78 resultados para Swine sanitation
em Université de Lausanne, Switzerland
Resumo:
To avoid the exclusive use of rodent monoclonal antibodies (MAbs) in patients for the detection of tumors by immunoscintigraphy and for radioimmunotherapy, swine MAbs were produced that are directed against carcinoembryonic antigen (CEA). Spleen cells from 2 pigs immunized with purified colon carcinoma CEA were fused with a nonsecreting mouse myeloma cell line by conventional methods, except that a particularly long immunization protocol and large amounts of spleen and myeloma cells were used. Of 1,200 growing hybrids tested, 20 were found initially to produce antibodies binding to radiolabeled CEA. Seven stable clones producing anti-CEA MAbs for more than 6 months were derived from these hybrids by repeated subcloning. The pig origin of the seven MAbs was demonstrated in a solid-phase CEA enzyme immunoassay where anti-pig immunoglobin (Ig) antibodies coupled to peroxidase gave a positive reaction while anti-mouse Ig antibodies were entirely negative. All swine MAbs were of the IgG isotype. Three anti-CEA MAbs showed no cross-reactivity with granulocytes, while four others gave various degrees of reactivity with different granulocyte glycoproteins. Competitive binding to CEA performed for two purified swine MAbs showed that they recognized two different epitopes. The affinity constants measured for these two MAbs by Scatchard plot on purified CEA were high (1.2 X 10(9) and 1.2 X 10(10) liter/mol). One of the MAbs was tested in vivo for tumor localization by injection, after radiolabeling, in nude mice bearing human colon carcinoma xenograft. High ratios of tumor to normal tissue were obtained with mean values of 10.5 for intact MAbs and of 26.8 for F(ab')2 fragments of the porcine MAb. The results showed that heterofusion with this particular protocol can be used to produce swine MAbs of high affinity and specificity for a well-defined tumor marker. These reagents may have an important clinical utility, particularly in patients who became sensitized to mouse immunoglobulins.
Resumo:
Feelings of invulnerability, seen in judgments of 0% risk, can reflect misunderstandings of risk and risk behaviors, suggesting increased need for risk communication. However, judgments of 0% risk may be given by individuals who feel invulnerable, and by individuals who are rounding from small non-zero probabilities. We examined the effect of allowing participants to give more precise responses in the 0-1% range on the validity of reported probability judgments. Participants assessed probabilities for getting H1N1 influenza and dying from it conditional on infection, using a 0-100% visual linear scale. Those responding in the 0-1% range received a follow-up question with more options in that range. This two-step procedure reduced the use of 0% and increased the resolution of responses in the 0-1% range. Moreover, revised probability responses improved predictions of attitudes and self-reported behaviors. Hence, our two-step procedure allows for more precise and more valid measurement of perceived invulnerability. [Authors]
Resumo:
A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease.
Resumo:
BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.
Augmentation cystoplasty using pedicled and de-epithelialized gastric patches in the mini-pig model.
Resumo:
PURPOSE: The most common methods of bladder augmentation are gastrocystoplasty and enterocystoplasty. Gastrocystoplasty is advantageous due to minimal mucous secretion and a well developed muscular wall as well as good urodynamic properties of the patch. However, the permanent contact of urine with the gastric mucosa is not free of complications. We report the urodynamic, macroscopic and histological outcomes of a pedicled de-epithelialized gastric patch incorporated in the bladder. We compared the results to those of our previous study, which sought to analyze these techniques of patch coverage using sigmoid patches. MATERIALS AND METHODS: We performed 20 augmentation cystoplasties in the mini-pig model using a pedicled de-epithelialized gastric patch and 5 techniques of patch coverage. RESULTS: Three months after surgery all bladders had an increase in volume except those in which the auto-augmentation technique was used. However, all gastric patches were smaller compared to preoperative size. Many had irregular fibrosed inner surfaces and histological evaluation revealed a fibrosed newly formed submucosal layer with a complete urothelial coverage in every patch. No gastric mucosal remnant was found. CONCLUSIONS: De-epithelialized gastrocystoplasty is an attractive procedure that can increase bladder capacity as well as provide a complete urothelial lining without mucosal remnants. However, the success of this procedure seems to be limited by increased morbidity and fibrotic changes, and decreased surface of the patch.
Resumo:
A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.
