53 resultados para Earnings and dividend announcements, high frequency data, information asymmetry

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clozapine (CLO), an atypical antipsychotic, depends mainly on cytochrome P450 1A2 (CYP1A2) for its metabolic clearance. Four patients treated with CLO, who were smokers, were nonresponders and had low plasma levels while receiving usual doses. Their plasma levels to dose ratios of CLO (median; range, 0.34; 0.22 to 0.40 ng x day/mL x mg) were significantly lower than ratios calculated from another study with 29 patients (0.75; 0.22 to 2.83 ng x day/mL x mg; P < 0.01). These patients were confirmed as being CYP1A2 ultrarapid metabolizers by the caffeine phenotyping test (median systemic caffeine plasma clearance; range, 3.85; 3.33 to 4.17 mL/min/kg) when compared with previous studies (0.3 to 3.33 mL/min/kg). The sequencing of the entire CYP1A2 gene from genomic DNA of these patients suggests that the -164C > A mutation (CYP1A2*1F) in intron 1, which confers a high inducibility of CYP1A2 in smokers, is the most likely explanation for their ultrarapid CYP1A2 activity. A marked (2 patients) or a moderate (2 patients) improvement of the clinical state of the patients occurred after the increase of CLO blood levels above the therapeutic threshold by the increase of CLO doses to very high values (ie, up to 1400 mg/d) or by the introduction of fluvoxamine, a potent CYP1A2 inhibitor, at low dosage (50 to 100 mg/d). Due to the high frequency of smokers among patients with schizophrenia and to the high frequency of the -164C > A polymorphism, CYP1A2 genotyping could have important clinical implications for the treatment of patients with CLO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compared the extent and origin of muscle fatigue induced by short-pulse-low-frequency [conventional (CONV)] and wide-pulse-high-frequency (WPHF) neuromuscular electrical stimulation. We expected CONV contractions to mainly originate from depolarization of axonal terminal branches (spatially determined muscle fiber recruitment) and WPHF contractions to be partly produced via a central pathway (motor unit recruitment according to size principle). Greater neuromuscular fatigue was, therefore, expected following CONV compared with WPHF. Fourteen healthy subjects underwent 20 WPHF (1 ms-100 Hz) and CONV (50 &#956;s-25 Hz) evoked isometric triceps surae contractions (work/rest periods 20:40 s) at an initial target of 10% of maximal voluntary contraction (MVC) force. Force-time integral of the 20 evoked contractions (FTI) was used as main index of muscle fatigue; MVC force loss was also quantified. Central and peripheral fatigue were assessed by voluntary activation level and paired stimulation amplitudes, respectively. FTI in WPHF was significantly lower than in CONV (21,717 ± 11,541 vs. 37,958 ± 9,898 N·s P<0,001). The reductions in MVC force (WPHF: -7.0 ± 2.7%; CONV: -6.2 ± 2.5%; P < 0.01) and paired stimulation amplitude (WPHF: -8.0 ± 4.0%; CONV: -7.4 ± 6.1%; P < 0.001) were similar between conditions, whereas no change was observed for voluntary activation level (P > 0.05). Overall, our results showed a different motor unit recruitment pattern between the two neuromuscular electrical stimulation modalities with a lower FTI indicating greater muscle fatigue for WPHF, possibly limiting the presumed benefits for rehabilitation programs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: In contrast to conventional (CONV) neuromuscular electrical stimulation (NMES), the use of "wide-pulse, high-frequencies" (WPHF) can generate higher forces than expected by the direct activation of motor axons alone. We aimed at investigating the occurrence, magnitude, variability and underlying neuromuscular mechanisms of these "Extra Forces" (EF). METHODS: Electrically-evoked isometric plantar flexion force was recorded in 42 healthy subjects. Additionally, twitch potentiation, H-reflex and M-wave responses were assessed in 13 participants. CONV (25Hz, 0.05ms) and WPHF (100Hz, 1ms) NMES consisted of five stimulation trains (20s on-90s off). RESULTS: K-means clustering analysis disclosed a responder rate of almost 60%. Within this group of responders, force significantly increased from 4% to 16% of the maximal voluntary contraction force and H-reflexes were depressed after WPHF NMES. In contrast, non-responders showed neither EF nor H-reflex depression. Twitch potentiation and resting EMG data were similar between groups. Interestingly, a large inter- and intrasubject variability of EF was observed. CONCLUSION: The responder percentage was overestimated in previous studies. SIGNIFICANCE: This study proposes a novel methodological framework for unraveling the neurophysiological mechanisms involved in EF and provides further evidence for a central contribution to EF in responders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La trachée et les bronches proximales sont de fins conduits subtils, ingénieusement structurés par une partie cartilagineuse antérieure résistante aux variations de pression et une partie membraneuse postérieure souple. Par leurs faibles volumes (espace mort) ils délivrent un grand pourcentage de l'air inspiré aux voies distales, puis au parenchyme pulmonaire, permettant les échanges de gaz. Cette belle harmonie respiratoire peut être rapidement mise à mal dès qu'un