108 resultados para Pressure-indicating sensor film
em Université de Lausanne, Switzerland
Resumo:
Genetic determinants of blood pressure are poorly defined. We undertook a large-scale, gene-centric analysis to identify loci and pathways associated with ambulatory systolic and diastolic blood pressure. We measured 24-hour ambulatory blood pressure in 2020 individuals from 520 white European nuclear families (the Genetic Regulation of Arterial Pressure of Humans in the Community Study) and genotyped their DNA using the Illumina HumanCVD BeadChip array, which contains ≈50 000 single nucleotide polymorphisms in >2000 cardiovascular candidate loci. We found a strong association between rs13306560 polymorphism in the promoter region of MTHFR and CLCN6 and mean 24-hour diastolic blood pressure; each minor allele copy of rs13306560 was associated with 2.6 mm Hg lower mean 24-hour diastolic blood pressure (P=1.2×10(-8)). rs13306560 was also associated with clinic diastolic blood pressure in a combined analysis of 8129 subjects from the Genetic Regulation of Arterial Pressure of Humans in the Community Study, the CoLaus Study, and the Silesian Cardiovascular Study (P=5.4×10(-6)). Additional analysis of associations between variants in gene ontology-defined pathways and mean 24-hour blood pressure in the Genetic Regulation of Arterial Pressure of Humans in the Community Study showed that cell survival control signaling cascades could play a role in blood pressure regulation. There was also a significant overrepresentation of rare variants (minor allele frequency: <0.05) among polymorphisms showing at least nominal association with mean 24-hour blood pressure indicating that a considerable proportion of its heritability may be explained by uncommon alleles. Through a large-scale gene-centric analysis of ambulatory blood pressure, we identified an association of a novel variant at the MTHFR/CLNC6 locus with diastolic blood pressure and provided new insights into the genetic architecture of blood pressure.
Resumo:
This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.
Resumo:
The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.
Resumo:
Purpose: In vitro studies in porcine eyes have demonstrated a good correlation between induced intraocular pressure variations and corneal curvature changes, using a contact lens with an embedded microfabricated strain gauge. Continuous 24 hour-intraocular pressure (IOP) monitoring to detect large diurnal fluctuation is currently an unmet clinical need. The aims of this study is to evaluate precision of signal transmission and biocompatibility of 24 hour contact lens sensor wear (SENSIMED Triggerfish®) in humans. Methods: After full eye examination in 10 healthy volunteers, a 8.7 mm radius contact lens sensor and an orbital bandage containing a loop antenna were applied and connected to a portable recorder. Best corrected visual acuity and position, lubrication status and mobility of the sensor were assessed after 5 and 30 minutes, 4, 7 and 24 hours. Subjective comfort was scored and activities documented in a logbook. After sensor removal full eye examination was repeated, and the registration signal studied. Results: The comfort score was high and did not fluctuate significantly, except at the 7 hour-visit. The mobility of the contact lens was minimal but its lubrication remained good. Best corrected visual acuity was significantly reduced during the sensor wear and immediately after its removal. Three patients developed mild corneal staining. In all but one participant we obtained a registration IOP curve with visible ocular pulse amplitude. Conclusions: This 24 hour-trial confirmed the functionality and biocompatibility of SENSIMED Triggerfish® wireless contact lens sensor for IOP-fluctuation monitoring in volunteers. Further studies with a range of different contact lens sensor radii are indicated.
