38 resultados para Electronic Portfolio
em Université de Lausanne, Switzerland
Resumo:
OBJECTIVE: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension. METHODS: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/ 106 +/- 23/11 mmHg, mean +/- SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary. RESULTS: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 +/- 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 +/- 18/15 to 143/94 +/- 22/11 mmHg, P = 0.04/0.02). CONCLUSIONS: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.
Resumo:
Tumor-associated macrophages (TAMs) invade the tumor stroma in many cancers, yet their role is incompletely understood. To visualize and better understand these critical cells in tumor progression, we screened a portfolio of rationally selected, injectable agents to image endogenous TAMs ubiquitously in three different cancer models (colon carcinoma, lung adenocarcinoma, and soft tissue sarcoma). AMTA680, a functionally derivatized magneto-fluorescent nanoparticle, labeled a subset of myeloid cells with an "M2" macrophage phenotype, whereas other neighboring cells, including tumor cells and a variety of other leukocytes, remained unlabeled. We further show that AMTA680-labeled endogenous TAMs are not altered and can be tracked noninvasively at different resolutions and using various imaging modalities, e.g., fluorescence molecular tomography, magnetic resonance imaging, and multiphoton and confocal intravital microscopy. Quantitative assessment of TAM distribution and activity in vivo identified that these cells cluster in delimited foci within tumors, show relatively low motility, and extend cytoplasmic protrusions for prolonged physical interactions with neighboring tumor cells. Noninvasive imaging can also be used to monitor TAM-depleting regimen quantitatively. Thus, AMTA680 or related cell-targeting agents represent appropriate injectable vehicles for in vivo analysis of the tumor microenvironment.
Resumo:
Dernière étape avant le monde professionnel, un cursus de spécialisation est un lieu de discussion, au carrefour des savoirs et des savoir-faire, permettant aux étudiants d'envisager sous un angle nouveau les contenus enseignés à l'université. Il ne s'agit plus seulement d'acquérir des connaissances mais aussi de développer des compétences transférables à d'autres types d'activité. L'équipe en charge de la spécialisation en Analyse du discours et de la communication publics proposée par la Faculté des Lettres de l'Université de Lausanne a oeuvré à l'intégration d'un nouvel outil informatique, le e-Portfolio, destiné à faciliter l'expression et la documentation des compétences individuelles développées par l'étudiant lors de son parcours de formation.
Resumo:
Nonadherence to treatment is a common problem in the clinical management of hypercholesterolemic patients. This study was carried out with the aim of monitoring the daily compliance to a 6-month course of lipid-lowering therapy, using a microelectronic device, the Medication Event Monitoring System (MEMS), versus pill count. Forty men with primary hypercholesterolemia were prescribed fluvastatin 1 x 40 mg daily, provided in a MEMS package to record the date and time of each opening of the pillbox. Thirty-nine of 40 patients (98%) completed the study. Total cholesterol and LDL cholesterol levels decreased significantly (18% and 25%, p < 0.001) during the 6-month therapy period. A high mean rate of compliance was achieved by MEMS using the following three indexes--compliance to total prescribed dose (88.8% +/- 13.5%), compliance to prescribed days (82.4% +/- 19.5%), and compliance to prescribed time of day (81.86% +/- 19.5%)--and by pill count (93.4% +/- 9.5%). In addition, the MEMS provided some patterns of nonadherence to medication, undetectable by pill count alone, such as a drug holiday in 38% of cases, a drug omission for more than 7 consecutive days in 9% of cases, and, conversely, use of more than the one prescribed daily dose in 47% of cases. A significant correlation between the rate of compliance and the decrease in LDL cholesterol was observed only when the compliance was assessed by MEMS. The results indicate that MEMS is a useful tool for monitoring compliance in clinical practice and may possibly increase adherence to long-term lipid-lowering therapy.