Resumo:
Different embolic materials for portal vein embolization (PVE) were evaluated. Twenty pigs received left and median PVE. Hydrophilic phosphorylcholine, N-butyl cyanoacrylate, hydrophilic gel, and polyvinyl alcohol (PVA) particles measuring either 50-150 microm or 700-900 microm were used in five pigs each. Portography and portal vein pressure measurement were performed before, immediately after PVE, and before being euthanized at day 7. Tissue wedges from embolized, and non-embolized liver were obtained for pathology. After complete embolization, recanalization occurred at 7 days in one gel and one 700-900 PVA embolization. Post-PVE increase in portal pressure was found in all groups (p = 0.01). The area of the hepatic lobules in non-embolized liver was larger than in the embolized liver in all groups (p = 0.001). The ratios of the areas between non-embolized/embolized livers were 1.65, 2.19, 1.57, and 1.32 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively; the ratios of fibrosis between the embolized and non-embolized livers were 1.37, 3.01, 3.49, and 2.11 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively. Hepatic lobules in non-embolized liver were significantly larger with NBCA than in other groups (p = 0.01). Fibrosis in embolized liver was significantly higher for NBCA and 50-150 PVA (p = 0.002). The most severe changes in embolized and non-embolized liver were induced by 50-150 PVA and NCBA PVE.
Resumo:
The present study was undertaken to examine the cross-sectional vascular compliance at the anastomotic site. METHODS AND MATERIAL: We performed end-to-end anastomosis on the carotid artery of six pigs using continuous 6/0 polypropylene. Four carotid arteries were excised and mounted in a perfusion chamber while the remaining two were left in living animals. We used pulsed ultrasound (NIUS 02) to generate detailed longitudinal profiles of diameter and compliance in the proximity and on the anastomosis. RESULTS: On the anastomosis, the vessel diameter decreases (-1 to -2.6% of diastolic diameter) when blood pressure increases with an exponential correlation (R2 = 0.75). The arterial compliance at the anastomosis was negative: the vessel cross-section reduction for a pulse pressure of 1 up to 32 mmHg was 0.9 to 2% of diastolic vessel cross-section. CONCLUSIONS: Vessel movement generated a dynamic stenosis whose magnitude seems to depend on blood pressure level. Increasing blood pressure causes the retraction of vessel ends which causes vessel lumen reduction. These results suggest that continuous suture does not provide the continuity of mechanical properties of the artery.
Resumo:
In type I diabetes mellitus, islet transplantation provides a moment-to-moment fine regulation of insulin. Success rates vary widely, however, necessitating suitable methods to monitor islet delivery, engraftment and survival. Here magnetic resonance-trackable magnetocapsules have been used simultaneously to immunoprotect pancreatic beta-cells and to monitor, non-invasively in real-time, hepatic delivery and engraftment by magnetic resonance imaging (MRI). Magnetocapsules were detected as single capsules with an altered magnetic resonance appearance on capsule rupture. Magnetocapsules were functional in vivo because mouse beta-cells restored normal glycemia in streptozotocin-induced diabetic mice and human islets induced sustained C-peptide levels in swine. In this large-animal model, magnetocapsules could be precisely targeted for infusion by using magnetic resonance fluoroscopy, whereas MRI facilitated monitoring of liver engraftment over time. These findings are directly applicable to ongoing improvements in islet cell transplantation for human diabetes, particularly because our magnetocapsules comprise clinically applicable materials.
Resumo:
Dynamic assembly and disassembly of microtubules is essential for cell division, cell movements, and intracellular transport. In the developing nervous system, microtubule dynamics play a fundamental role during neurite outgrowth, elongation, and branching, but the molecular mechanisms involved are unknown. SCG10 is a neuron-specific protein that is membrane-associated and highly enriched in growth cones. Here we show that SCG10 binds to microtubules, inhibits their assembly, and can induce microtubule disassembly. We also show that SCG10 overexpression enhances neurite outgrowth in a stably transfected neuronal cell line. These data identify SCG10 as a key regulator of neurite extension through regulation of microtubule instability.
