and infants; (2) Aortic valve commissurotomy is the first choice for children, neonates and infants after failed PBD; (3) The Ross operation is increasingly used in children after failed PBD and in young adults, even with a calcified aortic valve.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The trans-apical aortic valve implantation (TA-AVI) is an established technique for high-risk patients requiring aortic valve replacement. Traditionally, preoperative (computed tomography (CT) scan, coronary angiogram) and intra-operative imaging (fluoroscopy) for stent-valve positioning and implantation require contrast medium injections. To preserve the renal function in elderly patients suffering from chronic renal insufficiency, a fully echo-guided trans-catheter valve implantation seems to be a reasonable alternative. We report the first successful TA-AVI procedure performed solely under trans-oesophageal echocardiogram control, in the absence of contrast medium injections.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Mitral regurgitation (MR) involves systolic retrograde flow from the left ventricle into the left atrium. While trivial MR is frequent in healthy subjects, moderate to severe MR constitutes the second most prevalent valve disease after aortic valve stenosis. Major causes of severe MR in Western countries include degenerative valve disease (myxomatous disease, flail leaflet, annular calcification) and ischaemic heart disease, while rheumatic disease remains a major cause of MR in developing countries. Chronic MR typically progresses insidiously over many years. Once established, however, severe MR portends a poor prognosis. The severity of MR can be assessed by various techniques, Doppler echocardiography being the most widely used. Mitral valve surgery is the only treatment of proven efficacy. It alleviates clinical symptoms and prevents ventricular dilatation and heart failure (or, at least, it attenuates further progression of these abnormalities). Valve repair significantly improves clinical outcomes compared with valve replacement, reducing mortality by approximately 70%. Reverse LV remodelling after valve repair occurs in half of patients with functional MR. Percutaneous, catheter-based to mitral valve repair is a novel approach currently under clinical scrutiny, with encouraging preliminary results. This modality may provide a valuable alternative to mitral valve surgery, especially in critically ill patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients who develop a severe stenosis in biological pulmonary conduits previously implanted for pulmonary outflow trunk reconstructions are treated either by surgical re-replacement, or by transcatheter stent-valve implantation through a femoral vein access. A catheter-based sub-xyphoidian access through the right ventricle for stent-valve positioning in a pulmonary conduit has rarely been proposed. We describe the case of a 20-year-old man who underwent a pulmonary trunk reconstruction for a congenital pulmonary valve dysplasia and a few years later developed a stenosis in the pulmonary conduit. He was successfully treated with a 23 mm Edwards Sapien stent-valve implantation in pulmonary position, through an unusual right ventricular, sub-xyphoidian access and without contrast medium injections and pleura opening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients with Ebstein's anomaly can present after childhood or adolescence with cyanosis, arrhythmias, severe right ventricular dysfunction and frequently with left ventricular dysfunction secondary to the prolonged cyanosis and to the right ventricular interference. At this point conventional repair is accompanied by elevated mortality and morbidity and poor functional results. We report our experience with three patients (8, 16 and 35 years of age) with Ebstein's anomaly, very dilated right atrium, severe tricuspid valve regurgitation (4/4), bi-directional shunt through an atrial septal defect and reduced left ventricular function (mean ejection fraction = 58%, mean shortening fraction = 25%). All underwent one and a half ventricular repair consisting of closure of the atrial septal defect, tricuspid repair with reduction of the atrialised portion of the right ventricle and end-to-side anastomosis of the superior vena cava to the right pulmonary artery. All patients survived, with a mean follow-up of 33 months. In all there was complete regression of the cyanosis and of the signs of heart failure. Postoperative echocardiography showed reduced degree of tricuspid regurgitation (2/4) and improvement of the left ventricular function (mean ejection fraction = 77%, mean shortening fraction = 40%). In patients with Ebstein's anomaly referred late for surgery with severely compromised right ventricular function or even with reduced biventricular function, the presence of a relatively hypoplastic and/or malfunctioning right ventricular chamber inadequate to sustain the entire systemic venous