8 resultados para SENSOR DEVELOPMENT

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent evidence suggests the existence of a hepatoportal vein glucose sensor, whose activation leads to enhanced glucose use in skeletal muscle, heart, and brown adipose tissue. The mechanism leading to this increase in whole body glucose clearance is not known, but previous data suggest that it is insulin independent. Here, we sought to further determine the portal sensor signaling pathway by selectively evaluating its dependence on muscle GLUT4, insulin receptor, and the evolutionarily conserved sensor of metabolic stress, AMP-activated protein kinase (AMPK). We demonstrate that the increase in muscle glucose use was suppressed in mice lacking the expression of GLUT4 in the organ muscle. In contrast, glucose use was stimulated normally in mice with muscle-specific inactivation of the insulin receptor gene, confirming independence from insulin-signaling pathways. Most importantly, the muscle glucose use in response to activation of the hepatoportal vein glucose sensor was completely dependent on the activity of AMPK, because enhanced hexose disposal was prevented by expression of a dominant negative AMPK in muscle. These data demonstrate that the portal sensor induces glucose use and development of hypoglycemia independently of insulin action, but by a mechanism that requires activation of the AMPK and the presence of GLUT4.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Summary Forests are key ecosystems of the earth and associated with a large range of functions. Many of these functions are beneficial to humans and are referred to as ecosystem services. Sustainable development requires that all relevant ecosystem services are quantified, managed and monitored equally. Natural resource management therefore targets the services associated with ecosystems. The main hypothesis of this thesis is that the spatial and temporal domains of relevant services do not correspond to a discrete forest ecosystem. As a consequence, the services are not quantified, managed and monitored in an equal and sustainable manner. The thesis aims were therefore to test this hypothesis, establish an improved conceptual approach and provide spatial applications for the relevant land cover and structure variables. The study was carried out in western Switzerland and based primarily on data from a countrywide landscape inventory. This inventory is part of the third Swiss national forest inventory and assesses continuous landscape variables based on a regular sampling of true colour aerial imagery. In addition, land cover variables were derived from Landsat 5 TM passive sensor data and land structure variables from active sensor data from a small footprint laserscanning system. The results confirmed the main hypothesis, as relevant services did not scale well with the forest ecosystem. Instead, a new conceptual approach for sustainable management of natural resources was described. This concept quantifies the services as a continuous function of the landscape, rather than a discrete function of the forest ecosystem. The explanatory landscape variables are therefore called continuous fields and the forest becomes a dependent and function-driven management unit. Continuous field mapping methods were established for land cover and structure variables. In conclusion, the discrete forest ecosystem is an adequate planning and management unit. However, monitoring the state of and trends in sustainability of services requires them to be quantified as a continuous function of the landscape. Sustainable natural resource management iteratively combines the ecosystem and gradient approaches. Résumé Les forêts sont des écosystèmes-clés de la terre et on leur attribue un grand nombre de fonctions. Beaucoup de ces fonctions sont bénéfiques pour l'homme et sont nommées services écosystémiques. Le développement durable exige que ces services écosystémiques soient tous quantifiés, gérés et surveillés de façon égale. La gestion des ressources naturelles a donc pour cible les services attribués aux écosystèmes. L'hypothèse principale de cette thèse est que les domaines spatiaux et temporels des services attribués à la forêt ne correspondent pas à un écosystème discret. Par conséquent, les services ne sont pas quantifiés, aménagés et surveillés d'une manière équivalente et durable. Les buts de la thèse étaient de tester cette hypothèse, d'établir une nouvelle approche conceptuelle de la gestion des ressources naturelles et de préparer des applications