131 resultados para Taxpayer compliance
em Université de Lausanne, Switzerland
Resumo:
OBJECTIVE: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension. METHODS: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/ 106 +/- 23/11 mmHg, mean +/- SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary. RESULTS: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 +/- 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 +/- 18/15 to 143/94 +/- 22/11 mmHg, P = 0.04/0.02). CONCLUSIONS: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.
Resumo:
The aim of this study was to determine whether breath 13CO2 measurements could be used to assess the compliance to a diet containing carbohydrates naturally enriched in 13C. The study was divided into two periods: Period 1 (baseline of 4 days) with low 13C/12C ratio carbohydrates. Period 2 (5 days) isocaloric diet with a high 13C/12C ratio (corn, cane sugar, pineapple, millet) carbohydrates. Measurements were made of respiratory gas exchange by indirect calorimetry, urinary nitrogen excretion and breath 13CO2 every morning in post-absorptive conditions, both in resting state and during a 45-min low intensity exercise (walking on a treadmill). The subjects were 10 healthy lean women (BMI 20.4 +/- 1.7 kg/m2, % body fat 24.4 +/- 1.3%), the 13C enrichment of oxidized carbohydrate and breath 13CO2 were compared to the enrichment of exogenous dietary carbohydrates. At rest the enrichment of oxidized carbohydrate increased significantly after one day of 13C carbohydrate enriched diet and reached a steady value (103 +/- 16%) similar to the enrichment of exogenous carbohydrates. During exercise, the 13C enrichment of oxidized carbohydrate remained significantly lower (68 +/- 17%) than that of dietary carbohydrates. The compliance to a diet with a high content of carbohydrates naturally enriched in 13C may be assessed from the measurement of breath 13CO2 enrichment combined with respiratory gas exchange in resting, postabsorptive conditions.
Resumo:
The present study was undertaken to examine the cross-sectional vascular compliance at the anastomotic site. METHODS AND MATERIAL: We performed end-to-end anastomosis on the carotid artery of six pigs using continuous 6/0 polypropylene. Four carotid arteries were excised and mounted in a perfusion chamber while the remaining two were left in living animals. We used pulsed ultrasound (NIUS 02) to generate detailed longitudinal profiles of diameter and compliance in the proximity and on the anastomosis. RESULTS: On the anastomosis, the vessel diameter decreases (-1 to -2.6% of diastolic diameter) when blood pressure increases with an exponential correlation (R2 = 0.75). The arterial compliance at the anastomosis was negative: the vessel cross-section reduction for a pulse pressure of 1 up to 32 mmHg was 0.9 to 2% of diastolic vessel cross-section. CONCLUSIONS: Vessel movement generated a dynamic stenosis whose magnitude seems to depend on blood pressure level. Increasing blood pressure causes the retraction of vessel ends which causes vessel lumen reduction. These results suggest that continuous suture does not provide the continuity of mechanical properties of the artery.
Resumo:
Compliance with antihypertensive therapy was monitored for three months using an electronic medication dispenser in 35 patients remaining hypertensive despite the once-daily administration of a blood pressure lowering drug (either as monotherapy or as fixed-dose combination therapy). During the monitoring of compliance, the treatment was unchanged but blood pressure decreased significantly (p < 0.001) from 167.9/100.4 +/- 16.3/7.2 mmHg (mean +/- SD) to 152.5/90.9 +/- 20.9/11.5 mmHg. The percentage of days with one opening per day was 80.8 +/- 20.5. Thus, discussing with the patient about compliance with the prescribed drug regimen and monitoring compliance for a few months allows better control of blood pressure. This most likely reflects increased compliance with antihypertensive drug therapy.
