16 resultados para Current systems
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND: Recommendations for statin use for primary prevention of coronary heart disease (CHD) are based on estimation of the 10- year CHD risk. We compared the 10-year CHD risk assessments and eligibility percentages for statin therapy using three scoring algorithms currently used in Europe. METHODS: We studied 5683 women and men, aged 35-75, without overt cardiovascular disease (CVD), in a population-based study in Switzerland. We compared the 10-year CHD risk using three scoring schemes, i.e., the Framingham risk score (FRS) from the U.S. National Cholesterol Education Program's Adult Treatment Panel III (ATP III), the PROCAM scoring scheme from the International Atherosclerosis Society (IAS), and the European risk SCORE for low-risk countries, without and with extrapolation to 60 years as recommended by the European Society of Cardiology guidelines (ESC). With FRS and PROCAM, high-risk was defined as a 10- year risk of fatal or non-fatal CHD>20% and a 10-year risk of fatal CVD≥5% with SCORE. We compared the proportions of high-risk participants and eligibility for statin use according to these three schemes. For each guideline, we estimated the impact of increased statin use from current partial compliance to full compliance on potential CHD deaths averted over 10 years, using a success proportion of 27% for statins. RESULTS: Participants classified at high-risk (both genders) were 5.8% according to FRS and 3.0% to the PROCAM, whereas the European risk SCORE classified 12.5% at high-risk (15.4% with extrapolation to 60 years). For the primary prevention of CHD, 18.5% of participants were eligible for statin therapy using ATP III, 16.6% using IAS, and 10.3% using ESC (13.0% with extrapolation) because ESC guidelines recommend statin therapy only in high-risk subjects. In comparison with IAS, agreement to identify eligible adults for statins was good with ATP III, but moderate with ESC. Using a population perspective, a full compliance with ATP III guidelines would reduce up to 17.9% of the 24′ 310 CHD deaths expected over 10 years in Switzerland, 17.3% with IAS and 10.8% with ESC (11.5% with extrapolation). CONCLUSIONS: Full compliance with guidelines for statin therapy would result in substantial health benefits, but proportions of high-risk adults and eligible adults for statin use varied substantially depending on the scoring systems and corresponding guidelines used for estimating CHD risk in Europe.
Resumo:
In this review, intratumoral drug disposition will be integrated into the wide range of resistance mechanisms to anticancer agents with particular emphasis on targeted protein kinase inhibitors. Six rules will be established: 1. There is a high variability of extracellular/intracellular drug level ratios; 2. There are three main systems involved in intratumoral drug disposition that are composed of SLC, ABC and XME enzymes; 3. There is a synergistic interplay between these three systems; 4. In cancer subclones, there is a strong genomic instability that leads to a highly variable expression of SLC, ABC or XME enzymes; 5. Tumor-expressed metabolizing enzymes play a role in tumor-specific ADME and cell survival and 6. These three systems are involved in the appearance of resistance (transient event) or in the resistance itself. In addition, this article will investigate whether the overexpression of some ABC and XME systems in cancer cells is just a random consequence of DNA/chromosomal instability, hypo- or hypermethylation and microRNA deregulation, or a more organized modification induced by transposable elements. Experiments will also have to establish if these tumor-expressed enzymes participate in cell metabolism or in tumor-specific ADME or if they are only markers of clonal evolution and genomic deregulation. Eventually, the review will underline that the fate of anticancer agents in cancer cells should be more thoroughly investigated from drug discovery to clinical studies. Indeed, inhibition of tumor expressed metabolizing enzymes could strongly increase drug disposition, specifically in the target cells resulting in more efficient therapies.
