19 resultados para ultrafiltration.

em Université de Lausanne, Switzerland


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: To date, there is no quality assurance program that correlates patient outcome to perfusion service provided during cardiopulmonary bypass (CPB). A score was devised, incorporating objective parameters that would reflect the likelihood to influence patient outcome. The purpose was to create a new method for evaluating the quality of care the perfusionist provides during CPB procedures and to deduce whether it predicts patient morbidity and mortality. METHODS: We analysed 295 consecutive elective patients. We chose 10 parameters: fluid balance, blood transfused, Hct, ACT, PaO2, PaCO2, pH, BE, potassium and CPB time. Distribution analysis was performed using the Shapiro-Wilcoxon test. This made up the PerfSCORE and we tried to find a correlation to mortality rate, patient stay in the ICU and length of mechanical ventilation. Univariate analysis (UA) using linear regression was established for each parameter. Statistical significance was established when p < 0.05. Multivariate analysis (MA) was performed with the same parameters. RESULTS: The mean age was 63.8 +/- 12.6 years with 70% males. There were 180 CABG, 88 valves, and 27 combined CABG/valve procedures. The PerfSCORE of 6.6 +/- 2.4 (0-20), mortality of 2.7% (8/295), CPB time 100 +/- 41 min (19-313), ICU stay 52 +/- 62 hrs (7-564) and mechanical ventilation of 10.5 +/- 14.8 hrs (0-564) was calculated. CPB time, fluid balance, PaO2, PerfSCORE and blood transfused were significantly correlated to mortality (UA, p < 0.05). Also, CPB time, blood transfused and PaO2 were parameters predicting mortality (MA, p < 0.01). Only pH was significantly correlated for predicting ICU stay (UA). Ultrafiltration (UF) and CPB time were significantly correlated (UA, p < 0.01) while UF (p < 0.05) was the only parameter predicting mechanical ventilation duration (MA). CONCLUSIONS: CPB time, blood transfused and PaO2 are independent risk factors of mortality. Fluid balance, blood transfusion, PaO2, PerfSCORE and CPB time are independent parameters for predicting morbidity. PerfSCORE is a quality of perfusion measure that objectively quantifies perfusion performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate whether respiratory acidosis modulates ventilator-induced lung injury (VILI), we perfused (constant flow) 21 isolated sets of normal rabbit lungs, ventilated them for 20 min (pressure controlled ventilation [PCV] = 15 cm H(2)O) (Baseline) with an inspired CO(2) fraction adjusted for the partial pressure of CO(2) in the perfusate (PCO(2) approximately equal to 40 mm Hg), and then randomized them into three groups. Group A (control: n = 7) was ventilated with PCV = 15 cm H(2)O for three consecutive 20-min periods (T1, T2, T3). In Group B (high PCV/normocapnia; n = 7), PCV was given at 20 (T1), 25 (T2), and 30 (T3) cm H(2)O. The targeted PCO(2) was 40 mm Hg in Groups A and B. Group C (high PCV/hypercapnia; n = 7) was ventilated in the same way as Group B, but the targeted PCO(2) was approximately equal to 70 to 100 mm Hg. The changes (from Baseline to T3) in weight gain (Delta WG: g) and in the ultrafiltration coefficient (Delta K(f) = gr/min/ cm H(2)O/100g) and the protein and hemoglobin concentrations in bronchoalveolar lavage fluid (BALF) were used to assess injury. Group B experienced a significantly greater Delta WG (14.85 +/- 5.49 [mean +/- SEM] g) and Delta K(f) (1.40 +/- 0.49 g/min/cm H(2)O/100 g) than did either Group A (Delta WG = 0.70 +/- 0.43; Delta K(f) = 0.01 +/- 0.03) or Group C (Delta WG = 5.27 +/- 2.03 g; Delta K(f) = 0.25 +/- 0.12 g/min/cm H(2)O/ 100 g). BALF protein and hemoglobin concentrations (g/L) were higher in Group B (11.98 +/- 3.78 g/L and 1.82 +/- 0.40 g/L, respectively) than in Group A (2.92 +/- 0.75 g/L and 0.38 +/- 0.15 g/L) or Group C (5.71 +/- 1.88 g/L and 1.19 +/- 0.32 g/L). We conclude that respiratory acidosis decreases the severity of VILI in this model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has been suggested that an inappropriate relationship between renin and exchangeable sodium is responsible for the hypertension of patients with chronic renal failure. Long-term blockade of the renin system by captopril made it possible to test this hypothesis in 8 patients on maintenance hemodialysis. Captopril was administered orally in 2 daily doses of 25 to 200 mg. Previously, blood pressure averaged 179/105 +/- 6/3 (mean +/- SEM) pre- and 182/103 +/- 7/3 mm HG post-dialysis, despite intensive ultrafiltration and conventional antihypertensive therapy. The 4 patients with the highest plasma renin activity normalized their blood pressure with captopril alone, whereas in the 4 remaining patients, captopril therapy was complemented by salt subtraction which consisted in replacement of 1-2 liters of ultrafiltrate by an equal volume of 5% dextrose until blood pressure was controlled. After an average treatment period of 5 months, blood pressure of all 8 patients was reduced to 134/76 +/- 7/5 mm Hg (P less