287 resultados para catheter ablation
em Université de Lausanne, Switzerland
Resumo:
Multiple organization indices have been used to predict the outcome of stepwise catheter ablation in long-standing persistent atrial fibrillation (AF), however with limited success. Our study aims at developinginnovative organization indices from baseline ECG (i.e. during the procedure, before ablation) in orderto identify the site of AF termination by catheter ablation. Seventeen consecutive male patients (age60 ± 5 years, AF duration 7 ± 5 years) underwent a stepwise catheter ablation. Chest lead V6 was placedin the back (V6b). QRST cancelation was performed from chest leads V1 to V6b. Using an innovativeadaptive harmonic frequency tracking, two measures of AF organization were computed to quantify theharmonics components of ECG activity: (1) the adaptive phase difference variance (APD) between theAF harmonic components as a measure of AF regularity, and (2) and adaptive organization index (AOI)evaluating the cyclicity of the AF oscillations. Both adaptive indices were compared to indices computedusing a time-invariant approach: (1) ECG AF cycle length (AFCL), (2) the spectrum based organizationindex (OI), and (3) the time-invariant phase difference TIPD. Long-standing persistent AF was terminatedinto sinus rhythm or atrial tachycardia in 13/17 patients during stepwise ablation, 11 during left atriumablation (left terminated patients - LT), 2 during the right atrium ablation (right terminated patients -RT), and 4 were non terminated (NT) and required electrical cardioversion. Our findings showed that LTpatients were best separated from RT/NT before ablation by the duration of sustained AF and by AOI onchest lead V1 and APD from the dorsal lead V6b as compared to ECG AFCL, OI and TIPD, respectively. Ourresults suggest that adaptive measures of AF organization computed before ablation perform better thantime-invariant based indices for identifying patients whose AF will terminate during ablation within theleft atrium. These findings are indicative of a higher baseline organization in these patients that could beused to select candidates for the termination of AF by stepwise catheter ablation.© 2013 Elsevier Ltd. All rights reserved.
Resumo:
Purpose Multiple organization indices (OIs) have been used to predict the outcome of stepwise catheter ablation (step-CA) in long-standing persistent AF (pers-AF), however with limited success. Our study aims at developing innovative OIs from baseline (BL, before ablation) ECG in order to predict the outcome of step-CA. Methods Fourteen consecutive patients (pts) (60±5 y, AF duration 21±9 m) underwent a step-CA consisting in pulmonary veins isolation, left atrial (LA) defragmentation and linear ablations, and right atrial (RA) ablations if non terminated. Chest lead V6 was placed in the back (V6b). After QRST cancellation from chest leads V1 to V6b, two OIs were computed to quantify the harmonic components of ECG atrial activity: 1) phase difference variance (PD) between the AF harmonic components as a measure of AF regularity, and 2) adaptive OI (AOI) evaluating the time evolution of the AF harmonic components. Both indices were compared to classical ones: a spectrum-based OI (SOI) and ECG AF cycle length (AFCL). Results Pers-AF was terminated into sinus rhythm or atrial tachycardia in 10/14 pts during step-CA, 8 during LA (LT), 2 during RA (RT) ablation, and 4 were non terminated (NT). The figure shows that LT was best separated from RT/NT before ablation by AOI computed on lead V1 (A) and PD from lead V6b (B) as compared to SOI and AFCL respectively. Conclusion Our results suggest that adaptive OIs computed before ablation perform better than classical OIs for separating LT from RT/NT pts. These findings are indicative of a higher baseline organization in LT pts that could be used to select candidates for the restoration of sinus rhythm by step-CA.
Resumo:
BACKGROUND: This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point. METHODS AND RESULTS: One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43-73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070-7.143; P<0.001), left atrial diameter ≥50 mm (hazard ratio 2.083; 95% confidence interval, 1.078-4.016; P=0.03), continuous AF duration ≥18 months (hazard ratio 1.984; 95% confidence interval, 1.024-3.846; P<0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037-3.388; P=0.04) predicted arrhythmia recurrence. CONCLUSIONS: In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.
