72 resultados para DECREASES ARTERIAL-PRESSURE

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

During recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000 m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 min after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (AIx) and a diastolic index (AId) of pressure augmentation by reflections. At 5 min, both indices were below preexercise. At further time-points, AIx remained low, while AId progressively increased, to overshoot above preexercise at 45 min. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance-trained athletes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blood pressure is abnormally elevated in acute stroke in most patients. This blood pressure increase is usually transient and associated with a poor prognosis. Lowering blood pressure too importantly during this period may worsen the outcome of the patient. Antihypertensive therapy is therefore required only when blood pressure is severely increased, especially in the presence of intracerebral haemorrhage. Initiating treatment before admission to the hospital is not recommended. The medications to be preferred are the blockers of the renin-angiotensin system, the beta-blocker labetalol (which possesses also alpha-blocking properties) and NO donors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMEDurant la phase de récupération d'un exercice de course à pied d'intensité maximale ou submaximale, une augmentation de la pression artérielle systolique centrale (aortique) résultant de la réflexion des ondes de pouls sur l'arbre vasculaire est constatée chez l'individu en bonne santé. En diastole cependant, l'impact de la réflexion de ces ondes de pouls sur la pression centrale demeure inconnu durant la récupération d'un exercice.Nous avons évalué les ondes de pouls centrales systolique et diastolique chez onze athlètes d'endurance durant la phase de récupération d'un exercice de course à pied dans des conditions d'effort maximal (sur tapis de course) et lors d'un effort submaximal lors d'une course à pied de 4000 mètres en plein air sur terrain mixte.Pour chaque sujet et lors des deux exercices, l'onde de pouls a été mesurée au niveau radial par tonométrie d'aplanation durant une phase de repos précédant l'exercice, puis à 5, 15, 25, 35 et 45 minutes après la fin de l'exercice. En utilisant une fonction mathématique de transfert, l'onde de pouls centrale a été extrapolée à partir de l'onde de pouls radiale. En compilant la forme de l'onde de pouls centrale avec une mesure simultanée de la pression artérielle brachiale, un index d'augmentation de l'onde de pouls en systole (Alx) et en diastole (Als) peut être calculé, reflétant l'augmentation des pressions résultant de la réflexion des ondes sur l'arbre vasculaire périphérique.A 5 minutes de la fin de l'exercice, les deux index ont été mesurés moindres que ceux mesurés lors de la phase précédant celui-ci. Lors des mesures suivantes, Alx est resté bas, alors que Aid a progressivement augmenté pour finalement dépasser la valeur de repos après 45 minutes de récupération. Le même phénomène a été constaté pour les deux modalités d'exercice (maximal ou submaximal). Ainsi, au-delà de quelques minutes de récupération après un exercice de course d'intensité maximale ou submaximale, nous avons montré par ces investigations que les ondes de pouls réfléchies en périphérie augmentent de façon sélective la pression centrale en diastole chez l'athlète d'endurance.ABSTRACTDuring recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 minutes after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (Alx) and a diastolic index (Aid) of pressure augmentation by reflections. At 5 minutes, both indices were below preexercise. At further time-points, Alx remained low, while Aid progressively increased, to overshoot above preexercise at 45 minutes. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance- trained athletes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Factors associated with the detection of raised systolic pulmonary artery pressure (sPAP) levels in patients with a prior episode of pulmonary embolism (PE) are not well known. METHODS: We used the RIETE Registry database to identify factors associated with the finding of sPAP levels ≥50 mm Hg on trans-thoracic echocardiography, in 557 patients with a prior episode of acute, symptomatic PE. RESULTS: Sixty-two patients (11.1%; 95% CI: 8.72-14.1) had sPAP levels ≥50 mm Hg. These patients were more likely women, older, and more likely had chronic lung disease, heart failure, renal