Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To examine the relationship of functional measurements with structural measures. Methods: 146 eyes of 83 test subjects underwent Heidelberg Retinal Tomography (HRTIII) (disc area<2.43, mphsd<40), and perimetry testing with Octopus (SAP; Dynamic), Pulsar (PP; TOP) and Moorfields MDT (ESTA). Glaucoma was defined as progressive structural or functional loss (20 eyes). Perimetry test points were grouped into 6 sectors based on the estimated optic nerve head angle into which the associated nerve fiber bundle enters (Garway-Heath map). Perimetry summary measures (PSM) (MD SAP/ MD PP/ PTD MDT) were calculated from the average total deviation of each measured threshold from the normal for each sector. We calculated the 95% significance level of the sectorial PSM from the respective normative data. We calculated the percentage agreement with group1 (G1), healthy on HRT and within normal perimetric limits, and group 2 (G2), abnormal on HRT and outside normal perimetric limits. We also examined the relationship of PSM and rim area (RA) in those sectors classified as abnormal by MRA (Moorfields Regression Analysis) of HRT. Results: The mean age was 65 (range= [37, 89]). The global sensitivity versus specificity of each instrument in detecting glaucomatous eyes was: MDT 80% vs. 88%, SAP 80% vs. 80%, PP 70% vs. 89% and HRT 80% vs. 79%. Highest percentage agreement of HRT (respectively G1, G2, sector) with PSM were MDT (89%, 57%, nasal superior), SAP (83%, 74%, temporal superior), PP (74%, 63%, nasal superior). Globally percentage agreement (respectively G1, G2) was MDT (92%, 28%), SAP (87%, 40%) and PP (77%, 49%). Linear regression showed there was no significant trend globally associating RA and PSM. However, sectorally the supero-nasal sector had a statistically significant (p<0.001) trend with each instrument, the associated r2 coefficients are (MDT 0.38 SAP 0.56 and PP 0.39). Conclusions: There were no significant differences in global sensitivity or specificity between instruments. Structure-function relationships varied significantly between instruments and were consistently strongest supero-nasally. Further studies are required to investigate these relationships in detail.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To determine whether the relative afferent pupillary defect (RAPD) remains constant over time in normal subjects. METHODS: Seventeen normal subjects were tested with infrared pupillography and automated perimetry in four sessions over 3 years. The changes in RAPD and visual field asymmetry between testing sessions were compared. RESULTS: The range of RAPD was 0.0 to 0.3 log unit, and the difference in the mean deviation between the eyes on automated static perimetry was 0 to 3 dB. Eight subjects repeatedly had an RAPD in the same eye. There was no correlation between the RAPD and the visual field asymmetry at the same visit. Changes in the magnitude of the RAPD between any two sessions were typically small (median, 0.08 log unit; 25th percentile, 0.04 log unit; 75th percentile, 0.15 log unit). CONCLUSIONS: Some normal subjects may show a persistent but small RAPD in the absence of detectable pathologic disease. Therefore, an isolated RAPD in the range of 0.3 log unit that is not associated with any other significant historical or clinical finding should probably be considered benign.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To investigate the effect of intraocular straylight (IOS) induced by white opacity filters (WOF) on threshold measurements for stimuli employed in three perimeters: standard automated perimetry (SAP), pulsar perimetry (PP) and the Moorfields motion displacement test (MDT).¦METHODS: Four healthy young (24-28 years old) observers were tested six times with each perimeter, each time with one of five different WOFs and once without, inducing various levels of IOS (from 10% to 200%). An increase in IOS was measured with a straylight meter. The change in sensitivity from baseline was normalized, allowing comparison of standardized (z) scores (change divided by the SD of normative values) for each instrument.¦RESULTS: SAP and PP thresholds were significantly affected (P < 0.001) by moderate to large increases in IOS (50%-200%). The drop in motion displacement (MD) from baseline with WOF 5, was approximately 5 dB, in both SAP and PP which represents a clinically significant loss; in contrast the change in MD with MDT was on average 1 minute of arc, which is not likely to indicate a clinically significant loss.¦CONCLUSIONS: The Moorfields MDT is more robust to the effects of additional straylight in comparison with SAP or PP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To assess the diagnostic accuracy of the Heidelberg Retinal Tomograph 3 (HRT3) as a screening device in comparison with the reference standard of Octopus standard automated perimetry results (SAP) combined with clinical findings. Methods: All patients underwent screening examinations and investigations within a single day. Abnormal screening results were classified as follows: The HRT3: Either "borderline" or "outside normal limits" using the global Moorfields classification (MFC); SAP and clinical exam: A mean defect > 2.4 dB or "outside normal limits" clear text analysis of SAP; and one of the following i) IOP > 21 mmHg, ii) Van Herrick < ¼, iii) cup disc ratio > 0.55, iv) optic nerve head abnormality, v) narrow iridocorneal angle or vi) evidence of peripheral anterior synechiae on gonioscopy. Results: The mean age of the participants was 59.9 years (± 14.8 [21, 91]). Twenty-three subjects (16 %) were classified as abnormal on SAP and clinical exam. The