136 resultados para smoothing techniques
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND: Obesity is increasing worldwide because developing countries are adopting Western high-fat foods and sedentary lifestyles. In parallel, in many of them, hypertension is rising more rapidly, particularly with age, than in Western countries. OBJECTIVE: To assess the relationship between adiposity and blood pressure (BP) in a developing country with high average BP (The Seychelles, Indian Ocean, population mainly of African origin) in comparison to a developed country with low average BP (Switzerland, population mainly of Caucasian origin). DESIGN: Cross-sectional health examination surveys based on population random samples. SETTING: The main Seychelles island (Mahé) and two Swiss regions (Vaud-Fribourg and Ticino). SUBJECTS: Three thousand one hundred and sixteen adults (age range 35-64) untreated for hypertension. MEASUREMENTS: Body mass index (BMI), waist circumference (WC), waist-to-hip ratio (WHR), systolic and diastolic blood pressure (SBP and DBP, mean of two measures). METHODS: Scatterplot smoothing techniques and gender-specific linear regression models. RESULTS: On average, SBP and DBP were found to increase linearly over the whole variation range of BMI, WHR and WC. A modest, but statistically significant linear association was found between each indicator of adiposity and BP levels in separate regression models controlling for age. The regression coefficients were not significantly different between the Seychelles and the two Swiss regions, but were generally higher in women than in men. For the latter, a gain of 1.7 kg/m(2) in BMI, of 4.5 cm in WC or of 3.4% in WHR corresponded to an elevation of 1 mmHg in SBP. For women, corresponding figures were 1.25 kg/m(2), 2.5 cm and 1.8% respectively. Regression coefficients for age reflected a higher effect of this variable on both SBP and DBP in the Seychelles than in Switzerland. CONCLUSION: These findings suggest a stable linear relation of adiposity with BP, independent of age and body fat distribution, across developed and developing countries. The more rapid increase of BP with age observed in the latter countries are likely to reflect higher genetic susceptibility and/or higher cumulative exposure to another risk factor than adiposity.
Resumo:
BACKGROUND: The prevalence of hyperuricemia has rarely been investigated in developing countries. The purpose of the present study was to investigate the prevalence of hyperuricemia and the association between uric acid levels and the various cardiovascular risk factors in a developing country with high average blood pressures (the Seychelles, Indian Ocean, population mainly of African origin). METHODS: This cross-sectional health examination survey was based on a population random sample from the Seychelles. It included 1011 subjects aged 25 to 64 years. Blood pressure (BP), body mass index (BMI), waist circumference, waist-to-hip ratio, total and HDL cholesterol, serum triglycerides and serum uric acid were measured. Data were analyzed using scatterplot smoothing techniques and gender-specific linear regression models. RESULTS: The prevalence of a serum uric acid level >420 micromol/L in men was 35.2% and the prevalence of a serum uric acid level >360 micromol/L was 8.7% in women. Serum uric acid was strongly related to serum triglycerides in men as well as in women (r = 0.73 in men and r = 0.59 in women, p < 0.001). Uric acid levels were also significantly associated but to a lesser degree with age, BMI, blood pressure, alcohol and the use of antihypertensive therapy. In a regression model, triglycerides, age, BMI, antihypertensive therapy and alcohol consumption accounted for about 50% (R2) of the serum uric acid variations in men as well as in women. CONCLUSIONS: This study shows that the prevalence of hyperuricemia can be high in a developing country such as the Seychelles. Besides alcohol consumption and the use of antihypertensive therapy, mainly diuretics, serum uric acid is markedly associated with parameters of the metabolic syndrome, in particular serum triglycerides. Considering the growing incidence of obesity and metabolic syndrome worldwide and the potential link between hyperuricemia and cardiovascular complications, more emphasis should be put on the evolving prevalence of hyperuricemia in developing countries.
Resumo:
Reconstructive surgery takes an important place in breast cancer treatment. Immediate breast reconstruction is performed during the same operation as mastectomy. It is contraindicated following radiotherapy. Reconstruction performed after mastectomy is called differed breast reconstruction. It is completed 6 months after chemotherapy and 1 year after radiotherapy. Prosthetic breast reconstruction is indicated when tissues are of good qualities and breast are small. Autologous reconstruction is performed in case of radiotherapy or large breast. After breast reconstruction, imperfections can be corrected with autologous fat injection.