processus atteint ces voies respiratoires proximales, soit en les comprimant, processus sténosant, soit en affaiblissant leur structure, trachéo-bronchomalacie, soit en ouvrant leur paroi sur les structures médiastinales, fistule trachéo/broncho-médiastinales, pleurales ou autres. Le pronostic vital est alors rapidement engagé au vu de l'absolue nécessité du bon fonctionnement de ces fins conduits, une petite diminution du calibre de leurs fines lumières provoquant une baisse importante de leurs surfaces. Dans ces situations à haut potentiel de complication majeure les interventions endoscopiques pour restaurer l'intégrité de ces conduits sont alors fort risquées, et il est primordial de pouvoir les effectuer dans un cadre sécurisé au maximum. La réalisation de ces gestes par la technique décrite dans notre article « Use of combined suspension laryngoscopy, flexible bronchoscopy and high frequency jet ventilation forY-shaped airway stents delivery" permet la sécurité nécessaire à ces situations instable, en effet -la laryngoscopie en suspension expose les voies proximales en offrant un accès le plus large possible à l'arbre trachéobronchique ce qui permet l insertion de multiples instruments parfois volumineux, -la Jet ventilation assure une oxygénation et une ventilation adéquate par un fin cathéter placé soit dans le poumon sain, soit en distalité de la lésion -la bronchoscopie souple, passant au travers d'endroits exigus et courbes permet le déploiement sous vision direct, au millimètre près, de divers dispositifs. Cette association remplace avantageusement la technique traditionnelle qui insère les stents à l'aveugle, et en apnée, ce qui représente de haut risque de mauvais positionnement des stents avec des conséquences immédiates sur l'oxygénation et la ventilation souvent déjà bien altérées. Perspective et conclusion : cette technique est utile pour l'insertion des stents en Y, centraux, comme décrit dans notre article, et les indications peuvent être étendues aux stents distaux pour lesquels l'accès n'est parfois pas aisé avec le bronchoscope rigide, et pour d'autres interventions endoscopiques, laser, cryothérapie, radiofréquence ou l'insertion de nouveaux dispositifs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tumor-reactive T cells play an important role in cancer immunosurveillance. Applying the multimer technology, we report here an unexpected high frequency of Melan-A-specific CTLs in a melanoma patient with progressive lymph node metastases, consisting of 18 and 12.8% of total peripheral blood and tumor-infiltrating CD8+ T cells, respectively. Melan-A-specific CTLs revealed a high cytolytic activity against allogeneic Melan-A-expressing target cells but failed to kill the autologous tumor cells. Loading of the tumor cells with Melan-A peptide reversed the resistance to killing, suggesting impaired function of the MHC class I antigen processing and presentation pathway. Mutations of the coding region of the HLA-A2 binding Melan-A26-35 peptide or down-regulation of the MHC class I heavy chain, the antigenic peptide TAP, and tapasin could be excluded. However, PCR and immunohistochemical analysis revealed a deficiency of the immunoproteasomes low molecular weight protein 2 and low molecular weight protein 7 in the primary tumor cells, which affects the quantity and quality of generated T-cell epitopes and might explain the resistance to killing. This is supported by our data, demonstrating that the resistance to killing can be partially reversed by pre-exposure of the tumor cells to IFN-gamma, which is known to induce the immunoproteasomes. Overall, this is the first report of an extremely high frequency of tumor-specific CTLs that exhibit competent T-cell-effector functions but fail to lyse the autologous tumor cells. Immunotherapeutic approaches should not only focus on the induction of a robust antitumor immune response, but should also have to target tumor immune escape mechanisms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In contrast with the low frequency of most single epitope reactive T cells in the preimmune repertoire, up to 1 of 1,000 naive CD8(+) T cells from A2(+) individuals specifically bind fluorescent A2/peptide multimers incorporating the A27L analogue of the immunodominant 26-35 peptide from the melanocyte differentiation and melanoma associated antigen Melan-A. This represents the only naive antigen-specific T cell repertoire accessible to direct analysis in humans up to date. To get insight into the molecular basis for the selection and maintenance of such an abundant repertoire, we analyzed the functional diversity of T cells composing this repertoire ex vivo at the clonal level. Surprisingly, we found a significant proportion of multimer(+) clonotypes that failed to recognize both Melan-A analogue and parental peptides in a functional assay but efficiently recognized peptides from proteins of self- or pathogen origin selected for their potential functional cross-reactivity with Melan-A. Consistent with these data, multimers incorporating some of the most frequently recognized peptides specifically stained a proportion of naive CD8(+) T cells similar to that observed with Melan-A multimers. Altogether these results indicate that the high frequency of Melan-A multimer(+) T cells can be explained by the existence of largely cross-reactive subsets of