HRT3 classification had a sensitivity of 30 % (95 % CI [16 %, 51 %]) with associated specificity of 58 % (95 % CI [49 %, 66 %]). Of the sixty subjects classified as borderline or outside normal limits with the HRT MFC global result, seven subjects were also abnormal according to SAP and clinical exam. Conclusion: The results suggest that the HRT3 may not be suitable as a sole screening device; however, further investigation is necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In patients with outer retinal degeneration, a differential pupil response to long wavelength (red) versus short wavelength (blue) light stimulation has been previously observed. The goal of this study was to quantify differences in the pupillary re-dilation following exposure to red versus blue light in patients with outer retinal disease and compare them with patients with optic neuropathy and with healthy subjects. DESIGN: Prospective comparative cohort study. PARTICIPANTS: Twenty-three patients with outer retinal disease, 13 patients with optic neuropathy and 14 normal subjects. METHODS: Subjects were tested using continuous red and blue light stimulation at three intensities (1, 10 and 100 cd/m2) for 13 s per intensity. Pupillary re-dilation dynamics following the brightest intensity was analysed and compared between the three groups. MAIN OUTCOME MEASURES: The parameters of pupil re-dilation used in this study were: time to recover 90% of baseline size; mean pupil size at early and late phases of re-dilation; and differential re-dilation time for blue versus red light. RESULTS: Patients with outer retinal disease showed a pupil that tended to stay smaller after light termination and thus had a longer time to recovery. The differential re-dilation time was significantly greater in patients with outer retinal disease (median = 28.0 s, P < 0.0001) compared with controls and patients with optic neuropathy. CONCLUSIONS: A differential response of pupil re-dilation following red versus blue light stimulation is present in patients with outer retinal disease but is not found in normal eyes or among patients with visual loss from optic neuropathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In hyperdiploid acute lymphoblastic leukaemia (ALL), the simultaneous occurrence of specific aneuploidies confers a more favourable outcome than hyperdiploidy alone. Interphase (I) FISH complements conventional cytogenetics (CC) through its sensitivity and ability to detect chromosome aberrations in non-dividing cells. To overcome the limits of manual I-FISH, we developed an automated four-colour I-FISH approach and assessed its ability to detect concurrent aneuploidies in ALL. I-FISH was performed using centromeric probes for chromosomes 4, 6, 10 and 17. Parameters established for automatic nucleus selection and signal detection were evaluated (3 controls). Cut-off values were determined (10 controls, 1000 nuclei/case). Combinations of aneuploidies were considered relevant when each aneuploidy was individually significant. Results obtained in 10 ALL patients (1500 nuclei/patient) were compared with those by CC. Various combinations of aneuploidies were identified. All clones detected by CC were observed by I-FISH. I-FISH revealed numerous additional abnormal clones, ranging between 0.1 % and 31.6%, based on the large number of nuclei evaluated. Four-colour automated I-FISH permits the identification of concurrent aneuploidies of prognostic significance in hyperdiploid ALL. Large numbers of cells can be analysed rapidly by this method. Owing to its high sensitivity, the method provides a powerful tool for the detection of small abnormal clones at diagnosis and during follow up. Compared to CC, it generates a more detailed cytogenetic picture, the biological and clinical significance of which merits further evaluation. Once optimised for a given set of probes, the system can be easily adapted for other probe combinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital holographic microscopy (DHM) allows optical-path-difference (OPD) measurements with nanometric accuracy. OPD induced by transparent cells depends on both the refractive index (RI) of cells and their morphology. This Letter presents a dual-wavelength DHM that allows us to separately measure both the RI and the cellular thickness by exploiting an enhanced dispersion of the perfusion medium achieved by the utilization of an extracellular dye. The two wavelengths are chosen in the vicinity of the absorption peak of the dye, where the absorption is accompanied by a significant variation of the RI as a function of the wavelength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Enterovirus (EV) is the most frequent cause of aseptic meningitis (AM). Lack of microbiological documentation results in unnecessary antimicrobial therapy and hospitalization. OBJECTIVES: To assess the impact of rapid EV detection in cerebrospinal fluid (CSF) by a fully-automated PCR (GeneXpert EV assay, GXEA) on the management of AM. STUDY DESIGN: Observational study in adult patients with AM. Three groups were analyzed according to EV documentation in CSF: group A=no PCR or negative PCR (n=17), group B=positive real-time PCR (n=20), and group C=positive GXEA (n=22). Clinical, laboratory and health-care costs data were compared. RESULTS: Clinical characteristics were similar in the 3 groups. Median turn-around time of EV PCR decreased from 60h (IQR (interquartile range) 44-87) in group B to 5h (IQR 4-11) in group C (p<0.0001). Median duration of antibiotics was 1 (IQR 0-6), 1 (0-1.9), and 0.5 days (single dose) in groups A, B, and C, respectively (p<0.001). Median length of hospitalization was 4 days (2.5-7.5), 