Resumo:
Forensic scientists have long detected the presence of drugs and their metabolites in biological materials using body fluids such as urine, blood and/or other biological liquids or tissues. For doping analysis, only urine has so far been collected. In recent years, remarkable advances in sensitive analytical techniques have encouraged the analysis of drugs in unconventional biological samples such as hair, saliva and sweat. These samples are easily collected, although drug levels are often lower than the corresponding levels in urine or blood. This chapter reviews recent studies in the detection of doping agents in hair, saliva and sweat. Sampling, analytical procedures and interpretation of the results are discussed in comparison with those obtained from urine and blood samples.
Resumo:
Neuroimaging techniques provide valuable tools for diagnosing Alzheimer's disease (AD), monitoring disease progression and evaluating responses to treatment. There is currently a wide array of techniques available including computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), and, for recording electrical brain activity, electroencephalography (EEG). The choice of technique depends on the contrast between tissues of interest, spatial resolution, temporal resolution, requirements for functional data and the probable number of scans required. For example, while PET, CT and MRI can be used to differentiate between AD and other dementias, MRI is safer and provides better contrast of soft tissues. Neuroimaging is a technique spanning many disciplines and requires effective communication between doctors requesting a scan of a patient or group of patients and those with technical expertise. Consideration and discussion of the most suitable type of scan and the necessary settings to achieve the best results will help ensure appropriate techniques are chosen and used effectively. Neuroimaging techniques are currently expanding understanding of the structural and functional changes that occur in dementia. Further research may allow identification of early neurological signs ofAD, before clinical symptoms are evident, providing the opportunity to test preventative therapies. CombiningMRI and machine learning techniques may be a powerful approach to improve diagnosis ofAD and to predict clinical outcomes.
Resumo:
Insight into the function of sleep may be gained by studying animals in the ecological context in which sleep evolved. Until recently, technological constraints prevented electroencephalogram (EEG) studies of animals sleeping in the wild. However, the recent development of a small recorder (Neurologger 2) that animals can carry on their head permitted the first recordings of sleep in nature. To facilitate sleep studies in the field and to improve the welfare of experimental animals, herein, we test the feasibility of using minimally invasive surface and subcutaneous electrodes to record the EEG in barn owls. The EEG and behaviour of four adult owls in captivity and of four chicks in a nest box in the field were recorded. We scored a 24-h period for each adult bird for wakefulness, slow-wave sleep (SWS), and rapid-eye movement (REM) sleep using 4 s epochs. Although the quality and stability of the EEG signals recorded via subcutaneous electrodes were higher when compared to surface electrodes, the owls' state was readily identifiable using either electrode type. On average, the four adult owls spent 13.28 h awake, 9.64 h in SWS, and 1.05 h in REM sleep. We demonstrate that minimally invasive methods can be used to measure EEG-defined wakefulness, SWS, and REM sleep in owls and probably other animals.
Resumo:
Purpose: To investigate the effect of the systematized use of intraluminal stents in Baerveldt shunts (BS) on early postoperative IOP control and complication rates. Methods: One hundred and twenty eyes with medically uncontrolled glaucoma were prospectively recruited to undergo BS implantation at Jules Gonin Eye Hospital, Switzerland. Baerveldt shunts were stented (full-length of the intraluminal tube) using a Supramid® 3.0 suture. A minority of shunts (37%) were also ligated intraoperatively and laser suture lysis performed postoperatively. Stent removals, either partial (retraction of 5mm) or complete, were carried out according to a predetermined protocol. Surgery was considered a success when IOP was ≤ 21mmHg and a minimum of 20% reduction from baseline was achieved with/without glaucoma medication (GMs). Hypotony related complications were defined as: choroidal effusions, shallow AC, hypotonous maculopathy or IOP≤5mmHg for over 2 weeks. Results: Mean age was 61.8 years (± standard deviation; ±21.5). Mean follow-up was 17.1 (±7.9) months. Mean preoperative IOP was 26.9 mmHg; mean IOP on the last visit 13.2 mmHg (p<0.001). At year one, the success rate was 87%. In 90% of eyes, IOP was ≤18 mmHg at last visit. Mean number of preoperatively GMs was 3.1; postoperatively 1.4 (p<0.001). Stent removals were performed in 87% of eyes (24% partial; 61% complete). 13% of eyes required no stent removal to reach target IOP. Complications were minor and infrequent (16%) and only 7% were hypotony related. Conclusions: Systematized use of intraluminal stents with Baerveldt aqueous shunts resulted in gradual and controlled IOP lowering with minimal hypotony-related complications. This may have important implications on clinical practice, given the rising rates of aqueous shunt implantation.
Resumo:
OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.