Resumo:
Activation of the hepatoportal glucose sensors by portal glucose infusion leads to increased glucose clearance and induction of hypoglycemia. Here, we investigated whether glucagon-like peptide-1 (GLP-1) could modulate the activity of these sensors. Mice were therefore infused with saline (S-mice) or glucose (P-mice) through the portal vein at a rate of 25 mg/kg. min. In P-mice, glucose clearance increased to 67.5 +/- 3.7 mg/kg. min as compared with 24.1 +/- 1.5 mg/kg. min in S-mice, and glycemia decreased from 5.0 +/- 0.1 to 3.3 +/- 0.1 mmol/l at the end of the 3-h infusion period. Coinfusion of GLP-1 with glucose into the portal vein at a rate of 5 pmol/kg. min (P-GLP-1 mice) did not increase the glucose clearance rate (57.4 +/- 5.0 ml/kg. min) and hypoglycemia (3.8 +/- 0.1 mmol/l) observed in P-mice. In contrast, coinfusion of glucose and the GLP-1 receptor antagonist exendin-(9-39) into the portal vein at a rate of 0.5 pmol/kg. min (P-Ex mice) reduced glucose clearance to 36.1 +/- 2.6 ml/kg. min and transiently increased glycemia to 9.2 +/- 0.3 mmol/l at 60 min of infusion before it returned to the fasting level (5.6 +/- 0.3 mmol/l) at 3 h. When glucose and exendin-(9-39) were infused through the portal and femoral veins, respectively, glucose clearance increased to 70.0 +/- 4.6 ml/kg. min and glycemia decreased to 3.1 +/- 0.1 mmol/l, indicating that exendin-(9-39) has an effect only when infused into the portal vein. Finally, portal vein infusion of glucose in GLP-1 receptor(-/-) mice failed to increase the glucose clearance rate (26.7 +/- 2.9 ml/kg. min). Glycemia increased to 8.5 +/- 0.5 mmol/l at 60 min and remained elevated until the end of the glucose infusion (8.2 +/- 0.4 mmol/l). Together, our data show that the GLP-1 receptor is part of the hepatoportal glucose sensor and that basal fasting levels of GLP-1 sufficiently activate the receptor to confer maximum glucose competence to the sensor. These data demonstrate an important extrapancreatic effect of GLP-1 in the control of glucose homeostasis.
Resumo:
OBJECT: Cerebrovascular pressure reactivity is the ability of cerebral vessels to respond to changes in transmural pressure. A cerebrovascular pressure reactivity index (PRx) can be determined as the moving correlation coefficient between mean intracranial pressure (ICP) and mean arterial blood pressure. METHODS: The authors analyzed a database consisting of 398 patients with head injuries who underwent continuous monitoring of cerebrovascular pressure reactivity. In 298 patients, the PRx was compared with a transcranial Doppler ultrasonography assessment of cerebrovascular autoregulation (the mean index [Mx]), in 17 patients with the PET-assessed static rate of autoregulation, and in 22 patients with the cerebral metabolic rate for O(2). Patient outcome was assessed 6 months after injury. RESULTS: There was a positive and significant association between the PRx and Mx (R(2) = 0.36, p < 0.001) and with the static rate of autoregulation (R(2) = 0.31, p = 0.02). A PRx > 0.35 was associated with a high mortality rate (> 50%). The PRx showed significant deterioration in refractory intracranial hypertension, was correlated with outcome, and was able to differentiate patients with good outcome, moderate disability, severe disability, and death. The graph of PRx compared with cerebral perfusion pressure (CPP) indicated a U-shaped curve, suggesting that too low and too high CPP was associated with a disturbance in pressure reactivity. Such an optimal CPP was confirmed in individual cases and a greater difference between current and optimal CPP was associated with worse outcome (for patients who, on average, were treated below optimal CPP [R(2) = 0.53, p < 0.001] and for patients whose mean CPP was above optimal CPP [R(2) = -0.40, p < 0.05]). Following decompressive craniectomy, pressure reactivity initially worsened (median -0.03 [interquartile range -0.13 to 0.06] to 0.14 [interquartile range 0.12-0.22]; p < 0.01) and improved in the later postoperative course. After therapeutic hypothermia, in 17 (70.8%) of 24 patients in whom rewarming exceeded the brain temperature threshold of 37 degrees C, ICP remained stable, but the average PRx increased to 0.32 (p < 0.0001), indicating significant derangement in cerebrovascular reactivity. CONCLUSIONS: The PRx is a secondary index derived from changes in ICP and arterial blood pressure and can be used as a surrogate marker of cerebrovascular impairment. In view of an autoregulation-guided CPP therapy, a continuous determination of a PRx is feasible, but its value has to be evaluated in a prospective controlled trial.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.
