5 resultados para measures of association

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Attrition in longitudinal studies can lead to biased results. The study is motivated by the unexpected observation that alcohol consumption decreased despite increased availability, which may be due to sample attrition of heavy drinkers. Several imputation methods have been proposed, but rarely compared in longitudinal studies of alcohol consumption. The imputation of consumption level measurements is computationally particularly challenging due to alcohol consumption being a semi-continuous variable (dichotomous drinking status and continuous volume among drinkers), and the non-normality of data in the continuous part. Data come from a longitudinal study in Denmark with four waves (2003-2006) and 1771 individuals at baseline. Five techniques for missing data are compared: Last value carried forward (LVCF) was used as a single, and Hotdeck, Heckman modelling, multivariate imputation by chained equations (MICE), and a Bayesian approach as multiple imputation methods. Predictive mean matching was used to account for non-normality, where instead of imputing regression estimates, "real" observed values from similar cases are imputed. Methods were also compared by means of a simulated dataset. The simulation showed that the Bayesian approach yielded the most unbiased estimates for imputation. The finding of no increase in consumption levels despite a higher availability remained unaltered. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Summary : 1. Measuring health literacy in Switzerland: a review of six surveys: 1.1 Comparison of questionnaires - 1.2 Measures of health literacy in Switzerland - 1.3 Discussion of Swiss data on HL - 1.4 Description of the six surveys: 1.4.1 Current health trends and health literacy in the Swiss population (gfs-UNIVOX), 1.4.2 Nutrition, physical exercise and body weight : opinions and perceptions of the Swiss population (USI), 1.4.3 Health Literacy in Switzerland (ISPMZ), 1.4.4 Swiss Health Survey (SHS), 1.4.5 Survey of Health, Ageing and Retirement in Europe (SHARE), 1.4.6 Adult literacy and life skills survey (ALL). - 2 . Economic costs of low health literacy in Switzerland: a rough calculation. Appendix: Screenshots cost model

Relevância:

100.00% 100.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: To examine the association between overweight/obesity and several self-reported chronic diseases, symptoms and disability measures. METHODS: Data from eleven European countries participating in the Survey of Health, Ageing and Retirement in Europe were used. 18,584 non-institutionalised individuals aged 50 years and over with BMI > or = 18.5 (kg/m2) were included. BMI was categorized into normal weight (BMI 18.5-24.9), overweight (BMI 25.0-29.9) and obesity (BMI > or = 30). Dependent variables were 13 diagnosed chronic conditions, 11 health complaints, subjective health and physical disability measures. For both genders, multiple logistic regressions were performed adjusting for age, socioeconomic status and behaviour risks. RESULTS: The odds ratios for high blood pressure, high cholesterol, diabetes, arthritis, joint pain and swollen legs were significantly increased for overweight and obese adults. Compared to normal-weight individuals, the odds ratio (OR) for reporting > or = 2 chronic diseases was 2.4 (95% CI 1.9-2.9) for obese men and 2.7 (95% CI 2.2-3.1) for obese women. Overweight and obese women were more likely to report health symptoms. Obesity in men (OR 0.5, 95% CI 0.4-0.6), and overweight (OR 0.5, 95% CI 0.4-0.6) and obesity (OR 0.4, 95% CI 0.3-0.5) in women, were associated with poorer subjective health (i.e. a decreased risk of reporting excellent, very good or good subjective health). Disability outcomes were those showing the greatest differences in strength of association across BMI categories, and between genders. For example, the OR for any difficulty in walking 100 metres was non-significant at 0.8 for overweight men, at 1.9 (95% CI 1.3-2.7) for obese men, at 1.4 (95% CI 1.1-1.8) for overweight women, and at 3.5 (95% CI 2.6-4.7) for obese women. CONCLUSIONS: These results highlight the impact of increased BMI on morbidity and disability. Healthcare stakeholders of the participating countries should be aware of the substantial burden that obesity places on the general health and autonomy of adults aged over 50.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: LDL cholesterol has a causal role in the development of cardiovascular disease. Improved understanding of the biological mechanisms that underlie the metabolism and regulation of LDL cholesterol might help to identify novel therapeutic targets. We therefore did a genome-wide association study of LDL-cholesterol concentrations. METHODS: We used genome-wide association data from up to 11,685 participants with measures of circulating LDL-cholesterol concentrations across five studies, including data for 293 461 autosomal single nucleotide polymorphisms (SNPs) with a minor allele frequency of 5% or more that passed our quality control criteria. We also used data from a second genome-wide array in up to 4337 participants from three of these five studies, with data for 290,140 SNPs. We did replication studies in two independent populations consisting of up to 4979 participants. Statistical approaches, including meta-analysis and linkage disequilibrium plots, were used to refine association signals; we analysed pooled data from all seven populations to determine the effect of each SNP on variations in circulating LDL-cholesterol concentrations. FINDINGS: In our initial scan, we found two SNPs (rs599839 [p=1.7x10(-15)] and rs4970834 [p=3.0x10(-11)]) that showed genome-wide statistical association with LDL cholesterol at chromosomal locus 1p13.3. The second genome screen found a third statistically associated SNP at the same locus (rs646776 [p=4.3x10(-9)]). Meta-analysis of data from all studies showed an association of SNPs rs599839 (combined p=1.2x10(-33)) and rs646776 (p=4.8x10(-20)) with LDL-cholesterol concentrations. SNPs rs599839 and rs646776 both explained around 1% of the variation in circulating LDL-cholesterol concentrations and were associated with about 15% of an SD change in LDL cholesterol per allele, assuming an SD of 1 mmol/L. INTERPRETATION: We found evidence for a novel locus for LDL cholesterol on chromosome 1p13.3. These results potentially provide insight into the biological mechanisms that underlie the regulation of LDL cholesterol and might help in the discovery of novel therapeutic targets for cardiovascular disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.