Resumo:
BACKGROUND: Percutaneous catheter ablation of atrial fibrillation (CA-AF) is a treatment option for symptomatic drug-refractory atrial fibrillation (AF). CA-AF carries a risk for thromboembolic complications that has been minimized by the use of intraprocedural intravenous unfractionated heparin (UFH). The optimal administration of UFH as well as its kinetics are not well established and need to be precisely determined. METHODS AND RESULTS: A total 102 of consecutive patients suffering from symptomatic drug-refractory AF underwent CA-AF. The mean age was 61 ± 10 years old. After transseptal puncture of the fossa ovalis, weight-adjusted UFH bolus (100 U/kg) was infused. A significant increase in activated clotting time (ACT) was observed from an average value of 100 ± 27 seconds at baseline, to 355 ± 94 seconds at 10 min (T10), to 375 ± 90 seconds at 20 min (T20). Twenty-four patients failed to reach the targeted ACT value of ≥300 seconds at T10 and more than half of these remained with subtherapeutic ACT values at T20. This subset of patients showed similar clinical characteristics and amount of UFH but were more frequently prescribed preprocedural vitamin K1 than the rest of the study population. CONCLUSIONS: In a typical intervention setting, UFH displays unexpected slow anticoagulation kinetics in a significant proportion of procedures up to 20 minutes after infusion. These findings support the infusion of UFH before transseptal puncture or any left-sided catheterization with early ACT measurements to identify patients with delayed kinetics. They are in line with recent guidelines to perform CA-AF under therapeutic anticoagulation.
Resumo:
INTRODUCTION: Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS: A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS: Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.
Resumo:
CONTEXTE: L'ablation percutanée par cathéter de la fibrillation auriculaire (AC-FA) est une option de traitement pour les patients souffrant de fibrillation auriculaire (FA) symptomatique réfractaire au traitement médicamenteux. L'AC-FA comporte un risque de complications thromboemboliques qui a été réduit par l'utilisation de l'héparine non fractionnée (HNF) intraveineuse durant la procédure. L'administration optimale de l'HNF ainsi que sa cinétique ne sont pas bien établies et nécessitent d'être déterminées avec précision. MÉTHODES ET RÉSULTATS: Cette étude a inclus 102 patients consécutifs atteints de FA symptomatique, réfractaire au traitement médicamenteux, référés pour une AC-FA. L'âge moyen était de 61 ± 10 ans. Après une ponction transseptale de la fosse ovale, une injection intraveineuse de HNF ajustée au poids (100 U / kg) a été administré. Une augmentation significative du temps de coagulation activé (ACT) a été observée passant d'une valeur de base moyenne de 100 ± 27 secondes, à 355 ± 94 secondes à 10 minutes (T10) et à 375 ± 90 secondes à 20 minutes (T20). 24 patients n'ont pas atteint la valeur visée d'ACT > 300 secondes à T10 et plus de la moitié de ce collectif est resté avec les valeurs d'ACT infrathérapeutiques à T20. Ce sous-ensemble de patients avait des caractéristiques cliniques similaires et avait reçu des doses similaires d'HNF, mais s'était plus fréquemment fait prescrire de la vitamine Kl pré-procédurale que le reste de la population de l'étude. CONCLUSION: Au cours d'une intervention standard, l'HNF montre, de manière inattendue, une cinétique d'anticoagulation lente dans une proportion significative des procédures et ceci jusqu'à 20 minutes après l'administration. Ces résultats soutiennent l'importance d'une administration d'HNF avant la ponction transseptale ou tout cathétérisme gauche avec des mesures précoces et répétées d'ACT afin d'identifier les patients avec une cinétique retardée. Ils sont en ligne avec les directives récentes proposant d'effectuer l'AC-FA sous anticoagulation thérapeutique.
Resumo:
Intracardiac organization indices such as atrial fibril- lation (AF) cycle length (AFCL) have been used to track the efficiency of stepwise catheter ablation (step-CA) of long-standing persistent AF (pers-AF), however, with lim- ited success. The timing between nearby bipolar intracar- diac electrograms (EGMs) reflects the spatial dynamics of wavelets during AF. The extent of synchronization between EGMs is an indirect measure of AF spatial organization. The synchronization between nearby EGMs during step- CA of pers-AF was evaluated using new indices based on the cross-correlation. The first one (spar(W)) quantifies the sparseness of the cross-correlation of local activation times. The second one (OI(W)) reflects the local concen- tration around the largest peak of the cross-correlation. By computing their relative evolution during step-CA until AF termination (AF-term), we found that OI(W) appeared su- perior to AFCL and spar(W) to track the effect of step-CA "en route" to AF-term.