Resumo:
Introduction: There is little information regarding compliance with dietary recommendations in Switzerland. Objectives: To assess the trends in compliance with dietary recommendations in the Geneva population for period 1999 - 2009. Methods: Ten cross-sectional, population-based surveys (Bus Santé study). Dietary intake was assessed using a self-administered, validated semi quantitative Food Frequency Questionnaire. Compliance with the Swiss Society for Nutrition recommendations for nutrient intake was assessed. In all 9320 participants aged 35 to 75 years (50% women) were included. Trends were assessed by logistic regression adjusting for age, smoking stats, education and nationality, using survey year as the independent variable. Results: After excluding participants with extreme intakes, the percentage of participants with a cholesterol consumption< 300 mg/day increased from 40.8% in 1999 to 43.6% in 2009 for men (multivariate-adjusted p for trend = 0.04) and from 57.8% to 61.4% in women (multivariate-adjusted p for trend = 0.06). Calcium intake > 1 g/day decreased from 53.3% to 46.0% in men and from 47.6% to 40.7% in women (multivariate-adjusted p for trend< 0.001). Adequate iron intake decreased from 68.3%to 65.3% in men and from 13.3% to 8.4% in women (multivariate-adjusted p for trend< 0.001). Conversely, no significant changes were observed for carbohydrates, protein, total fat (including saturated, monounsaturated and polyunsaturated fatty acids), fibre, vitamins D and A. Conclusion: Fewimprovements were noted in adherence to dietary recommendations in the Geneva population between 1999 and 2009. The low and decreasing prevalence of adequate calcium and iron intake are of concern.
Resumo:
OBJECTIVE: To assess the change in non-compliant items in prescription orders following the implementation of a computerized physician order entry (CPOE) system named PreDiMed. SETTING: The department of internal medicine (39 and 38 beds) in two regional hospitals in Canton Vaud, Switzerland. METHOD: The prescription lines in 100 pre- and 100 post-implementation patients' files were classified according to three modes of administration (medicines for oral or other non-parenteral uses; medicines administered parenterally or via nasogastric tube; pro re nata (PRN), as needed) and analyzed for a number of relevant variables constitutive of medical prescriptions. MAIN OUTCOME MEASURE: The monitored variables depended on the pharmaceutical category and included mainly name of medicine, pharmaceutical form, posology and route of administration, diluting solution, flow rate and identification of prescriber. RESULTS: In 2,099 prescription lines, the total number of non-compliant items was 2,265 before CPOE implementation, or 1.079 non-compliant items per line. Two-thirds of these were due to missing information, and the remaining third to incomplete information. In 2,074 prescription lines post-CPOE implementation, the number of non-compliant items had decreased to 221, or 0.107 non-compliant item per line, a dramatic 10-fold decrease (chi(2) = 4615; P < 10(-6)). Limitations of the computerized system were the risk for erroneous items in some non-prefilled fields and ambiguity due to a field with doses shown on commercial products. CONCLUSION: The deployment of PreDiMed in two departments of internal medicine has led to a major improvement in formal aspects of physicians' prescriptions. Some limitations of the first version of PreDiMed were unveiled and are being corrected.
Resumo:
Nonadherence to treatment is a common problem in the clinical management of hypercholesterolemic patients. This study was carried out with the aim of monitoring the daily compliance to a 6-month course of lipid-lowering therapy, using a microelectronic device, the Medication Event Monitoring System (MEMS), versus pill count. Forty men with primary hypercholesterolemia were prescribed fluvastatin 1 x 40 mg daily, provided in a MEMS package to record the date and time of each opening of the pillbox. Thirty-nine of 40 patients (98%) completed the study. Total cholesterol and LDL cholesterol levels decreased significantly (18% and 25%, p < 0.001) during the 6-month therapy period. A high mean rate of compliance was achieved by MEMS using the following three indexes--compliance to total prescribed dose (88.8% +/- 13.5%), compliance to prescribed days (82.4% +/- 19.5%), and compliance to prescribed time of day (81.86% +/- 19.5%)--and by pill count (93.4% +/- 9.5%). In addition, the MEMS provided some patterns of nonadherence to medication, undetectable by pill count alone, such as a drug holiday in 38% of cases, a drug omission for more than 7 consecutive days in 9% of cases, and, conversely, use of more than the one prescribed daily dose in 47% of cases. A significant correlation between the rate of compliance and the decrease in LDL cholesterol was observed only when the compliance was assessed by MEMS. The results indicate that MEMS is a useful tool for monitoring compliance in clinical practice and may possibly increase adherence to long-term lipid-lowering therapy.