2 (1-3.7), and 0.5 (0.3-0.7), respectively (p<0.001). Median hospitalization costs were $5458 (2676-6274) in group A, $2796 (2062-5726) in group B, and $921 (765-1230) in group C (p<0.0001). CONCLUSIONS: Rapid EV detection in CSF by a fully-automated PCR improves management of AM by significantly reducing antibiotic use, hospitalization length and costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract : In the subject of fingerprints, the rise of computers tools made it possible to create powerful automated search algorithms. These algorithms allow, inter alia, to compare a fingermark to a fingerprint database and therefore to establish a link between the mark and a known source. With the growth of the capacities of these systems and of data storage, as well as increasing collaboration between police services on the international level, the size of these databases increases. The current challenge for the field of fingerprint identification consists of the growth of these databases, which makes it possible to find impressions that are very similar but coming from distinct fingers. However and simultaneously, this data and these systems allow a description of the variability between different impressions from a same finger and between impressions from different fingers. This statistical description of the withinand between-finger variabilities computed on the basis of minutiae and their relative positions can then be utilized in a statistical approach to interpretation. The computation of a likelihood ratio, employing simultaneously the comparison between the mark and the print of the case, the within-variability of the suspects' finger and the between-variability of the mark with respect to a database, can then be based on representative data. Thus, these data allow an evaluation which may be more detailed than that obtained by the application of rules established long before the advent of these large databases or by the specialists experience. The goal of the present thesis is to evaluate likelihood ratios, computed based on the scores of an automated fingerprint identification system when the source of the tested and compared marks is known. These ratios must support the hypothesis which it is known to be true. Moreover, they should support this hypothesis more and more strongly with the addition of information in the form of additional minutiae. For the modeling of within- and between-variability, the necessary data were defined, and acquired for one finger of a first donor, and two fingers of a second donor. The database used for between-variability includes approximately 600000 inked prints. The minimal number of observations necessary for a robust estimation was determined for the two distributions used. Factors which influence these distributions were also analyzed: the number of minutiae included in the configuration and the configuration as such for both distributions, as well as the finger number and the general pattern for between-variability, and the orientation of the minutiae for within-variability. In the present study, the only factor for which no influence has been shown is the orientation of minutiae The results show that the likelihood ratios resulting from the use of the scores of an AFIS can be used for evaluation. Relatively low rates of likelihood ratios supporting the hypothesis known to be false have been obtained. The maximum rate of likelihood ratios supporting the hypothesis that the two impressions were left by the same finger when the impressions came from different fingers obtained is of 5.2 %, for a configuration of 6 minutiae. When a 7th then an 8th minutia are added, this rate lowers to 3.2 %, then to 0.8 %. In parallel, for these same configurations, the likelihood ratios obtained are on average of the order of 100,1000, and 10000 for 6,7 and 8 minutiae when the two impressions come from the same finger. These likelihood ratios can therefore be an important aid for decision making. Both positive evolutions linked to the addition of minutiae (a drop in the rates of likelihood ratios which can lead to an erroneous decision and an increase in the value of the likelihood ratio) were observed in a systematic way within the framework of the study. Approximations based on 3 scores for within-variability and on 10 scores for between-variability were found, and showed satisfactory results. Résumé : Dans le domaine des empreintes digitales, l'essor des outils informatisés a permis de créer de puissants algorithmes de recherche automatique. Ces algorithmes permettent, entre autres, de comparer une trace à une banque de données d'empreintes digitales de source connue. Ainsi, le lien entre la trace et l'une de ces sources peut être établi. Avec la croissance des capacités de ces systèmes, des potentiels de stockage de données, ainsi qu'avec une collaboration accrue au niveau international entre les services de police, la taille des banques de données augmente. Le défi actuel pour le domaine de l'identification par empreintes digitales consiste en la croissance de ces banques de données, qui peut permettre de trouver des impressions très similaires mais provenant de doigts distincts. Toutefois et simultanément, ces données et ces systèmes permettent une description des variabilités entre différentes appositions d'un même doigt, et entre les appositions de différents doigts, basées sur des larges quantités de données. Cette description statistique de l'intra- et de l'intervariabilité calculée à partir des minuties et de leurs positions relatives va s'insérer dans une approche d'interprétation probabiliste. Le calcul d'un rapport de vraisemblance, qui fait intervenir simultanément