67 resultados para "quality assurance

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: EORTC trial 22991 was designed to evaluate the addition of concomitant and adjuvant short-term hormonal treatments to curative radiotherapy in terms of disease-free survival for patients with intermediate risk localized prostate cancer. In order to assess the compliance to the 3D conformal radiotherapy protocol guidelines, all participating centres were requested to participate in a dummy run procedure. An individual case review was performed for the largest recruiting centres as well. MATERIALS AND METHODS: CT-data of an eligible prostate cancer patient were sent to 30 centres including a description of the clinical case. The investigator was requested to delineate the volumes of interest and to perform treatment planning according to the protocol. Thereafter, the investigators of the 12 most actively recruiting centres were requested to provide data on five randomly selected patients for an individual case review. RESULTS: Volume delineation varied significantly between investigators. Dose constraints for organs at risk (rectum, bladder, hips) were difficult to meet. In the individual case review, no major protocol deviations were observed, but a number of dose reporting problems were documented for centres using IMRT. CONCLUSIONS: Overall, results of this quality assurance program were satisfactory. The efficacy of the combination of a dummy run procedure with an individual case review is confirmed in this study, as none of the evaluated patient files harboured a major protocol deviation. Quality assurance remains a very important tool in radiotherapy to increase the reliability of the trial results. Special attention should be given when designing quality assurance programs for more complex irradiation techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The level of information provided by ink evidence to the criminal and civil justice system is limited. The limitations arise from the weakness of the interpretative framework currently used, as proposed in the ASTM 1422-05 and 1789-04 on ink analysis. It is proposed to use the likelihood ratio from the Bayes theorem to interpret ink evidence. Unfortunately, when considering the analytical practices, as defined in the ASTM standards on ink analysis, it appears that current ink analytical practices do not allow for the level of reproducibility and accuracy required by a probabilistic framework. Such framework relies on the evaluation of the statistics of the ink characteristics using an ink reference database and the objective measurement of similarities between ink samples. A complete research programme was designed to (a) develop a standard methodology for analysing ink samples in a more reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in a forensic context. This report focuses on the first of the three stages. A calibration process, based on a standard dye ladder, is proposed to improve the reproducibility of ink analysis by HPTLC, when these inks are analysed at different times and/or by different examiners. The impact of this process on the variability between the repetitive analyses of ink samples in various conditions is studied. The results show significant improvements in the reproducibility of ink analysis compared to traditional calibration methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method of objectively determining imaging performance for a mammography quality assurance programme for digital systems was developed. The method is based on the assessment of the visibility of a spherical microcalcification of 0.2 mm using a quasi-ideal observer model. It requires the assessment of the spatial resolution (modulation transfer function) and the noise power spectra of the systems. The contrast is measured using a 0.2-mm thick Al sheet and Polymethylmethacrylate (PMMA) blocks. The minimal image quality was defined as that giving a target contrast-to-noise ratio (CNR) of 5.4. Several evaluations of this objective method for evaluating image quality in mammography quality assurance programmes have been considered on computed radiography (CR) and digital radiography (DR) mammography systems. The measurement gives a threshold CNR necessary to reach the minimum standard image quality required with regards to the visibility of a 0.2-mm microcalcification. This method may replace the CDMAM image evaluation and simplify the threshold contrast visibility test used in mammography quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The phase III EORTC 22033-26033/NCIC CE5 intergroup trial compares 50.4 Gy radiotherapy with up-front temozolomide in previously untreated low-grade glioma. We describe the digital EORTC individual case review (ICR) performed to evaluate protocol radiotherapy (RT) compliance. METHODS: Fifty-eight institutions were asked to submit 1-2 randomly selected cases. Digital ICR datasets were uploaded to the EORTC server and accessed by three central reviewers. Twenty-seven parameters were analysed including volume delineation, treatment planning, organ at risk (OAR) dosimetry and verification. Consensus reviews were collated and summary statistics calculated. RESULTS: Fifty-seven of seventy-two requested datasets from forty-eight institutions were technically usable. 