naive CD8(+) T cells displaying multiple specificities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the use of high frequency jet ventilation (HFJV) in patients undergoing percutanous thermal ablation procedures.Materials: From may to september 2011 patients with lung, liver or kidney tumors suitable for percutanous thermal ablation were prospectively enrolled to be treated under general anesthesia using HFJV instead of conventional positive pressure ventilation (PPV). Our primary endpoint was feasability of HFJV during percutanous ablation, our secondary endpoints were assessment of breathing related movements by image fusion (CT/US), precision and ease of needle placement by number of CT aquisition/needle reposition and procedure related complications.Results: Twenty-nine patients (21 males, 8 females mean age 66.2 years) with 30 liver tumors, 1 kidney tumors and 6 lung tumors were included. Tumor ablation was performed by radiofrequency (RFA) in 26 cases, microwaves ( MWA) in 2 and cryoablation (CRA) in 1. The ablation procedure could be completed under HFJV in 22 patients. In 2 patients HFVJ had to be stopped in favor of PPV because the tumor was better seen under PPV. HFJV was not performed in 5. Breathing related movements of the target lesion in the cranio-caudal direction as estimated by image fusion were always inferior to 5mm compared to 20mm when patients are under PPV. Needle placement was straightforward under CT as well as US. No patient needed needle repositionning before ablation. We did not observe any HFJV related complications.Conclusions: HFJV significantly reduces breathing movements of target lesion during percutaneous ablation procedures. It does not seem to cause any particular complication. However in some cases such as tumors located at the base of the lungs or in the dome of the liver, the target may be best seen under PPV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The profiling of MDMA tablets can be carried out using different sets of characteristics. The first type of measurements performed on MDMA tablets are physical characteristics (i.e. post-tabletting characteristics). They yield preliminary profiling data that may be valuable in a first stage for investigation purposes. However organic impurities (i.e. pre-tabletting characteristics) are generally considered to bring more reliable information, particularly for presentation of evidence in court. This work aimed therefore at evaluating the added value of combining pre-tabletting characteristics and post-tabletting characteristics of seized MDMA tablets. In approximately half of the investigated cases, the post-tabletting links were confirmed with organic impurities analyses. In the remaining cases, post-tabletting batches (post-TBs) were divided in several pre-tabletting batches (pre-TBs), thus supporting the hypothesis that several production batches of MDMA powder (pre-TBs) were used to produce one single post-TB (i.e. tablets having the same shape, diameter, thickness, weight and score; but different organic impurities composition). In view of the obtained results, the hypotheses were discussed through illustrating examples. In conclusion, both sets of characteristics were found relevant alone and combined together. They actually provide distinct information about MDMA illicit production and trafficking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Next-generation sequencing offers an unprecedented opportunity to jointly analyze cellular and viral transcriptional activity without prerequisite knowledge of the nature of the transcripts. SupT1 cells were infected with a vesicular stomatitis virus G envelope protein (VSV-G)-pseudotyped HIV vector. At 24 h postinfection, both cellular and viral transcriptomes were analyzed by serial analysis of gene expression followed by high-throughput sequencing (SAGE-Seq). Read mapping resulted in 33 to 44 million tags aligning with the human transcriptome and 0.23 to 0.25 million tags aligning with the genome of the HIV-1 vector. Thus, at peak infection, 1 transcript in 143 is of viral origin (0.7%), including a small component of antisense viral transcription. Of the detected cellular transcripts, 826 (2.3%) were differentially expressed between mock- and HIV-infected samples. The approach also assessed whether HIV-1 infection modulates the expression of repetitive elements or endogenous retroviruses. We observed very active transcription of these elements, with 1 transcript in 237 being of such origin, corresponding on average to 123,123 reads in mock-infected samples (0.40%) and 129,149 reads in HIV-1-infected samples (0.45%) mapping to the genomic Repbase repository. This analysis highlights key details in the generation and interpretation of high-throughput data in the setting of HIV-1 cellular infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The efficiency of co-expression and linkage of distinct T-DNAs present in separate Agrobacterium tumefaciens was analysed in Arabidopsis thaliana transformed by the vacuum infiltration method. Co-expression was monitored by the synthesis of three bacterial proteins involved in the production of polyhydroxybutyrate (PHB) in the plastids. Out of 80 kanamycin-resistant transgenic plants analysed, 13 plants were co-transformed with the two distinct T-DNAs and produced PHB. Of those, 7 lines had a kanamycin-resistance