87 resultados para Safe Minimum Standard
em Université de Lausanne, Switzerland
Resumo:
A method of objectively determining imaging performance for a mammography quality assurance programme for digital systems was developed. The method is based on the assessment of the visibility of a spherical microcalcification of 0.2 mm using a quasi-ideal observer model. It requires the assessment of the spatial resolution (modulation transfer function) and the noise power spectra of the systems. The contrast is measured using a 0.2-mm thick Al sheet and Polymethylmethacrylate (PMMA) blocks. The minimal image quality was defined as that giving a target contrast-to-noise ratio (CNR) of 5.4. Several evaluations of this objective method for evaluating image quality in mammography quality assurance programmes have been considered on computed radiography (CR) and digital radiography (DR) mammography systems. The measurement gives a threshold CNR necessary to reach the minimum standard image quality required with regards to the visibility of a 0.2-mm microcalcification. This method may replace the CDMAM image evaluation and simplify the threshold contrast visibility test used in mammography quality.
Resumo:
Introduction New evidence from randomized controlled and etiology of fever studies, the availability of reliable RDT for malaria, and novel technologies call for revision of the IMCI strategy. We developed a new algorithm based on (i) a systematic review of published studies assessing the safety and appropriateness of RDT and antibiotic prescription, (ii) results from a clinical and microbiological investigation of febrile children aged <5 years, (iii) international expert IMCI opinions. The aim of this study was to assess the safety of the new algorithm among patients in urban and rural areas of Tanzania.Materials and Methods The design was a controlled noninferiority study. Enrolled children aged 2-59 months with any illness were managed either by a study clinician using the new Almanach algorithm (two intervention health facilities), or clinicians using standard practice, including RDT (two control HF). At day 7 and day 14, all patients were reassessed. Patients who were ill in between or not cured at day 14 were followed until recovery or death. Primary outcome was rate of complications, secondary outcome rate of antibiotic prescriptions.Results 1062 children were recruited. Main diagnoses were URTI 26%, pneumonia 19% and gastroenteritis (9.4%). 98% (531/541) were cured at D14 in the Almanach arm and 99.6% (519/521) in controls. Rate of secondary hospitalization was 0.2% in each. One death occurred in controls. None of the complications was due to withdrawal of antibiotics or antimalarials at day 0. Rate of antibiotic use was 19% in the Almanach arm and 84% in controls.Conclusion Evidence suggests that the new algorithm, primarily aimed at the rational use of drugs, is as safe as standard practice and leads to a drastic reduction of antibiotic use. The Almanach is currently being tested for clinician adherence to proposed procedures when used on paper or a mobile phone
Resumo:
BACKGROUND: Magnetic resonance imaging (MRI) of pacemakers is a relative contraindication because of the risks to the patient from potentially hazardous interactions between the MRI and the pacemaker system. Chest scans (ie, cardiac magnetic resonance scans) are of particular importance and higher risk. The previously Food and Drug Administration-approved magnetic resonance conditional system includes positioning restrictions, limiting the powerful utility of MRI. OBJECTIVE: To confirm the safety and effectiveness of a pacemaker system designed for safe whole body MRI without MRI scan positioning restrictions. METHODS: Primary eligibility criteria included standard dual-chamber pacing indications. Patients (n = 263) were randomized in a 2:1 ratio to undergo 16 chest and head scans at 1.5 T between 9 and 12 weeks postimplant (n = 177) or to not undergo MRI (n = 86) post-implant. Evaluation of the pacemaker system occurred immediately before, during (monitoring), and after MRI, 1-week post-MRI, and 1-month post-MRI, and similarly for controls. Primary end points measured the MRI-related complication-free rate for safety and compared pacing capture threshold between MRI and control subjects for effectiveness. RESULTS: There were no MRI-related complications during or after MRI in subjects undergoing MRI (n = 148). Differences in pacing capture threshold values from pre-MRI to 1-month post-MRI were minimal and similar between the MRI and control groups. CONCLUSIONS: This randomized trial demonstrates that the Advisa MRI pulse generator and CapSureFix MRI 5086MRI lead system is safe and effective in the 1.5 T MRI environment without positioning restrictions for MRI scans or limitations of body parts scanned.
Resumo:
BACKGROUND: Temporal arteritis is a very serious form of vasculitis. Early treatment is essential to avoid blindness. Surgical biopsy of the temporal artery is the gold standard for the diagnosis, but facial nerve injuries may occur. OBJECTIVE: To describe a simple and safe procedure for temporal artery biopsy. METHODS: Case report. RESULTS: A 62-year-old-woman with presumed temporal arteritis was referred. Precise localization of temporal arteries and its branches was obtained with color duplex ultrasonography. Arterial wall thickening (halo sign) was observed in the affected arterial segments. A frontal branch was precisely localized and infiltrated with 1% lidocaine. About 1 cm was removed for histopathologic examination. Thirty minutes was required to perform this outpatient procedure. The diagnosis of temporal arteritis was confirmed, and the patient was rapidly and successfully treated with prednisone. CONCLUSIONS: Color duplex ultrasonography allows precise localization of temporal arteries and its branches. This echocardiography-guided surgical procedure is easy and safe. Most dermatologic surgeons can perform it.