31/57 received a major deviation for at least one section. Relocation accuracy was according to protocol in 45. Just over 30% had acceptable target volumes. OAR contours were missing in an average of 25% of cases. Up to one-third of those present were incorrectly drawn while dosimetry was largely protocol compliant. Beam energy was acceptable in 97% and 48 patients had per protocol beam arrangements. CONCLUSIONS: Digital RT plan submission and review within the EORTC 22033-26033 ICR provide a solid foundation for future quality assurance procedures. Strict evaluation resulted in overall grades of minor and major deviation for 37% and 32%, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Quality assurance (QA) in clinical trials is essential to ensure treatment is safely and effectively delivered. As QA requirements have increased in complexity in parallel with evolution of radiation therapy (RT) delivery, a need to facilitate digital data exchange emerged. Our objective is to present the platform developed for the integration and standardization of QART activities across all EORTC trials involving RT. METHODS: The following essential requirements were identified: secure and easy access without on-site software installation; integration within the existing EORTC clinical remote data capture system; and the ability to both customize the platform to specific studies and adapt to future needs. After retrospective testing within several clinical trials, the platform was introduced in phases to participating sites and QART study reviewers. RESULTS: The resulting QA platform, integrating RT analysis software installed at EORTC Headquarters, permits timely, secure, and fully digital central DICOM-RT based data review. Participating sites submit data through a standard secure upload webpage. Supplemental information is submitted in parallel through web-based forms. An internal quality check by the QART office verifies data consistency, formatting, and anonymization. QART reviewers have remote access through a terminal server. Reviewers evaluate submissions for protocol compliance through an online evaluation matrix. Comments are collected by the coordinating centre and institutions are informed of the results. CONCLUSIONS: This web-based central review platform facilitates rapid, extensive, and prospective QART review. This reduces the risk that trial outcomes are compromised through inadequate radiotherapy and facilitates correlation of results with clinical outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Swiss laboratories performing toxicological road traffic analyses have been authorized for many years by the Swiss Federal Roads Office (FEDRO). In 2003 FEDRO signed a contract with the Swiss Society of Legal Medicine (SSLM) to organize the complete quality management concerning road traffic analyses. For this purpose a multidisciplinary working group was established under the name of "road traffic commission (RTC)". RTC has to organize external quality control, to interpret the results of these controls, to perform audits in the laboratories and to report all results to FEDRO. Furthermore the working group can be mandated for special tasks by FEDRO. As an independent organization the Swiss Center for Quality Control (CSCQ) in Geneva manages the external quality controls in the laboratory over the past years. All tested drugs and psychoactive substances are listed in a federal instruction. The so-called 'zero tolerance substances' (THC, morphine, cocaine, amphetamine, methamphetamine, MDMA and MDEA) and their metabolites have to be tested once a year, all other substances (benzodiazepines, zolpidem, phenobarbital, etc.) periodically. Results over the last years show that all laboratories are generally within the confidence interval of +/-30% of the mean value. In cases of non-conformities measures have to be taken immediately and reported to the working group. External audits are performed triennially but accredited laboratories can combine this audit with the approval of the Swiss Accreditation Service (SAS). During the audits a special checklist filled in by the laboratory director is assessed. Non-conformities have to be corrected. During the process of establishing a new legislation, RTC had an opportunity of advising FEDRO. In collaboration with FEDRO, RTC and hence SSLM can work actively on improving of quality assurance in road traffic toxicological analyses, and has an opportunity to bring its professional requests to the federal authorities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The EORTC 22043-30041 trial investigates the role of the addition of androgen suppression to post-operative radiotherapy in patients who have undergone radical prostatectomy. As part of the quality assurance of radiotherapy (QART) a Dummy Run (DR) procedure was performed. MATERIALS AND METHOD: The protocol included detailed and published delineation guidelines. Participating institutions digitally submitted radiotherapy treatment volumes and a treatment plan for a standard clinical case. Submissions were centrally reviewed using the VODCA software platform. RESULTS: Thirty-eight submissions from thirty-one institutions were reviewed. Six were accepted without comments. Twenty-three were accepted with comments on one or more items: target volume delineation (22), OAR delineation (23), planning and dosimetry (3) or treatment verification (1). Nine submissions were rejected requiring resubmission, seven for target volume delineation reasons alone. Intervention to highlight the importance of delineation guidelines was made prior to the entry of the first patient in the trial. After this, a lower percentage of resubmissions was required. CONCLUSIONS: The EORTC 22043-30041 Dummy Run highlights the need for timely and effective QART in clinical trials. The variation in target volume and OAR definition demonstrates that clinical guidelines and radiotherapy protocols are not a substitute for QART procedures. Early intervention in response to the Dummy Run improved protocol understanding.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quality assurance is an essential process which should be applied for any organised breast cancer screening program since mammography it the only test available for an early diagnosis. It should also assess the quality of diagnostic and treatment processes in order to ascertain that the quality of the screening program would not be altered by the procedures which take place after the screening. Quality assurance must be applied to each component of the screening process: equipment, radiographers (technicians) as well as radiologists. It is a multidisciplinary approach following a well defined protocol, which should be supervised by a coordination unit, the Breast Cancer Screening Foundation in Canton of Vaud. Performances of the Vaud program show clearly at what extend multiple reading method improves the quality of screening. It seems that there is no inconvenient to involve radiologists who wish to participate without any selection to the reading process provided that there is in place a team of 2nd and 3rd readers who benefit of an appropriate training and experience.