80 resultados para FIA-ESI-IT-MS-MS
em Université de Lausanne, Switzerland
Resumo:
Blood doping involves the use of products that enhance the uptake, transport, or delivery of oxygen to the blood. One approach uses artificial oxygen carriers, known as hemoglobin-based oxygen carriers (HBOCs). This study describes an analytical strategy based on CE for detecting intact HBOCs in plasma samples collected for doping control. On-capillary detection was performed by UV/Vis at 415 nm, which offered detection selectivity for hemoproteins (such as hemoglobin and HBOCs). On-line ESI-MS detection with a TOF analyzer was further used to provide accurate masses on CE peaks and to confirm the presence of HBOCs. An immunodepletion sample preparation step was mandatory prior to analysis, in order to remove most abundant proteins that interfered with CE separation and altered the ESI process. This analytical method was successfully applied to plasma samples enriched with Oxyglobin, a commercially available HBOC used for veterinary purposes. Detection limits of 0.20 and 0.45 g/dL were achieved in plasma for CE-UV/Vis at 415 nm and CE-ESI-TOF/MS, respectively.
Resumo:
CE is a powerful analytical tool used to separate intact biomolecules such as proteins. The coupling of CE with TOF/MS produces a very promising method that can be used to detect and identify proteins in different matrices. This paper describes an efficient, rapid, and simple CE-ESI-TOF/MS procedure for the analysis of endogenous human growth hormone and recombinant human growth hormone without sample preparation. Operational factors were optimized using an experimental design, and the method was successfully applied to distinguish human growth hormone and recombinant human growth hormone in unknown samples.
Resumo:
To study the stress-induced effects caused by wounding under a new perspective, a metabolomic strategy based on HPLC-MS has been devised for the model plant Arabidopsis thaliana. To detect induced metabolites and precisely localise these compounds among the numerous constitutive metabolites, HPLC-MS analyses were performed in a two-step strategy. In a first step, rapid direct TOF-MS measurements of the crude leaf extract were performed with a ballistic gradient on a short LC-column. The HPLC-MS data were investigated by multivariate analysis as total mass spectra (TMS). Principal components analysis (PCA) and hierarchical cluster analysis (HCA) on principal coordinates were combined for data treatment. PCA and HCA demonstrated a clear clustering of plant specimens selecting the highest discriminating ions given by the complete data analysis, leading to the specific detection of discrete-induced ions (m/z values). Furthermore, pool constitution with plants of homogeneous behaviour was achieved for confirmatory analysis. In this second step, long high-resolution LC profilings on an UPLC-TOF-MS system were used on pooled samples. This allowed to precisely localise the putative biological marker induced by wounding and by specific extraction of accurate m/z values detected in the screening procedure with the TMS spectra.
Resumo:
An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.
Resumo:
Introduction: The general strategy to perform anti-doping analysis starts with a screening followed by a confirmatory step when a sample is suspected to be positive. The screening step should be fast, generic and able to highlight any sample that may contain a prohibited substance by avoiding false negative and reducing false positive results. The confirmatory step is a dedicated procedure comprising a selective sample preparation and detection mode. Aim: The purpose of the study is to develop rapid screening and selective confirmatory strategies to detect and identify 103 doping agents in urine. Methods: For the screening, urine samples were simply diluted by a factor 2 with ultra-pure water and directly injected ("dilute and shoot") in the ultrahigh- pressure liquid chromatography (UHPLC). The UHPLC separation was performed in two gradients (ESI positive and negative) from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. The gradient analysis time is 9 min including 3 min reequilibration. Analytes detection was performed in full scan mode on a quadrupole time-of-flight (QTOF) mass spectrometer by acquiring the exact mass of the protonated (ESI positive) or deprotonated (ESI negative) molecular ion. For the confirmatory analysis, urine samples were extracted on SPE 96-well plate with