spatiales pour les variables paysagères et structurelles appropriées. L'étude a été menée en Suisse occidentale principalement sur la base d'un inventaire de paysage à l'échelon national. Cet inventaire fait partie du troisième inventaire forestier national suisse et mesure de façon continue des variables paysagères sur la base d'un échantillonnage régulier sur des photos aériennes couleur. En outre, des variables de couverture ? terrestre ont été dérivées des données d'un senseur passif Landsat 5 TM, ainsi que des variables structurelles, dérivées du laserscanning, un senseur actif. Les résultats confirment l'hypothèse principale, car l'échelle des services ne correspond pas à celle de l'écosystème forestier. Au lieu de cela, une nouvelle approche a été élaborée pour la gestion durable des ressources naturelles. Ce concept représente les services comme une fonction continue du paysage, plutôt qu'une fonction discrète de l'écosystème forestier. En conséquence, les variables explicatives de paysage sont dénommées continuous fields et la forêt devient une entité dépendante, définie par la fonction principale du paysage. Des méthodes correspondantes pour la couverture terrestre et la structure ont été élaborées. En conclusion, l'écosystème forestier discret est une unité adéquate pour la planification et la gestion. En revanche, la surveillance de la durabilité de l'état et de son évolution exige que les services soient quantifiés comme fonction continue du paysage. La gestion durable des ressources naturelles joint donc l'approche écosystémique avec celle du gradient de manière itérative.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the preceding article, we demonstrated that activation of the hepatoportal glucose sensor led to a paradoxical development of hypoglycemia that was associated with increased glucose utilization by a subset of tissues. In this study, we tested whether GLUT2 plays a role in the portal glucose-sensing system that is similar to its involvement in pancreatic beta-cells. Awake RIPGLUT1 x GLUT2-/- and control mice were infused with glucose through the portal (Po-) or the femoral (Fe-) vein for 3 h at a rate equivalent to the endogenous glucose production rate. Blood glucose and plasma insulin concentrations were continuously monitored. Glucose turnover, glycolysis, and glycogen synthesis rates were determined by the 3H-glucose infusion technique. We showed that portal glucose infusion in RIPGLUT1 x GLUT24-/- mice did not induce the hypoglycemia observed in control mice but, in contrast, led to a transient hyperglycemic state followed by a return to normoglycemia; this glycemic pattern was similar to that observed in control Fe-mice and RIPGLUT1 x GLUT2-/- Fe-mice. Plasma insulin profiles during the infusion period were similar in control and RIPGLUT1 x GLUT2-/- Po- and Fe-mice. The lack of hypoglycemia development in RIPGLUT1 x GLUT2-/- mice was not due to the absence of GLUT2 in the liver. Indeed, reexpression by transgenesis of this transporter in hepatocytes did not restore the development of hypoglycemia after initiating portal vein glucose infusion. In the absence of GLUT2, glucose turnover increased in Po-mice to the same extent as that in RIPGLUT1 x GLUT2-/- or control Fe-mice. Finally, co-infusion of somatostatin with glucose prevented development of hypoglycemia in control Po-mice, but it did not affect the glycemia or insulinemia of RIPGLUT1 x GLUT2-/- Po-mice. Together, our data demonstrate that GLUT2 is required for the function of the hepatoportal glucose sensor and that somatostatin could inhibit the glucose signal by interfering with GLUT2-expressing sensing units.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The NALP3 inflammasome functions as a sensor of danger signals and triggers processing and release of IL-1b. Mutations of NALP3 are responsible for the cryopyrin associated periodic syndromes, a group of autoinflammatory disorders that respond to IL1 inhibition. Genetic studies have also linked NALP3 to hypertension in man, but the mechanism is not understood. The aim of this study is to investigate the role of NAPL3 inflammasome in the development of hypertension in an animal model. Design and Method: Six-week old male WT and NALP3 KO mice were used for generating a two-kidney, one clip (2K1C) renovascular hypertension. A U-shaped stainless steel clip (O^ ¼0.12mm) was placed on left renal artery under anaesthesia. The same surgery without clipping was performed in sham mice. At week 6 and 12 after the clipping, intra-arterial blood pressure (BP) was