Resumo:
Par Compliance, on entend l'ensemble des mesures organisationnelles d'une entreprise qui visent à assurer le respect des règles par l'entreprise et ses collaborateurs. Dans le secteur privé - surtout dans les banques et les assurances - la Compliance est un concept bien établi et le poste du Compliance Officer apparaît clairement dans l'organigramme des entreprises. Ce terme apparaît aussi de temps à autre au sein de l'administration fédérale, en relation avec la politique de gestion des risques et le système de contrôle interne (SCI) ; mais une introduction effective de la Compliance n'y a pas encore eu lieu (jusqu'ici). Les Américains ont l'habitude de dire « if you think compliance is expensive, try non compliance ». Cette déclaration, apparemment valable pour le secteur privé, peut-elle cependant être transposée telle quelle au secteur public ? L'introduction d'un système de management tel que la Compliance apporterait-elle effectivement une plus-value par rapport aux systèmes existants afin d'éviter les risques engendrant des conséquences juridiques ou causant une mauvaise réputation suite au non-respect de règles par des collaborateurs ? La présente étude se penche sur ces questions et analyse, sur la base de documents et d'interviews, quels éléments de la Compliance existent au niveau de la Confédération et au sein de l'Office fédéral de la santé publique (OFSP) et s'ils sont propres à atteindre les objectifs visés par la Compliance. Dans plusieurs domaines, on a pu constater des défauts et, par conséquent, un gros potentiel d'amélioration. Le problème principal est l'absence d'organisation au niveau de la Compliance. Cela complique la vue d'ensemble des risques juridiques et de ceux pouvant causer une mauvaise réputation qui existent au niveau de la Confédération et à l'OFSP et rend impossible un management homogène de ces risques. En conséquence et dans l'état actuel des choses, il pourrait s'avérer difficile d'éviter de manière durable la réalisation des risques susmentionnés au moyen des systèmes existants. D'un autre côté, la politique de gestion des risques au sein de la Confédération et l'introduction d'un système de contrôle interne (SCI) ont représenté les premiers pas en direction d'un système de gestion des risques intégré. La Compliance serait un complément idéal et pourrait - dans la mesure où la direction de l'Office la soutient et donne le bon exemple - contribuer à la réduction des risques décrits ci-dessus non seulement au niveau de la Confédération mais encore au sein de l'OFSP. La présente étude ne vise pas pour autant à critiquer les systèmes établis, mais bien plus à montrer le potentiel d'amélioration dont on pourrait tirer profit.
Resumo:
OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.
Resumo:
Poor compliance with antihypertensive drug regimens is one recognized cause of inadequate blood pressure control. Compliance is difficult to measure, so poor adherence to treatment remains largely undiagnosed in clinical practice. When the therapeutic response to a drug is not the one expected, it is a major challenge for many physicians to decide whether the patient is a non-responder or a non-complier. Poor compliance is therefore often incorrectly interpreted as a lack of response to treatment. Not detecting non-compliance can lead to the wrong measures being taken. Electronic monitoring of compliance provides important longitudinal information about drug-intake behaviour that cannot be obtained in the clinic. Such monitoring can improve both compliance and blood pressure control, and help physicians to make more rational therapeutic decisions. A reliable assessment of compliance could have a great impact on medical costs by preventing unnecessary investigations or dose adaptations in patients who are not taking their drugs adequately, or potentially reducing the number of hospitalizations. Side-effects and lack of effectiveness are two frequent causes of poor compliance. The right choice of antihypertensive drug can therefore contribute to compliance. In this respect, it is important to find a drug regimen that is effective, long-acting and well tolerated. Long-acting antihypertensive drugs that provide good blood pressure control beyond the 24-h dosing period should perhaps be considered as drugs of choice in non-compliant patients with hypertension because they help to prevent the consequences of occasional drug omissions.