304 resultados para Internal resonance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The general proficiency in physical diagnostic skills seems to be declining in relation to the development of new technologies. The few studies that have examined this question have invariably used recordings of cardiac events obtained from patients. However, this type of evaluation may not correlate particularly well with bedside skills. Our objectives were 1) To compare the cardiac auscultatory skills of physicians in training with those of experienced cardiologists by using real patients to test bedside diagnostic skills. 2) To evaluate the impact of a five-month bedside cardiac auscultation training program. METHODS: 1) In an academic primary care center, 20 physicians (trainees in internal medicine and family practice) and two skilled academic cardiologists listened to 33 cardiac events in 13 patients directly at bedside and identified the cardiac events by completing an open questionnaire. Heart sounds, murmurs and diagnosis were determined beforehand by an independent skilled cardiologist and were validated by echocardiography. Thirteen primary cardiologic diagnoses were possible.2) Ten of the physicians agreed to participate in a course of 45-minute sessions once a week for 5 months. After the course they listened again to the same patients (pre/post-interventional study). RESULTS: 1) The experts were the most skillful, achieving 69% recognition of heart sounds and murmurs and correct diagnoses in 62% of cases. They also heard all of the diastolic murmurs. The residents heard only 40% of the extra heart sounds and made a correct diagnosis in 24% of cases. 2) After the weekly training sessions, their mean percentage for correct diagnosis was 35% [an increase of 66% (p < 0.05)]. CONCLUSIONS: The level of bedside diagnostic skills in this relatively small group of physicians in training is indeed low, but can be improved by a course focusing on realistic bedside teaching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METhods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. RESULTS: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline). CONCLUSION: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the impact of navigator timing on image quality in navigator-gated and real-time motion-corrected, free-breathing, three-dimensional (3D) coronary MR angiography (MRA) with submillimeter spatial image resolution. Both phantom and in vivo investigations were performed. 3D coronary MRA with real-time navigator technology was applied using variable navigator time delays (time delay between the navigator and imaging sequences) and varying spatial resolutions. Quantitative objective and subjective image quality parameters were assessed. For high-resolution imaging, reduced image quality was found as a function of increasing navigator time delay. Lower spatial resolution coronary MRA showed only minor sensitivity to navigator timing. These findings were consistent among volunteers and phantom experiments. In conclusion, for submillimeter navigator-gated and real-time motion-corrected 3D coronary MRA, shortening the time delay between the navigator and the imaging portion of the sequence becomes increasingly important for improved spatial resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a novel compressed sensing technique to accelerate the magnetic resonance imaging (MRI) acquisition process. The method, coined spread spectrum MRI or simply s(2)MRI, consists of premodulating the signal of interest by a linear chirp before random k-space under-sampling, and then reconstructing the signal with nonlinear algorithms that promote sparsity. The effectiveness of the procedure is theoretically underpinned by the optimization of the coherence between the sparsity and sensing bases. The proposed technique is thoroughly studied by means of numerical simulations, as well as phantom and in vivo experiments on a 7T scanner. Our results suggest that s(2)MRI performs better than state-of-the-art variable density k-space under-sampling approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute myocarditis was until recently one of the most difficult diagnoses in cardiology. The spectrum of signs and symptoms is very wide, the usual non-invasive tests lack specificity and the myocardial biopsy is only performed in a minority of cases to confirm the diagnosis. Due to its unique ability to directly image myocardial necrosis, fibrosis and oedema, cardiac magnetic resonance (CMR) is now considered the primary tool for noninvasive assessment of patients with suspected myocarditis. CMR is also useful for monitoring disease activity under treatment. Myocarditis has been associated with the development of dilated cardiomyopathy; CMR could play a role in the follow-up of such cases to detect the progression toward a dilatative phenotype. Precise mapping of myocardial lesions with cardiac MRI is invaluable to guide myocardial biopsy and increase its diagnostic yield by improving sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cistern of the velum interpositum is a space located between the corpus callosum dorsally and the roof of the third ventricle ventrally. Lesions located within the velum interpositum are rare and include meningiomas, pilocytic astrocytomas, atypical teratoid/rhabdoid tumors and arachnoid cysts. Epidermoid cysts in this location have not been reported previously. We report the clinical and radiological features of two patients with epidermoid cysts located in the velum interpositum. The patients presented with gait difficulty and features of raised