Resumo:
1 6 STRUCTURE OF THIS THESIS -Chapter I presents the motivations of this dissertation by illustrating two gaps in the current body of knowledge that are worth filling, describes the research problem addressed by this thesis and presents the research methodology used to achieve this goal. -Chapter 2 shows a review of the existing literature showing that environment analysis is a vital strategic task, that it shall be supported by adapted information systems, and that there is thus a need for developing a conceptual model of the environment that provides a reference framework for better integrating the various existing methods and a more formal definition of the various aspect to support the development of suitable tools. -Chapter 3 proposes a conceptual model that specifies the various enviromnental aspects that are relevant for strategic decision making, how they relate to each other, and ,defines them in a more formal way that is more suited for information systems development. -Chapter 4 is dedicated to the evaluation of the proposed model on the basis of its application to a concrete environment to evaluate its suitability to describe the current conditions and potential evolution of a real environment and get an idea of its usefulness. -Chapter 5 goes a step further by assembling a toolbox describing a set of methods that can be used to analyze the various environmental aspects put forward by the model and by providing more detailed specifications for a number of them to show how our model can be used to facilitate their implementation as software tools. -Chapter 6 describes a prototype of a strategic decision support tool that allow the analysis of some of the aspects of the environment that are not well supported by existing tools and namely to analyze the relationship between multiple actors and issues. The usefulness of this prototype is evaluated on the basis of its application to a concrete environment. -Chapter 7 finally concludes this thesis by making a summary of its various contributions and by proposing further interesting research directions.
Resumo:
In the context of the investigation of the use of automated fingerprint identification systems (AFIS) for the evaluation of fingerprint evidence, the current study presents investigations into the variability of scores from an AFIS system when fingermarks from a known donor are compared to fingerprints that are not from the same source. The ultimate goal is to propose a model, based on likelihood ratios, which allows the evaluation of mark-to-print comparisons. In particular, this model, through its use of AFIS technology, benefits from the possibility of using a large amount of data, as well as from an already built-in proximity measure, the AFIS score. More precisely, the numerator of the LR is obtained from scores issued from comparisons between impressions from the same source and showing the same minutia configuration. The denominator of the LR is obtained by extracting scores from comparisons of the questioned mark with a database of non-matching sources. This paper focuses solely on the assignment of the denominator of the LR. We refer to it by the generic term of between-finger variability. The issues addressed in this paper in relation to between-finger variability are the required sample size, the influence of the finger number and general pattern, as well as that of the number of minutiae included and their configuration on a given finger. Results show that reliable estimation of between-finger variability is feasible with 10,000 scores. These scores should come from the appropriate finger number/general pattern combination as defined by the mark. Furthermore, strategies of obtaining between-finger variability when these elements cannot be conclusively seen on the mark (and its position with respect to other marks for finger number) have been presented. These results immediately allow case-by-case estimation of the between-finger variability in an operational setting.
Resumo:
INTRODUCTION: Eddy currents induced by switching of magnetic field gradients can lead to distortions in short echo-time spectroscopy or diffusion weighted imaging. In small bore magnets, such as human head-only systems, minimization of eddy current effects is more demanding because of the proximity of the gradient coil to conducting structures. METHODS: In the present study, the eddy current behavior achievable on a recently installed 7 tesla-68 cm bore head-only magnet was characterized. RESULTS: Residual effects after compensation were shown to be on the same order of magnitude as those measured on two whole body systems (3 and 4.7 T), while using two to three fold increased gradient slewrates.
Resumo:
The common feature of urea cycle diseases (UCD) is a defect in ammonium elimination in liver, leading to hyperammonemia. This excess of circulating ammonium eventually reaches the central nervous system, where the main toxic effects of ammonium occur. These are reversible or irreversible, depending on the age of onset as well as the duration and the level of ammonium exposure. The brain is much more susceptible to the deleterious effects of ammonium during development than in adulthood, and surviving UCD patients may develop cortical and basal ganglia hypodensities, cortical atrophy, white matter atrophy or hypomyelination and ventricular dilatation. While for a long time, the mechanisms leading to these irreversible effects of ammonium exposure on the brain remained poorly understood, these last few years have brought new data showing in particular that ammonium exposure alters several amino acid pathways and neurotransmitter systems, cerebral energy, nitric oxide synthesis, axonal and dendritic growth, signal transduction pathways, as well as K(+) and water channels. All these effects of ammonium on CNS may eventually lead to energy deficit, oxidative stress and cell death. Recent work also proposed neuroprotective strategies, such as the use of NMDA receptor antagonists, nitric oxide inhibitors, creatine and acetyl-l-carnitine, to counteract the toxic effects of ammonium. Better understanding the pathophysiology of ammonium toxicity to the brain under UCD will allow the development of new strategies for neuroprotection.