than 0.001) pre- and 144/81 +/- 9/5 mm Hg (P less than 0.001) post-dialysis without a significant change in body weight. The present data suggest that captopril alone or combined with salt subtraction normalizes blood pressure of patients on chronic hemodialysis with so called uncontrollable hypertension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The process of on-line generation of ultrapure dialysis fluid is a core prerequisite for the safe execution of modern renal replacement therapies such as on-line hemodiafiltration and high-flux hemodialysis. In these extracorporeal treatments with variable degrees of convection, significant volumes of plasma water are removed and replaced with dialysis fluid, which must occur without causing harm to the patient. Historically, on-line generation of sterile and pyrogen-free physiological substitution fluid by the process of membrane ultrafiltration of fresh dialysis fluid has its origin in hemofiltration, a purely convective therapy. Development of this and later therapies is described in the historical context of a successful effort over decades to overcome the above formidable challenge, which was provided jointly by pioneering clinical investigators and a resourceful dialysis industry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Colloidal transport has been shown to enhance the migration of plutonium in groundwater downstream from contaminated sites, but little is known about the adsorption of ⁹⁰Sr and plutonium onto colloids in the soil solution of natural soils. We sampled soil solutions using suction cups, and separated colloids using ultrafiltration to determine the distribution of ²³⁹Pu and ⁹⁰Sr between the truly dissolved fraction and the colloidal fraction of the solutions of three Alpine soils contaminated only by global fallout from the nuclear weapon tests. Plutonium was essentially found in the colloidal fraction (>80%) and probably associated with organic matter. A significant amount of colloidal ⁹⁰Sr was detected in organic-rich soil solutions. Our results suggest that binding to organic colloids in the soil solutions plays a key role with respect to the mobility of plutonium in natural alpine soils and, to a lesser extent, to the mobility of ⁹⁰Sr.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A generic LC-MS approach for the absolute quantification of undigested peptides in plasma at mid-picomolar levels is described. Nine human peptides namely, brain natriuretic peptide (BNP), substance P (SubP), parathyroid hormone 1-34 (PTH), C-peptide, orexines A and B (Orex-A and -B), oxytocin (Oxy), gonadoliberin-1 (gonadothropin releasing-hormone or luteinizing hormone-releasing hormone, LHRH) and α-melanotropin (α-MSH) were targeted. Plasma samples were extracted via a 2-step procedure: protein precipitation using 1vol of acetonitrile followed by ultrafiltration of supernatants on membranes with a MW cut-off of 30 kDa. By applying a specific LC-MS setup, large volumes of filtrates (e.g., 2×750 μL) were injected and the peptides were trapped on a 1mm i.d.×10 mm length C8 column using a 10× on-line dilution. Then, the peptides were back-flushed and a second on-line dilution (2×) was applied during the transfer step. The refocalized peptides were resolved on a 0.3mm i.d. C18 analytical column. Extraction recovery, matrix effect and limits of detection were evaluated. Our comprehensive protocol demonstrates a simple and efficient sample preparation procedure followed by the analysis of peptides with limits of detection in the mid-picomolar range. This generic approach can be applied for the determination of most therapeutic peptides and possibly for endogenous peptides with latest state-of-the-art instruments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Identification of post-translational modifications of proteins in biological samples often requires access to preanalytical purification and concentration methods. In the purification step high or low molecular weight substances can be removed by size exclusion filters, and high abundant proteins can be removed, or low abundant proteins can be enriched, by specific capturing tools. In this paper is described the experience and results obtained with a recently emerged and easy-to-use affinity purification kit for enrichment of the low amounts of EPO found in urine and plasma specimens. The kit can be used as a pre-step in the EPO doping control procedure, as an alternative to the commonly used ultrafiltration, for detecting aberrantly glycosylated isoforms. The commercially available affinity purification kit contains small disposable anti-EPO monolith columns (6 ?L volume, Ø7 mm, length 0.15 mm) together with all required buffers. A 24-channel vacuum manifold was used for simultaneous processing of samples. The column concentrated EPO from 20 mL urine down to 55 ?L eluate with a concentration factor of 240 times, while roughly 99.7% of non-relevant urine proteins were removed. The recoveries of Neorecormon (epoetin beta), and the EPO analogues Aranesp and Mircera applied to buffer were high, 