Resumo:
To ensure successful treatment, HIV patients must maintain a high degree of medication adherence over time. Since August 2004, patients who are (or are at risk of) experiencing problems with their HIV antiretroviral therapy (ART) have been referred by their physicians to an interdisciplinary HIV-adherence program. The program consists of a multifactorial intervention along with electronic drug monitoring (MEMS(TM)). The pharmacists organize individualized semi-structured motivational interviews based on cognitive, emotional, behavioral, and social issues. At the end of each session, the patient brings an adherence report to the physician. This enables the physician to use the adherence results to evaluate the treatment plan. The aim of this study was to retrospectively analyze this on-going interdisciplinary HIV-adherence program. All patients who were included between August 2004 and the end of April 2008 were analyzed. One hundred and four patients were included (59% women, median age 39 (31.0, 46.0) years, 42% black ethnicity). Eighty (77%) patients were ART-experienced patients and 59% had a protease inhibitor-based treatment. The retention rate was high (92%) in the program. Patient inclusion in this HIV-adherence program was determined by patient issues for naive patients and by nonadherence or suboptimal clinical outcomes for ART-experienced patients. The median time spent by a subject at the pharmacy was 35 (25.0, 48.0) minutes, half for the medication handling and half for the interview. The adherence results showed a persistence of 87% and an execution of 88%. Proportion of undetectable subjects increased during study. In conclusion, retention and persistence rates were high in this highly selected problematic population.
Resumo:
Richer and healthier agents tend to hold riskier portfolios and spend proportionally less on health expenditures. Potential explanations include health and wealth effects on preferences, expected longevity or disposable total wealth. Using HRS data, we perform a structural estimation of a dynamic model of consumption, portfolio and health expenditure choices with recursive utility, as well as health-dependent income and mortality risk. Our estimates of the deep parameters highlight the importance of health capital, mortality risk control, convex health and mortality adjustment costs and binding liquidity constraints to rationalize the stylized facts. They also provide new perspectives on expected longevity and on the values of life and health.
Resumo:
The n-octanol/water partition coefficient (log Po/w) is a key physicochemical parameter for drug discovery, design, and development. Here, we present a physics-based approach that shows a strong linear correlation between the computed solvation free energy in implicit solvents and the experimental log Po/w on a cleansed data set of more than 17,500 molecules. After internal validation by five-fold cross-validation and data randomization, the predictive power of the most interesting multiple linear model, based on two GB/SA parameters solely, was tested on two different external sets of molecules. On the Martel druglike test set, the predictive power of the best model (N = 706, r = 0.64, MAE = 1.18, and RMSE = 1.40) is similar to six well-established empirical methods. On the 17-drug test set, our model outperformed all compared empirical methodologies (N = 17, r = 0.94, MAE = 0.38, and RMSE = 0.52). The physical basis of our original GB/SA approach together with its predictive capacity, computational efficiency (1 to 2 s per molecule), and tridimensional molecular graphics capability lay the foundations for a promising predictor, the implicit log P method (iLOGP), to complement the portfolio of drug design tools developed and provided by the SIB Swiss Institute of Bioinformatics.
Resumo:
Introduction and objectives: The AMS 800TM is considered the gold standard for sphincter replacement. However, the one-ring design can erode the urethra and lead to severe complications. A mechanism that could alternatively compress successive segments of the urethra would limit such deleterious outcome. We report 12 weeks animal urethral tissue analysis following implantation of a new modular artificial sphincter. METHODS: The device is composed by three parts: the contractile unit, two rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor connected to an external computer. The computer can reveal specific failure of device components. The device was impkanted in eight male sheep. The rings were positioned around the urethra and the control unit was placed 5cm away. The device was working twenty hours per day; it was open 10min. per hour to allow urination. The animals were sacrificed after 12 weeks. The urethra and the tissues surrounding the control unit were macroscopically and microscopically examined. Two transversal sections crossing the sphincter and two transversal sections crossing the urethra alone were obtained and stained with modified Paragon after resin embedding. Urethra was also embedded in paraffin. The first section was stained with safranin-hematoxylin-eosin, the second section was stained with Masson's Trichrome and the remaining eight sections were available for immunolabelling of the macrophages.Results: The chronic study went uneventful. No clinical infection or pain was observed. The computer registered no specific failure in ring function, Nitinol wires and tube connectors. At explantation, except for a slight grade of lymphocytes in two out of eight specimens, no urethral stricture or atrophy could be observed. Immunohistochemistry confirmed the absence of macrophages. Tissue structure and organization of the urethra with and without artificial sphincter were similar. No migration of the device was observed.Conclusions: The study clearly showed no tissue damage or inflammation of the urethra. Electronic design, preservation of urethral vascularisation and adjustability after implantation are the key ideas to improve the actual AUS. Further studies will be carried out to evaluate this potential.