Resumo:
BACKGROUND: Because ambulatory blood pressure monitoring (ABPM) is not available everywhere, the objective of the study was to determine whether nurse-measured blood pressure could be an acceptable substitute to ABPM. METHODS: We analyzed the data of 2385 consecutive patients referred to our hypertension clinic for the performance of ABPM. Before ambulatory monitoring was performed, a nurse-measured BP was obtained three times using a Y-tube connecting the sphygmomanometer and the recorder. We compared the mean value of the three nurse-measured blood pressures with that of the 12h daytime ambulatory monitoring, considered as the reference. RESULTS: The difference between the nurse-measured and the ambulatory blood pressure was small but statistically significant, indicating that nurse-measured blood pressure tends to overestimate both diastolic and systolic blood pressure. The difference between the nurse blood pressure and ABPM was greater among treated hypertensive patients than untreated patients. To diagnose hypertension, defined as a blood pressure of over 140/90mmHg by ABPM, the positive predictive value of the nurse blood pressure was 0.81 and the negative predictive value 0.63. However, these predictive values could be improved with less stringent cut-off values of blood pressure. Thus, for a diastolic blood pressure above 100mmHg, the positive predictive value of nurse blood pressure was 0.55 and the negative predictive value 0.91. These figures were relatively similar for previously treated and untreated patients. CONCLUSION: Nurse blood pressure is less accurate than ABPM in diagnosing hypertension, defined as a blood pressure of over 140/90mmHg. It could, however, be an acceptable substitute, especially to exclude people who do not need to be treated, in situations where lower resources require a less rigorous definition of hypertension.
Resumo:
Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.
Resumo:
Although age-dependent effects on blood pressure (BP) have been reported, they have not been systematically investigated in large-scale genome-wide association studies (GWASs). We leveraged the infrastructure of three well-established consortia (CHARGE, GBPgen, and ICBP) and a nonstandard approach (age stratification and metaregression) to conduct a genome-wide search of common variants with age-dependent effects on systolic (SBP), diastolic (DBP), mean arterial (MAP), and pulse (PP) pressure. In a two-staged design using 99,241 individuals of European ancestry, we identified 20 genome-wide significant (p ≤ 5 × 10(-8)) loci by using joint tests of the SNP main effect and SNP-age interaction. Nine of the significant loci demonstrated nominal evidence of age-dependent effects on BP by tests of the interactions alone. Index SNPs in the EHBP1L1 (DBP and MAP), CASZ1 (SBP and MAP), and GOSR2 (PP) loci exhibited the largest age interactions, with opposite directions of effect in the young versus the old. The changes in the genetic effects over time were small but nonnegligible (up to 1.58 mm Hg over 60 years). The EHBP1L1 locus was discovered through gene-age interactions only in whites but had DBP main effects replicated (p = 8.3 × 10(-4)) in 8,682 Asians from Singapore, indicating potential interethnic heterogeneity. A secondary analysis revealed 22 loci with evidence of age-specific effects (e.g., only in 20 to 29-year-olds). Age can be used to select samples with larger genetic effect sizes and more homogenous phenotypes, which may increase statistical power. Age-dependent effects identified through novel statistical approaches can provide insight into the biology and temporal regulation underlying BP associations.
Resumo:
BACKGROUND: Prevalence of hypertension in HIV infection is high, and information on blood pressure control in HIV-infected individuals is insufficient. We modeled blood pressure over time and the risk of cardiovascular events in hypertensive HIV-infected individuals. METHODS: All patients from the Swiss HIV Cohort Study with confirmed hypertension (systolic or diastolic blood pressure above 139 or 89 mm Hg on 2 consecutive visits and presence of at least 1 additional cardiovascular risk factor) between April 1, 2000 and March 31, 2011 were included. Patients with previous cardiovascular events, already on antihypertensive drugs, and pregnant women were excluded. Change in blood pressure over time was modeled using linear mixed models with repeated measurement. RESULTS: Hypertension was diagnosed in 2595 of 10,361 eligible patients. Of those, 869 initiated antihypertensive treatment. For patients treated for hypertension, we found a mean (95% confidence interval) decrease in systolic and diastolic blood pressure of -0.82 (-1.06 to -0.58) mm Hg and -0.89 (-1.05 to -0.73) mm Hg/yr, respectively. Factors associated with a decline in systolic blood pressure were baseline blood pressure, presence of chronic kidney disease, cardiovascular events, and the typical risk factors for cardiovascular disease. In patients with hypertension, increase in systolic blood pressure [(hazard ratio 1.18 (1.06 to 1.32) per 10 mm Hg increase], total cholesterol, smoking, age, and cumulative exposure to protease inhibitor-based and triple nucleoside regimens were associated with cardiovascular events. CONCLUSIONS: Insufficient control of hypertension was associated with increased risk of cardiovascular events indicating the need for improved management of hypertension in HIV-infected individuals.