la comparaison entre la trace et l'empreinte du cas, ainsi que l'intravariabilité du doigt du suspect et l'intervariabilité de la trace par rapport à une banque de données, peut alors se baser sur des jeux de données représentatifs. Ainsi, ces données permettent d'aboutir à une évaluation beaucoup plus fine que celle obtenue par l'application de règles établies bien avant l'avènement de ces grandes banques ou par la seule expérience du spécialiste. L'objectif de la présente thèse est d'évaluer des rapports de vraisemblance calcul és à partir des scores d'un système automatique lorsqu'on connaît la source des traces testées et comparées. Ces rapports doivent soutenir l'hypothèse dont il est connu qu'elle est vraie. De plus, ils devraient soutenir de plus en plus fortement cette hypothèse avec l'ajout d'information sous la forme de minuties additionnelles. Pour la modélisation de l'intra- et l'intervariabilité, les données nécessaires ont été définies, et acquises pour un doigt d'un premier donneur, et deux doigts d'un second donneur. La banque de données utilisée pour l'intervariabilité inclut environ 600000 empreintes encrées. Le nombre minimal d'observations nécessaire pour une estimation robuste a été déterminé pour les deux distributions utilisées. Des facteurs qui influencent ces distributions ont, par la suite, été analysés: le nombre de minuties inclus dans la configuration et la configuration en tant que telle pour les deux distributions, ainsi que le numéro du doigt et le dessin général pour l'intervariabilité, et la orientation des minuties pour l'intravariabilité. Parmi tous ces facteurs, l'orientation des minuties est le seul dont une influence n'a pas été démontrée dans la présente étude. Les résultats montrent que les rapports de vraisemblance issus de l'utilisation des scores de l'AFIS peuvent être utilisés à des fins évaluatifs. Des taux de rapports de vraisemblance relativement bas soutiennent l'hypothèse que l'on sait fausse. Le taux maximal de rapports de vraisemblance soutenant l'hypothèse que les deux impressions aient été laissées par le même doigt alors qu'en réalité les impressions viennent de doigts différents obtenu est de 5.2%, pour une configuration de 6 minuties. Lorsqu'une 7ème puis une 8ème minutie sont ajoutées, ce taux baisse d'abord à 3.2%, puis à 0.8%. Parallèlement, pour ces mêmes configurations, les rapports de vraisemblance sont en moyenne de l'ordre de 100, 1000, et 10000 pour 6, 7 et 8 minuties lorsque les deux impressions proviennent du même doigt. Ces rapports de vraisemblance peuvent donc apporter un soutien important à la prise de décision. Les deux évolutions positives liées à l'ajout de minuties (baisse des taux qui peuvent amener à une décision erronée et augmentation de la valeur du rapport de vraisemblance) ont été observées de façon systématique dans le cadre de l'étude. Des approximations basées sur 3 scores pour l'intravariabilité et sur 10 scores pour l'intervariabilité ont été trouvées, et ont montré des résultats satisfaisants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on advanced dual-wavelength digital holographic microscopy (DHM) methods, enabling single-acquisition real-time micron-range measurements while maintaining single-wavelength interferometric resolution in the nanometer regime. In top of the unique real-time capability of our technique, it is shown that axial resolution can be further increased compared to single-wavelength operation thanks to the uncorrelated nature of both recorded wavefronts. It is experimentally demonstrated that DHM topographic investigation within 3 decades measurement range can be achieved with our arrangement, opening new applications possibilities for this interferometric technique. ©2008 COPYRIGHT SPIE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of the investigation of the use of automated fingerprint identification systems (AFIS) for the evaluation of fingerprint evidence, the current study presents investigations into the variability of scores from an AFIS system when fingermarks from a known donor are compared to fingerprints that are not from the same source. The ultimate goal is to propose a model, based on likelihood ratios, which allows the evaluation of mark-to-print comparisons. In particular, this model, through its use of AFIS technology, benefits from the possibility of using a large amount of data, as well as from an already built-in proximity measure, the AFIS score. More precisely, the numerator of the LR is obtained from scores issued from comparisons between impressions from the same source and showing the same minutia configuration. The denominator of the LR is obtained by extracting scores from comparisons of the questioned mark with a database of non-matching sources. This paper focuses solely on the assignment of the denominator of the LR. We refer to it by the generic term of between-finger variability. The issues addressed in this paper in relation to between-finger variability are the required sample size, the influence of the finger number and general pattern, as well as that of the number of minutiae included and their configuration on a given finger. Results show that reliable estimation of between-finger variability is feasible with 10,000 scores. These scores should come from the appropriate finger number/general pattern combination as defined by the mark. Furthermore, strategies of obtaining between-finger variability when these elements cannot be conclusively seen on the mark (and its position with respect to other marks for finger number) have been presented. These results immediately allow case-by-case estimation of the between-finger variability in an operational setting.