mixed-mode cation (MCX) for basic and neutral compounds or anion exchange (MAX) sorbents for acidic molecules. The analytes were eluted in 3 min (including 1.5 min reequilibration) with a S1-25 Ann Toxicol Anal. 2009; 21(S1) Abstracts gradient from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. Analytes confirmation was performed in MS and MS/MS mode on a QTOF mass spectrometer. Results: In the screening and confirmatory analysis, basic and neutral analytes were analysed in the positive ESI mode, whereas acidic compounds were analysed in the negative mode. The analyte identification was based on retention time (tR) and exact mass measurement. "Dilute and shoot" was used as a generic sample treatment in the screening procedure, but matrix effect (e.g., ion suppression) cannot be avoided. However, the sensitivity was sufficient for all analytes to reach the minimal required performance limit (MRPL) required by the World Anti Doping Agency (WADA). To avoid time-consuming confirmatory analysis of false positive samples, a pre-confirmatory step was added. It consists of the sample re-injection, the acquisition of MS/MS spectra and the comparison to reference material. For the confirmatory analysis, urine samples were extracted by SPE allowing a pre-concentration of the analyte. A fast chromatographic separation was developed as a single analyte has to be confirmed. A dedicated QTOF-MS and MS/MS acquisition was performed to acquire within the same run a parallel scanning of two functions. Low collision energy was applied in the first channel to obtain the protonated molecular ion (QTOF-MS), while dedicated collision energy was set in the second channel to obtain fragmented ions (QTOF-MS/MS). Enough identification points were obtained to compare the spectra with reference material and negative urine sample. Finally, the entire process was validated and matrix effects quantified. Conclusion: Thanks to the coupling of UHPLC with the QTOF mass spectrometer, high tR repeatability, sensitivity, mass accuracy and mass resolution over a broad mass range were obtained. The method was sensitive, robust and reliable enough to detect and identify doping agents in urine. Keywords: screening, confirmatory analysis, UHPLC, QTOF, doping agents
Resumo:
BACKGROUND: Direct-infusion ESI-MS/MS is a powerful approach for the identification of substances in complex mixtures. The aim of this work was to investigate its applicability to the toxicological screening of blood samples. A simple protein precipitation was used, followed by a 15 min infusion of the extract in the mass spectrometer. RESULTS: The application of the procedure to commercial quality controls and authentic post-mortem blood samples demonstrated that the direct-infusion ESI-MS/MS approach enables the simultaneous identification of substances that require different chromatographic conditions. However, poor sensitivity was observed for benzodiazepine, amphetamines and opiate compounds. CONCLUSION: Considering the facile implementation and positive performance of direct-infusion ESI-MS/MS, this approach may to be a valuable complementary technique for systematic toxicological analysis procedures.
Resumo:
The conditions for the analysis of selected doping substances by UHPSFC-MS/MS were optimized to ensure suitable peak shapes and maximized MS responses. A representative mixture of 31 acidic and basic doping agents was analyzed, in both ESI+ and ESI- modes. The best compromise for all compounds in terms of MS sensitivity and chromatographic performance was obtained when adding 2% water and 10mM ammonium formate in the CO2/MeOH mobile phase. Beside mobile phase, the nature of the make-up solvent added for interfacing UHPSFC with MS was also evaluated. Ethanol was found to be the best candidate as it was able to compensate for the negative effect of 2% water addition in ESI- mode and provided a suitable MS response for all doping agents. Sensitivity of the optimized UHPSFC-MS/MS method was finally assessed and compared to the results obtained in conventional UHPLC-MS/MS. Sensitivity was improved by 5-100-fold in UHPSFC-MS/MS vs. UHPLC-MS/MS for 56% of compounds, while only one compound (bumetanide) offered a significantly higher MS response (4-fold) under UHPLC-MS/MS conditions. In the second paper of this series, the optimal conditions for UHPSFC-MS/MS analysis will be employed to screen >100 doping agents in urine matrix and results will be compared to those obtained by conventional UHPLC-MS/MS.