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le prélèvement des ganglions sentinelles apparaît comme une technique séduisante pour l'évaluation ganglionnaire des cancers du col utérin de faible stade. La sélection d'une population à bas risque de métastase ganglionnaire, un entraînement minimal et le respect de quelques règles simples permettent de limiter le risque de faux négatif au minimum. La technique apporte des informations supplémentaires sur le plan anatomique en identifiant des ganglions situés en dehors des zones habituelles de curage, et sur le plan histologique avec la mise en évidence de cellules tumorales isolées et surtout de micrométastases dont la valeur pronostique est suspectée Sentinel node biopsy appears as a promising technique for the assessment of nodal disease in early cervical cancers. Selection of a population with a low risk of nodal metastasis, a minimal training, and simple rules allow a low false negative rate. Sentinel node biopsy provides supplementary information, such as anatomical information (nodes outside of routine lymphadenectomy areas) and histological information (isolated tumors cells and micrometastases).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Novel therapeutic agents targeting the epidermal growth factor receptor (EGFR) have improved outcomes for patients with colorectal carcinoma. However, these therapies are effective only in a subset of patients. Activating mutations in the KRAS gene are found in 30-40% of colorectal tumors and are associated with poor response to anti-EGFR therapies. Thus, KRAS mutation status can predict which patient may or may not benefit from anti-EGFR therapy. Although many diagnostic tools have been developed for KRAS mutation analysis, validated methods and standardized testing procedures are lacking. This poses a challenge for the optimal use of anti-EGFR therapies in the management of colorectal carcinoma. Here we review the molecular basis of EGFR-targeted therapies and the resistance to treatment conferred by KRAS mutations. We also present guideline recommendations and a proposal for a European quality assurance program to help ensure accuracy and proficiency in KRAS mutation testing across the European Union.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Quality control in health care should be performed by health professionals. To do so they must define indicators, set up studies aimed at measuring and analyzing quality of care, and implement quality assurance programs in health care systems. The elements of a quality improvement program of this kind are described, with special emphasis on the contribution of epidemiology in this field.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Le développement de méthodes de mesure de la qualité des soins et les actions visant à son amélioration font partie intégrante de la pratique quotidienne. Les infections nosocomiales représentent un Indicateur Incontournable et leur prévention apparaît comme un champ d'action privilégié du concept de l'amélioration continue de la qualité des soins. Dans ce domaine, de nombreuses mesures ont fait l'objet d'études répondant à des critères méthodologiques de qualité élevée, dont les résultats sont hautement significatifs au plan statistique. Les interventions complexes concernant par exemple l'ensemble des patients d'un service ou d'une institution ne permettent que difficilement de satisfaire à ces exigences méthodologiques. Sous certaines conditions, elle peuvent cependant avoir un impact réel et parfois durable sur la qualité des soins. A titre d'exemple, nous discutons deux interventions complexes dans le domaine de la prévention des infections nosocomiales, résultant de démarches visant à une amélioration globale et durable de la qualité des soins. L'utilisation d'outils épidémiologiques adaptés permet également d'estimer le bénéfice des Interventions en milieu hospitalier conformément à ce que la communauté scientifique reconnaît comme étant une recherche clinique de qualité.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Quality assurance programmes are becoming a common practice in the field of mammography. At the present time several recommendations exist and different test objects are used to optimize this radiological procedure. The goal of this study was to check if geographically distant centres using different quality control procedures were comparable when using a common objective way of assessing image quality. The results show that consensus still needs to be found among radiologists to reach a satisfactory level of harmony between patient doses and image quality in Europe.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: Early assessment of radiotherapy (RT) quality in the ongoing EORTC trial comparing primary temozolomide versus RT in low-grade gliomas. MATERIALS AND METHODS: RT plans provided for dummy cases were evaluated and compared against expert plans. We analysed: (1) tumour and organs-at-risk delineation, (2) geometric and dosimetric characteristics, (3) planning parameters, compliance with dose prescription and Dmax for OAR (4) indices: RTOG conformity index (CI), coverage factor (CF), tissue protection factor (PF); conformity number (CN = PF x CF); dose homogeneity in PTV (U). RESULTS: Forty-one RT plans were evaluated. Only two (5%) centres were requested to repeat CTV-PTV delineations. Three (7%) plans had a significant under-dosage and dose homogeneity in one deviated > 10%. Dose distribution was good with mean values of 1.5, 1, 0.68, and 0.68 (ideal values = 1) for CI, CF, PF, and CN, respectively. CI and CN strongly correlated with PF and they correlated with PTV. Planning with more beams seems to increase PTV(Dmin), improving CF. U correlated with PTV(Dmax). CONCLUSION: Preliminary results of the dummy run procedure indicate that most centres conformed to protocol requirements. To quantify plan quality we recommend systematic calculation of U and either CI or CN, both of which measure the amount of irradiated normal brain tissue.