27 resultados para Spin Chains

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of click chemistry to develop libraries of organometallic ruthenium-arene complexes with potential anticancer properties has been investigated. A series of ruthenium-imidazole-triazole complexes, with hydrophobic tails, were prepared from a common precursor via click chemistry. The tail could be attached to the ligand prior to coordination to the ruthenium complex were screened for cytotoxicity in tumourigenic and non-tumourigenic cell lines, and while the compounds were only moderately cytotoxic, good selectivity for tumourigenic cells were abserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - The purpose of this paper is to document the outcome of a global three-year long supply chain improvement initiative at a multi-national producer of branded sporting goods that is transforming from a holding structure to an integrated company. The case company is comprised of seven internationally well-known sport brands, which form a diverse set of independent sub-cases, on which the same supply chain metrics and change project approach was applied to improve supply chain performance. Design/methodology/approach - By using in-depth case study and statistical analysis the paper analyzes across the brands how supply chain complexity (SKU count), supply chain type (make or buy) and seasonality affect completeness and punctuality of deliveries, and inventory as the change project progresses. Findings - Results show that reduction in supply chain complexity improves delivery performance, but has no impact on inventory. Supply chain type has no impact on service level, but brands with in-house production are better in improving inventory than those with outsourced production. Non-seasonal business units improve service faster than seasonal ones, yet there is no impact on inventory. Research limitations/implications - The longitudinal data used for the analysis is biased with the general business trend, yet the rich data from different cases and three-years of data collection enables generalizations to a certain level. Practical implications - The in-depth case study serves as an example for other companies on how to initiate a supply chain improvement project across business units with tangible results. Originality/value - The seven sub-cases with their different characteristics on which the same improvement initiative was applied sets a unique ground for longitudinal analysis to study supply chain complexity, type and seasonality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to prospectively compare free-breathing navigator-gated cardiac-triggered three-dimensional steady-state free precession (SSFP) spin-labeling coronary magnetic resonance (MR) angiography performed by using Cartesian k-space sampling with that performed by using radial k-space sampling. A new dedicated placement of the two-dimensional selective labeling pulse and an individually adjusted labeling delay time approved by the institutional review board were used. In 14 volunteers (eight men, six women; mean age, 28.8 years) who gave informed consent, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, vessel length, and subjective image quality were investigated. Differences between groups were analyzed with nonparametric tests (Wilcoxon, Pearson chi2). Radial imaging, as compared with Cartesian imaging, resulted in a significant reduction in the severity of motion artifacts, as well as an increase in SNR (26.9 vs 12.0, P < .05) in the coronary arteries and CNR (23.1 vs 8.8, P < .05) between the coronary arteries and the myocardium. A tendency toward improved vessel sharpness and vessel length was also found with radial imaging. Radial SSFP imaging is a promising technique for spin-labeling coronary MR angiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To study the interaction of T cell receptor with its ligand, a complex of a major histocompatibility complex molecule and a peptide, we derived H-2Kd-restricted cytolytic T lymphocyte clones from mice immunized with a Plasmodium berghei circumsporozoite peptide (PbCS) 252-260 (SYIPSAEKI) derivative containing photoreactive Nepsilon-[4-azidobenzoyl] lysine in place of Pro-255. This residue and Lys-259 were essential parts of the epitope recognized by these clones. Most of the clones expressed BV1S1A1 encoded beta chains along with specific complementary determining region (CDR) 3beta regions but diverse alpha chain sequences. Surprisingly, all T cell receptors were preferentially photoaffinity labeled on the alpha chain. For a representative T cell receptor, the photoaffinity labeled site was located in the Valpha C-strand. Computer modeling suggested the presence of a hydrophobic pocket, which is formed by parts of the Valpha/Jalpha C-, F-, and G-strands and adjacent CDR3alpha residues and structured to be able to avidly bind the photoreactive ligand side chain. We previously found that a T cell receptor specific for a PbCS peptide derivative containing this photoreactive side chain in position 259 similarly used a hydrophobic pocket located between the junctional CDR3 loops. We propose that this nonpolar domain in these locations allow T cell receptors to avidly and specifically bind epitopes containing non-peptidic side chains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional coronary magnetic resonance angiography (MRA) techniques display the coronary blood-pool along with the surrounding structures, including the myocardium, the ventricular and atrial blood-pool, and the great vessels. This representation of the coronary lumen is not directly analogous to the information provided by x-ray coronary angiography, in which the coronary lumen displayed by iodinated contrast agent is seen. Analogous "luminographic" data may be obtained using MR arterial spin tagging (projection coronary MRA) techniques. Such an approach was implemented using a 2D selective "pencil" excitation for aortic spin tagging in concert with a 3D interleaved segmented spiral imaging sequence with free-breathing, and real-time navigator technology. This technique allows for selective 3D