Resumo:
Background: Infection with EBV and a lack in vitamin D may be important environmental triggers of MS. 1,25-(OH)2D3 mediates a shift of antigen presenting cells (APC) and CD4+ T cells to a less inflammatory profile. Although CD8+ T cells do express the vitamin D receptor, a direct effect of 1,25(OH)2D3 on these cells has not been demonstrated until now. Since CD8+ T cells are important immune mediators of the inflammatory response in MS, we examined whether vitamin D directly affects the CD8+ T cell response, and more specifically if it modulates the EBV-specific CD8+ T cell response. Material and Methods: To explore whether the vitamin D status may influence the pattern of the EBV-specific CD8+ T cell response, PBMC of 10 patients with early MS and 10 healthy controls (HC) were stimulated with a pool of immunodominant 8-10 mer peptide epitopes known to elicit CD8+ T cell responses. PBMC were stimulated with this EBV CD8 peptide pool, medium (negative control) or anti- CD3/anti-CD28 beads (positive control). The following assays were performed: ELISPOT to assess the secretion of IFN-gamma by T cells in general; cytometric beads array (CBA) and ELISA to determine whichcytokines were released by EBV-specific CD8+ T cells after six days of culture; and intracellular cytokine staining assay to determine by which subtype of T cells secreted given cytokines. To examine whether vitamin D could directly modulate CD8+ T cell immune responses, we depleted CD4+ T cells using negative selection. Results: We found that pre-treatment of vitamin D had an antiinflammatory action on both EBV-specific CD8+ T cells and on CD3/ CD28-stimulated T cells: secretion of pro-inflammatory cytokines (IFNgamma and TNF-alpha) was decreased, whereas secretion of antiinflammatory cytokines (IL-5 and TGF-beta) was increased. At baseline, CD8+ T cells of early MS patients showed a higher secretion of TNFalpha and lower secretion of IL-5. Addition of vitamin D did not restore the same levels of both cytokines as compared to HC. Vitamin D-pretreated CD8+T cells exhibited a decreased secretion of IFN-gamma and TNF-alpha, even after depletion of CD4+ T cells from culture. Conclusion: Vitamin D has a direct anti-inflammatory effect on CD8+ T cells independently from CD4+ T cells. CD8+ T cells of patients with earlyMS are less responsive to the inflammatory effect of vitamin D than HC, pointing toward an intrinsic dysregulation of CD8+ T cells. The modulation of EBV-specific CD8+T cells by vitaminDsuggests that there may be interplay between these twomajor environmental factors of MS. This study was supported by a grant from the Swiss National Foundation (PP00P3-124893), and by an unrestricted research grant from Bayer to RDP.
Resumo:
Determining the time since deposition of fingermarks may prove necessary in order to assess their relevance to criminal investigations. The crucial factor is the initial composition of fingermarks because it represents the starting point of any ageing model. This study mainly aimed to characterize the initial composition of fingerprints, which show a high variability between donors (inter-variability), but also to investigate the variations among fingerprints from the same donor (intra-variability). Solutions to reduce this initial variability using squalene and cholesterol as target compounds are proposed and should be further investigated. The influence of substrates was also evaluated and the initial composition was observed to be larger on porous surface than non-porous surfaces. Preliminary aging of fingerprints over 30 days was finally studied on a porous and a non-porous substrate to evaluate the potential for dating of fingermarks. Squalene was observed to decrease in a faster rate on a non-porous substrate.
Resumo:
Lipids available in fingermark residue represent important targets for enhancement and dating techniques. While it is well known that lipid composition varies among fingermarks of the same donor (intra-variability) and between fingermarks of different donors (inter-variability), the extent of this variability remains uncharacterised. Thus, this worked aimed at studying qualitatively and quantitatively the initial lipid composition of fingermark residue of 25 different donors. Among the 104 detected lipids, 43 were reported for the first time in the literature. Furthermore, palmitic acid, squalene, cholesterol, myristyl myristate and myristyl myristoleate were quantified and their correlation within fingermark residue was highlighted. Ten compounds were then selected and further studied as potential targets for dating or enhancement techniques. It was shown that their relative standard deviation was significantly lower for the intra-variability than for the inter-variability. Moreover, the use of data pretreatments could significantly reduce this variability. Based on these observations, an objective donor classification model was proposed. Hierarchical cluster analysis was conducted on the pre-treated data and the fingermarks of the 25 donors were classified into two main groups, corresponding to "poor" and "rich" lipid donors. The robustness of this classification was tested using fingermark replicates of selected donors. 86% of these replicates were correctly classified, showing the potential of such a donor classification model for research purposes in order to select representative donors based on compounds of interest.