76%, 67% and 57%, respectively. The recovery of endogenous EPO from human urine was 65%. High recoveries were also obtained when purifying human, mouse and equine EPO from serum, and human EPO from cerebrospinal fluid. Evaluation with the accredited EPO doping control method based on isoelectric focusing (IEF) showed that the affinity purification procedure did not change the isoform distribution for rhEPO, Aranesp, Mircera or endogenous EPO. The kit should be particularly useful for applications in which it is essential to avoid carry-over effects, a problem commonly encountered with conventional particle-based affinity columns. The encouraging results with EPO propose that similar affinity monoliths, with the appropriate antibodies, should constitute useful tools for general applications in sample preparation, not only for doping control of EPO and other hormones such as growth hormone and insulin but also for the study of post-translational modifications of other low abundance proteins in biological and clinical research, and for sample preparation prior to in vitro diagnostics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In 6 hypertensive patients with terminal renal failure maintained on hemodialysis, the effects of 'salt subtraction' and of sequential ultrafiltrating were evaluated. Following each of 3 weekly hemodialysis sessions, salt subtraction was carried out by ultrafiltrating 1 liter and simultaneously infusing an equal volume of 5% dextrose. This resulted in a net sodium loss without hypovolemia. After a 2-week period of this procedure, the blood pressure prior to dialysis was lower (156/76 +/- 12/5 mm Hg) than after a comparable number of sequential ultrafiltration sessions (181/88 +/- 10/6 mm Hg; mean +/- SEM). This difference was not statistically significant. At the same time, body weight was comparable at 64.4 +/- 3 and 64.7 +/- 4 kg, respectively. Neither plasma renin activity nor plasma catecholamines responded with a clear increase to either procedure. The limited effect on blood pressure and the renin system of a marked sodium removal during salt subtraction suggests that sodium must still be present in excess in these patients. The procedure of salt subtraction appears safe and subjectively well tolerated, but it can probably not be used as the sole means of decreasing total body sodium without associating dietary measures to reduce sodium intake.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: To determine the metabolic effect of teriparatide (TPTD) on bone, 99mTc-MDP skeletal plasma clearance was measured in postmenopausal women with osteoporosis treated with TPTD 20 μg/day. Methods: Ten postmenopausal women with osteoporosis had radionuclide bone scans at baseline, 3, and 18 months after starting TPTD 20 μg/day and after 6 months off therapy. Participants were injected with 600 MBq 99mTc- MDP and whole body bone scans acquired at 10 min, 1, 2, 3, and 4 h. Multiple blood samples were taken between 5 min and 4 h and free 99mTc-MDP measured using ultrafiltration. 99mTc-MDP plasma clearance (Kbone) was evaluated using the Patlak plot method. Regional differences in Kbone were studied by measuring the whole skeleton and subregions. Serum procollagen type I Nterminal propeptide (PINP), bone-specific alkaline phosphatase (BSAP), and urinary N-terminal telopeptide (NTX) were measured at each visit.Discussion: The median increase from baseline in whole skeleton Kbone was 22% (P=0.004) at 3 months and 34% (P= 0.002) at 18 months, decreasing to 0.7% after 6 months off therapy. In subregions, Kbone value increases were statistically significant at 3 months and in all subregions except the pelvis at 18 months. After 6 months off therapy, subregional Kbone values also returned toward baseline. Bone markers increases from baseline were statistically significant at 3 and 18 months (BSAP, 15% and 36%; PINP, 137% and 192%; NTX, 109% and 125%). After 6 months off therapy, PINP and NTX values had declined, though remained above baseline (BSAP, −3%; PINP, 43%; NTX, 56%). Increased Kbone values in the whole body and lower extremities were correlated with increases in most bone markers at 3 and 18 months. Increased skeletal uptake of 99mTc-MDP during treatment with TPTD is indicative of increased bone formation and is supported by increases in bone turnover markers.Conclusion: Changes in Kbone and skeletal uptake measured by radionuclide bone scans in patients taking TPTD are the result of metabolic activity of the drug. These data may provide physicians with useful insights when interpreting bone scan results in this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hybridoma cell line ZAC3 expresses Vibrio cholerae lipopolysaccharide (LPS)-specific mouse IgA molecules as a heterogeneous population of monomeric (IgAm), dimeric (IgAd), and polymeric (IgAp) forms. We describe a gentle method combining ultrafiltration, ion-exchange chromatography, and size exclusion chromatography for the simultaneous and qualitative separation of the three molecular forms. Milligram quantities of purified IgA