insufficiency or leg varicosities than those with PAP levels <50mm Hg. During the index PE event, they more likely had recent immobility, and more likely presented with hypoxemia, increased sPAP levels, atrial fibrillation, or right bundle branch block. On multivariate analysis, women aged ≥70 years (hazard ratio [HR]: 2.0; 95% CI: 1.0-3.7), chronic heart or chronic lung disease (HR: 2.4; 95% CI: 1.3-4.4), atrial fibrillation at PE presentation (HR: 2.8; 95% CI: 1.3-6.1) or varicose veins (HR: 1.8; 95% CI: 1.0-3.3) were all associated with an increased risk to have raised sPAP levels. Chronic heart disease, varicose veins, and atrial fibrillation were independent predictors in women, while chronic heart disease, atrial fibrillation, a right bundle branch block or an S1Q3T3 pattern on the electrocardiogram were independent predictors in men. CONCLUSIONS: Women aged ≥70 years more likely had raised sPAP levels than men after a PE episode. Additional variables influencing this risk seem to differ according to gender.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Numerous genetic loci have been associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans. We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N = 74,064) and follow-up studies (N = 48,607), we identified at genome-wide significance (P = 2.7 × 10(-8) to P = 2.3 × 10(-13)) four new PP loci (at 4q12 near CHIC2, 7q22.3 near PIK3CG, 8q24.12 in NOV and 11q24.3 near ADAMTS8), two new MAP loci (3p21.31 in MAP4 and 10q25.3 near ADRB1) and one locus associated with both of these traits (2q24.3 near FIGN) that has also recently been associated with SBP in east Asians. For three of the new PP loci, the estimated effect for SBP was opposite of that for DBP, in contrast to the majority of common SBP- and DBP-associated variants, which show concordant effects on both traits. These findings suggest new genetic pathways underlying blood pressure variation, some of which may differentially influence SBP and DBP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new high-precision ultrasonic device was developed to determine noninvasively arterial compliance as a function of blood pressure. Because of the nonlinear elastic properties of arterial walls, measurements of compliance can be appropriately compared only if obtained over a range of pressures. This apparatus was used to evaluate in a double-blind, parallel fashion the effect of three different antihypertensive drugs and of a placebo on radial artery compliance. Thirty-two normotensive volunteers were randomly allocated to an 8-day, once-a-day oral treatment with either a placebo, 100 mg atenolol, 20 mg nitrendipine, or 20 mg lisinopril. Blood pressure, heart rate, radial artery diameter, and arterial compliance were measured immediately before as well as 6 hours after dosing on the first and last days of the study. On the eighth day of administration, within 6 hours after dosing, lisinopril induced an acute increase in radial artery diameter, from 2.99 +/- 0.06 to 3.28 +/- 0.09 mm (mean +/- SEM, p less than 0.01). The compliance-pressure curve was shifted upward on day 1 (p less than 0.01) as well as on day 8 (p less than 0.05). None of the other drugs induced any significant modification of these parameters. Arterial compliance has a strong nonlinear dependency on intra-arterial pressure and therefore has to be defined as a function of pressure. Antihypertensive drugs acting by different mechanisms may have different effects on the mechanical properties of large arteries.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Genetic determinants of blood pressure are poorly defined. We undertook a large-scale, gene-centric analysis to identify loci and pathways associated with ambulatory systolic and diastolic blood pressure. We measured 24-hour ambulatory blood pressure in 2020 individuals from 520 white European nuclear families (the Genetic Regulation of Arterial Pressure of Humans in the Community Study) and genotyped their DNA using the Illumina HumanCVD BeadChip array, which contains ≈50 000 single nucleotide polymorphisms in >2000 cardiovascular candidate loci. We found a strong association between rs13306560 polymorphism in the promoter region of MTHFR and CLCN6 and mean 24-hour diastolic blood pressure; each minor allele copy of rs13306560 was associated with 2.6 mm Hg lower mean 24-hour diastolic blood pressure (P=1.2×10(-8)). rs13306560 was also associated with clinic diastolic blood pressure in a combined analysis of 8129 subjects from the Genetic Regulation of Arterial Pressure of Humans in