Resumo:
A 46-year-old man underwent radiofrequency (RF) ablation of three liver metastases 7 months after undergoing right colectomy for a pT2N0Mx colon adenocarcinoma. Three months after the procedure, he developed hepatic abscesses related to a fistula between the distal ileum and segment V biliary branches.
Resumo:
INTRODUCTION: Persistent atrial fibrillation (AF) ablation may lead to partial disconnection of the coronary sinus (CS). As a result, disparate activation sequences of the local CS versus contiguous left atrium (LA) may be observed during atrial tachycardia (AT). We aimed to evaluate the prevalence of this phenomenon and its impact on activation mapping. METHODS: AT occurring after persistent AF ablation were investigated in 74 consecutive patients. Partial CS disconnection during AT was suspected when double potentials with disparate activation sequences were observed on the CS catheter. Endocardial mapping facing CS bipoles was performed to differentiate LA far-field from local CS potentials. RESULTS: A total of 149 ATs were observed. Disparate LA-CS activations were apparent in 20 ATs after magnifying the recording scale (13%). The most common pattern (90%) was distal to proximal endocardial LA activation against proximal to distal CS activation, the latter involving the whole CS or its distal part. Perimitral macroreentry was more common when disparate LA-CS activations were observed (67% vs 29%; P = 0.002). Partial CS disconnection also resulted in "pseudo" mitral isthmus (MI) block during LA appendage pacing in 20% of patients as local CS activation was proximal to distal despite distal to proximal activation of the contiguous LA. CONCLUSION: Careful analysis of CS recordings during AT following persistent AF ablation often reveals disparate patterns of activation. Recognizing when endocardial LA activation occurs in the opposite direction to the more obvious local CS signals is critical to avoid misleading interpretations during mapping of AT and evaluation of MI block.
A New Method for ECG Tracking of Persistent Atrial Fibrillation Termination during Stepwise Ablation
Resumo:
Stepwise radiofrequency catheter ablation (step-CA) has become the treatment of choice for the restoration of sinus rhythm (SR) in patients with long-standing persistent atrial fibrillation (pers-AF). Its success rate appears limited as the amount of ablation to achieve long term SR is unknown. Multiple organization indexes (OIs) have been previously developed to track the organization of AF during step-CA, however, with limited success. We report an adaptive method for tracking AF termination (AF-term) based on OIs characterizing the relationship between harmonic components of atrial activity from the surface ECG of AF activity. By computing their relative evolution during the last two steps preceding AF-term, we found that the performance of our OIs was superior to classical indices to track the efficiency of step-CA "en route" to AF-term. Our preliminary results suggest that the gradual synchronization between the fundamental and its first harmonic of AF activity appears as a promising parameter for predicting AF-term during step-CA.
Resumo:
Ablation strategies for the treatment of atrial fibrillation (AF) are associated with several potential complications. During electro-anatomic mapping of the left atrium (LA) before ablation, the ablation catheter was entrapped in the right inferior pulmonary vein (RIPV). After multiple unsuccessful gentle tractions, stronger maneuvers with rotation of the catheter slowly allowed its retrieval. Examination of the catheter showed a thin, translucent membrane covering its tip, suggesting complete stripping of a vein branch. Occlusion of the superior branch of the RIPV was confirmed by LA angiogram. During the following days, no pericardial effusion was noted, but the patient complained of light chest pain and mild hemoptysis, spontaneously resolving within 48 h. This case shows that catheter entrapment and mechanical disruption of a PV branch can be a rare potential complication of AF ablation. In this case, the outcome was spontaneously favorable and symptoms only included transient mild hemoptysis.
Resumo:
The glomus tumor is a rare, benign, but painful vascular neoplasm arising from the neuromyoarterial glomus. Primary intraosseous glomus tumor is even rarer, with only about 20 cases reported in the literature so far, 5 of which involved the spine. Surgical resection is currently considered the treatment of choice. We herewith present an uncommon case of primary intraosseous spinal glomus tumor involving the right pedicle of the eleventh thoracic vertebra (T11). To our knowledge, this is the first case of primary intraosseous spinal glomus tumor successfully treated by percutaneous CT-guided radiofrequency ablation (RFA).