Resumo:
An eclogite facies meta-plagiogranite from the Lanzo massif (western Alps, Italy) contains crystals of zircon intimately associated with allanite. Zircon displays different microtextures ranging from pristine, euhedral, and magmatic to fractured, porous varieties with mosaic zoning, and pervasive recrystallization into euhedral microcrystals. Fractures and voids in the recrystallized zircon microcrystals are mainly filled by high-pressure Na-rich pyroxene. Electron backscattered diffraction analysis revealed a similar crystallographic orientation for primary magmatic zircon crystals and microcrystals, with less than 2 degrees misorientation among neighboring microdomains. The textural change is coupled with chemical and isotopic modifications: recrystallized zircon domains contain significantly less Th and light- to mid-REE, but are richer in Sr than magmatic zircon crystals. Magmatic zircon preserves the protolith U-Pb age of 163.5 +/- 1.7 Ma, whereas zircon microcrystals have a mean age of 55 +/- 1 Ma. The coexisting allanite also contains inclusions of Na-rich pyroxene and has chemical features (elevated Sr and Ni contents and lack of Eu anomaly) indicating formation at high pressure. Despite being associated texturally with zircon, allanite yields a younger Th-Pb age of 46.5 +/- 3.0 Ma, suggesting that the Lanzo unit remained at relatively high pressure conditions for similar to 8 m.y. Zircon recrystallization proceeded with volume reduction and loss of material to an alkaline metamorphic fluid that acted as the agent for a coupled dissolution-reprecipitation process. Recrystallization occurred with minimum transport, in a low-strain environment, and was not significantly enhanced by metamictization. The source of the fluid for zircon recrystallization is most probably related to prograde devolatilization reactions in the surrounding serpentinite.
Resumo:
OBJECTIVE: To evaluate the feasibility and effects of non-invasive pressure support ventilation (NIV) on the breathing pattern in infants developing respiratory failure after extubation. DESIGN: Prospective pilot clinical study; each patient served as their own control. SETTING: A nine-bed paediatric intensive care unit of a tertiary university hospital. PATIENTS: Six patients (median age 5 months, range 0.5-7 months; median weight 4.2 kg, range 3.8-5.1 kg) who developed respiratory failure after extubation. INTERVENTIONS: After a period of spontaneous breathing (SB), children who developed respiratory failure were treated with NIV. MEASUREMENTS AND RESULTS: Measurements included clinical dyspnoea score (DS), blood gases and oesophageal pressure recordings, which were analysed for respiratory rate (RR), oesophageal inspiratory pressure swing (dPes) and oesophageal pressure-time product (PTPes). All data were collected during both periods (SB and NIV). When comparing NIV with SB, DS was reduced by 44% (P < 0.001), RR by 32% (P < 0.001), dPes by 45% (P < 0.01) and PTPes by 57% (P < 0.001). A non-significant trend for decrease in PaCO(2) was observed. CONCLUSION: In these infants, non-invasive pressure support ventilation with turbine flow generator induced a reduction of breathing frequency, dPes and PTPes, indicating reduced load of the inspiratory muscles. NIV can be used with some benefits in infants with respiratory failure after extubation.
Resumo:
Hypertension is an important determinant of cardiovascular morbidity and mortality and has a substantial heritability, which is likely of polygenic origin. The aim of this study was to assess to what extent multiple common genetic variants contribute to blood pressure regulation in both adults and children and to assess overlap in variants between different age groups, using genome-wide profiling. Single nucleotide polymorphism sets were defined based on a meta-analysis of genome-wide association studies on systolic blood pressure and diastolic blood pressure performed by the Cohort for Heart and Aging Research in Genome Epidemiology (n=29 136), using different P value thresholds for selecting single nucleotide polymorphisms. Subsequently, genetic risk scores for systolic blood pressure and diastolic blood pressure were calculated in an independent adult population (n=2072) and a child population (n=1034). The explained variance of the genetic risk scores was evaluated using linear regression models, including sex, age, and body mass index. Genetic risk scores, including also many nongenome-wide significant single nucleotide polymorphisms, explained more of the variance than scores based only on very significant single nucleotide polymorphisms in adults and children. Genetic risk scores significantly explained ≤1.2% (P=9.6*10(-8)) of the variance in adult systolic blood pressure and 0.8% (P=0.004) in children. For diastolic blood pressure, the variance explained was similar in adults and children (1.7% [P=8.9*10(-10)] and 1.4% [P=3.3*10(-5)], respectively). These findings suggest the presence of many genetic loci with small effects on blood pressure regulation both in adults and children, indicating also a (partly) common polygenic regulation of blood pressure throughout different periods of life.