Resumo:
BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly used in daily clinical practice. However, little is known about its clinical utility such as image quality, safety and impact on patient management. In addition, there is limited information about the potential of CMR to acquire prognostic information. METHODS: The European Cardiovascular Magnetic Resonance Registry (EuroCMR Registry) will consist of two parts: 1) Multicenter registry with consecutive enrolment of patients scanned in all participating European CMR centres using web based online case record forms. 2) Prospective clinical follow up of patients with suspected coronary artery disease (CAD) and hypertrophic cardiomyopathy (HCM) every 12 months after enrolment to assess prognostic data. CONCLUSION: The EuroCMR Registry offers an opportunity to provide information about the clinical utility of routine CMR in a large number of cases and a diverse population. Furthermore it has the potential to gather information about the prognostic value of CMR in specific patient populations.
Resumo:
This paper reports on the purpose, design, methodology and target audience of E-learning courses in forensic interpretation offered by the authors since 2010, including practical experiences made throughout the implementation period of this project. This initiative was motivated by the fact that reporting results of forensic examinations in a logically correct and scientifically rigorous way is a daily challenge for any forensic practitioner. Indeed, interpretation of raw data and communication of findings in both written and oral statements are topics where knowledge and applied skills are needed. Although most forensic scientists hold educational records in traditional sciences, only few actually followed full courses that focussed on interpretation issues. Such courses should include foundational principles and methodology - including elements of forensic statistics - for the evaluation of forensic data in a way that is tailored to meet the needs of the criminal justice system. In order to help bridge this gap, the authors' initiative seeks to offer educational opportunities that allow practitioners to acquire knowledge and competence in the current approaches to the evaluation and interpretation of forensic findings. These cover, among other aspects, probabilistic reasoning (including Bayesian networks and other methods of forensic statistics, tools and software), case pre-assessment, skills in the oral and written communication of uncertainty, and the development of independence and self-confidence to solve practical inference problems. E-learning was chosen as a general format because it helps to form a trans-institutional online-community of practitioners from varying forensic disciplines and workfield experience such as reporting officers, (chief) scientists, forensic coordinators, but also lawyers who all can interact directly from their personal workplaces without consideration of distances, travel expenses or time schedules. In the authors' experience, the proposed learning initiative supports participants in developing their expertise and skills in forensic interpretation, but also offers an opportunity for the associated institutions and the forensic community to reinforce the development of a harmonized view with regard to interpretation across forensic disciplines, laboratories and judicial systems.
Resumo:
This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.
Resumo:
The major problems associated with the use of corticosteroids for the treatment of ocular diseases are their poor intraocular penetration to the posterior segment when administered locally and their secondary side effects when given systemically. To circumvent these problems more efficient methods and techniques of local delivery are being developed. The purposes of this study were: (1) to investigate the pharmacokinetics of intraocular penetration of hemisuccinate methyl prednisolone (HMP) after its delivery using the transscleral Coulomb controlled iontophoresis (CCI) system applied to the eye or after intravenous (i.v.) injection in the rabbit, (2) to test the safety of the CCI system for the treated eyes and (3) to compare the pharmacokinetic profiles of HMP intraocular distribution after CCI delivery to i.v. injection. For each parameter evaluated, six rabbit eyes were used. For the CCI system, two concentrations of HMP (62.5 and 150mg ml(-1)), various intensities of current and duration of treatment were analyzed. In rabbits serving as controls the HMP was infused in the CCI device but without applied electric current. For the i.v. delivery, HMP at 10mg kg(-1)as a 62.5mg ml(-1)solution was used. The rabbits were observed clinically for evidence of ocular toxicity. At various time points after the administration of drug, rabbits were killed and intraocular fluids and tissues were sampled for methylprednisolone (MP) concentrations by high pressure liquid chromatography (HPLC). Histology examinations were performed on six eyes of each group. Among groups that received CCI, the concentrations of MP increased in all ocular tissues and fluids in relation to the intensities of current used (0.4, 1.0 and 2.0mA/0.5cm(2)) and its duration (4 and 10min). Sustained and highest levels of MP were achieved in the choroid and the retina of rabbit eyes treated with the highest current and 10min duration of CCI. No clinical toxicity or histological lesions were observed following CCI. Negligible amounts of MP were found in ocular tissues in the CCI control group without application of current. Compared to i.v. administration, CCI achieved higher and more sustained tissue concentrations with negligible systemic absorption. These data demonstrate that high levels of MP can be safely achieved in intraocular tissues and fluids of the rabbit eye, using CCI. With this system, intraocular tissues levels of MP are higher than those achieved after i.v. injection. Furthermore, if needed, the drug levels achieved with CCI can be modulated as a function of current intensity and duration of treatment. CCI could therefore be used as an alternative method for the delivery of high levels of MP to the intraocular tissues of both the anterior and posterior segments.