measured in conscious mice. Blood was collected for plasma renin analysis. Heart and kidney were excised and stored for molecular and morphological examinations. n¼5-6 mice per group. Data are mean_SEM. Results: Mean BP was significantly increased at week 6 and 12 in WT-2K1C mice compared to WT-sham group (MBPweek6: 138_2 vs.124_3 mmHg, p<0.01 and MBPweek12: 141_5 vs.122_3 mmHg, p<0.01) followed with an significant increase in heart weight (HW) and a decrease in clipped kidney weight indices in WT-2K1C mice compared to the WT-sham (HW/ BWweek6: 4.65_0.04 vs. 3.99_0.12 mg/g, p<0.001 and HW/BWweek12: 4.94_0.15 vs. 4.22_0.12 mg/g, p<0.001). Interestingly, NALP3 KO-2K1C mice did not develop hypertension. The MBP of KO-2K1C mice was comparable to the KO-sham (MBPweek6: 122_3 vs. 119_3 mmHg, p>0.05 and MBPweek6: 128_5 vs.122_4 mmHg, p>0.05). There was also no significant change in heart and kidney weight indices between KO- 2K1C and KO-sham mice. Conclusion: The preliminary results suggest that absence of NALP3 protects mice from the development of renin-dependent hypertension. Further molecular and morphological examinations are ongoing for the confirmation and mechanism explanation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of a whole-cell based sensor for arsenite detection coupling biological engineering and electrochemical techniques is presented. This strategy takes advantage of the natural Escherichia coli resistance mechanism against toxic arsenic species, such as arsenite, which consists of the selective intracellular recognition of arsenite and its pumping out from the cell. A whole-cell based biosensor can be produced by coupling the intracellular recognition of arsenite to the generation of an electrochemical signal. Hereto, E. coli was equipped with a genetic circuit in which synthesis of beta-galactosidase is under control of the arsenite-derepressable arsR-promoter. The E. coli reporter strain was filled in a microchip containing 16 independent electrochemical cells (i.e. two-electrode cell), which was then employed for analysis of tap and groundwater samples. The developed arsenic-sensitive electrochemical biochip is easy to use and outperforms state-of-the-art bacterial bioreporters assays specifically in its simplicity and response time, while keeping a very good limit of detection in tap water, i.e. 0.8ppb. Additionally, a very good linear response in the ranges of concentration tested (0.94ppb to 3.75ppb, R(2)=0.9975 and 3.75 ppb to 30ppb, R(2)=0.9991) was obtained, complying perfectly with the acceptable arsenic concentration limits defined by the World Health Organization for drinking water samples (i.e. 10ppb). Therefore, the proposed assay provides a very good alternative for the portable quantification of As (III) in water as corroborated by the analysis of natural groundwater samples from Swiss mountains, which showed a very good agreement with the results obtained by atomic absorption spectroscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proteins can switch between different conformations in response to stimuli, such as pH or temperature variations, or to the binding of ligands. Such plasticity and its kinetics can have a crucial functional role, and their characterization has taken center stage in protein research. As an example, Topoisomerases are particularly interesting enzymes capable of managing tangled and supercoiled double-stranded DNA, thus facilitating many physiological processes. In this work, we describe the use of a cantilever-based nanomotion sensor to characterize the dynamics of human topoisomerase II (Topo II) enzymes and their response to different kinds of ligands, such as ATP, which enhance the conformational dynamics. The sensitivity and time resolution of this sensor allow determining quantitatively the correlation between the ATP concentration and the rate of Topo II conformational changes. Furthermore, we show how to rationalize the experimental results in a comprehensive model that takes into account both the physics of the cantilever and the dynamics of the ATPase cycle of the enzyme, shedding light on the kinetics of the process. Finally, we study the effect of aclarubicin, an anticancer drug, demonstrating that it affects directly the Topo II molecule inhibiting its conformational changes. These results pave the way to a new way of studying the intrinsic dynamics of proteins and of protein complexes allowing new applications ranging from fundamental proteomics to drug discovery and development and possibly to clinical practice.