segregation ratio consistent with the presence of a single functional insert. Genetic linkage between the distinct T-DNAs was demonstrated for all 13 PHB-producing lines, while physical linkage between the distinct T-DNAs was shown for 12 out of 13 lines. T-DNAs were frequently linked in an inverted orientation about the left borders. Transformation of A. thaliana by the co-infiltration of two A. tumefaciens containing distinct T-DNAs is, thus, an efficient approach for the integration and expression of several transgenes at a single locus. This approach will facilitate the creation and study of novel metabolic pathways requiring the expression of numerous transgenes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sparsely spaced highly permeable fractures of the granitic rock aquifer at Stang-er-Brune (Brittany, France) form a well-connected fracture network of high permeability but unknown geometry. Previous work based on optical and acoustic logging together with single-hole and cross-hole flowmeter data acquired in 3 neighbouring boreholes (70-100 m deep) has identified the most important permeable fractures crossing the boreholes and their hydraulic connections. To constrain possible flow paths by estimating the geometries of known and previously unknown fractures, we have acquired, processed and interpreted multifold, single- and cross-hole GPR data using 100 and 250 MHz antennas. The GPR data processing scheme consisting of timezero corrections, scaling, bandpass filtering and F-X deconvolution, eigenvector filtering, muting, pre-stack Kirchhoff depth migration and stacking was used to differentiate fluid-filled fracture reflections from source generated noise. The final stacked and pre-stack depth-migrated GPR sections provide high-resolution images of individual fractures (dipping 30-90°) in the surroundings (2-20 m for the 100 MHz antennas; 2-12 m for the 250 MHz antennas) of each borehole in a 2D plane projection that are of superior quality to those obtained from single-offset sections. Most fractures previously identified from hydraulic testing can be correlated to reflections in the single-hole data. Several previously unknown major near vertical fractures have also been identified away from the boreholes.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Healthcare professionals regularly read the summary of product characteristics (SmPC) as one of the various sources of information on the risks of drug use in women of childbearing age and during pregnancy. The aim of this article is to present an overview of the teratogenic potential of various antiepileptic drugs and to compare these data with the information provided by the SmPCs. METHODS: A literature search on the teratogenic risks of 19 antiepileptic agents was conducted and the results were compared with the information on the use in women of childbearing age and during pregnancy provided by the SmPCs of 38 commercial products available in Switzerland and Germany. RESULTS: The teratogenic risk is discussed in all available SmPCs. Quantification of the risk for birth defects and the numbers of documented pregnancies are mostly missing. Reproductive safety information in SmPCs showed poor concordance with risk levels reported in the literature. Recommendations concerning the need to monitor plasma levels and possibly perform dose adjustments during pregnancy to prevent treatment failure were missing in five Swiss and two German SmPCs. DISCUSSION: The information regarding use in women of childbearing age and during pregnancy provided by the SmPCs is heterogeneous and poorly reflects the current state of knowledge. Regular updates of SmPCs are warranted in order for these documents to be of reliable use for health care professionals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To report feasibility and potential benefits of high-frequency jet ventilation (HFJV) in tumor ablations techniques in liver, kidney, and lung lesions. METHODS: This prospective study included 51 patients (14 women, mean age 66 years) bearing 66 tumors (56 hepatic, 5 pulmonary, 5 renal tumors) with a median size of 16 ± 8.7 mm, referred for tumor ablation in an intention-to-treat fashion before preoperative anesthesiology visit. Cancellation and complications of HFJV were prospectively recorded. Anesthesia and procedure duration, as well as mean CO2 capnea, were recorded. When computed tomography guidance was used, 3D spacial coordinates of an anatomical target &lt;2 mm in diameter on 8 slabs of 4 slices of 3.75-mm slice thickness were registered. RESULTS: HFJV was used in 41 of 51 patients. Of the ten patients who were not candidate for HFJV, two patients had contraindication to HFJV (severe COPD), three had lesions invisible under HFJV requiring deep inspiration apnea for tumor targeting, and five patients could not have HFJV because of unavailability of a trained anesthetic team. No specific complication or hypercapnia related to HFJV were observed despite a mean anesthetic duration of 2 h and ventilation performed in procubitus (n = 4) or lateral decubitus (n = 6). Measured internal target movement was 0.3 mm in x- and y-axis and below the slice thickness of 3.75 mm in the z-axis in 11 patients. CONCLUSIONS: HFJV is feasible in 80 % of patients allowing for near immobility of internal organs during liver, kidney, and lung tumor ablation.