the Community Study, the CoLaus Study, and the Silesian Cardiovascular Study (P=5.4×10(-6)). Additional analysis of associations between variants in gene ontology-defined pathways and mean 24-hour blood pressure in the Genetic Regulation of Arterial Pressure of Humans in the Community Study showed that cell survival control signaling cascades could play a role in blood pressure regulation. There was also a significant overrepresentation of rare variants (minor allele frequency: <0.05) among polymorphisms showing at least nominal association with mean 24-hour blood pressure indicating that a considerable proportion of its heritability may be explained by uncommon alleles. Through a large-scale gene-centric analysis of ambulatory blood pressure, we identified an association of a novel variant at the MTHFR/CLNC6 locus with diastolic blood pressure and provided new insights into the genetic architecture of blood pressure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

AIM: To discuss the use of new ultrasonic techniques that make it possible to visualize elastic (carotid) and muscular (radial) capacitance arteries non-invasively. RESULTS OF DATA REVIEW: Measurements of carotid wall thickness and the detection of atheromas are related to arterial pressure, to other risk factors and to the risk of subsequent complications. The use of high-frequency ultrasound (7.5-10 MHz), measurements of far wall thicknesses in areas free of atheromas at end-diastole (by ECG gating or pressure waveform recording) and descriptions of the size and characteristics of atherosclerotic plaques allow a non-invasive assessment of vascular hypertrophy and atherosclerosis in hypertensive patients. CONCLUSIONS: Careful attention to methodologic and physiologic factors is needed to provide accurate information about the anatomy of the dynamically pulsating arterial tree.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: An inverse relationship between blood pressure (BP) and cognitive function has been found in adults, but limited data are available in adolescents and young adults. We examined the prospective relation between BP and cognitive function in adolescence. METHODS: We examined the association between BP measured at the ages of 12-15 years in school surveys and cognitive endpoints measured in the Seychelles Child Development Study at ages 17 (n = 407) and 19 (n = 429) years, respectively. We evaluated multiple domains of cognition based on subtests of the Cambridge Neurological Test Automated Battery (CANTAB), the Woodcock Johnson Test of Scholastic Achievement (WJTA), the Finger Tapping test (FT) and the Kaufman Brief Intelligence Test (K-BIT). We used age, sex and height-specific z-scores of SBP, DBP and mean arterial pressure (MAP). RESULTS: Six out of the 21 cognitive endpoints tested were associated with BP. However, none of these associations were found to hold for both males and females or for different subtests within the same neurodevelopmental domain or for both SBP and DBP. Most of these associations disappeared when analyses were adjusted for selected potential confounding factors such as socio-economic status, birth weight, gestational age, BMI, alcohol consumption, blood glucose, and total n-3 and n-6 polyunsaturated fats. CONCLUSIONS: Our findings do not support a consistent association between BP and subsequent performance on tests assessing various cognitive domains in adolescents.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: In our hands, in vivo segmental vessel length changes up to 5% because of blood pressure: increasing in arterial pressure is associated to decrease in segmental vessel length. METHODS AND MATERIAL: Using two piezoelectric crystals sutured on vessel wall and a high fidelity pressure probe, we recorded artery length variations as function of blood pressure, before and after an end-to-end anastomosis on four pigs carotid arteries. RESULTS: Mean arterial pressure before anastomosis = 73 mmHg (+/- 12); mean arterial pressure after anastomosis = 91 mmHg (+/- 14); mean crystals displacement before anastomosis during systole = -0.21 mm; mean crystals displacement after anastomosis during systole = +0.24 mm; mean distance between crystals before anastomosis = 12.3 mm (+/- 0.8) and after anastomosis = 11.2 mm (+/- 0.5). CONCLUSIONS: In the acute phase following an end-to-end anastomosis, an increase in blood pressure causes increasing in vessel length, with an exponential correlation. The anastomosis is constantly subjected to a longitudinal traction whose magnitude depends on blood pressure.