molecules were recovered allowing for direct comparison of the biological properties of the three forms. LPS binding specificity was tested after purification; IgAd and IgAp were found to bind strongly to LPS whereas IgAm did not. Secretory IgA (sIgA) could be reconstituted in vitro by combining recombinant secretory component (rSC) and purified IgAd or IgAp, but not IgAm. Surface plasmon resonance-based binding experiments using LPS monolayers indicated that purified reconstituted sIgA and IgA molecules recognize LPS with identical affinity (KA 1.0 x 10(8)M-1). Thus, this very sensitive assay provides the first evidence that the function of SC in sIgA complex is not to modify the affinity for the antigen. KA falls to 6.6 x 10(5) M-1 when measured by calorimetry using detergent-solubilized LPS and IgA, suggesting that the LPS environment is critical for recognition by the antibody.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While developing a high-pressure liquid chromatography assay for cefepime in plasma, we observed significant drug degradation at 20 and 37 degrees C but not at 4 degrees C. This plasma-related degradation persisted after protein removal. This warrants caution regarding cefepime assays for pharmacokinetic and pharmacodynamic studies of cefepime in vitro and in vivo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient &gt; or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: Total imatinib concentrations are currently measured for the therapeutic drug monitoring of imatinib, whereas only free drug equilibrates with cells for pharmacological action. Due to technical and cost limitations, routine measurement of free concentrations is generally not performed. In this study, free and total imatinib concentrations were measured to establish a model allowing the confident prediction of imatinib free concentrations based on total concentrations and plasma proteins measurements. METHODS: One hundred and fifty total and free plasma concentrations of imatinib were measured in 49 patients with gastrointestinal stromal tumours. A population pharmacokinetic model was built up to characterize mean total and free concentrations with inter-patient and intrapatient variability, while taking into account α1 -acid glycoprotein (AGP) and human serum albumin (HSA) concentrations, in addition to other demographic and environmental covariates. RESULTS: A one compartment model with first order absorption was used to characterize total and free imatinib concentrations. Only AGP influenced imatinib total clearance. Imatinib free concentrations were best predicted using a non-linear binding model to AGP, with a dissociation constant Kd of 319 ng ml(-1) , assuming a 1:1 molar binding ratio. The addition of HSA in the equation did not improve the prediction of imatinib unbound concentrations. CONCLUSION: Although free concentration monitoring is probably more appropriate than total concentrations, it requires an additional ultrafiltration step and sensitive analytical technology, not always available in clinical laboratories. The model proposed might represent a convenient approach to estimate imatinib free concentrations. However, therapeutic ranges for free imatinib concentrations remain to be established before it enters into routine practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Understanding the oxidative reactivity of nanoparticles (NPs; <100 nm) could substantially contribute to explaining their toxicity. We attempted to refine the use of 2′7-dichlorodihydrofluorescein (DCFH) to characterize NP generation of reactive oxygen species (ROS). Several fluorescent probes have been applied to testing oxidative reactivity, but despite DCFH being one of the most popular for the detection of ROS, when it has been applied to NPs there have been an unexplainably wide variability in results. Without a uniform methodology, validating even robust results is impossible. This study, therefore, identified sources of conflicting results and investigated ways of reducing occurrence of artificial results. Existing techniques were tested and combined (using their most desirable features) to form a more reliable method for the measurement of NP reactivity in aqueous dispersions. We also investigated suitable sample ranges necessary to determine generation of ROS. Specifically, ultrafiltration and time-resolved scan absorbance spectra were used to study possible optical interference when using high sample concentrations. Robust results were achieved at a 5 µM DCFH working solution with 0.5 unit/mL horseradish peroxidase (HRP) dissolved in ethanol. Sonication in DCFH-HRP working solution provided more stable data with a relatively clean background. Optimal particle concentration depends on the type of NP and in general was in the µg/mL range. Major reasons for previously reported conflicting results due to interference were different experimental approaches and NP sample concentrations. The protocol presented here could form the basis of a standardized method for applying DCFH to detect generation of ROS by NPs.