Resumo:
Introduction: Epstein-Barr Virus(EBV) has been repeatedly associatedwith multiple sclerosis (MS). Wehave previously shown that there is ahigh peripheral as well as intrathecalactivation of EBV-, but not cytomegalovirus(CMV)-specific CD8+ Tcells, early in the course of MS,strengthening the link between EBVand MS. However, the trigger of thisincreased EBV-specific CD8+ T cellresponse remains obscure. It could resultfrom a higher EBV viral load. Alternatively,it could be due to an intrinsicallydeficient EBV-specificCTL response, cytotoxic granulesmediated.Thus, we performed anin-depth study of the phenotype of exvivo EBV- and CMV-specific CD8+T cells in MS patients and control patients,assessing their cytotoxic activity.Methods:We analyzed the profileof cytotoxic granules in EBV- andCMV-specific CD8+ T cells in a cohortof 13 early MS patients, 20 lateMS, 30 other neurological diseases(OND) patients and 7 healthy controlsubjects. Ex vivo analysis of EBV- orCMV-specific CD8+ T cells was performedusing HLA class I/tetramercomplexes coupled to CCR7 andCD57 markers in conjunction withperforin, granzymes A, BandKstaining.In a sub-cohort of MS patientsand controls, cytotoxic activity ofEBV- and CMV-specific CD8+ Tcells was investigated using a functionalCFSE CTL assay. Results: UsingHLA Class I tetramers for EBVand CMV, we found that the frequencyof EBV- or CMV-specificCD8+ T cells were similar in all studysubjects. Most of EBV- and CMVspecificCD8+Tcells were highly differentiated(CCR7-) and a variousproportion expressed the exhaustionmarker CD57. MS and OND patientshad increased perforin expression inEBV-specific CD8+ T cells. Most importantly,we found that MS patientswith longer disease duration tended tohave lower CTL cytotoxicity as comparedto earlyMSpatients or controls.Conclusions: Effector EBV-specificCD8+ T cells are increased in earlyMS, however their cytotoxic granuleprofile does not seem to be fully alteredand the cytotoxic activity ofthese cells is normal. However, thecytotoxic activity of CTL decreasedin late MS patients suggesting an exhaustionof EBV-specific CD8+ Tcells possibly due to EBV reactivation.This work was supported by theSwiss National Foundation PP00B3-124893, the Swiss Society for MS,and the Biaggi Foundation to RADP.
Resumo:
Copiato nell'Italia del Nord verso il 1350, il manoscritto Ferrell 5 è oggi il solo testimone della "Continuation du Roman de Meliadus" che racconta le avventure di Artù, di Meliadus il padre di Tristano, e del Buon Cavaliere senza Paura padre di Dinadan, partiti alla ricerca di Morholt, prigioniero su di un'isola lontana. Ora, questa inchiesta è solo un pretesto: al centro dell'interesse dei tre re non sta tanto l'avventura promessa quanto i racconti che essi collezionano in occasione dei diversi scali di questo viaggio per mare, durante il quale non succede quasi niente. La ricerca di Morholt agisce quale racconto-cornice che non solo mette in scena le condizioni della presa di parola da parte dei cavalieri-narratori e organizza i racconti, anzi li drammatizza, ma funziona anche da matrice che informa, feconda e rigenera questi stessi racconti. Quanto all'isolamento, imposto dalla navigazione, esso permette lo sbocciare di una piccola ma prestigiosa società di narratori che non ha nulla da invidiare a quella delle raccolte di novelle. Così, un racconto dopo l'altro, si definisce un'arte di narrare che espone ed esplora i legami tra valore del racconto e bontà della cavalleria: la perfezione poetica, fonte del piacere estetico, è solo l'altra faccia della perfezione cavalleresca.
Resumo:
Introduction: Cognitive impairment affects 40-65% of multiple sclerosis (MS) patients, often since early stages of the disease (relapsing remitting MS, RRMS). Frequently affected functions are memory, attention or executive abilities but the most sensitive measure of cognitive deficits in early MS is the information processing speed (Amato, 2008). MRI has been extensively exploited to investigate the substrate of cognitive dysfunction in MS but the underlying physiopathological mechanisms remain unclear. White matter lesion load, whole-brain atrophy and cortical lesions' number play a role but correlations are in some cases modest (Rovaris, 2006; Calabrese, 2009). In this study, we aimed at characterizing and correlating the T1 relaxation times of cortical and sub-cortical lesions with cognitive deficits detected by neuropsychological tests in a group of very early RR MS patients. Methods: Ten female patients with very early RRMS (age: 31.6 ±4.7y; disease duration: 3.8 ±1.9y; EDSS disability score: 1.8 ±0.4) and 10 age- and gender-matched healthy volunteers (mean age: 31.2 ±5.8y) were included in the study. All participants underwent the following neuropsychological tests: Rao's Brief Repeatable Battery of Neuropsychological tests (BRB-N), Stockings of Cambridge, Trail Making Test (TMT, part A and B), Boston Naming Test, Hooper Visual Organization Test and copy of the Rey-Osterrieth Complex Figure. Within 2 weeks from neuropsychological assessment, participants underwent brain MRI at 3T (Magnetom Trio a Tim System, Siemens, Germany) using a 32-channel head coil. The imaging protocol included 3D sequences with 1x1x1.2 mm3 resolution and 256x256x160 