return but capable of managing part of the systemic venous return, permits a one and a half ventricular repair with good functional results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Several scores are commonly used to evaluate patients' postoperative satisfaction after lateral ankle ligament repair, including: AOFAS, FAAM, CAIT and CAIS. Comparing published studies in the literature is difficult, as the same patient can have markedly different results depending on which scoring system is used. The current study aims to address this gap in the literature by developing a system to compare these tests, to allow better analysis and comparison of published studies. Patients and methods: This is a retrospective cohort study of 47 patients following lateral ankle ligament repair using a modified Broström-Gould technique. All patients were operated between 2005 and 2010 by a single surgeon and followed the same post operative rehabilitation protocol. Six patients were excluded from the study because of concomitant surgery. Patients were assessed by an independent observer. We used the Pearson correlation coefficient to analyse the concordance of the scores, as well as scatter plots to assess the linear relationship between them. Results: A linear distribution between the scores was found when the results were analysed using scatter plots. We were thus able to use the Pearson correlation coefficient to evaluate the relationship between each of the different postoperative scores. The correlation was found to be above 0.5 in all cases except for the comparison between the CAIT and the FAAM for the activities of daily living (0.39). We were, therefore, able to compare the results obtained and assess the relative concordance of the scoring systems. The results showed that the more specific the scale is, the worst the score is and inversely. So the CAIT and the CAIS appeared to be more severe than the AOFAS and the FAAM measuring the activities of daily living. The sports subscale of the FAAM demonstrated intermediate results. Conclusion: This study outlines a system to compare different postoperative scores commonly used to evaluate outcome after ankle stabilization surgery. The impact of this study is that it makes comparison of published studies easier, even though they use a variety of different clinical scores, thus facilitating better outcome analysis of operative techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human MRE11 is a key enzyme in DNA double-strand break repair and genome stability. Human MRE11 bears a glycine-arginine-rich (GAR) motif that is conserved among multicellular eukaryotic species. We investigated how this motif influences MRE11 function. Human MRE11 alone or a complex of MRE11, RAD50, and NBS1 (MRN) was methylated in insect cells, suggesting that this modification is conserved during evolution. We demonstrate that PRMT1 interacts with MRE11 but not with the MRN complex, suggesting that MRE11 arginine methylation occurs prior to the binding of NBS1 and RAD50. Moreover, the first six methylated arginines are essential for the regulation of MRE11 DNA binding and nuclease activity. The inhibition of arginine methylation leads to a reduction in MRE11 and RAD51 focus formation on a unique double-strand break in vivo. Furthermore, the MRE11-methylated GAR domain is sufficient for its targeting to DNA damage foci and colocalization with gamma-H2AX. These studies highlight an important role for the GAR domain in regulating MRE11 function at the biochemical and cellular levels during DNA double-strand break repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. METHODS AND RESULTS: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. CONCLUSION: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral nerve injury is a serious problem affecting significantly patients' life. Autografts are the "gold standard" used to repair the injury gap, however, only 50% of patients fully recover from the trauma. Artificial conduits are a valid alternative to repairing peripheral nerve. They aim at confining the nerve environment throughout the regeneration process, and providing guidance to axon outgrowth. Biocompatible materials have been carefully designed to reduce inflammation and scar tissue formation, but modifications of the inner lumen are still required in order to optimise the scaffolds. Biomicking the native neural tissue with extracellular matrix fillers or coatings showed great promises in repairing longer gaps and extending cell survival. In addition, extracellular matrix molecules provide a platform to further bind growth factors that can be released in the system over time. Alternatively, conduit fillers can be used for cell transplantation at the injury site, reducing the lag time required for endogenous Schwann cells to proliferate and take part in the regeneration process. This review provides an overview on the importance of extracellular matrix molecules in peripheral nerve repair.