Resumo:
PURPOSE OF REVIEW: In the present review, we will provide the scientific rationale for applying systems biology to the development of vaccines and particularly HIV vaccines, the predictive power of systems biology on the vaccine immunological profile, the correlation between systems biology and the immunological functional profiles of different candidate vaccines, and the value of systems biology in the selection process of identifying the best-in-class candidate vaccines and in the decision process to move into in-vivo evaluation in clinical trials. RECENT FINDINGS: Systems biology has been recently applied to the characterization of the protective yellow fever vaccine YF17D and of seasonal flu vaccines. This has been instrumental in the identification of the components of the immune response that need to be stimulated by the vaccine in order to generate protective immunity. It is worth noting that a systems biology approach is currently being performed to identify correlates of immune protection of the RV144 Thai vaccine, the only known vaccine that showed modest protection against HIV reacquisition. SUMMARY: Systems biology represents a novel and powerful approach to predict the vaccine immunological profile, to identify the protective components of the immune response, and to help in the selection process of the best-in-class vaccines to move into clinical development.
Resumo:
Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.
Resumo:
OBJECTIVE: This study aimed to survey current practices in European epilepsy monitoring units (EMUs) with emphasis on safety issues. METHODS: A 37-item questionnaire investigating characteristics and organization of EMUs, including measures for prevention and management of seizure-related serious adverse events (SAEs), was distributed to all identified European EMUs plus one located in Israel (N=150). RESULTS: Forty-eight (32%) EMUs, located in 18 countries, completed the questionnaire. Epilepsy monitoring unit beds are 1-2 in 43%, 3-4 in 34%, and 5-6 in 19% of EMUs; staff physicians are 1-2 in 32%, 3-4 in 34%, and 5-6 in 19% of EMUs. Personnel operating in EMUs include epileptologists (in 69% of EMUs), clinical neurophysiologists trained in epilepsy (in 46% of EMUs), child neurologists (in 35% of EMUs), neurology and clinical neurophysiology residents (in 46% and in 8% of EMUs, respectively), and neurologists not trained in epilepsy (in 27% of EMUs). In 20% of EMUs, patients' observation is only intermittent or during the daytime and primarily carried out by neurophysiology technicians and/or nurses (in 71% of EMUs) or by patients' relatives (in 40% of EMUs). Automatic detection systems for seizures are used in 15%, for body movements in 8%, for oxygen desaturation in 33%, and for ECG abnormalities in 17% of EMUs. Protocols for management of acute seizures are lacking in 27%, of status epilepticus in 21%, and of postictal psychoses in 87% of EMUs. Injury prevention consists of bed protections in 96% of EMUs, whereas antisuffocation pillows are employed in 21%, and environmental protections in monitoring rooms and in bathrooms are implemented in 38% and in 25% of EMUs, respectively. The most common SAEs were status epilepticus reported by 79%, injuries by 73%, and postictal psychoses by 67% of EMUs. CONCLUSIONS: All EMUs have faced different types of SAEs. Wide variation in practice patterns and lack of protocols and of precautions to ensure patients' safety might promote the occurrence and severity of SAEs. Our findings highlight the need for standardized and shared protocols for an effective and safe management of patients in EMUs.