Resumo:
Nanotechnology is becoming part of our daily life in a wide range of products such as computers, bicycles, sunscreens or nanomedicines. While these applications already become reality, considerable work awaits scientists, engineers, and policy makers, who want such nanotechnological products to yield a maximum of benefit at a minimum of social, environmental, economic and (occupational) health cost. Considerable efforts for coordination and collaboration in research are needed if one wants to reach these goals in a reasonable time frame and an affordable price tag. This is recognized in Europe by the European Commission which funds not only research projects but also supports the coordination of research efforts. One of these coordination efforts is NanoImpactNet, a researcher-operated network, which started in 2008 promote scientific cross-talk across all disciplines on the health and environmental impact of nanomaterials. Stakeholders contribute to these activities, notably the definition of research and knowledge needs. Initial discussions in this domain focused on finding an agreement on common metrics, and which elements are needed for standardized approaches for hazard and exposure identification. There are many nanomaterial properties that may play a role. Hence, to gain the time needed to study this complex matter full of uncertainties, researchers and stakeholders unanimously called for simple, easy and fast risk assessment tools that can support decision making in this rapidly moving and growing domain. Today, several projects are starting or already running that will develop such assessment tools. At the same time, other projects investigate in depth which factors and material properties can lead to unwanted toxicity or exposure, what mechanisms are involved and how such responses can be predicted and modelled. A vision for the future is that once these factors, properties and mechanisms are understood, they can and will be accounted for in the development of new products and production processes following the idea of "Safety by Design". The promise of all these efforts is a future with nanomaterials where most of their risks are recognized and addressed before they even reach the market.
Resumo:
Background The distally based anterolateral thigh (ALT) flap is an interesting reconstructive solution for complex soft tissue defects of the knee. In spite of a low donor site morbidity and wide covering surface as well as arch of rotation, it has never gained popularity among reconstructive surgeons. Venous congestion and difficult flap dissection in the presence of a variable anatomy of the vascular pedicle are the possible reasons.Methods An anatomical study of 15 cadaver legs was performed to further clarify the blood supply of the distally based ALT. Our early experience with the use of preoperative angiography and a safe flap design modification that avoids distal intramuscular skeletonization of the vascular pedicle and includes a subcutaneous strip ranging from the distal end of the flap to the pivot point is presented.Results The distally based ALT presents a constant and reliable retrograde vascular contribution from the superior genicular artery. Preoperative angiography reliably identified and avoided critical Shieh Type II pedicled flaps. The preservation of a subcutaneous strip ranging from the distal flap end to the upper knee was associated with the absence of venous congestion in a short case series.Conclusions Preoperative angiography and a flap design modification are proposed to allow the safe transfer of the distally based ALT to reconstruct soft tissue defects of the knee.
Resumo:
Introduction: Renal transplantation is considered the treatment of choice for end-stage renal disease. However, the association of occlusive aorto-iliac disease and chronic renal failure is frequent and aorto-iliac reconstruction may be necessary prior to renal transplantation. This retrospective study reviews the results of this operative strategy.Material and Methods: Between January 2001 and June 2010, 309 patients underwent renal transplantation at our institution and 8 patients had prior aorto-iliac reconstruction using prosthetic material. There were 6 men and 2 women with a median age of 62 years (range 51-70). Five aorto-bifemoral and 2 aorto-bi-iliac bypasses were performed for stage II (n=5), stage IV (n=1) and aortic aneurysm (n=1). In one patient, iliac kissing stents and an ilio-femoral bypass were implanted. 4 cadaveric and 4 living donor renal transplantations were performed with an interval of 2 months to 10 years after revascularization.The results were analysed with respect of graft and patients survival. Differences between groups were tested by the log rank method.Results: No complications and no death occurred in the post-operative period. All bypasses remained patent during follow-up. The median time of post transplantation follow-up was 46 months for all patients and 27 months for patients with prior revascularization. In the revascularized group and control group, the graft and patient survival at 1 year were respectively 100%/96%, 100%/99% and at 5 years 86%/86%, 86%/94%, without significant differences between both groups.Discussion: Our results suggest that renal transplantation following prior aorto-iliac revascularisation with prosthetic material is safe and effective. Patients with end-stage renal disease and concomitant aorto-iliac disease should therefore be considered for renal transplantation. However, caution in the interpretation of the results is indicated due to the small sample size of our study.
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
From the 1st of January 2011, new conditions have been validated in which surgery for weight loss is borne by the basic insurance. These are very significant changes compared to the old criteria. Indeed, on one hand, patients with BMI > or = 35 kg/m2 may, without age limit and in the absence of comorbidities benefit from surgery without prior request to the medical council health insurance company concerned. On the other hand, the notion of a minimum casuistry is for the first time introduced in centers performing this type of intervention. In addition, certified centers are required to follow standard procedures for the patients' teaching and follow up.
Resumo:
BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.
Resumo:
SUMMARY: Coil displacement during endovascular coiling procedures may require coil retrieval in the context of flow limitation or thromboembolic risk. No standard recommended method of coil retrieval exists. We present a consecutive series of 14 patients with displaced coil during aneurysm coiling in whom the complication was effectively managed with the use of a stent retriever system. Two illustrative cases from the 14 are described, and technical notes are detailed regarding use of the technique. The use of stent retrievers presents a simple, safe, and effective choice for removal of prolapsed coils during aneurysm coiling.
Resumo:
A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.