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Resumo:
BACKGROUND: Large intrathoracic airway defects may be closed using a pedicled latissimus dorsi (LD) flap, with rewarding results. This study addresses the question of whether this holds true for extrathoracic non-circumferential tracheal defects. METHODS: A cervical segment of the trachea of 4 x 1 cm was resected in 9 white male pigs. The defect was stented with a silicone stent for 3 months and closed either by an LD flap alone (group a, n = 3), an LD flap with an attached rib segment covered by pleura (group b, n = 3), or an LD flap reinforced by a perforated polylactide (MacroPore) plate (group c, n = 3). The trachea was assessed by rigid endoscopy at 3 and 4 months and histologically at 4 months postoperatively. RESULTS: The degree of stenosis at the level of the reconstruction at 4 months was 25, 50 and 75% in group a, 15, 50 and 60% in group b, and 20, 95 and 95% in group c, respectively. The percentage of the defect covered by columnar epithelium was 100% in all animals of group a, 60, 100 and 100% in group b, and 10, 0 and 0% in group c. Resorption of the rib was seen in all animals of group b and obstructive inflammatory polyps were found in 2 animals of group c. CONCLUSION: Pedicled LD flaps provided less satisfactory results for closure of large non-circumferential extrathoracic airway defects than observed after intrathoracic reconstruction. A pedicled rib segment added to the LD flap did not improve the results obtained from LD flap repair alone, and an embedded MacroPore prosthesis may result in severe airway stenosis due to plate migration and intense inflammatory reaction protruding into the tracheal lumen.
Resumo:
BACKGROUND/AIMS: Restenosis after percutaneous transluminal angioplasty (PTA) of the internal mammary artery (IMA) grafts is much less pronounced than in other arteries and venous grafts. The aim of the study was to test whether various arteries respond differently to dilatation. METHODS: PTA of the IMA, carotid, renal and circumflex coronary (RCx) arteries was performed in 9 pigs (balloon to artery ratio of 1:1.5). After 8 weeks, angiography was repeated and vessels prepared for histological analysis. Immunohistochemical staining was done to examine proliferative activity (Ki67) and to identify the vasa vasorum of the adventitia (F VIII-RA). RESULTS: The intima-media ratio after PTA was lowest in the IMA (0.06), followed by the carotid (0.27) and renal arteries (0.49) and the RCx (0.69). Proliferation of the intima was seen at 287 degrees of the vessel circumference in the RCx, at 286 degrees in the renal and at 166 degrees in the carotid artery. No proliferative activity was seen in the IMA. The intima-adventitia ratio was lower in the IMA than in the RCx and renal arteries (p < 0.05). CONCLUSION: Intima proliferation after PTA varies between the different vessels, with best results seen in the IMA. There are differences in remodeling after PTA between muscular, muscular/elastic and elastic arteries.
Preretinal partial pressure of oxygen gradients before and after experimental pars plana vitrectomy.
Resumo:
PURPOSE: To evaluate preretinal partial pressure of oxygen (PO2) gradients before and after experimental pars plana vitrectomy. METHODS: Arteriolar, venous, and intervascular preretinal PO2 gradients were recorded in 7 minipigs during slow withdrawal of oxygen-sensitive microelectrodes (10-μm tip diameter) from the vitreoretinal interface to 2 mm into the vitreous cavity. Recordings were repeated after pars plana vitrectomy and balanced salt solution (BSS) intraocular perfusion. RESULTS: Arteriolar, venous, and intervascular preretinal PO2 at the vitreoretinal interface were 62.3 ± 13.8, 22.5 ± 3.3, and 17.0 ± 7.5 mmHg, respectively, before vitrectomy; 97.7 ± 19.9, 40.0 ± 21.9, and 56.3 ± 28.4 mmHg, respectively, immediately after vitrectomy; and 59.0 ± 27.4, 25.2 ± 3.0, and 21.5 ± 4.5 mmHg, respectively, 2½ hours after interruption of BSS perfusion. PO2 2 mm from the vitreoretinal interface was 28.4 ± 3.6 mmHg before vitrectomy; 151.8 ± 4.5 mmHg immediately after vitrectomy; and 34.8 ± 4.1 mmHg 2½ hours after interruption of BSS perfusion. PO2 gradients were still present after vitrectomy, with the same patterns as before vitrectomy. CONCLUSION: Preretinal PO2 gradients are not eliminated after pars plana vitrectomy. During BSS perfusion, vitreous cavity PO2 is very high. Interruption of BSS perfusion evokes progressive equilibration of vitreous cavity PO2 with concomitant progressive return of preretinal PO2 gradients to their previtrectomy patterns. This indicates that preretinal diffusion of oxygen is not altered after vitrectomy. The beneficial effect of vitrectomy in ischemic retinal diseases or macular edema may be related to other mechanisms, such as increased oxygen convection currents or removal of growth factors and cytokines secreted in the vitreous.