intracranial pressure and magnetic resonance imaging demonstrated large tumors in the velum interpositum with intensities suggestive of epidermoid cysts. There was ventral displacement of the internal cerebral veins and dorsal displacement of the corpus callosum in keeping with a mass in the velum interpositum. Tumors of the third ventricle displace the internal cerebral veins dorsally. A transcallosal approach was used in both patients to effectively excise the tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three types of garnet have been distinguished in pelitic schists from an epidote-blueschist-facies unit of the Ambin and South Vanoise Brianconnais massifs on the basis of texture, chemical zoning and mineral inclusion characterization. Type-1 garnet cores with high Mn/Ca ratios are interpreted as pre-Alpine relicts, whereas Type-1 garnet rims, Type-2 inclusion-rich porphyroblasts and smaller Type-3 garnets are Alpine. The latter are all characterized by low Mn/Ca ratios and a coexisting mineral assemblage of blue amphibole, high-Si phengite, epidote and quartz. Prograde growth conditions during Alpine D-1 high-pressure (HP) metamorphism are recorded by a decrease in Mn and increase in Fe (+/-Ca) in the Type-2 garnets, culminating in peak P-T conditions of 14-16 kbar and 500degreesC in the deepest parts of the Ambin dome. The multistage growth history of Type-1 garnets indicates a polymetamorphic history for the Ambin and South Vanoise massifs; unfortunately, no age constraints are available. The new metamorphic constraints on the Alpine event in the massifs define a metamorphic T `gap' between them and their surrounding cover (Brianconnais and upper Schistes Lustres units), which experienced metamorphism only in the stability field of carpholite-lawsonite (T < 400degreesC). These data and supporting structural studies confirm that the Ambin and South Vanoise massifs are slices of `eclogitized' continental crust tectonically extruded within the Schistes Lustres units and Brianconnais covers. The corresponding tectonic contacts with top-to-east movement are responsible for the juxtaposition of lower-grade metamorphic units on the Ambin and South Vanoise massifs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast-passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography examination of the knee in terms of joint space width and amount of contrast material between the cartilage surfaces. Direct knee MR arthrography was performed in 11 patients on a 3-T MR imaging unit using a T1-weighted isotropic gradient echo sequence in a coronal plane with and without axial traction of 15 kg. Joint space widths were measured at the level of the medial and the lateral femorotibial joint with and without traction. The amount of contrast material in the medial and lateral femorotibial joint was assessed independently by two musculoskeletal radiologists in a semiquantitative manner using three grades ('absence of surface visualization, 'partial surface visualization or 'complete surface visualization'). With traction, joint space width increased significantly at the lateral femorotibial compartment (mean = 0.55 mm, p = 0.0105) and at the medial femorotibial compartment (mean = 0.4 mm, p = 0.0124). There was a trend towards an increased amount of contrast material in the femorotibial compartment with axial traction. Direct MR arthrography of the knee with axial traction showed a slight and significant increase of the width of the femorotibial compartment with a trend towards more contrast material between the articular cartilage surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Recent magnetic resonance imaging studies have attempted to relate volumetric brain measurements in early schizophrenia to clinical and functional outcome some years later. These studies have generally been negative, perhaps because gray and white matter volumes inaccurately assess the underlying dysfunction that might be predictive of outcome. OBJECTIVE: To investigate the predictive value of frontal and temporal spectroscopy measures for outcome in patients with first-episode psychoses. DESIGN: Left prefrontal cortex and left mediotemporal lobe voxels were assessed using proton magnetic resonance spectroscopy to provide the ratio of N-acetylaspartate (NAA) and choline-containing compounds to creatine and phosphocreatine (Cr) (NAA/Cr ratio). These data were used to predict outcome at 18 months after admission, as assessed by a systematic medical record audit. SETTING: Early psychosis clinic. PARTICIPANTS: Forty-six patients with first-episode psychosis. MAIN OUTCOME MEASURES: We used regression models that included age at imaging and duration of untreated psychosis to predict outcome scores on the Global Assessment of Functioning Scale, Clinical Global Impression scales, and Social and Occupational Functional Assessment Scale, as well as the number of admissions during the treatment period. We then further considered the contributions of premorbid function and baseline level of negative symptoms. RESULTS: The only spectroscopic predictor of outcome was the NAA/Cr ratio in the prefrontal cortex. Low scores on this variable were related to poorer outcome on all measures. In addition, the frontal NAA/Cr ratio explained 17% to 30% of the variance in outcome. CONCLUSIONS: Prefrontal neuronal dysfunction is an inconsistent feature of early psychosis; rather, it is an early marker of poor prognosis across the first years of illness. The extent to which this can be used to guide treatment and whether it predicts outcome some years after first presentation are questions for further research.