matrix, except for axial 2D-FLAIR: -DIR (T2-weighted, suppressing both WM and CSF; Pouwels, 2006) -MPRAGE (T1-weighted; Mugler, 1991) -MP2RAGE (T1-weighted with T1 maps; Marques, 2010) -FLAIR SPACE (only for patient 4-10, T2-weighted; Mugler, 2001) -2D Axial FLAIR (0.9x0.9x2.5 mm3, 256x256x44 matrix). Lesions were identified by one experienced neurologist and radiologist using all contrasts, manually contoured and assigned to regional locations (cortical or sub-cortical). Lesion number, volume and T1 relaxation time were calculated for lesions in each contrast and in a merged mask representing the union of the lesions from all contrasts. T1 relaxation times of lesions were normalized with the mean T1 value in corresponding control regions of the healthy subjects. Statistical analysis was performed using GraphPad InStat software. Cognitive scores were compared between patients and controls with paired t-tests; p values ≤ 0.05 were considered significant. Spearmann correlation tests were performed between the cognitive tests, which differed significantly between patients and controls, and lesions' i) number ii) volume iii) T1 relaxation time iv) disease duration and v) years of study. Results: Cortical and sub-cortical lesions count, T1 values and volume are reported in Table 1 (A and B). All early RRMS patients showed cortical lesions (CLs) and the majority consisted of CLs type I (lesions with a cortical component extending to the sub-cortical tissue). The rest of cortical lesions were characterized as type II (intra-cortical lesions). No type III/IV lesions (large sub-pial lesions) were detected. RRMS patients were slightly less educated (13.5±2.5y vs. 16.3±1.8y of study, p=0.02) than the controls. Signs of cortical dysfunction (i.e. impaired learning, language, visuo-spatial skills or gnosis) were rare in all patients. However, patients showed on average lower scores on measures of visual attention and information processing speed (TMT-part A: p=0.01; TMT-part B: p=0.006; PASAT-included in the BRB-N: p=0.04). The T1 relaxation values of CLs type I negatively correlated with the TMT-part A score (r=0.78, p<0.01). The correlations of TMT-part B score and PASAT score with T1 relaxation time of lesions as well and the correlation between TMT-part A, TMT-part B and PASAT score with lesions' i) number ii) volume iii) disease duration and iv) years of study did not reach significance. In order to preclude possible influences from partial volume effects on the T1 values, the correlation between lesion volume and T1 value of CLs type I was calculated; no correlation was found, suggesting that partial volume effects did not affect the statistics. Conclusions: The present pilot study reports for the first time the presence and the T1 characteristics at 3 T of cortical lesions in very early RRMS (< 6 y disease duration). It also shows that CLS type I represents the most frequent cortical lesion type in this cohort of RRMS patients. In addition, it reveals a negative correlation between the attentional test TMT-part A and the T1 properties of cortical lesions type I. In other words, lower attention deficits are concomitant with longer T1-relaxation time in cortical lesions. In respect to this last finding, it could be speculated that long relaxation time correspond to a certain degree of tissue loss that is enough to stimulate compensatory mechanisms. This hypothesis is in line with previous fMRI studies showing functional compensatory mechanisms to help maintaining normal or sub-normal attention performances in RR MS patients (Penner, 2003).
Resumo:
Usually, the differentiation of inks on questioned documents is carried out by optical methods and thin layer chromatography (TLC). Therefore, spectrometric methods were also proposed in forensic literature for the analysis of dyes. Between these techniques, laser desorption/ionization mass spectrometry (LDI-MS) has demonstrated a great versatility thanks to its sensitivity to blue ballpoint ink dyes and minimal sample destruction. Previous researches concentrated mostly on the LDI-MS positive mode and have shown that this analytical tool offers higher discrimination power than high performance TLC (HPTLC) for the differentiation of blue ballpoint inks. Although LDI-MS negative mode has already been applied in numerous forensic domains like the studies of works of art, automotive paints or rollerball pens, its potential for the discrimination of ballpoint pens was never studied before. The aim of the present paper is therefore to evaluate its potential for the discrimination of blue ballpoint inks. After optimization of the method, ink entries from 33 blue ballpoint pens were analyzed directly on paper in both positive and negative modes by LDI-MS. Several cationic and anionic ink components were identified in inks; therefore, pens were classified and compared according to their formulations. Results show that additional information provided by anionic dyes and pigments significantly increases the discrimination power of positive mode. In fact, it was demonstrated that classifications obtained by the two modes were, to some extent, complementary (i.e., inks with specific cationic dyes not necessarily contained the same anionic components).