visualization of the coronary lumen blood-pool, while signal from the surrounding structures is suppressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to SNR constraints, current "bright-blood" 3D coronary MRA approaches still suffer from limited spatial resolution when compared to conventional x-ray coronary angiography. Recent 2D fast spin-echo black-blood techniques maximize signal for coronary MRA at no loss in image spatial resolution. This suggests that the extension of black-blood coronary MRA with a 3D imaging technique would allow for a further signal increase, which may be traded for an improved spatial resolution. Therefore, a dual-inversion 3D fast spin-echo imaging sequence and real-time navigator technology were combined for high-resolution free-breathing black-blood coronary MRA. In-plane image resolution below 400 microm was obtained. Magn Reson Med 45:206-211, 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The competitiveness of businesses is increasingly dependent on their electronic networks with customers, suppliers, and partners. While the strategic and operational impact of external integration and IOS adoption has been extensively studied, much less attention has been paid to the organizational and technical design of electronic relationships. The objective of our longitudinal research project is the development of a framework for understanding and explaining B2B integration. Drawing on existing literature and empirical cases we present a reference model (a classification scheme for B2B Integration). The reference model comprises technical, organizational, and institutional levels to reflect the multiple facets of B2B integration. In this paper we onvestigate the current state of electronic collaboration in global supply chains focussing on the technical view. Using an indepth case analysis we identify five integration scenarios. In the subsequent confirmatory phase of the research we analyse 112 real-world company cases to validate these five integration scenarios. Our research advances and deepens existing studies by developing a B2B reference model, which reflects the current state of practice and is independent of specific implementation technologies. In the next stage of the research the emerging reference model will be extended to create an assessment model for analysing the maturity level of a given company in a specific supply chain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biofuels are considered as a promising substitute for fossil fuels when considering the possible reduction of greenhouse gases emissions. However limiting their impacts on potential benefits for reducing climate change is shortsighted. Global sustainability assessments are necessary to determine the sustainability of supply chains. We propose a new global criterion based framework enabling a comprehensive international comparison of bioethanol supply chains. The interest of this framework is that the selection of the sustainability indicators is qualified on three criterions: relevance, reliability and adaptability to the local context. Sustainability issues have been handled along environmental, social and economical issues. This new framework has been applied for a specific issue: from a Swiss perspective, is locally produced bioethanol in Switzerland more sustainable than imported from Brazil? Thanks to this framework integrating local context in its indicator definition, Brazilian production of bioethanol is shown as energy efficient and economically interesting for Brazil. From a strictly economic point of view, bioethanol production within Switzerland is not justified for Swiss consumption and questionable for the environmental issue. The social dimension is delicate to assess due to the lack of reliable data and is strongly linked to the agricultural policy in both countries. There is a need of establishing minimum sustainability criteria for imported bioethanol to avoid unwanted negative or leakage effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sequentially along B cell differentiation, the different classes of membrane Ig heavy chains associate with the Ig alpha/Ig beta heterodimer within the B cell receptor (BCR). Whether each Ig class conveys specific signals adapted to the corresponding differentiation stage remains debated. We investigated the impact of the forced expression of an IgA-class receptor throughout murine B cell differentiation by knocking in the human C alpha Ig gene in place of the S mu region. Despite expression of a functional BCR, homozygous mutant mice showed a partial developmental blockade at the pro-B/pre-BI and large pre-BII cell stages, with decreased numbers of small pre-BII cells. Beyond this stage, peripheral B cell compartments of reduced size developed and allowed specific antibody responses, whereas mature cells showed constitutive activation and a strong commitment to plasma cell differentiation. Secreted IgA correctly assembled into polymers, associated with the murine J chain, and was transported into secretions. In heterozygous mutants, cells expressing the IgA allele competed poorly with those expressing IgM from the wild-type allele and were almost undetectable among peripheral B lymphocytes, notably in gut-associated lymphoid tissues. Our data indicate that the IgM BCR is more efficient in driving early B cell education and in mucosal site targeting, whereas the IgA BCR appears particularly suited to promoting activation and differentiation of effector plasma cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cardiac-triggered free-breathing three-dimensional balanced fast field-echo projection magnetic resonance (MR) angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the renal arteries. For data acquisition during free breathing in eight healthy adults and seven consecutive patients with renal artery disease, real-time navigator technology was implemented. This technique allows high-spatial-resolution and high-contrast renal MR angiography and visualization of renal artery stenosis without exogenous contrast agent or breath hold. Initial promising results warrant larger clinical studies.